首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
除尘器对颗粒物的除尘效率与颗粒物的荷电量密切相关,PM2.5等细小颗粒物由于其荷电量不足而导致其吸收效率较低,对环境造成危害。为了增加粒子的荷电量,以粒子荷电原理为理论依据,从离子电流密度和通过电凝并扩大尘粒中位径2个方面研究了电除尘电源中交流电压分量对PM2.5等细小颗粒物荷电特性的影响,得出了电除尘器电源中交流电压分量可从以上2个方面提高装置对PM2.5等微小颗粒物的荷电量,且频率越高,幅值越大,荷电效果越好,从而可以提高装置对细小颗粒物的除尘效率。  相似文献   

2.
Currently, according to Taiwan’s Water Pollution Control Act, the environmental control of waterbodies and water quality depends on the effluent standards and the standard of water quality in the rivers. The Act demands that each stationary pollution source comply with the effluent standard before being discharged into the rivers, and that the overall water quality in the river shall not exceed the declared standard of water quality. To improve the condition of the waterbodies and water quality of the rivers, the Environmental Protection Administration (EPA) in Taiwan has made stricter regulations concerning the discharge standard. Such regulations will help to reduce the weight of individual pollutants discharged; the discharged wastewater, however, will still gradually worsen the water quality of the rivers even after complying with the effluent standard since some of the pollutant dischargers may decrease the concentration of pollutants by diluting the water before discharging; thus, the total weight of metals discharged in the rivers will not be reduced, and the water quality in the areas where the pollutant sources are concentrated will not thereby be significantly improved. To protect the irrigation water and farmlands from being polluted by discharged heavy metals in industrial wastewater, the EPA started controlling the sources in accordance with the total quantity control (TQC) as defined in the Water Pollution Control Act, in the hope of perfecting the environmental protection of waterbodies and water quality, as well as ensuring clean water sources without any pollution for the rivers, land, and people.  相似文献   

3.
A procedure, based on the concept of game theory, for the optimum design of an air pollution control system in thermal power plants is described. The problem is formulated as a four-criteria optimisation problem, with the cost of the electrostatic precipitator, the cost of the stack, the maximum ground-level concentration of particulate matter and the maximum ground-level concentration of sulfur dioxide as the objectives. The efficiency of the precipitator and the height of the stack are treated as the design variables. Geometric constraints in the form of lower and upper bounds on the design variables are imposed on the problem. The design problem is formulated as a four-person game, and the Nash non-cooperative solution is evaluated for irrational play to determine the starting point of the game. For the cooperative game, a supercriterion is formulated for the overall benefit of the players. The game is terminated when the optimal trade-off between the objectives is reached with the maximisation of the supercriterion. The methodology is demonstrated by solving a practical problem related to the design of an air pollution control system for a 210 MW thermal power plant.  相似文献   

4.
A two-dimensional numerical model for evaluating the wind flow and pollutant dispersion within a street canyon was first developed using the FLUENT code, which was then validated against a wind tunnel experiment. Then, the effects of the upstream building width and upwind building arrangement on the airflow and pollutant dispersion inside an isolated street canyon were investigated numerically. The numerical results revealed that: (1) the in-canyon vortex center shifts downwards as the upstream building width increases; (2) the recirculation zone covers the entire upstream building roof for the cases when W/H = 0.5, 1.0, 1.5, and 2.0 (W is the upstream building width and H is the building height), whereas the flow reattaches the upstream building roof for the cases when W/H = 2.5 and 3.0; (3) when the upstream building width is shorter than the critical width WC (= 2H), an increase in the upstream building width leads to an increase in the pollution level on the leeward wall of the canyon and a decrease in the roof-level concentrations at the upstream building; (4) when the upstream building width is longer than the critical width, the roof-level concentrations at the upstream building are negligibly small and the pollution level on the leeward wall of the canyon is almost unaffected by a further increase in the upstream building width; (5) when the buildings are placed upwind of the canyon, the flow attaches the upstream building roof and, therefore, almost none of the pollutants are distributed on the upstream building roof; and (6) the pollution levels inside the canyon and on the downstream building roof increase significantly with the number of upwind buildings.  相似文献   

5.
湿地植物在处理高负荷有机废水时会受到不同程度的氧化胁迫。本研究基于对浮萍的有机污染胁迫模拟系统,通过对浮萍脂质过氧化和抗氧化防御系统的监测与分析,研究了浮萍对有机污染胁迫的耐受能力及胁迫去除后浮萍的恢复规律。结果表明,浮萍对有机污染胁迫具有较高的耐受性,在胁迫去除后,具有一定的恢复能力。在COD小于400mg/L时,浮萍并未受到氧化胁迫;当COD达到800 mg/L时,浮萍体内ROS含量上升,细胞膜脂过氧化加剧,但抗氧化酶活性升高,抗氧化物质含量增加,浮萍可保持生长,胁迫去除后,抗氧化防御系统可恢复到对照水平;当COD过高(≥1 000mg/L),ROS急剧上升,抗氧化防御系统遭受破坏,造成不可逆伤害,胁迫去除后不能恢复正常生长。  相似文献   

6.
有机物降解产气率模型研究   总被引:1,自引:0,他引:1  
根据重庆市生活垃圾的组成特点,自配垃圾试样进行有机物降解实验,根据实验期间试样的质量变化,结合降解反应方程式,计算试样的产气量,并建立产气率模型.实验结果表明,试样质量随时间逐渐降低,呈指数型衰减规律.试样在实验初期产气率增加较快,达到产气高峰后逐渐降低.用建立的产气率模型进行计算,计算结果与实测数据比较接近,说明该产...  相似文献   

7.
The clearance volume between the piston, the cylinder and the top compression ring in an internal combustion engine has a significant effect on the unburned hydrocarbon concentration. The high heat transfer from the burning mixture to the cylinder surface extinguishes the flame front, and this is the main reason for increased unburned hydrocarbon concentrations. The heat transfer between the mixture and the clearance volume surface is affected by the ratio of coolant surface to the clearance volume. In this study the effect of the ratio of the coolant surface to the clearance volume on the unburned hydrocarbon concentration was investigated using three different purpose-built pistons. A decrease of this ratio reduced the unburned hydrocarbon concentration by 40%.  相似文献   

8.
Oleszczuk P 《Chemosphere》2007,70(2):288-297
The present study focuses on the influence of the composting process on the formation of potentially bioavailable and sequestrated PAH fractions. The potentially bioavailable fraction was determined by means of a mild-solvent extraction (with n-butanol). The total and potentially bioavailable PAH content was evaluated in the consecutive composting stages, i.e. at the onset of the experiment, after the stabilization phase (on the 35th day), and after the maturation phase (on the 76th day). Four municipal sewage sludges with differentiated PAH content were selected for the present experiment. Eleven PAHs from the US EPA list (with exception of naphthalene, acenaphthylene, acenaphtene, fluorene and benz[ah]anthracene) were determined for the purpose of this experiment. The content of the total PAHs ranged from 3052 to 10352microg kg(-1). The share of the potentially bioavailable fraction was at a similar level in the sludge samples tested and ranged from 75% to 81%. Greater differences were noted in the share of the bioavailable fraction in the case of individual PAH groups. The influence of the composting process on the contribution of the potentially bioavailable fraction of the PAH clearly depended on the stage of the experiment and sewage sludge type. However, in the case of all sludges, a lowering of the bioavailable fraction by 19-52% as compared to the level at the outset of the experiment was observed. During the first phase (stabilization) of the sewage sludge composting process, a reduction of the PAH content took place mainly at the expense of potentially bioavailable fraction, whereas in the second phase (maturation), sequestration processes predominated. The above phenomenon was most clearly visible for the 6-rings PAHs.  相似文献   

9.
汽车尾气净化催化剂的净化转化效果及其耐久性,与催化剂涂层的涂覆量以及涂层和载体的结合强度密切相关。本文研究了几种不同类型表面活性剂对浆料固体含量、涂层涂覆量以及涂层结合强度的影响。研究结果表明,不使用表面活性剂时,30%为最佳的固体含量;在使用表面活性剂的情况下,浆料的固体含量可以提高至35%。非离子型表面活性剂有助于提高催化剂涂层涂覆量,而使用离子型表面活性剂的浆料球磨过程中产生大量泡沫,无法涂覆。使用非离子型表面活性剂的催化剂涂层的结合强度最好。  相似文献   

10.
Spatio-temporal characteristics of PM10 concentration across Malaysia   总被引:1,自引:0,他引:1  
The recurrence of forest fires in Southeast Asia and associated biomass burning, has contributed markedly to the problem of trans-boundary haze and the long-range movement of pollutants in the region. Air pollutants, specifically particulate matter in the atmosphere, have received extensive attention, mainly because of their adverse effect on people's health. In this study, the spatial and temporal variability of the PM10 concentration across Malaysia was analyzed by means of the rotated principal component analysis. The results suggest that the variability of the PM10 concentration can be decomposed into four dominant modes, each characterizing different spatial and temporal variations. The first mode characterizes the southwest coastal region of the Malaysian Peninsular with the PM10 showing a peak concentration during the summer monsoon i.e. when the winds are predominantly southerlies or southwesterlies, and a minimal concentration during the winter monsoon. The second mode features the region of western Borneo with the PM10 exhibiting a concentration surge in August–September, which is likely to be the result of the northward shift of the Inter Tropical Convergence Zone (ITCZ) and the subsequent rapid arrival of the rainy season. The third mode delineates the northern region of the Malaysian Peninsular with strong bimodality in the PM10 concentration. Seasonally, this component exhibits two concentration maxima during the late winter and summer monsoons, as well as two minima during the inter-monsoon periods. The fourth dominant mode characterizes the northern Borneo region which exhibits weaker seasonality of the PM10 concentration. Generally, the seasonal fluctuation of the PM10 concentration is largely associated with the seasonal variation of rainfall in the country. However, in addition to this, the PM10 concentration also fluctuates markedly in two timescale bands i.e. 10–20 days quasi-biweekly (QBW) and 30–60 days lower frequency (LF) band of the intra-seasonal timescales. These intra-seasonal fluctuations show strong seasonality with the largest fraction of variance occurring during the boreal summer and the weakest variance during the winter. Generally, the LF intra-seasonal oscillation is stronger compared to the QBW intra-seasonal band.  相似文献   

11.
This paper presents a simplified analysis to determine the variables that affect the empirical correlation factor used in the lead peroxide method. The rate of sulfation has been determined from two different models. In the first model, the mass transfer rate is calculated from the gas phase resistance alone whereas in the second model, the diffusion resistance in the gel phase is assumed to be the rate limiting step. Although the gas phase and the gel phase resistances may be both important in the actual case, it has been found that the correlation factor based on the first model is adequate to describe general experimental observations. Reasonable agreement has been obtained between the measured and the calculated va|ue of the correlation factor.  相似文献   

12.
向一体式膜生物反应器中投加粉末活性炭(PAC),可以显著提高膜的过滤性能,有效缓解膜的污染.研究结果表明:投加PAC的吸附作用减少了由于胞外聚合物(EPS)而引起的膜污染;膜表面PAC颗粒的存在减小了浓差极化层的厚度和水力边界层的厚度,提高了过滤物质的传递速率;膜表面形成的PAC层还可过滤微生物和胶体颗粒,减少了它们到达膜表面的数量.  相似文献   

13.
In this paper we address two important aspects of micro-scale urban airflow model evaluation: (a) the identification of key flow features as dictated by the physics of the problem and as captured by the simulations, and (b) the comparison of important model output parameters (mean flows and fluctuations) with experimental data. A series of mesh-adaptive large eddy simulations (LES) was carried out for the study of air flows within two intersecting street canyons with varying building configurations. The novelty of the approach lies in the combination of LES with mesh adaptivity, which allows a variable-filter length and the implementation of an anisotropic eddy-viscosity model. Both coarse and fine-mesh simulations were carried out, using single and parallel-processor systems respectively. The simulations showed clearly that the expected flow patterns such as the street canyon recirculation and the street-mouth vortices, as well as the exchange of air flow at the street intersections, can readily be captured by the mesh-adaptive LES.In addition, the detailed comparisons of mean flows and fluctuations of the resolved velocity field with the measured data showed that the simulation results agreed well with the patterns and trends of the wind tunnel measurements. In most cases the finer-mesh simulations improved considerably the accuracy of the mean flows, especially for the symmetrical configuration. The improvement in the predicted fluctuations was less obvious, with several detector locations underpredicting the measured values, although the overall comparison was also satisfactory. The typical errors for the mean flows for all three building configurations were less than 30%, whilst for the velocity fluctuations less that 40%. Both the simulated means flows and turbulence levels were generally more accurate in the streets parallel to the wind (streamwise direction) than in the streets normal to the wind.  相似文献   

14.
The removal of hydrogen sulfide by oxidation-adsorption on two type carbon fibers, Actitex FC1201 and RS1301, was studied. Two kinetic steps where identified. During the first step, the degradation appears to be limited by the oxidation reaction. In the second kinetic step, the by-products inhibit the hydrogen sulfide degradation. This leads to a limitation in the carbon site's accessibility and to a lower kinetic. The Langmuir-Hinshelwood model was used to correlate the experimental results and to estimate the kinetic (k) and the Langmuir adsorption (K) constants. For FC1201 fibers, the kinetic constant (k) is five time higher and the adsorption constant is five time lower compared to the RS1301 fibers. The role of the humidity was found to be highly beneficial for the removal of hydrogen sulfide. Especially in the second kinetic step, where it removes the by-product formed and therefore delays the occurrence of this low kinetic step. The kinetic constant (k) is strongly influenced by humidity while the Langmuir adsorption constant (K) seems independent. The effect of the nature of the gas phase on the reaction kinetic was also studied. Under a dry atmosphere, we note that the oxidation-reaction occurs even if the gaseous oxygen is not present. This oxidation is due to the oxygen surface function of the carbon fibers. Moreover, the degradation kinetic is faster under a dry nitrogen atmosphere. The presence of water traces leads to the acidification of the carbon surface, under oxygen or carbon dioxide atmospheres, and hence limits the hydrogen sulfide dissociation. In a humid atmosphere, the oxygen or carbon dioxide leads to a faster reaction kinetic. The acidification of the carbon surface is largely counterbalanced by the dissolution of the by-products.  相似文献   

15.
Eutrophication is an ongoing process in most parts of the Baltic Sea. This article reports on the changes during recent decades of several eutrophication-related variables in the open sea areas surrounding Finland (wintertime nutrient concentrations, wintertime nutrient ratios, and summer time chlorophyll alpha concentrations at the surface). The sum of nitrate- and nitrite-nitrogen ([NO3+NO2]-N) was observed to increase nearly fourfold in the Northern Baltic Proper and the Gulf of Finland and almost double in the Bothnian Sea from the 1960s until the 1980s or 1990s. The increase was followed by a decrease, which was modest in the two former subregions. Phosphate-phosphorus (PO4-P) concentrations followed a similar pattern in the Northern Baltic Proper (threefold increase and subsequent slight decrease) and Bothnian Sea (30% increase and subsequent decrease), but increased throughout the study in the Gulf of Finland, with the present concentration being threefold to the measurements made in the early 1970s. The PO4-P concentration decreased throughout the study in the Bothnian Bay. Silicate-silicon (SiO4-Si) concentrations decreased 30-50% from the early 1970s to the late 1990s and increased 20-40% thereafter in the Northern Baltic Proper, the Gulf of Finland, and the Bothnian Sea. Chlorophyll alpha showed an increase of over 150% in the Northern Baltic Proper and the Gulf of Finland from the 1970s until the early 2000s. In the Bothnian Sea the chlorophyll alpha concentration increased more than 180% from the late 1970s until the late 1990s, and decreased thereafter. According to these long-term observations, the Gulf of Finland and Northern Baltic Proper show clear signs of eutrophication, which may be emphasized by hydrographical changes affecting the phytoplankton communities and thus the algal biomass.  相似文献   

16.
The article presents the results of research into the content of metalloid fractions in the tsunami deposits from southern Thailand. The following fractions, which are potentially most easily released from deposits to the environment, have been distinguished: the water soluble fraction, the exchangeable fraction extracted with the phosphate buffer and the fraction eluted with the solution of hydrochloric acid. The analytical technique atomic absorption spectrometry with hydride generation was applied. Spatial variability of the metalloid fractions in deposits and changes occurring in deposits over a period of several years of observation were determined. Based on the statistical analysis of the results, an attempt was made to determine the post-depositional release of deposits components to the environment. Based on the conducted research, the 4 years forming process of the arsenic, antimony and selenium occurrence after the deposition of sediments on land were described, as well as the balance in the amount of deposit components released to the environment.  相似文献   

17.
An investigation of a tetrachloroethene (PCE) groundwater plume originating at a dry cleaning facility on a sand aquifer and discharging to a river showed that the near-river zone strongly modified the distribution, concentration, and composition of the plume prior to discharging into the surface water. The plume, streambed concentration, and hydrogeology were extensively characterized using the Waterloo profiler, mini-profiler, conventional and driveable multilevel samplers (MLS), Ground Penetrating Radar (GPR) surveys, streambed temperature mapping (to identify discharge zones), drivepoint piezometers, and soil coring and testing. The plume observed in the shallow streambed deposits was significantly different from what would have been predicted based on the characteristics of the upgradient plume. Spatial and temporal variations in the plume entering the near-river zone contributed to the complex contaminant distribution observed in the streambed where concentrations varied by factors of 100 to 5000 over lateral distances of less than 1 to 3.5 m. Low hydraulic conductivity semi-confining deposits and geological heterogeneities at depth below the streambed controlled the pattern of groundwater discharge through the streambed and influenced where the plume discharged into the river (even causing the plume to spread out over the full width of the streambed at some locations). The most important effect of the near-river zone on the plume was the extensive anaerobic biodegradation that occurred in the top 2.5 m of the streambed, even though essentially no biodegradation of the PCE plume was observed in the upgradient aquifer. Approximately 54% of the area of the plume in the streambed consisted solely of PCE transformation products, primarily cis-1,2-dichloroethene (cDCE) and vinyl chloride (VC). High concentrations in the interstitial water of the streambed did not correspond to high groundwater-discharge zones, but instead occurred in low discharge zones and are likely sorbed or retarded remnants of past high-concentration plume discharges. The high-concentration areas (up to 5529 microg/l of total volatile organics) in the streambed are of ecological concern and represent potential adverse exposure locations for benthic and hyporheic zone aquatic life, but the effect of these exposures on the overall health of the river has yet to be determined. Even if the upgradient source of PCE is remediated and additional PCE is prevented from reaching the streambed, the high-concentration deposits in the streambed will likely take decades to hundreds of years to flush completely clean under natural conditions because these areas have low vertical groundwater flow velocities and high retardation factors. Despite high concentrations of contaminants in the streambed, PCE was detected in the surface water only rarely due to rapid dilution in the river and no cDCE or VC was detected. Neither the sampling of surface water nor the sampling of the groundwater from the aquifer immediately adjacent to the river gave an accurate indication of the high concentrations of PCE biodegradation products present in the streambed. Sampling of the interstitial water of the shallow streambed deposits is necessary to accurately characterize the nature of plumes discharging to rivers.  相似文献   

18.
Sterner H 《Ambio》2005,34(2):151-156
Eutrophication in the coastal waters of the northern part of the Swedish west coast is causing structural and functional changes to the coastal ecosystems. Large-scale mussel farming is proposed in the Program of Measures, required by the EU Water Framework Directive to reduce the nutrients in the coastal water and improve water quality over a transition period of 10-20 years. Ownership, land parcelling, conflicts of interest, and the protection of coastal water are obstructing accessibility to suitable water areas for the establishment of mussel farming plants. This paper studies the obstacles and possibilities in the relevant laws and legal regulations governing the accessibility to coastal waters for large-scale mussel farming. Alternative ways to solve the problem are shown and discussed, within the framework of the Planning and Building Act, the Environmental Code and the laws concerning land-parceling and property. It is shown that the Planning and Building Act, when used in a proper manner, can provide useful instruments for society to gain access to coastal water for mussel farming plants with the purpose of improving the ecological status of the water.  相似文献   

19.
Combining a computational fluid dynamics (CFD) model and a multi-zonal model, a study was carried out on radon entry through the complex substructure of a house with a cellar. The uniqueness of the radon entry problem in this type of house was due to the involvement of two radon entry routes to two chambers: the cellar and the living area of the house. Soil gas carrying radon was driven through the two routes by two coupled disturbance pressures in the chambers. The effects of temperature differences were considered as another driving force for the radon entry. Examined in this study were the effects of the geometry of the substructure, air permeability of the soil, air-tightness of the cellar shell, and cellar ventilation on radon entry to both the cellar and the living area. The ground floor covering on top of the soil outside a cellar wall increased radon entry through this wall by about 68%, as radon built up to a very high level under the covering. The effect of cellar ventilation was found as follows: the cellar ventilation created a layer of airflow in the soil under the ground floor; the flow passed over a crack in the ground floor, the entry route to the living area, diluting the radon in the area. Hence, the soil gas entering the living area carried less radon. Cellar ventilation seems more effective in reducing radon entry to the living area in a more permeable soil and leaky cellar shell; a moderate cellar ventilation condition achieved 77% reduction in radon entry to the area. When permeability of these two materials was lower and soil radon content remained the same, the chances of radon entry was also lower; hence, the indoor radon level was lower and no radon control was needed. When such soil contains high radon concentration, other mitigation measures must be sought.  相似文献   

20.
The Balcova Geothermal Field (BGF) located in Izmir, Turkey is situated on an east-west directed graben plain within which the hot waters surface from a fault zone that cuts the Mesozoic aged Bornova Flysch. Due to the low permeability and porosity of the Bornova Flysch, the geothermal water cycles along the immediate vicinity of the Agamemnon fault and mixes with cold waters at different depths of this fractured zone. Within the scope of this study, the mixing patterns and the groundwater contamination mechanisms are analyzed by, hydrogeological and hydrogeochemical methods. Based on the results of this research, it has been found out that the hot geothermal water and the cold regional groundwater resources of the surficial aquifer mix within the fractured zone in Bornova Flysch and within the Quaternary alluvium aquifer due to natural and anthropogenic activities including (i) the natural upward movement of geothermal fluid along the fault line, (ii) the accelerated upward seepage of geothermal fluid from faulty constructed boreholes drilled in the area, (iii) the faulty reinjection applications; and, (iv) the uncontrolled discharge of waste geothermal fluid to the natural drainage network. As a result of these activities, the cold groundwater reserves of the alluvial aquifer are contaminated thermally and chemically in such a way that various toxic chemicals including arsenic, antimony and boron are introduced to the heavily used surficial aquifer waters hindering their use for human consumption and agricultural irrigation. Furthermore, the excessive pumping from the surficial aquifer as well as the reduced surface water inflow into BGF due to the dam constructed on Ilica Creek intensify the detrimental effects of this contamination. Based on the results of this study, it can be concluded that the groundwater pollution in BGF will expand and reach to the levels of no return unless a series of preventive measures is taken immediately.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号