首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
In this study, removing sulfur dioxide (SO2), nitrogen oxides (NO(x)), and mercury (Hg) from simulated flue gas was investigated in two laboratory-sized bubbling reactors that simulated an oxidizing reactor (where the NO and Hg(0) oxidation reactions are expected to occur) and a wet limestone scrubber, respectively. A sodium chlorite solution was used as the oxidizing agent. The sodium chlorite solution was an effective additive that enhanced the NO(x), Hg, and SO2 capture from the flue gas. Furthermore, it was discovered that the location of the sodium chlorite application (before, in, or after the wet scrubber) greatly influences which pollutants are removed and the amount removed. This effect is related to the chemical conditions (pH, absence/presence of particular gases) that are present at different positions throughout the flue gas cleaning system profile. The research results indicated that there is a potential to achieve nearly zero SO2, NO(x), and Hg emissions (complete SO2, NO, and Hg removals and -90% of NO(x) absorption from initial values of 1500 ppmv of SO2, 200 ppmv of NO(x), and 206 microg/m3 of Hg(0)) from the flue gas when sodium chlorite was applied before the wet limestone scrubber. However applying the oxidizer after the wet limestone scrubber was the most effective configuration for Hg and NO(x) control for extremely low chlorite concentrations (below 0.002 M) and therefore appears to be the best configuration for Hg control or as an additional step in NO(x) recleaning (after other NO(x) control facilities). The multipollutant scrubber, into which the chlorite was injected simultaneously with the calcium carbonate slurry, appeared to be the least expensive solution (when consider only capital cost), but exhibited the lowest NO(x) absorption at -50%. The bench-scale test results presented can be used to develop performance predictions for a full- or pilot-scale multipollutant flue gas cleaning system equipped with wet flue gas desulfurization scrubber.  相似文献   

2.
Xu X  Chang SG 《Chemosphere》2007,67(8):1628-1636
The addition of metal chelates such as Fe(II)EDTA or Fe(II)Cit to wet flue gas desulfurization systems has been shown to increase the amount of NO(x) absorption from gas streams containing SO(2). This paper attempts to demonstrate the advantage of not only using Fe(II)Cit chelate to absorb nitrogen oxides from flue gas but also the advantage gained from adding microorganisms to the system. Two distinct classes of microorganisms are needed: denitrifying and iron-reducing bacteria. The presence of oxygen in flue gas will affect the absorption efficiency of NO by Fe(II)Cit chelate. The oxidation of Fe(II) can be slowed with the help of bacteria in two ways: bacteria can serve to directly reduce Fe(III) to Fe(II) or they can serve to keep levels of dissolved oxygen in the solution low. As a result, after NO absorption, Fe(II)(Cit)NO will be reduced by denitrifying bacteria to Fe(II)Cit while Fe(III) is reduced by anaerobic bacteria back to Fe(II). Our experiments have shown that the implementation of our protocol allowed for an NO reduction rate constant increase from standard levels of 0.0222-0.100 m Mh(-1) with inlet NO changed from 250 to 1000 ppm. We have also found that total Fe concentration tends to decrease after prolonged periods of operation due to the loss of some Fe to the formation of Fe(OH)(3) that settles together with the sludge at the bottom of bioreactor tank.  相似文献   

3.
采用杂多酸化合物溶液同时脱硫脱氮的实验研究   总被引:3,自引:0,他引:3  
本文对液相催化氧化脱硫脱氮的新方法进行了研究 ,在鼓泡反应发生器内进行了液相催化氧化脱硫脱氮的实验。采用钼硅酸溶液及其还原产物脱除烟气中的SO2 和NOX,分别就吸收液的浓度、pH值、温度、停留时间等因素对SO2 和NOX 去除效率的影响及其变化规律进行了研究。实验结果表明 ,钼硅酸能十分有效地吸收SO2 ,将SO2 氧化成H2 SO4,并使杂多酸还原为杂多蓝。随后又被用于去除NOX,把NOX 还原成N2 ,蓝色溶液再次被氧化成为黄色溶液  相似文献   

4.
Catalyst sorbents based on alumina-supported CuO, CeO2, and CuO-CeO2 were applied to a dry scrubber to clean up the SO2/HCl/NO simultaneously from pilot-scale fluidized-bed incineration flue gas. In the presence of organic compounds, CO and the submicron particles SO2 and HCI removed by the fresh catalyst sorbents and NO reduced to N2 by NH3 under the catalysis of fresh and spent desulfurization/dechloridization (DeSO2/DeHCl) catalyst sorbents (copper compounds, Cu, CuO, and CuSO4) were evaluated in this paper. The fresh and spent catalyst sorbents were characterized by the Brunner-Emmett-Teller method (BET), X-ray powder diffraction (XRPD), scanning electron microscopy (SEM), inductively coupled plasma-mass spectrometry (ICP-MS), and the elemental analyzer (EA). The study showed that the performances of CuO, CeO2, and CuO-CeO2/gamma-Al2O3 were better than that of Ca(OH)2. The removal efficiency of SO2 and HCl was 80-95% in the dry scrubber system. Under NH3/NO = 1, NO could not be reduced to N2 because it was difficult to control the ratio of air/fuel in the flue gas. For estimating the feasibility of regenerating the spent catalyst sorbents, BET and EA analyses were used. They indicated that the pore structures were nearly maintained and a small amount of carbon accumulated on their surface.  相似文献   

5.
采用K2Cr2O7溶液作为吸收液,在自制的鼓泡反应器内,对模拟烟气进行同时脱硫脱硝的实验研究,考察多种因素对SO2脱除率(即脱硫率)和NO脱除率(即脱硝率)的影响。实验结果表明:K2Cr2O7浓度、反应温度、NO浓度、SO2浓度、烟气流量对脱硫率、脱硝率影响显著;当烟气流量为0.4L/min,气相中O2体积分数为6%,SO2体积分数为0.09%,NO体积分数为0.100%,K2Cr2O7摩尔浓度为10mmol/L,反应温度为40℃时,脱硫率、脱硝率分别达到100%和64.3%。  相似文献   

6.
Gaseous elemental and total (elemental + oxidized) mercury (Hg) in the flue gas from a coal-fired boiler was measured by a modified ultraviolet (UV) spectrometer. Challenges to Hg measurement were the spectral interferences from other flue gas components and that UV measures only elemental Hg. To eliminate interference from flue gas components, a cartridge filled with gold-coated sand removed elemental Hg from a flue gas sample. The Hg-free flue gas was the reference gas, eliminating the spectral interferences. To measure total Hg by UV, oxidized Hg underwent a gas-phase, thermal-reduction in a quartz cell heated to 750 degrees C. Simultaneously, hydrogen was added to flash react with the oxygen present forming water vapor and preventing Hg re-oxidation as it exits the cell. Hg concentration results are in parts per billion by volume Hg at the flue gas oxygen concentration. The modified Hg analyzer and the Ontario Hydro method concurrently measured Hg at a field test site. Measurements were made at a 700-MW steam turbine plant with scrubber units and selective catalytic reduction. The flue gas sampled downstream of the selective catalytic reduction contained 2100 ppm SO2 and 75 ppm NOx. Total Hg measured by the Hg analyzer was within 20% of the Ontario Hydro results.  相似文献   

7.
Oxides of nitrogen (NOx) [nitrogen oxide (NO) + nitrogen dioxide (NO2)] and sulfur dioxide (SO2) are removed individually in traditional air pollution control technologies. This study proposes a combined plasma scrubbing (CPS) system for simultaneous removal of SO2 and NOx. CPS consists of a dielectric barrier discharge (DBD) and wet scrubbing in series. DBD is used to generate nonthermal plasmas for converting NO to NO2. The water-soluble NO2 then can be removed by wet scrubbing accompanied with SO2 removal. In this work, CPS was tested with simulated exhausts in the laboratory and with diesel-generator exhausts in the field. Experimental results indicate that DBD is very efficient in converting NO to NO2. More than 90% removal of NO, NOx, and SO2 can be simultaneously achieved with CPS. Both sodium sulfide (Na2S) and sodium sulfite (Na2SO3) scrubbing solutions are good for NO2 and SO2 absorption. Energy efficiencies for NOx and SO2 removal are 17 and 18 g/kWh, respectively. The technical feasibility of CPS for simultaneous removal of NO, NO2, and SO2 from gas streams is successfully demonstrated in this study. However, production of carbon monoxide as a side-product (approximately 100 ppm) is found and should be considered.  相似文献   

8.
二氧化硫和氮氧化物是电厂产生的主要大气污染物,研究焦点越来越集中在在一个反应器内实现同时脱硫脱硝。实验以H2O溶液作为吸收液,在自制的鼓泡反应器内,对模拟烟气进行同时脱硫脱硝的实验研究,实验结果表明:H2O浓度、反应温度、NO浓度、SO2浓度、烟气流量对脱除率影响显著,pH、氧含量对脱硝率影响不大。在整个实验范围内脱硫效率总是保持在98.5%以上,脱硝效率最高达到67.4%。  相似文献   

9.
Removal of ammonia solutions used in catalytic wet oxidation processes   总被引:9,自引:0,他引:9  
Hung CM  Lou JC  Lin CH 《Chemosphere》2003,52(6):989-995
Ammonia (NH(3)) is an important product used in the chemical industry, and is common place in industrial wastewater. Industrial wastewater containing ammonia is generally either toxic or has concentrations or temperatures such that direct biological treatment is unfeasible. This investigation used aqueous solutions containing more of ammonia for catalytic liquid-phase oxidation in a trickle-bed reactor (TBR) based on Cu/La/Ce composite catalysts, prepared by co-precipitation of Cu(NO(3))(2), La(NO(3))(2), and Ce(NO(3))(3) at 7:2:1 molar concentrations. The experimental results indicated that the ammonia conversion of the wet oxidation in the presence of the Cu/La/Ce composite catalysts was determined by the Cu/La/Ce catalyst. Minimal ammonia was removed from the solution by the wet oxidation in the absence of any catalyst, while approximately 91% ammonia removal was achieved by wet oxidation over the Cu/La/Ce catalyst at 230 degrees C with oxygen partial pressure of 2.0 MPa. Furthermore, the effluent streams were conducted at a liquid hourly space velocity of under 9 h(-1) in the wet catalytic processes, and a reaction pathway was found linking the oxidizing ammonia to nitric oxide, nitrogen and water. The solution contained by-products, including nitrates and nitrites. Nitrite selectivity was minimized and ammonia removal maximized when the feed ammonia solution had a pH of around 12.0.  相似文献   

10.
电子束烟气脱硫技术工业示范工程进展   总被引:1,自引:0,他引:1  
处理成都电厂200MW机组锅炉的30万Nm3/h烟气。它是目前世界上已投入运行的处理烟气量最大的电子束脱硫装置。其脱硫率及脱硝率均超过80%及10%的设计值,各项运行消耗指标均低于设计值。处理过程为干法,无废水废渣,副产品硫(硝)铵可用作化肥。该装置的自动化程度较高,操作简便,对烟气SO2浓度及烟气量的变化有较好的适应性和负荷跟踪性。烟气中残氨浓度及周围的辐射剂量低于国家标准的规定。  相似文献   

11.
This work considers the oxidation of ammonia (NH3) by selective catalytic oxidation (SCO) over a copper (Cu)-cerium (Ce) composite catalyst at temperatures between 150 and 400 degrees C. A Cu-Ce composite catalyst was prepared by coprecipitation of copper nitrate and cerium nitrate at various molar concentrations. This study also considers how the concentration of influent NH3 (500-1000 ppm), the space velocity (72,000-110,000 hr(-1)), the relative humidity (12-18%) and the concentration of oxygen (4-20%) affect the operational stability and the capacity for removing NH3. The effects of the O2 and NH3 content of the carrier gas on the catalyst's reaction rate also are considered. The experimental results show that the extent of conversion of NH3 by SCO in the presence of the Cu-Ce composite catalyst was a function of the molar ratio. The NH3 was removed by oxidation in the absence of Cu-Ce composite catalyst, and approximately 99.2% NH3 reduction was achieved during catalytic oxidation over the Cu-Ce (6:4, molar/molar) catalyst at 400 degrees C with an O2 content of 4%. Moreover, the effect of the initial concentration and reaction temperature on the removal of NH3 in the gaseous phase was also monitored at a gas hourly space velocity of less than 92,000 hr(-1).  相似文献   

12.
利用垃圾渗滤液中较高的碱度吸收二氧化硫是垃圾渗滤液湿法烟气脱硫工艺的第一阶段。试验证明 ,垃圾渗滤液可高效吸收二氧化硫 (去除率可达 90 %以上 ) ;同时垃圾渗滤液中氨氮浓度由 133mmol L降至 78mmol L。实验结果证实了所建立的垃圾渗滤液烟气脱硫体系的互补性  相似文献   

13.
Concepts for controlling SO2 from fossil fuels can be separated into two main categories: (1) Residual and vacuum gas oil desulfurization and (2) Flue gas desulfurization. The Kiyoura-T.I.T. process confines itself to the desulfurization of flue gas. It employs vandium oxide as a catalyst which oxidizes the sulfur dioxide to trioxide, followed by a gaseous phase reaction of ammonia. The end product, ammonium sulfate is removed by an electrostatic precipitator. (The details were presented at annual meetings of APCA in 1966 and 1967 as 1 and II.) Flue gas is passed through cyclone and dust filter to remove dust. Under normal operating conditions almost all of the dust is removed at the filters. The author carried out experiments to determine whether there was any effect on the activity of the catalyst, assuming that a portion of the dust escapes into the stream along the flue. It has been generally accepted that in fuel oil firing steam power plants, about 100 mg./nm3 of dust including carbon, hydrocarbon, and ash are normally contained in the flue stream. The carbon and hydrocarbon is oxidized readily at the filters and exists only as ash. An amount of ash equivalent to the amount assumed to have settled on the catalyst over a period of 3–12 months, was placed on the catalyst, and experiments were carried out. The SO2 conversion efficiency was measured and found to be over 93%. The results showed that at the actual operational temperature of 450°C, ash had practically no effect at all.  相似文献   

14.
亚铁螯合剂液相脱除烟气中NOx   总被引:9,自引:0,他引:9  
总结了近20多年来液相络合法脱除烟气中NOx的研究成果,详细叙述了亚铁氨羧和亚铁含-SH基二类螯合剂单独脱氮和同时脱硫脱氮的反应机理、动力学、吸收液的再生和过程的影响因素,指出了该工艺存在的主要问题,提出了今后的研究方向.  相似文献   

15.
A bench-scale reactor consisting of a natural gas burner and an electrically heated reactor housing a selective catalytic reduction (SCR) catalyst was constructed for studying elemental mercury (Hg(o)) oxidation under SCR conditions. A low sulfur Powder River Basin (PRB) subbituminous coal combustion fly ash was injected into the entrained-flow reactor along with sulfur dioxide (SO2), nitrogen oxides (NOx), hydrogen chloride (HCl), and trace Hg(o). Concentrations of Hg(o) and total mercury (Hg) upstream and downstream of the SCR catalyst were measured using a Hg monitor. The effects of HCl concentration, SCR operating temperature, catalyst space velocity, and feed rate of PRB fly ash on Hg(o) oxidation were evaluated. It was observed that HCl provides the source of chlorine for Hg(o) oxidation under simulated PRB coal-fired SCR conditions. The decrease in Hg mass balance closure across the catalyst with decreasing HCl concentration suggests that transient Hg capture on the SCR catalyst occurred during the short test exposure periods and that the outlet speciation observed may not be representative of steady-state operation at longer exposure times. Increasing the space velocity and operating temperature of the SCR led to less Hg(o) oxidized. Introduction of PRB coal fly ash resulted in slightly decreased outlet oxidized mercury (Hg2+) as a percentage of total inlet Hg and correspondingly resulted in an incremental increase in Hg capture. The injection of ammonia (NH3) for NOx reduction by SCR was found to have a strong effect to decrease Hg oxidation. The observations suggest that Hg(o) oxidation may occur near the exit region of commercial SCR reactors. Passage of flue gas through SCR systems without NH3 injection, such as during the low-ozone season, may also impact Hg speciation and capture in the flue gas.  相似文献   

16.
This paper is particularly related to elemental mercury (Hg0) oxidation and divalent mercury (Hg2+) reduction under simulated flue gas conditions in the presence of nitric oxide (NO) and sulfur dioxide (SO2). As a powerful oxidant and chlorinating reagent, Cl2 has the potential for Hg oxidation. However, the detailed mechanism for the interactions, especially among chlorine (Cl)-containing species, SO2, NO, as well as H2O, remains ambiguous. Research described in this paper therefore focused on the impacts of SO2 and NO on Hg0 oxidation and Hg2+ reduction with the intent of unraveling unrecognized interactions among Cl species, SO2, and NO most importantly in the presence of H2O. The experimental results demonstrated that SO2 and NO had pronounced inhibitory effects on Hg0 oxidation at high temperatures when H2O was also present in the gas blend. Such a demonstration was further confirmed by the reduction of Hg2+ back into its elemental form. Data revealed that SO2 and NO were capable of promoting homogeneous reduction of Hg2+ to Hg0 with H2O being present. However, the above inhibition or promotion disappeared under homogeneous conditions when H2O was removed from the gas blend.  相似文献   

17.
Goo JH  Irfan MF  Kim SD  Hong SC 《Chemosphere》2007,67(4):718-723
The selective catalytic reduction (SCR) characteristics of NO and NO(2) over V(2)O(5)-WO(3)-MnO(2)/TiO(2) catalyst using ammonia as a reducing agent have been determined in a fixed-bed reactor at 200-400 degrees C. The presence of NO(2) enhances the SCR activity at lower temperatures and the optimum ratio of NO(2)/NO(x) is found to be 0.5. During the SCR reactions, there are some side reactions occurred such as ammonia oxidation and N(2)O formation. At higher temperatures, the selective catalytic oxidation of ammonia and the nitrous oxide formation compete with the SCR reactions. The denitrification (DeNO(x)) conversion decreases at lower temperatures but it increases at higher temperatures with increasing SO(2) concentration. The presence of SO(2) in the feeds inhibits N(2)O formation.  相似文献   

18.
Air quality impacts of power plant emissions in Beijing   总被引:8,自引:0,他引:8  
The CALMET/CALPUFF modeling system was applied to estimate the air quality impacts of power plants in 2000 and 2008 in Beijing, and the intake fractions (IF) were calculated to see the public health risks posed. Results show that in 2000 the high emission contribution induced a relatively small contribution to average ambient concentration and a significant impact on the urban area (9.52 microg/m(3) of SO(2) and 5.29 microg/m(3) of NO(x)). The IF of SO(2), NO(x) and PM(10) are 7.4 x 10(-6), 7.4 x 10(-6) and 8.7 x 10(-5), respectively. Control measures such as fuel substitution, flue gas desulfurization, dust control improvement and flue gas denitration planned before 2008 will greatly mitigate the SO(2) and PM(10) pollution, especially alleviating the pressure on the urban area to reach the National Ambient Air Quality Standard (NAAQS). NO(x) pollution will be mitigated with 34% decrease in concentration but further controls are still needed.  相似文献   

19.
A novel process for removal of nitrogen oxides (NOx) from flue gases with iron filings reduction following complex absorption in iron-ethylenediaminetetraacetic acid aqueous solution is proposed. The reaction mechanism involved in the process is discussed briefly. The parameters influencing the process, including the concentration of ferrous chelates, initial pH, amount of iron filings, temperature, flow rate of the flue gas, and inlet nitric oxide concentration and oxygen content of the flue gas, are researched in detail. The optimal NOx removal conditions are established. The regeneration and circular utilization of the absorption solution also is studied.  相似文献   

20.
This paper presents a study on the simultaneous removal of SO2, NO(x) and Hg (both Hg0 and Hg2+) from a simulated flue gas by oxidant injection in a bench-simulated wet limestone scrubber for a wide range of slurry pH. The slurry pH strongly influenced the chemical mechanism in the scrubber and, therefore, affected pollutant removal. This paper also examines the potential ClO2(gas) reemission from a developed multipollutant scrubber at different slurry pHs. To better understand the chemical mechanisms at each slurry pH and to apply a mass balance to the process, detailed product ion analyses were performed for all experiments. Ion analysis covered three different chlorine species (chlorite, chloride, chlorate), sulfate, nitrite and nitrate. Different NO(x) removal efficiencies and mechanisms were found in acidic and alkaline pHs in the multipollutant scrubber. The acidic solution was favorable for NO and Hg0 oxidation, but increasing the slurry pH above 7.0 was disadvantageous for NO and Hg oxidation/removal. However the rate of NO(x) absorption (by percentage) was higher for the alkaline solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号