首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Chlorophenol compounds present in many chemical industry wastewaters are resistant to biological degradation because of the toxic effects of such compounds on microorganisms. Synthetic wastewater containing different concentrations of 2,4 dichlorophenol (DCP) was subjected to biological treatment in an activated sludge unit. Effects of feed DCP concentration on COD, DCP, and toxicity removals and on sludge volume index were investigated at a constant sludge age of 10 days and hydraulic residence time (HRT) of 25 h. The Resazurin method based on dehydrogenase activity was used for assessment of toxicity for the feed and effluent wastewater. Percent COD, DCP, and toxicity removals decreased and the effluent COD, DCP, and toxicity levels increased with increasing feed DCP concentrations above 150 mgl(-1) because of inhibitory effects of DCP. Biomass concentration in the aeration tank decreased and the sludge volume index (SVI) increased with feed DCP concentrations above 150 mgl(-1) resulting in lower COD and DCP removal rates. The system should be operated at feed DCP concentrations of less than 150 mgl(-1) in order to obtain high COD, DCP, and toxicity removals.  相似文献   

2.
Due to the toxic effects of trichlorophenol (TCP) on microorganisms, biological treatment efficiencies of TCP containing wastewaters are usually low. Synthetic wastewater containing 2,4,6-TCP was biologically treated in a hybrid-loop bioreactor system consisting of a packed column biofilm and an aerated tank bioreactor with effluent recycle in order to improve COD and TCP removals. Effects of the feed TCP concentration on COD, TCP and toxicity removal performance of the system were investigated for the feed TCP between 50 and 450 mg L(-1) while the sludge age (solids retention time, SRT) and hydraulic residence time (HRT) were kept constant at 20 d and 25 h, respectively. Biomass concentrations in the packed column and in the aeration tank decreased with increasing feed TCP concentrations due to toxic effects of TCP on the organisms. Low biomass concentrations in the system at high feed TCP contents resulted in low COD, TCP and toxicity removals. Therefore, percent TCP, COD and toxicity removals decreased with increasing feed TCP concentrations especially above 400 mg L(-1). The effluent TCP concentrations were lower than 20 mg L(-1) for the feed TCP concentrations below 390 mg L(-1) resulting in TCP and COD removals above 90%. Specific rates of TCP and COD removals increased with the feed TCP due to low biomass concentrations at high TCP contents. The system should be operated at a feed TCP lower than 400 mg L(-1) in order to obtain more than 90% TCP, COD and toxicity removals under the specified experimental conditions.  相似文献   

3.
Biological treatment of landfill leachate usually results in low nutrient removals because of high chemical oxygen demand (COD), high ammonium-N content and the presence of toxic compounds such as heavy metals. Landfill leachate with high COD content was pre-treated by coagulation-flocculation with lime followed by air stripping of ammonia at pH=12. Nutrient removal from pre-treated leachate was carried out using a lab-scale sequencing batch reactor (SBR). Three different operations consisting of different numbers of steps were tested and their performances were compared. These operations were the three-step anaerobic (An)/anoxic (Ax)/oxic (Ox); the four-step (An/Ox/Ax/Ox), and the five-step (An/Ax/Ox/Ax/Ox) operations with total residence time of seven hours each. Experiments were carried out using three consecutive operations with a total cycle time of 21 h at a constant sludge age of 10 days. The lowest effluent nutrient levels were realized by using the five-step operation which resulted in effluent COD, NH4-N and PO4-P contents of 1,400, 107 and 65 mg l(-1), respectively, at the end of 21 h. Addition of domestic wastewater (1/1, v/v) and powdered activated carbon (PAC, 1 g l(-1)) to the pre-treated leachate improved nutrient removals in the five-step SBR operation, resulting in 75% COD, 44% NH4-N and 44% PO4-P removals after 21 hours of operation.  相似文献   

4.
Leachate generated in a landfill may not be treated by conventional biological treatment due to its nature and complexity. The process of forming aerobic granules in batch sequencing reactors having features such as; reducing the settling process time and saving energy consumption and high decomposition rate have been noticed by researchers. In the present study, the structure of sequencing batch reactors (SBRs) was evaluated for the formation of granules, which were subsequently utilized for the treatment of landfill leachate. The experiment was initiated by using the GSBR, containing 1200 ml with different apparatuses, to develop granular sludge, and synthetic wastewater was added to reinforcement. The selected parameters for the operational hydraulic retention time (HRT) of the wastewater (6-h cycles) included feeding, idle, aeration, settling, and discharge. Furthermore, the controlled conditions were the dissolved oxygen (DO) range of 2–2.2 mg/L, temperature range of 20–23℃, and pH of 7.5–8.3. The chemical oxygen demand (COD), mixed liquor suspended solids (MLSS), and sludge volume index (SVI) daily were measured at the influent and effluent of GSBR reactor. The main properties of aerobic granular sludge were identified during the research procedures, and the remarkable settling and potent, high-density microbial structure of the granules were confirmed. The mean size of the formulated granules was estimated at 7.46 ± 1.8 mm, and the volume of the biomass also increased from approximately 1607 to 4137 mg/L through the granulation process. Moreover, 98% of the influent chemical oxygen demand (COD) could be removed by the formulated granular sludge, and the final-stage organic loading rate was estimated at 5.65 COD/m3/day. According to the results, GSBRs could be employed for the formulation of aerobic granular sludge for the treatment of landfill leachate.  相似文献   

5.
A pre-denitrification activated sludge system (AS) without internal recycle was used in lab-scale studies of landfill leachate treatment. A bentonite supplement at a ratio of 1:4 (mineral : biomass) was used to ensure high sludge settling levels and to serve as a micro-organisms carrier. The system was operated within different parameters such as hydraulic retention time (HRT), ammonia loading rate (ALR) or external recycle ratio, which was adapted to treat varying leachate concentrations of COD and ammonia, ranging from 1020 to 2680 mgO(2)l(-1) and 400-890 mgNH(4)-Nl(-1) respectively. The nitrification was complete and ammonia oxidation reached 99%; this was obtained while the ALR did not exceed 0.09 g NH(4)(+)-Ng(-1)MLVSS d(-1) and HRT was not lower than 1 day (in the aeration reactor). The performance of denitrification was successfully improved by controlling the external recycle rate, when the BOD(5)/N ratio in the raw leachate was 4.1. Consequently, N-removal of up to 80% was achieved. A 10-fold decrease in the denitrification rate was obtained at a BOD(5)/N ratio of 0.5. The efficiency of COD removal varied significantly from 36% to 84%. The positive effect of bentonite addition was determined and is discussed based on preliminary studies. The experiments were carried out in fill-and-draw activated sludge with bentonite; the biomass ratio was 1:2. The activated sludge with bentonite was fed with a synthetic high ammonia and organic-free medium.  相似文献   

6.
This paper addresses the treatment of purified terephthalic acid (PTA) effluent using anaerobic and aerobic processes. Laboratory studies were carried out on flow proportionate composite wastewater generated from the manufacturing of PTA. An activated sludge process (ASP-two stage and single stage) and an upflow anaerobic fixed film fixed bed reactor (AFFFBR) were used, individually and in combination. The performance of a full-scale ETP under existing operating conditions was also studied. Full scale ETP studies revealed that the treatment of PTA effluent using a two-stage ASP alone does not meet treated effluent quality within the prescribed Indian Standards. The biomass produced in the two stage ASP was very viscous and fluffy and the sludge volume index (SVI) was very high (200-450 ml/g). However, pretreatment of PTA effluent using an upflow AFFFBR ensured substantial reduction in BOD (63%) and COD (62%) with recovery of biogas at 1.8-1.96 l/l effluent treated at a volumetric loading rate (VLR) 4-5 kg COD/m(3) d. The methane content in the biogas varied between 55% and 60%. The pretreated effluent from the upflow AFFFBR was then treated through a single stage ASP. The biomass produced in the ASP after anaerobic treatment had very good settlability (SVI: 75-90 ml/g) as compared to the two stage ASP and the treated effluent quality with respect to BOD, COD and SS was within the prescribed Indian Standards. The alternative treatment process comprising an upflow AFFFBR and a single stage ASP ensured net power saving of 257 kW and in addition generated 442 kW of power through the AFFFBR.  相似文献   

7.
Treatment of low-strength soluble wastewater (COD approximately 500 mg/L) was studied using an eight chambered anaerobic baffled reactor (ABR). At pseudo steady-state (PSS), the average total and soluble COD values (COD(T) and COD(S)) at 8h hydraulic retention time (HRT) were found to be around 50 and 40 mg/L, respectively, while at 10h HRT average COD(T) and COD(S) values were of the order of 47 and 37 mg/L, respectively. COD and BOD (3 day, 27 degrees C) removal averaged more than 90%. Effluent conformed to Indian standards laid down for BOD (less than 30 mg/L). Reactor effluent characteristics exhibited very low values of standard deviation indicating excellent reactor stability at PSS in terms of effluent characteristics. Based on mass balance calculations, more than 60% of raw wastewater COD was estimated to be recovered as CH(4) in the gas phase. Compartment-wise profiles indicated that most of the BOD and COD got reduced in the initial compartments only. Sudden drop in pH (7.8-6.7) and formation of volatile fatty acids (VFA) (53-85 mg/L) were observed in the first compartment due to acidogenesis and acetogenesis. The pH increased and VFA concentration decreased longitudinally down the reactor. Residence time distribution (RTD) studies revealed that the flow pattern in the ABR was neither completely plug-flow nor perfectly mixed. Observations from scanning electron micrographs (SEM) suggest that distinct phase separation takes place in an ABR.  相似文献   

8.
Thiocyanate (SCN) compounds in photo-processing wastewater (PPWW) could be treated by an SBR system without any release of thiocyanate to the atmosphere during the aeration step. An SCN loading greater than 84 g m(-3)d(-1) showed negative effects on the growth of bio-sludge and removal efficiencies of the system. The acclimatization period of the system was increased with an increase in SCN concentration or loading. The COD, BOD(5), TKN, and SCN removal efficiencies were 96.0 +/- 1.6%, 72 +/- 2%, 49 +/- 5%, and 82 +/- 3%, respectively, under an SCN loading of up to 84 g m(-3)d(-1). The removal efficiency of the system was repressed by SCN due to the repressed growth rate of nitrification bacteria. However, the removal efficiency could be increased with an increase in HRT or a decrease in SCN loading. Also, increases in HRT or decreases in SCN loading led to increased sludge age or solid retention time (SRT) and decreased the sludge volume index (SVI) value. The SRT and SVI of the system with synthetic wastewater containing 840 mg l(-1) SCN under an HRT of 3 days (SCN loading of 280 g m(-3)d(-1)) were 3.9 +/- 0.7 days and 65 +/- 4 ml g(-1), respectively, while they were 11.2+/-0.8 days and 55 +/- 6 ml g(-1), respectively under an HRT of 10 days (SCN loading of 84 g m(-3)d(-1)).  相似文献   

9.
Pulp mill effluent was treated by different advanced oxidation processes (AOPs) consisting of UV, UV/H2O2, TiO2-assisted photo-catalysis (UV/TiO2) and UV/H2O2/TiO2 in lab-scale reactors for total organic carbon (TOC) and toxicity removals. Effects of some operating parameters such as the initial pH, oxidant and catalyst concentrations on TOC and toxicity removals were investigated. Almost every method resulted in some degree of TOC and toxicity removal from the pulp mill effluent. However, the TiO2-assisted photo-catalysis (UV/TiO2) resulted in the highest TOC and toxicity removals under alkaline conditions when compared with the other AOPs tested. Approximately, 79.6% TOC and 94% toxicity removals were obtained by the TiO2-assisted photo-catalysis (UV/TiO2) with a titanium dioxide concentration of 0.75gl(-1) at pH 11 within 60min.  相似文献   

10.
Wood processing effluents contain different types of phenolic compounds, from simple monomers to high molecular weight (MW) polyphenolic polymers, that can inhibit wastewater treatment. This work presents a comparative study of the methanogenic toxicity produced by three wood processing effluents (hardboard, fiberboard and BKME (kraft mill effluent)) using Pinus radiata, Eucalyptus and Tepa as feedstock (the last one being a native Chilean tree species). This study evaluates the influence of non-adapted granular and adapted flocculent sludge on forest industrial wastewater treatment as well as continuous anaerobic biodegradation of hardboard processing effluent using the upflow anaerobic sludge blanket (UASB). The adapted biomass (flocculent sludge) did not show any lag-phase signs. The 50% IC (the concentration causing 50% inhibition of methanogenic activity) was 4.3 g COD-effluent (chemical oxygen demand (COD)-of the effluent)/l and 2.8 g COD-effluent/l for the flocculent sludge and the granular sludge, respectively. The UASB system worked at low organic load rates (0.1-0.4 g COD/l d) with the COD removal ranging between 10 and 30%, and color removal did not occur under anaerobic conditions due to high MW. Indeed, the MW analysis indicates the presence of phenolic compounds over 25,000 Da in the anaerobic effluent.  相似文献   

11.
The production of highly polluting palm oil mill effluent (POME) has resulted in serious environmental hazards. While anaerobic digestion is widely accepted as an effective method for the treatment of POME, anaerobic treatment of POME alone has difficulty meeting discharge limits due to the high organic strength of POME. Hence, subsequent post-treatment following aerobic treatment is vital to meet the discharge limits. The objective of the present study is to investigate the aerobic treatment of anaerobically digested POME by using a sequencing batch reactor (SBR). The SBR performance was assessed by measuring Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD) and Total Suspended Solids (TSS) removal as well as Sludge Volume Index (SVI). The operating pH and dissolved oxygen concentrations were found to be 8.25–9.14 and 1.5–6.4 mg/L, respectively, throughout the experiment. The experimental results demonstrate that MLVSS, OLR and sludge loading rate (SLR) play a significant role in the organic removal efficiency of SBR systems and therefore, further investigation on these parameters was conducted to attain optimum SBR performance. Maximum COD (95–96%), BOD (97–98%) and TSS (98–99%) removal efficiencies were achieved at optimum OLR, SLR and MLVSS concentration ranges of 1.8–4.2 kg COD/m3 day, 2.5–4.6 kg TSS/m3 day and 22,000–25,000 mg/L, respectively. The effluent quality remained stable and complied with the discharge limit. At the same time, the sludge showed good settling properties with average SVI of 65. It is envisaged that the SBR process could complement the anaerobic treatment to produce final treated effluent which meets the discharge limit.  相似文献   

12.
In this study treatment of palm oil mill effluent (POME) was investigated using aerobic oxidation based on an activated sludge process. The effects of sludge volume index, scum index and mixed liquor suspended solids during the acclimatizing phase and biomass build-up phase were investigated in order to ascertain the reactor stability. The efficiency of the activated sludge process was evaluated by treating anaerobically digested and diluted raw POME obtained from Golden Hope Plantations, Malaysia. The treatment of POME was carried out at a fixed biomass concentration of 3900+/-200mg/L, whereas the corresponding sludge volume index was found to be around 105+/-5mL/g. The initial studies on the efficiency of the activated sludge reactor were carried out using diluted raw POME for varying the hydraulic retention time, viz: 18, 24, 30 and 36h and influent COD concentration, viz: 1000, 2000, 3000, 4000 and 5000mg/L, respectively. The results showed that at the end of 36h of hydraulic retention time for the above said influent COD, the COD removal efficiencies were found to be 83%, 72%, 64%, 54% and 42% whereas at 24h hydraulic retention time they were 57%, 45%, 38%, 30% and 27%, respectively. The effectiveness of aerobic oxidation was also compared between anaerobically digested and diluted raw POME having corresponding CODs of 3908 and 3925mg/L, for varying hydraulic retention time, viz: 18, 24, 30, 36, 42, 48, 54 and 60h. The dissolved oxygen concentration and pH in the activated sludge reactor were found to be 1.8-2.2mg/L and 7-8.5, respectively. The scum index was found to rise from 0.5% to 1.9% during the acclimatizing phase and biomass build-up phase.  相似文献   

13.
To gain more insight into the interactions between anaerobic bacteria and reactor performances (chemical oxygen demand-COD, 2,4 dichlorophenol-2,4 DCP removals, volatile fatty acid-VFA, and methane gas productions) and how they depended on operational conditions the microbial variations in the anaerobic granular sludge from an upflow anaerobic sludge blanket (UASB) reactor treating 2,4 DCP was studied. The study was composed of two parts. In the first part, the numbers of methanogens and acedogens in the anaerobic granular sludge were counted at different COD removal efficiencies. The relationships between the numbers of methanogens, the methane gas production and VFA production were investigated. The COD removal efficiencies increased to 74% from 30% while the number of total acedogens decreased to 10 from 30 cfu ml(-1). The number of total methanogens and acedogens varied between 11 x 10(3) and 10 x 10(9)MPN g(-1) and 10 and 30 cfu ml(-1) as the 2,4 DCP removal efficiencies were obtained between 60% and 99%, respectively. It was seen that, as the number of total acedogens decreased, the COD removal efficiencies increased. However, the number of total methanogens increased as the COD removal efficiencies increased. Correlations between the bacterial number and with the removal efficiencies obtained in different operational conditions were investigated. From the results presented in this paper a high correlation between the number of bacteria, COD removals, methane gas percentage, 2,4 DCP removals and VFA was observed. In the second part, methanogen bacteria in the anaerobic granular sludge were identified. Microbial observations and biochemical tests were applied to identify the anaerobic microorganisms from the anaerobic granular sludge. In the reactor treating 2,4 DCP, Methanobacterium bryantii, Methanobacterium formicicum, Methanobrevibacter smithii, Methanococcus voltae, Methanosarcina mazei, Methanosarcina acetivorans, Methanogenium bourgense and Methanospirillum hungatei were identified.  相似文献   

14.
A sequentially combined carbon (SCC) source using methanol and acetic acid was investigated for biological nitrogen and phosphorus removal in a wastewater treatment process consisting of an anoxic zone, an oxic zone and a final settling tank. The anoxic zone was divided into two separate anoxic zones to feed methanol in the first anoxic zone and acetic acid in the second anoxic zone. Methanol and acetic acid, each as the sole carbon source, were also tested for comparison. The use of SCC was superior in nitrogen removal with all combined COD ratios of methanol/acetic acid tested, yielding 95.8-97% efficiency (less than 1 mg N/l in the final effluent). The highest phosphorus removal of above 92% (final effluent concentration of 0.12 mg P/l) was achieved when only acetic acid was used at a quantity equivalent to 50 mg COD/l. However, when SCC was used, the acetic acid dosage of 50 mg COD/l could be reduced down to 20 mg COD/l when 30 mg COD/l was replaced by methanol; this resulted in a final effluent phosphorus concentration of 0.6 mg P/l. Additional benefits of SCC included the excellent sludge settling properties compared to the use of methanol or acetic acid alone.  相似文献   

15.
A moving bio-film (MB), made from the inner tube of used tyres was applied in a conventional-aerobic-SBR for increasing the system efficiency and quality of bio-sludge due to good sedimentation (the density of 1.925+/-0.21 g/cm(3)), non-biodegradability and re-usability of the media without any regeneration. The total bio-sludge mass of the MB-aerobic-SBR was about 30% higher than that of the conventional-aerobic-SBR resulting in a reduction of the F/M value of the system and amount of suspended bio-sludge waste. The amount of suspended bio-sludge waste, SVI and SRT of the MB-aerobic-SBR under a low organic loading of 80+/-9.3g BOD(5)/m(3)-d were 1,485+/-146 mg/d, 51+/-3.7 ml/g and 10.1+/-5.1 days, respectively while they were 1,800+/-152 mg/d, 69+/-4.0 ml/g and 8.3+/-5.3 days, respectively in the conventional-aerobic-SBR. The BOD(5), TKN and TP removal efficiencies of the MB-aerobic-SBR were about 1-2, 2-3 and 10-12% higher, respectively, than that of the conventional-aerobic-SBR. Also, the BOD(5) and COD removal efficiencies of the MB-aerobic-SBR were higher than 95% even when the system was operated with synthetic wastewater containing 800 mg/l BOD(5) under a very low HRT of 1.5 days (organic loading of 528+/-50.8 g BOD(5)/m(3)-d). The effluent BOD(5), COD, total kjeldahl nitrogen, total phosphorus and suspended solids of the MB-aerobic-SBR under a high organic loading of 528+/-50.8 g BOD(5)/m(3)-d were 45+/-5.1, 37+/-3.6, 4.1+/-1.0, 1.5+/-0.80 and 41+/-2mg/l, respectively.  相似文献   

16.
采用阶梯式驯化法,控制温度在18℃~24℃,pH在6—8,溶解氧在4—8mg/L,在容积为6L的驯化器中对活性污泥进行培养驯化。经过25d的培养之后,得到了稳定降解丙烯酰胺的活性污泥。驯化后的活性污泥SVI为85—132,COD去除率达70%。  相似文献   

17.
Acid pre-treated powdered waste sludge (PWS) was used for removal of textile dyestuffs from aqueous medium by adsorption as an alternative to the use of powdered activated carbon (PAC). The rate and extent of dysetuff removals were determined for four different dyestuffs at different PWS concentrations varying between 1 and 6 gl(-1). Biosorbed dyestuff concentrations at equilibrium decreased with increasing PWS concentration for all dyestuffs tested. PWS was more effective for adsorption of Remazol red RR and Chrisofonia direct yellow 12 as compared to the other dyestuffs tested. More than 80% percent dyestuff removal was obtained for all dyestuffs at PWS concentrations above 4 gl(-1) after 6h of incubation. Similar to percent dyestuff removal, the rate of adsorption was maximum at a PWS concentration of 4 gl(-1). Kinetics of adsorption of dyestuffs was investigated by using the first- and second-order kinetic models and the kinetic constants were determined. Second-order kinetics was found to fit the experimental data better than the first-order model for all dyestuffs tested. Adsorption isotherms were established for all dyestuffs used and the isotherm constants were determined by using the experimental data. Langmuir and the generalized adsorption isotherms were found to be more suitable than the Freundlich isotherm for correlation of equilibrium adsorption data. Acid pre-treated PWS was proven to be an effective adsorbent for dyestuff removal as compared to the other adsorbents reported in literature studies.  相似文献   

18.
Overland flow (OF) systems were evaluated and compared for advanced treatment of municipal and industrial effluents, including nutrients and nondegradable chemical oxygen demand (COD) removal. Three pilot plants were constructed at the Shahin Shahr Wastewater Treatment Plant (WWTP), Isfahan, Iran. Each pilot was assigned a specific wastewater and all were simultaneously operated for 8 months. Treatment of primary effluent, activated sludge secondary effluent, and lagoon effluent of textile wastewater was investigated at application rates (ARs) of 0.15, 0.25, and 0.35m(3)m(-1)h(-1). During 5 months of stable operation after a 3-month acclimation period, mean removals of total 5-day biochemical oxygen demand (TBOD(5)), total COD (TCOD), total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP) and turbidity were 74.5%, 54.8%, 66.2%, 39.4%, 35.8%, and 67.7% for primary effluent; 52.9%, 52.9%, 66.5%, 44.4%, 39.8%, and 50.1% for activated sludge effluent; 65.7%, 58.7%, 70.3%, 41.7%, 41.3%, and 54.9% for textile wastewater lagoon effluent, respectively. The model of Smith and Schroeder, 1985. Field studies of the overland flow process for the treatment of raw and primary treated municipal wastewater. Journal of Water Pollution Control Federation 57, 785-794] was satisfactory for TBOD(5). For all treatment parameters a standard first-order removal model was inadequate to represent the data but a modified first-order model provided a satisfactory fit to the data. Based on the results of this study, it can be concluded that an OF system as advanced treatment had the ability to meet effluent discharge permit limits and was an economical replacement for stabilization ponds and mechanical treatment options.  相似文献   

19.
In order to improve the process performance regarding the removal of organics, nitrogen, and an odor-causing compound (sulfide) contained in domestic wastewater, an entrapped-mixed-microbial cell (EMMC) with and without humic substances for both fixed and moving carrier reactors and conventional suspended growth culture (i.e. conventional activated sludge process) were investigated simultaneously. Both synthetic (simulated to the organics concentration of general domestic sewage) and actual domestic wastewater were investigated under operational conditions of 12 h of hydraulic retention time (HRT) with 1 h of aeration and 1 h of non-aeration, and 6 h of HRT with continuous aeration, at a room temperature of 25 +/- 2 degrees C. It was found that entrapping humic substances in the EMMC carriers had no impact on the removal of organics, nitrogen, and the odor-producing compound. Additionally, the performance of the EMMC moving carrier system for the removal of these pollutants is similar to that of the EMMC fixed carrier system. In general, the EMMC associated systems which provide high solids retention time achieve a better removal of chemical oxygen demand (COD), nitrogen, and the odor-producing substance than the suspended growth system for both HRTs of 6 h (continuous aeration) and 12 h (1 h of aeration and 1 h of non-aeration). Both the fixed and moving carrier EMMC processes, therefore, have the potential for improvement or replacement of the existing conventional activated sludge process with regard to improving the effluent qualities (such as COD, nitrogen and odor-producing compound) for reuse/disposal.  相似文献   

20.
高盐度气田废水处理试验研究   总被引:1,自引:1,他引:0       下载免费PDF全文
以某污水厂好氧污泥为接种污泥,半软性纤维填料为载体,采用逐步提高盐度和有机负荷的方法对生物膜进行耐盐性和高有机负荷驯化。结果表明:经过一段时间驯化所得异养生物膜能够适应高盐度和高有机负荷的环境;生物膜对环境盐度变化的适应性有一定的波动;生物膜对有机物的降解能力随系统有机负荷增大而降低,连续进水、出水不回流且流量为0.292L/h,HRT为24h条件下,COD去除率最后保持在65%左右;COD去除率达到65%的时间与系统有机负荷呈线性正相关,相关系数为0.9112;驯化后耐盐微生物对温度和酸碱度不敏感,最佳生长温度为23℃,pH值为7~8。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号