首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 725 毫秒
1.
Chlorophenol compounds present in many chemical industry wastewaters are resistant to biological degradation because of the toxic effects of such compounds on microorganisms. Synthetic wastewater containing different concentrations of 2,4 dichlorophenol (DCP) was subjected to biological treatment in an activated sludge unit. Effects of feed DCP concentration on COD, DCP, and toxicity removals and on sludge volume index were investigated at a constant sludge age of 10 days and hydraulic residence time (HRT) of 25 h. The Resazurin method based on dehydrogenase activity was used for assessment of toxicity for the feed and effluent wastewater. Percent COD, DCP, and toxicity removals decreased and the effluent COD, DCP, and toxicity levels increased with increasing feed DCP concentrations above 150 mgl(-1) because of inhibitory effects of DCP. Biomass concentration in the aeration tank decreased and the sludge volume index (SVI) increased with feed DCP concentrations above 150 mgl(-1) resulting in lower COD and DCP removal rates. The system should be operated at feed DCP concentrations of less than 150 mgl(-1) in order to obtain high COD, DCP, and toxicity removals.  相似文献   

2.
Due to the toxic nature of chlorophenol compounds present in some chemical industry effluents, biological treatment of such wastewaters is usually realized with low treatment efficiencies. Para-chlorophenol (4-chlorophenol, 4-CP) containing synthetic wastewater was treated in an activated sludge unit at different hydraulic residence times (HRT) varying between 5 and 30 h while the feed COD (2500 mg l(-1)), 4-CP (500 mg l(-1)) and sludge age (SRT, 10 days) were constant. Effects of HRT variations on COD, 4-CP, toxicity removals and on settling characteristics of the sludge were investigated. Percent COD removals increased and the effluent COD concentrations decreased when HRT increased from 5 to 15 h and remained almost constant for larger HRT levels. Nearly, 91% COD and 99% 4-CP removals were obtained at HRT levels above 15 h. Because of the highly concentrated microbial population at HRT levels of above 15 h, low effluent (reactor) 4-CP concentrations and almost complete toxicity removals were obtained. High biomass concentrations obtained at HRT levels above 15 h were due to low 4-CP contents in the aeration tank yielding negligible inhibition effects and low maintenance requirements. The sludge volume index (SVI) decreased with increasing HRT up to 15 h due to high biomass concentrations at high HRT levels resulting in well settling sludge with low SVI values. Hydraulic residence times above 15 h resulted in more than 90% COD and complete 4-CP and toxicity removals along with well settling sludge.  相似文献   

3.
中空纤维膜生物反应器处理炼厂浮选池出水试验研究   总被引:2,自引:0,他引:2  
研究设计的膜生物反应器处理炼厂浮选池出水,在每天进水容积负荷1.0 kg COD/m3,进水COD浓度600 mg/L,MLSS为900~5500 mg/L的条件下,无论活性污泥表现正常还是膨胀,过滤出水中COD均稳定地小于90 mg/L,处理效果好于目前炼油厂的合建式曝气池(容积负荷为0.5 kg COD/m3左右,出水COD100 mg/L左右)。试验运行期间,膜通量最高可达到42 L/m2·h。该工艺的技术关键是采用特殊流态来降低膜堵塞的膜生物反应器和优良质量的膜。  相似文献   

4.
A stratified sand filter column, operated in recirculation mode and treating synthetic effluent resembling high-strength dairy wastewaters was studied over a 342-d duration. The aim of this paper was to examine the organic, total suspended solids (TSS) and nutrient removal rates of the sand filter, operated in recirculation mode, under incrementally increasing hydraulic and organic loading rates and to propose a field filter-sizing criterion. Best performance was obtained at a system hydraulic loading rate of 10 L m(-2) d(-1); a higher system hydraulic loading rate (of 13.4 L m(-2) d(-1)) caused surface ponding. The system hydraulic loading rate of 10 L m(-2) d(-1) gave a filter chemical oxygen demand (COD), TSS, and total kjeldahl nitrogen (TKN) loading rate of 14, 3.7, and 2.1 g m(-2) d(-1), respectively, and produced consistent COD and TSS removals of greater than 99%, and an effluent NO(3)-N concentration of 42 mg L(-1) (accounting for an 86% reduction in total nitrogen (Tot-N)). As the proportional surface area requirement for the sand filter described in this study is less than the recommended surface area requirement of a free-water surface (FWS) wetland treating an effluent of similar quality, it could provide an economic and sustainable alternative to conventional wetland treatment.  相似文献   

5.
Biological treatment of landfill leachate usually results in low nutrient removals because of high chemical oxygen demand (COD), high ammonium-N content and the presence of toxic compounds such as heavy metals. Landfill leachate with high COD content was pre-treated by coagulation-flocculation with lime followed by air stripping of ammonia at pH=12. Nutrient removal from pre-treated leachate was carried out using a lab-scale sequencing batch reactor (SBR). Three different operations consisting of different numbers of steps were tested and their performances were compared. These operations were the three-step anaerobic (An)/anoxic (Ax)/oxic (Ox); the four-step (An/Ox/Ax/Ox), and the five-step (An/Ax/Ox/Ax/Ox) operations with total residence time of seven hours each. Experiments were carried out using three consecutive operations with a total cycle time of 21 h at a constant sludge age of 10 days. The lowest effluent nutrient levels were realized by using the five-step operation which resulted in effluent COD, NH4-N and PO4-P contents of 1,400, 107 and 65 mg l(-1), respectively, at the end of 21 h. Addition of domestic wastewater (1/1, v/v) and powdered activated carbon (PAC, 1 g l(-1)) to the pre-treated leachate improved nutrient removals in the five-step SBR operation, resulting in 75% COD, 44% NH4-N and 44% PO4-P removals after 21 hours of operation.  相似文献   

6.
A sequentially combined carbon (SCC) source using methanol and acetic acid was investigated for biological nitrogen and phosphorus removal in a wastewater treatment process consisting of an anoxic zone, an oxic zone and a final settling tank. The anoxic zone was divided into two separate anoxic zones to feed methanol in the first anoxic zone and acetic acid in the second anoxic zone. Methanol and acetic acid, each as the sole carbon source, were also tested for comparison. The use of SCC was superior in nitrogen removal with all combined COD ratios of methanol/acetic acid tested, yielding 95.8-97% efficiency (less than 1 mg N/l in the final effluent). The highest phosphorus removal of above 92% (final effluent concentration of 0.12 mg P/l) was achieved when only acetic acid was used at a quantity equivalent to 50 mg COD/l. However, when SCC was used, the acetic acid dosage of 50 mg COD/l could be reduced down to 20 mg COD/l when 30 mg COD/l was replaced by methanol; this resulted in a final effluent phosphorus concentration of 0.6 mg P/l. Additional benefits of SCC included the excellent sludge settling properties compared to the use of methanol or acetic acid alone.  相似文献   

7.
Pulp mill effluent was treated by different advanced oxidation processes (AOPs) consisting of UV, UV/H2O2, TiO2-assisted photo-catalysis (UV/TiO2) and UV/H2O2/TiO2 in lab-scale reactors for total organic carbon (TOC) and toxicity removals. Effects of some operating parameters such as the initial pH, oxidant and catalyst concentrations on TOC and toxicity removals were investigated. Almost every method resulted in some degree of TOC and toxicity removal from the pulp mill effluent. However, the TiO2-assisted photo-catalysis (UV/TiO2) resulted in the highest TOC and toxicity removals under alkaline conditions when compared with the other AOPs tested. Approximately, 79.6% TOC and 94% toxicity removals were obtained by the TiO2-assisted photo-catalysis (UV/TiO2) with a titanium dioxide concentration of 0.75gl(-1) at pH 11 within 60min.  相似文献   

8.
Farmstead runoff poses significant environmental impacts to ground and surface waters. Three vegetated filter strips were assessed for the treatment of dairy farmstead runoff at the soil surface and subsurface at 0.3- or 0. 46-m and 0. 76-m depths for numerous storm events. A medium-sized Michigan dairy was retrofitted with two filter strips on sandy loam soil and a third filter strip was implemented on a small Michigan dairy with sandy soil to collect and treat runoff from feed storage, manure storage, and other impervious farmstead areas. All filter strips were able to eliminate surface runoff via infiltration for all storm events over the duration of the study, eliminating pollutant contributions to surface water. Subsurface effluent was monitored to determine the contributing groundwater concentrations of numerous pollutants including chemical oxygen demand (COD), metals, and nitrates. Subsurface samples have an average reduction of COD concentrations of 20, 11, and 85% for the medium dairy Filter Strip 1 (FS1), medium dairy Filter Strip 2 (FS2), and the small Michigan dairy respectively, resulting in average subsurface concentrations of 355, 3960, and 718 mg L COD. Similar reductions were noted for ammonia and total Kjeldahl nitrogen (TKN) in the subsurface effluent. The small Michigan dairy was able to reduce the pollutant leachate concentrations of COD, TKN, and ammonia over a range of influent concentrations. Increased influent concentrations in the medium Michigan dairy filter strips resulted in an increase in COD, TKN, and ammonia concentrations in the leachate. Manganese was leached from the native soils at all filter strips as evidenced by the increase in manganese concentrations in the leachate. Nitrate concentrations were above standard drinking water limits (10 mg L), averaging subsurface concentrations of 11, 45, and 25 mg L NO-N for FS1, FS2, and the small Michigan dairy, respectively.  相似文献   

9.
对己内酰胺生产过程废水的回用处理工艺进行了研究。以某己内酰胺化工厂的LUCAS出水作为研究对象,采用膜生物反应器和反渗透膜处理工艺,研究此系统对己内酰胺废水的处理效果。试验结果表明,膜生物反应器工艺适用于该化工厂的生产废水,出水COD平均值为31.33mg/L,平均浊度为0.2NTU,氨氮平均值为2.81mg/L,可以满足反渗透膜的进水要求。在浓缩倍数为3时,反渗透膜系统运行稳定,且产水可以满足化工部循环冷却水用再生水水质标准。  相似文献   

10.
Treatment of sewage using an aged-refuse-based bioreactor   总被引:8,自引:0,他引:8  
The refuse in landfills becomes stabilized or aged after years of placement, and the resultant partly or fully stabilized refuse thus obtained is referred to as "aged refuse" in this work. The aged refuse contains a wide spectrum and large quantity of microorganisms, which have been proved to have a strong decomposition capability for both biodegradable and refractory organic matter present in some wastewaters. In this study, the aged refuse excavated from a 10-year old closed landfill compartment at Shanghai Refuse Landfill was used as the substrate in a bioreactor for the biofiltration of sewage taken from the sewage pipeline systems in Shanghai downtown areas. Typically, 120kg of screened aged refuse with a diameter less than 15mm was used as biofiltration material in a round shaped bioreactor with an inner diameter of 80cm and a height of 150cm. Influent sewage with initial COD, BOD, and NH(3)-N concentrations of 400-500, 240-300, and 45-50mg/L, respectively, was introduced into the bioreactor. The corresponding concentrations in the effluent were reduced to below 80-100, 10-20, and 10-15mg/L, respectively, at a hydraulic load of 1000-1200L/m(3) refuse/day, and the treatment efficiencies decreased with increased hydraulic load. The treatment mechanism was also studied. It was found that the pollutant removal efficiencies dramatically decreased when the aged refuse in the bioreactor was preliminarily disinfected using NaClO solutions, indicating that the pollutants in the sewage were biologically removed. The treatment process developed in this work is cost-effective.  相似文献   

11.
Biosorption of zinc (II) ions onto pre-treated powdered waste sludge (PWS) was investigated using a completely mixed tank operating in fed-batch mode instead of an adsorption column. Experiments with variable feed flow rate (0.05-0.5 L h(-1)), feed Zn(II) ion concentrations (37.5-275 mg L(-1)) and amount of adsorbent (1-6 g PWS) were performed using fed-batch operation at pH 5 and room temperature (20-25 degrees C). Break-through curves describing variations of aqueous (effluent) zinc ion concentrations with time were determined for different operating conditions. Percent zinc removal from the aqueous phase decreased, but the biosorbed (solid phase) zinc ion concentration increased with increasing feed flow rate and zinc concentration. A modified Bohart-Adams equation was used to determine the biosorption capacity of PWS (q'(s)) and the rate constant (K) for zinc ion biosorption. Biosorption capacity (q'(s)=57.7 g Zn kg(-1) PWS) of PWS in fed-batch operation was found to be comparable with powdered activated carbon (PAC) in column operations. However, the adsorption rate constant (K=9.17 m(3) kg(-1) h(-1)) in fed-batch operation was an order of magnitude larger than those obtained in adsorption columns because of elimination of mass transfer limitations encountered in the column operations. Therefore, a completely mixed tank operated in fed-batch mode was proven to be more advantageous as compared to adsorption columns due to better contact between the phases yielding faster adsorption rates.  相似文献   

12.
微生物菌剂在酿酒废水处理中的应用研究   总被引:6,自引:1,他引:5  
采用厌氧-好氧工艺,结合微生物菌剂对酿酒废水进行了处理研究。进水CODCr浓度可达到8,456.3-22,442.0mg/L,BOD55,040.0-9.557.1mg/L,pH3-4,可不调pH,采用微生物菌剂接种可启动厌氧反应器,COD有机负荷最高达到10.2gCOD/Ld,COD去除率稳定在91-95%,BOD去除率90-94%,出水pH6.6-7.1,出水CODCr在2,000mg/L以下,BOD5800mg/L以下。厌氧污泥可全部颗粒化。好氧处理系统中接种微生物菌剂,曝气10-12小时,可保证出水中CODCr在230mg/L以下,甚至直接达到国家一级排放标准。微生物菌剂的应用是取得该处理效果的关键。  相似文献   

13.
Treatment of tannery wastewater is problematic due to high and variable concentrations of complex pollutants often combined with high salinity levels. Two series of horizontal subsurface flow constructed wetlands (CWs) planted with Arundo donax and Sarcocornia fruticosa were set up after a conventional biological treatment system operating at a tannery site. The aim of the CWs was polishing organics and nitrogen from the high salinity effluent (2.2-6.6?g Cl(-)?L(-1)). Both plant species established and grew well in the CW. Arundo, however, had more vigorous growth and a higher capacity to take up nutrients. The CWs were efficient in removing COD and BOD(5) with removal efficiencies varying between 51 and 80% for COD (inlet: 68-425?mg?L(-1)) and between 53 and 90% for BOD(5) (inlet: 16-220?mg?L(-1)). Mass removal rates were up to 615?kg COD ha(-1)?d(-1) and 363 BOD(5) kg?ha(-1)?d(-1). Removal efficiencies were 40-93% for total P, 31-89% for NH(4)(+) and 41-90% for Total Kjeldahl Nitrogen. CW systems planted with salt tolerant plant species are a promising solution for polishing saline secondary effluent from the tannery industry to levels fulfilling the discharge standards.  相似文献   

14.
The occurrence of significant amounts of biocidal finishing agents in the environment as a consequence of intensive textile finishing activities has become a subject of major public health concern and scientific interest only recently. In the present study, the treatment efficiency of selected, well-known advanced oxidation processes (Fenton, Photo-Fenton, TiO(2)/UV-A, TiO(2)/UV-A/H(2)O(2)) and ozone was compared for the degradation and detoxification of a commercial textile biocide formulation containing a 2,4,4'-trichloro-2'-hydroxydiphenyl ether as the active ingredient. The aqueous biocide solution was prepared to mimic typical effluent originating from the antimicrobial finishing operation (BOD(5,o) < or =5 mg/L; COD(o)=200 mg/L; DOC(o) (dissolved organic carbon)=58 mg/L; AOX(o) (adsorbable organic halogens)=48 mg/L; LC(50,o) (lethal concentration causing 50% death or immobilization in Daphnia magna)=8% v/v). Ozonation experiments were conducted at different ozone doses (500-900 mg/h) and initial pH (7-12) to assess the effect of ozonation on degradation (COD, DOC removal), dearomatization (UV(280) and UV(254) abatement), dechlorination (AOX removal) and detoxification (changes in LC(50)). For the Fenton experiments, the effect of varying ferrous iron catalyst concentrations and UV-A light irradiation (the Photo-Fenton process) was examined. In the heterogenous photocatalytic experiments, Degussa P25-type TiO(2) was used as the catalyst and the effect of reaction pH (3, 7 and 12) and H(2)O(2) addition on the photocatalytic treatment efficiency was examined. Although in the photochemical (i.e. Photo-Fenton, TiO(2)/UV-A and TiO(2)/UV-A/H(2)O(2)) experiments appreciably higher COD and DOC removal efficiencies were obtained, ozonation appeared to be equally effective to achieve dearomatization (UV(280) abatement) at all studied reaction pH. During ozonation of the textile biocide effluent, AOX abatement proceeded significantly faster than dearomatization and was complete after 20 min ozonation (267 mg O(3)). On the other hand, for complete detoxification, ozonation had to be continued for at least 30 min (corresponding to 400mg O(3)). Effective AOX and acute toxicity removal was also obtained after heterogeneous photocatalytic treatment (TiO(2)/UV-A and TiO(2)/UV-A/H(2)O(2)). The Fenton-based treatment experiments and particularly the dark Fenton reaction resulted in relatively poor degradation, dearomatization, AOX and acute toxicity removals.  相似文献   

15.
To reduce the consumption of freshwater in the laundry industry, a new trend of closing the water cycle has resulted in the reuse/recycling of water. In this study, the performance of a full-scale submerged aerobic membrane bioreactor (9 m3) used to treat/reuse industrial laundry wastewater was examined over a period of 288 days. The turbidity and total solids (TS) were reduced by 99%, and the chemical oxygen demand (COD) effluent removal efficiencies were between 70% and 99%. The levels of COD removed by the membrane were significantly greater than the levels of biodegraded COD. This enabled the bioreactor to sustain COD levels that were below 100 mg/L, even during periods of low wastewater biodegradation due to bioreactor sludge. An economic evaluation of the membrane bioreactor (MBR) system showed a savings of 1.13 € per 1 m3 of water. The payback period for this system is approximately 6 years. The energy and maintenance costs represent only 5% of the total cost of the MBR system.  相似文献   

16.
An investigation was carried out on the performance of an anaerobic sequencing batch biofilm reactor (ASBBR) treating diluted cheese whey when submitted to different feed strategies and volumetric organic loads (VOL). Polyurethane foam cubes were used as support for biomass immobilization and stirring was provided by helix impellers. The reactor with a working volume of 3 L treated 2 L of wastewater in 8-h cycles at 500 rpm and 30 degrees C. The organic loads applied were 2, 4, 8 and 12 g COD L(-1) d(-1), obtained by increasing the feed concentration. Alkalinity was supplemented at a ratio of 50% NaHCO(3)/COD. For each organic load applied three feed strategies were tested: (a) batch operation with 8-h cycle; (b) 2-h fed-batch operation followed by 6-h batch; and (c) 4-h fed-batch followed by 4-h batch. The 2-h fed-batch operation followed by 6-h batch presented the best results for the organic loads of 2 and 4 g COD L(-1) d(-1), whereas the 4-h fed-batch operation followed by 4-h batch presented results slightly inferior for the same organic loads and the best results at organic loads of 8 and 12 g COD L(-1) d(-1). The concentration of total volatile acids varied with fill time. For the higher fill times maximum concentrations were obtained at the end of the cycle. Moreover, no significant difference was detected in the maximum concentration of total volatile acids for any of the investigated conditions. However, the maximum values of propionic acid tended to decrease with increasing fill time considering the same organic load. Microbiological analyses revealed the presence of Methanosaeta-like structures and methanogenic hydrogenotrophic-like fluorescent bacilli. No Methanosarcina-like structures were observed in the samples.  相似文献   

17.
Constructed wetlands (CW) usually require large land areas for treating wastewater. This study evaluated the feasibility of applying CW with less land requirement by operating a group of microcosm wetlands at a hydraulic retention time (HRT) of less than 4 d in southern Taiwan. An artificial wastewater, simulating municipal wastewater containing 200 mg L(-1) of chemical oxygen demand (COD), 20 mg L(-1) of NH4+-N (AN), and 20 mg L(-1) of PO4(3-)-P (OP), was the inflow source. Three emergent plants [reed, Phragmites australis (Cav.) Trin. ex Steud.; water primrose, Ludwigia octovalvis (Jacq.) P.H. Raven; and dayflower, Commelina communis L.] and two floating plants [water spinach, Ipomoea aquatica Forssk.; and water lettuce, Pistia stratiotes L.] plants were tested. The planted systems showed more nutrient removal than unplanted systems; however, the type of macrophytes in CW did not make a major difference in treatment. At the HRTs of 2 to 4 d, the planted system maintained greater than 72,80, and 46% removal for COD, AN, and OP, respectively. For AN and OP removal, the highest efficiencies occurred at the HRT of 3 d, whereas maximum removal rates for AN and OP occurred at the HRT of 2 d. Both removal rates and efficiencies were reduced drastically at the HRT of 1 d. Removals of COD, OP, and AN followed first-order reactions within the HRTs of 1 to 4 d. The efficient removals of these constituents obtained with HRT between 2 and 4 d indicated the possibility of using a CW system for wastewater treatment with less land requirement.  相似文献   

18.
Treatment of low-strength soluble wastewater (COD approximately 500 mg/L) was studied using an eight chambered anaerobic baffled reactor (ABR). At pseudo steady-state (PSS), the average total and soluble COD values (COD(T) and COD(S)) at 8h hydraulic retention time (HRT) were found to be around 50 and 40 mg/L, respectively, while at 10h HRT average COD(T) and COD(S) values were of the order of 47 and 37 mg/L, respectively. COD and BOD (3 day, 27 degrees C) removal averaged more than 90%. Effluent conformed to Indian standards laid down for BOD (less than 30 mg/L). Reactor effluent characteristics exhibited very low values of standard deviation indicating excellent reactor stability at PSS in terms of effluent characteristics. Based on mass balance calculations, more than 60% of raw wastewater COD was estimated to be recovered as CH(4) in the gas phase. Compartment-wise profiles indicated that most of the BOD and COD got reduced in the initial compartments only. Sudden drop in pH (7.8-6.7) and formation of volatile fatty acids (VFA) (53-85 mg/L) were observed in the first compartment due to acidogenesis and acetogenesis. The pH increased and VFA concentration decreased longitudinally down the reactor. Residence time distribution (RTD) studies revealed that the flow pattern in the ABR was neither completely plug-flow nor perfectly mixed. Observations from scanning electron micrographs (SEM) suggest that distinct phase separation takes place in an ABR.  相似文献   

19.
Florida dairies need year-round forage systems that prevent loss of N to ground water from waste effluent sprayfields. Our purpose was to quantify forage N removal and monitor nitrate N (NO3(-)-N) concentrations in soil water below the rooting zone for two forage systems during four 12-mo cycles (1996-2000). Soil in the sprayfield is an excessively drained Kershaw sand (thermic, uncoated Typic Quartzipsamment). Over four cycles, average loading rates of effluent N were 500, 690, and 910 kg ha(-1) per cycle. Nitrogen removed by the bermudagrass (Cynodon spp.)-rye (Secale cereale L.) system (BR) during the first three cycles was 465 kg ha(-1) per cycle for the low loading rate, 528 kg ha(-1) for the medium rate, and 585 kg ha(-1) for the high. For the corn (Zea mays L.)-forage sorghum [Sorghum bicolor (L.) Moench]-rye system (CSR), N removals were 320 kg ha(-1) per cycle for the low rate, 327 kg ha(-1) for the medium, and 378 kg ha(-1) for the high. The higher N removals for BR were attributed to higher N concentration in bermudagrass (18.1-24.2 g kg(-1)) than in corn and forage sorghum (10.3-14.7 g kg(-1)). Dry matter yield declined in the fourth cycle for bermudagrass but N removal continued to be higher for BR than CSR. The BR system was much more effective at preventing NO3(-)-N leaching. For CSR, NO3(-)-N levels in soil water (1.5 m below surface) increased steeply during the period between the harvest of one forage and canopy dosure of the next. Overall, the BR system was better than CSR at removing N from the soil and maintaining low NO3(-)-N concentrations below the rooting zone.  相似文献   

20.
The effectiveness of sewage purification by aquatic plants, such as water hyacinth (Eichhornia crassipes) and water lettuce (Pistia stratiotes), was tested on laboratory and pilot scales. Cascade and semi-continuous pilot experiments verified that the plants are capable of decreasing all tested indicators of water quality to levels that permit the use of the purified water for irrigation of tree crops. This applies to biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), and turbidity. The laboratory-scale tests confirm the capacity of the plants to reach and hold reasonably low levels of BOD (5-7 mg L(-1)) and COD (40-50 mg L(-1)) and very low levels of TSS (3-5 mg L(-1)) and turbidity (1-2 NTU). In the experimental pilot setup, with circulation, COD decreased from 460 to 100 mg L(-1) after 2.5-4 days of treatment, while 6-7 days were required to this end without circulation. This doubled the active pond area and provided a two-level hydraulic loading (8 and 12 L min(-1)) with circulation that proved to be effective during the summer as well as the winter season. The outflow concentrations were 50-85 mg L(-1) of COD and 4-6 mg L(-1) of BOD. The results show that the use of this free water surface flow system (FWS) and its low maintenance system for treatment of urban and agricultural sewage is a viable option.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号