首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
The objective of this work was to analyze the interaction effects between temperature, feed strategy and COD/[SO(4)(2-)] levels, maintaining the same ratio, on sulfate and organic matter removal efficiency from a synthetic wastewater. This work is thus a continuation of Archilha et al. (2010) who studied the effect of feed strategy at 30 °C using different COD/[SO(4)(2-)] ratios and levels. A 3.7-L anaerobic sequencing batch reactor with recirculation of the liquid phase and which contained immobilized biomass on polyurethane foam (AnSBBR) was used to treat 2.0 L synthetic wastewater in 8 h cycles. The temperatures of 15, 22.5 and 30 °C with two feed strategies were assessed: (a) batch and (b) batch followed by fed-batch. In strategy (a) the reactor was fed in 10 min with 2 L wastewater containing sulfate and carbon sources. In strategy (b) 1.2 L wastewater (containing only the sulfate source) was fed during the first 10 min of the cycle and the remaining 0.8 L (containing only the carbon source) in 240 min. Based on COD/[SO(4)(2-)] = 1 and on the organic matter (0.5 and 1.5 gCOD/L) and sulfate (0.5 and 1.5 gSO(4)(2-)/L) concentrations, the sulfate and organic matter loading rates applied were 1.5 and 4.5 g/L.d, i.e., same COD/[SO(4)(2-)] ratio (=1) but different levels (1.5/1.5 and 4.5/4.5 gCOD/gSO(4)(2-)). When reactor feed was 1.5 gCOD/L.d and 1.5 gSO(4)(2-)/L.d, gradual feeding (strategy b) showed to favor sulfate and organic matter removal in the investigated temperature range, indicating improved utilization of the electron donor for sulfate reduction. Sulfate removal efficiencies were 87.9; 86.3 and 84.4%, and organic matter removal efficiencies 95.2; 86.5 and 80.8% at operation temperatures of 30; 22.5 and 15 °C, respectively. On the other hand, when feeding was 4.5 gCOD/L.d and 4.5 gSO(4)(2-)/L.d, gradual feeding did not favor sulfate removal, indicating that gradual feeding of the electron donor did not improve sulfate reduction.  相似文献   

2.
The objective of this work was to analyze the effect of the interaction between feeding strategy and COD/sulfate ratio on the removal efficiency of sulfate and organic matter from a synthetic wastewater. An anaerobic sequencing batch reactor with recirculation of the liquid phase and containing immobilized biomass on polyurethane foam (AnSBBR) was used. The AnSBBR with a total volume of 3.7 L, treated 2.0 L synthetic wastewater in 8-h cycles at 30 ± 1 °C and was inoculated with anaerobic biomass from a UASB. Two feeding strategies were assessed: (a) batch and (b) batch followed by fed-batch. In strategy (a) the reactor was fed in 10 min with 2 L wastewater containing sulfate and carbon sources. In strategy (b) 1.2 L wastewater (containing only the sulfate source) was fed during the first 10 min of the cycle and the remaining 0.8 L (containing only the carbon source) in 240 min. The COD/sulfate ratios assessed were 1 and 3. Based on these values and on the concentrations of organic matter (0.5–11.25 gCOD/L) and sulfate (0.5 and 2.5 gSO42?/L), the sulfate and organic matter loading rates applied equaled 1.5 and 4.5 gSO42?/L d for sulfate and 1.5, 4.5 and 13.5 gCOD/L d for organic matter. After stabilization of the system time profiles were run of monitored parameters (COD, sulfate, sulfide and sulfite). In general, the reactor showed to be robust for use in the anaerobic treatment of wastewaters containing sulfate. Gradual feeding (strategy b) of the carbon source favored sulfate reduction, resulting in sulfate removal efficiencies of 84–98% and organic matter removal efficiencies of 48–95%. The best results were observed under COD/sulfate ratio equal to 1 (loading rates of 1.5 and 4.5 gSO42?/L d for sulfate, and 1.5 and 4.5 gCOD/L d for organic matter). When COD/sulfate ratio was 3 (loading rates of 1.5 and 4.5 gSO42?/L d for sulfate, and 4.5 and 13.5 gCOD/L d for organic matter) the effect of feed mode became less significant. These results show that the strategy batch followed by fed-batch is more advantageous for COD/sulfate ratios near the stoichiometric value (0.67) and higher organic matter and sulfate concentrations.  相似文献   

3.
The performance of polyurethane rotating discs (RBC-1) versus polystyrene rotating discs (RBC-2) for the treatment of an up-flow anaerobic sludge blanket (UASB) reactor effluent fed with domestic wastewater was investigated. Both RBC units were operated at the same organic loading rate (OLR) of 10.5 gCOD/m2 d. and a hydraulic retention time (HRT) of 2.5 h. The residual values of COD fractions (CODsuspended, CODcolloidal and CODsoluble) in the treated effluent of RBC-1 and RBC-2 were similar. However, the removal efficiency of ammonia in the RBC-1 (87 ± 4%) was significantly higher than that found for RBC-2 i.e. 24 ± 6%. Moreover, RBC-1 achieved a substantial removal efficiency of 99.0 ± 1% for Escherichia coli (E. coli), while RBC-2 removed 91.2 ± 0.3%. Based on these results, optimization of RBC-1 treating UASB reactor effluent was extensively performed. The RBC-1 was operated at an OLR's of 4.0, 11 and 23 gCOD/m2 d. The results obtained showed that increasing the OLR from 11.0 to 23.0 gCOD/m2 d and decreasing the HRT from 2.5 to 1.25 h significantly declined the effluent quality of CODtotal and ammonia. However, the residual values of CODtotal and ammonia remained unaffected when increasing the OLR from 4.0 to 11.0 gCOD/m2 d and by decreasing the HRT from 5 to 2.5 h. Bacteriological examination showed that the mean residual count of E. coli remained at a level of 104/100 ml, in the effluent of RBC-1 independent on the imposed HRT. Accordingly, it is recommended to operate RBC-1 for treatment of anaerobically pre-treated sewage at an OLR of 11 gCOD/m2 d and an HRT of 2.5 h.A feed-less (ammonia limitation) period of 9.0 days followed by 9.0 days feeding with high OLR of 26 gCOD/m2 d. (raw sewage) was investigated to elaborate, if the nitrifiers of the RBC-1 are capable to convert ammonia to nitrate after totally 18 days when retuning back to the normal operating conditions. The results of the experiment clearly show a strong and immediate detrimental effect of imposing high OLR of 26 gCOD/m2 d on the nitrification process in the nitrifying RBC unit. However, after returning back to the original OLR of 10.6 gCOD/m2 d, the nitrification efficiency in the RBC unit was recovered within 2–3 days.  相似文献   

4.
The objective of this work was to assess the effect of agitation rate and impeller type in two mechanically stirred sequencing batch reactors: one containing granulated biomass (denominated ASBR) and the other immobilized biomass on polyurethane foam (denominated AnSBBR). Each configuration, with total volume of 1 m3, treated 0.65 m3 sanitary wastewater at ambient temperature in 8-h cycles. Three impeller types were assessed for each reactor configuration: flat-blade turbine impeller, 45°-inclined-blade turbine impeller and helix impeller, as well as two agitation rates: 40 and 80 rpm, resulting in a combination of six experimental conditions. In addition, the ASBR was also operated at 20 rpm with a flat-blade turbine impeller and the AnSBBR was operated with a draft tube and helix impeller at 80 and 120 rpm. To quantify how impeller type and agitation rate relate to substrate consumption rate, results obtained during monitoring at the end of the cycle, as well as the time profiles during a cycle were analyzed. Increasing agitation rate from 40 rpm to 80 rpm in the AnSBBR improved substrate consumption rate whereas in the ASBR this increase destabilized the system, likely due to granule rupture caused by the higher agitation. The AnSBBR showed highest solids and substrate removal, highest kinetic constant and highest alkalinity production when using a helix impeller, 80 rpm, and no draft tube. The best condition for the ASBR was achieved with a flat-blade turbine impeller at 20 rpm. The presence of the draft tube in the AnSBBR did not show significant improvement in reactor efficiency. Furthermore, power consumption studies in these pilot scale reactors showed that power transfer required to improve mass transfer might be technically and economically feasible.  相似文献   

5.
A mechanically stirred anaerobic sequencing batch reactor (ASBR) containing granular biomass was applied to the treatment of a wastewater simulating the effluent from a personal care industry. The ASBR was operated with cycle lengths (tC) of 8, 12 and 24 h and applied volumetric organic loads (AVOL) of 0.75, 0.50 and 0.25 gCOD/L.d, treating 2.0 L liquid medium per cycle. Stirring frequency was 150 rpm and the reactor was kept in an isothermal chamber at 30 °C. Increase in tC resulted in efficiency increase at constant AVOL, reaching 77% at tC of 24 h versus 69% at tC of 8 h. However, efficiency decreased when AVOL decreased as a function of increasing tC, due to the lack of substrate in the reaction medium. Moreover, replacing part of the wastewater by a chemically balanced synthetic one did not yield the expected effect and system efficiency dropped.  相似文献   

6.
With the increase of urbanization, municipal solid waste has also increased. Therefore, the need for solid waste management is also increasing compared with earlier decades. Composting is a good option for the recycling of solid waste; however, it produces leachate, which requires proper treatment systems to prevent environmental degradation. Due to high chemical oxygen demand (COD) concentrations in compost leachate, anaerobic treatment is the best option for handling the effluent, and an anaerobic baffled reactor (ABR) is one such anaerobic reactor that can be used for its treatment. Because of high ammonia and heavy metal concentrations, as well as the possibility of sludge washout in ABRs, it is important to use proper media, such as zeolite, which can reduce inhibition effects and sludge washout from the reactor. Anaerobic treatment, especially during the methanogenesis phase, is sensitive, and pH and alkalinity are parameters that influence the treatment. Therefore, adjusting these parameters within a normal range is very important to the proper functioning of anaerobic systems. In this study, a pilot‐scale ABR was used, and the last 4 of the 8 ABR compartments were filled with zeolite. The bioreactor was operated at hydraulic retention times (HRT) of 3, 4, and 5 days, with zeolite filling ratios of 10%, 20%, and 30%, and influent COD concentrations of 10,000, 20,000, and 30,000 milligrams per liter (mg/L). In this study, pH value was 6.43 ± 0.1, 6.96 ± 0.3, and 6.96 ± 0.25 at filling ratios of 10%, 20%, and 30%, respectively. According to the results, in all filling ratios, no significant changes were observed in the pH value when the organic loading rate increased and its amount was within a constant range. Influent alkalinity was equal to 2015 ± 510, 2884 ± 505, and 4154 ± 233 milligrams of calcium carbonate per liter (mg CaCO3/L) at influent COD concentrations of 10,000, 20,000, and 30,000 mg/L, respectively, and in effluent, they were 2536 ± 336, 3379 ± 639, and 4377 ± 325 mg CaCO3/L, respectively. The amount of alkalinity in the effluent increased compared with the alkalinity in the influent. The results show that the amount of alkalinity in the influent and effluent was similar, and the alkalinity enhancement was lower when the filling ratio was increased from 10% to 20%, and 20% to 30%. Comparisons of the results from zeolite with and without biofilm showed that, in cases of zeolite with biofilm, the amounts of silica and oxygen decreased and the amount of carbon increased, and it showed the formation of biofilm on the surface of zeolite. In addition, the absence of sodium in the zeolite with the biofilm indicated that sodium was exchanged with ammonium ions. According to the results, zeolite can be used in anaerobic reactors as a medium, and it also reduces fluctuations in pH and alkalinity at different organic loading rates, providing a normal range for anaerobic treatment.  相似文献   

7.
This experimental study was conducted to evaluate a membrane sequencing batch reactor (MSBR) with mixed culture photosynthetic bacteria for dairy wastewater treatment. The study was undertaken in two steps: laboratory and pilot scale experiments. In the first step, kinetics analysis of the MSBR was carried out in a laboratory scale experiment with influent COD concentration of 2500 mg/L. The pilot scale experiment was conducted to investigate the performance of the MSBR and checked the suitability of the kinetics for an engineering design. The kinetic coefficients Ks, k, kd, Y and μm were found to be 174-mg-COD/L, 7.42/d, 0.1383/d, 0.2281/d and 1.69/d, respectively. There were some deviations of COD removal efficiency between the design value and the actual value. From the kinetics estimation, COD effluent from the design was 27 mg/L while the average actual COD effluent from the experiment was 149 mg/L. Due to the different light source condition, the factors relating to light energy (i.e. Lf and IR%) must be incorporated into engineering design and performance prediction with these kinetic coefficients of the photosynthetic MSBR.  相似文献   

8.
In Ireland, no database detailing the design, influent loading rates or performance of constructed wetlands (CWs) exists. On account of this, they are designed without any protocol based on empirical data. The aim of this paper was to provide the first published data on the performance of free-water surface flow (FWSF) CWs treating primary and secondary-treated municipal wastewater, and agricultural dairy soiled water (DSW) in Ireland. In total, the performance of thirty-four FWSF CWs, comprising fourteen CWs treating primary-treated municipal wastewater, thirteen CWs treating secondary-treated municipal wastewater, and seven CWs treating DSW, were examined. In most CWs, good organic, suspended solids (SS) and nutrient removal was measured. At an average organic loading rate (OLR) of 10 and 9 g biochemical oxygen demand (BOD) m(-2) d(-1), CWs treating primary and secondary wastewater removed 95 and 84% of influent BOD. Constructed wetlands treating DSW had an average BOD removal of 98%. At average SS loading rates of 6 and 14 g m(-2) d(-1), CWs treating primary and secondary wastewater had a 96 and an 82% reduction, and produced a final effluent with a concentration of 14 and 13 mg L(-1). Constructed wetlands treating DSW produced a final effluent of 34 mg L(-1) (94% reduction). Similar to other studies, all CWs examined had variable performance in ammonium-N (NH(4)(+)-N) removal, with average removals varying between 37% (for CWs treating secondary wastewater) and 88% (for CWs treating DSW). Variable ortho-phosphorus (PO(4)(3-)-P) removal was attributable to different durations of operation, media types and loading rates.  相似文献   

9.
An assessment was made of cheese whey treatment in a mechanically stirred anaerobic sequencing batch reactor (ASBR) containing granular biomass. The effect of increasing organic load and decreasing influent alkalinity supplementation (as sodium bicarbonate) was analyzed. The reactor operated on 8-h cycles with influent COD concentrations of 500, 1000, 2000 and 4000 mg/L, corresponding to volumetric organic loads of 0.6 to 4.8 mgCOD/L.d. Organic COD removal efficiencies were always above 90% for filtered samples. These results were obtained with an optimized alkalinity supplementation of 50% (ratio between mass of NaHCO3 added and mass of influent mgNaHCO3/mgCOD) in the assays with 500 and 1000 mgCOD/L and of 25% in the assays with 2000 and 4000 mgCOD/L. Initial alkalinity supplementation was equal to the mass of influent COD (100%). The system showed formation of viscous polymer-like substances. These were probably of microbiological origin occurring mainly at influent CODs of 2000 and 4000 mg/L and caused some biomass flotation. This could, however be controlled to enable efficient and stable reactor operation.  相似文献   

10.
This study focuses on a lab-scale rotating biological contactor (RBC) treating vegetable oil wastewater with high BOD and COD. The fabricated RBC was checked for efficiency in degrading polluted wastewater under different operating conditions. The maximum removal efficiencies for BOD and COD were 95.75% and 89%, respectively. This high removal percentage was obtained with 30% submergence of 10 discs rotating at 8 rpm. For the first time, bio-kinetic models were applied to the experimental results for vegetable oil wastewater. The best fit was obtained with the modified Stover-Kincannon and Grau model. The saturation constant (Ks) values were 1.872 and 3.024 g/L/d for BOD and COD, respectively, for the modified Stover-Kincannon and Grau model. For the Grau second-order model, the saturation constant was 1.416 and 3.744 g/L/d for BOD and COD, respectively. The predicted effluent BOD and COD values of the modified Stover–Kincannon model fitted almost exactly with the experimental values. This clearly predicts that this model can be best used to predict effluent BOD and COD concentration in a Rotating Biological contactor treating vegetable oil wastewater. The kinetic parameters determined in this study can be used to improve the design and operation of continuous mode RBC systems.  相似文献   

11.
中空纤维膜生物反应器处理炼厂浮选池出水试验研究   总被引:2,自引:0,他引:2  
研究设计的膜生物反应器处理炼厂浮选池出水,在每天进水容积负荷1.0 kg COD/m3,进水COD浓度600 mg/L,MLSS为900~5500 mg/L的条件下,无论活性污泥表现正常还是膨胀,过滤出水中COD均稳定地小于90 mg/L,处理效果好于目前炼油厂的合建式曝气池(容积负荷为0.5 kg COD/m3左右,出水COD100 mg/L左右)。试验运行期间,膜通量最高可达到42 L/m2·h。该工艺的技术关键是采用特殊流态来降低膜堵塞的膜生物反应器和优良质量的膜。  相似文献   

12.
Physico-chemical characteristics of the feed and optimum worm density are important parameters for the efficient working of a vermicomposting system. Overcrowding of worms can affect the efficiency of a vermicomposting system even if all other parameters have been optimized. This article reports the effect of stocking density and feed quality on the growth and fecundity of Eisenia fetida under laboratory conditions. The feed mixtures contained cow dung and textile mill wastewater sludge in different ratios. Three feed mixtures and five stocking rates (1, 2, 4, 8, and 12) were tested for 12 weeks. The results showed that E. fetida growth rate was faster at higher stocking densities; however, biomass gain per worm was faster at lower stocking densities. Sexual maturity was attained earlier at higher stocking densities. Growth rate was highest in 100% cow dung at all the stocking densities when compared to textile mill wastewater sludge containing feed mixtures. A worm population of 27–53 worms per kg of feed was found to be the most favorable stocking density.  相似文献   

13.
The effect of organic loading on the performance of a mechanically stirred anaerobic sequencing biofilm batch reactor (ASBBR) has been investigated, by varying influent concentration and cycle period. For microbial immobilization 1-cm polyurethane foam cubes were used. An agitation rate of 500 rpm and temperature of 30+/-2 degrees C were employed. Organic loading rates (OLR) of 1.5-6.0gCODl(-1)d(-1) were applied to the 6.3-l reactor treating 2.0 l synthetic wastewater in 8 and 12-h batches and at concentrations of 500-2000mgCODl(-1), making it possible to analyze the effect of these two operation variables for the same organic loading range. Microbial immobilization on inert support maintained approximately 60 gTVS in the reactor. Filtered sample organic COD removal efficiencies ranged from 73 to 88% for organic loading up to 5.4gCODl(-1)d(-1). For higher organic loading (influent concentration of 2000mgCODl(-1) and 8-h cycle) the system presented total volatile acids accumulation, which reduced organics removal efficiency down to 55%. In this way, ASBBR with immobilized biomass was shown to be efficient for organic removal at organic loading rates of up to 5.4gCODl(-1)d(-1) and to be more stable to organic loading variations for 12-h cycles. This reactor might be an alternative to intermittent systems as it possesses greater operational flexibility. It might also be an alternative to batch systems suspended with microorganisms since it eliminates both the uncertainties regarding granulation and the time necessary for biomass sedimentation, hence reducing the total cycle period.  相似文献   

14.
IABR-IBAF工艺处理猪场稳定塘废水的实验研究   总被引:1,自引:0,他引:1  
难降解有机物含量高且碳氮比失调是造成养猪场稳定塘废水难于处理的主要原因。本文采用基于固定化微生物技术的厌氧折流板(IABR)与曝气生物滤池(IBAF)组合工艺处理稳定塘废水,对比了IABR-IABF组合工艺与单一IBAF工艺的处理效果,研究了碱度和碳源对硝化反硝化过程的影响。组合工艺平均进水COD1532.6mg/L,平均出水为332.7mg/L,去除率为78%,NH3-N平均进水538.6mg/L,平均出水为12.3mg/L,去除率97.7%。以新鲜废水做反硝化阶段的碳源时TN去除率93%,可有效解决脱氮过程中的碳源成本问题。  相似文献   

15.
通过UASB中试装置对淀粉废水处理工艺中不同碱度对UASB反应器中的碱度和酸化的影响的研究,论述了减少碱度投加的途径和酸化的预防与系统恢复.补充碱度可以防止酸化,使反应器处于良好运行状况.通过控制运行条件可以有效降低厌氧处理中碱度需求,在最大程度上降低厌氧处理运行费用.阐述了日常监测的方法,以及预防酸化的产生的途径.  相似文献   

16.
取食品生产废水处理中试工程运行中现有的厌氧颗粒污泥进行活性抑制与恢复试验。通过慢性致毒与急性致毒作用的对比,分析酸性条件对颗粒污泥的抑制作用,研究颗粒污泥的耐酸性,并考察污泥活性恢复方法。结果表明:当进水pH=6.5,颗粒污泥活性受到轻微抑制,不影响系统的稳定运行;当pH值下降至4.5时,COD去除率和产甲烷量均趋于零。同时使用调节进水pH值、降低进水有机负荷、提高进水碱度以及调整水力停留时间等4种方法能有效恢复污泥活性,活性达到抑制前的80%左右。  相似文献   

17.
采用垂直流人工湿地模拟装置对新疆油田外排含盐稠油废水进行了处理。实验表明:对于进水CODCr为402~406mg/L,盐度5701~5712mg/L,石油类40.62mg/L的含盐稠油废水,该系统的出水指标为CODCr35~38mg/L,盐度1535~1542mg/L,湿地系统对CODCr和盐分的去除率达到91%和73%;当水力停留时间为11d以上,出水石油类<5mg/L,处理后出水CODCr、石油类达到《污水综合排放标准》(GB8978-1996)的一级标准。  相似文献   

18.
The objective of this study was to determine the best performance of an anaerobic sequencing batch biofilm reactor (AnSBBR) based on the use of four different bed materials as support for biomass immobilization. The bed materials utilized were polyurethane foam (PU), vegetal carbon (VC), synthetic pumice (SP), and recycled low-density polyethylene (PE). The AnSBBR, with a total volume of 7.2L, was operated in 8-h batch cycles over 10 months, and fed with domestic sewage with an average influent chemical oxygen demand (COD) of 358+/-110mg/L. The average effluent COD values were 121+/-31, 208+/-54, 233+/-52, and 227+/-51mg/L, for PU, VC, SP, and PE, respectively. A modified first-order kinetic model was adjusted to temporal profiles of COD during a batch cycle, and the apparent kinetic constants were 0.52+/-0.05, 0.37+/-0.05, 0.80+/-0.04, and 0.30+/-0.02h(-1) for PU, VC, SP, and PE, respectively. Specific substrate utilization rates of 1.08, 0.11, and 0.86mg COD/mgVS day were obtained for PU, VC, and PE, respectively. Although SP yielded the highest kinetic coefficient, PU was considered the best support, since SP presented loss of chemical constituents during the reactor's operational phase. In addition, findings on the microbial community were associated with the reactor's performance data. Although PE did not show a satisfactory performance, an interesting microbial diversity was found on its surface. Based on the morphology and denaturing gradient gel electrophoresis (DGGE) results, PE showed the best capacity for promoting the attachment of methanogenic organisms, and is therefore a material that merits further analysis. PU was considered the most suitable material showing the best performance in terms of efficiency of solids and COD removal.  相似文献   

19.
The water disinfecting behavior of silver-modified clinoptilolite–heulandite rich tuff (ZSAg) as an antibacterial agent against coliform microorganisms from water in a continuous mode was investigated. Silver recovery from the disinfected effluents by the sodium-modified clinoptilolite–heulandite rich tuff (ZSNa) was also considered. Escherichia coli (ATCC 8739) and total coliform microorganisms, as indicators of microbiological contamination of water, were chosen to achieve the disinfection of synthetic wastewater or municipal wastewater. Ammonium (NH4+) and chloride (Cl) ions were added to the synthetic wastewater as an interfering chemical species on the disinfection processes. The antibacterial activity of the ZSAg as a bactericide was measured by the coliform concentration as evaluated by the APHA method. The amount of silver in the disinfected effluents was determined using atomic absorption spectroscopy. The inactivation of the ZSAg was calculated from the breakthrough curves based on the model reported by Gupta et al. It was found that when the silver concentration in the effluent is less than 0.6 μg/mL, the bacterial survival percentage increased and the volume of disinfected water diminished. The total silver amounts found in the effluent at the end of the disinfection processes varied depending on the water treated (synthetic or municipal wastewater). The presence of NH4+ ions in synthetic wastewater influent notably improved the disinfected water volume (zero NVC/100 mL), in comparison to the disinfection of the same influent without NH4+ ions. A contrary water disinfection behavior was observed in the presence of Cl ions. The silver recovery does not depend on the mass of the sodium zeolitic bed according with the wastewater to be treated (synthetic or municipal wastewater) and the presence of NH4+ or Cl ions in the influent also influenced the silver recovery from wastewater. The ZSNa did not have antibacterial activity. Therefore the amount of bactericide agent (silver-modified natural zeolite), coliform microorganisms from water (E. coli or consort of coliform microorganisms) as well as the water quality (synthetic wastewater or municipal wastewater) influenced both the disinfection process and the silver recovery in a column system.  相似文献   

20.
This work presents an analysis of a stirred anaerobic sequencing discontinuous reactor with different substrate feeding strategies resulting in batch, fed-batch/batch and fed-batch operating modes. The reactor, containing granulated biomass, was fed with approximately 2.0L of synthetic domestic wastewater with Chemical Oxygen Demand of nearly 500 mg/L per cycle and operated at 30 degrees C and 50 rpm. Three feeding strategies with a total cycle time of 6 h, including 30-min settling, were adopted: batch mode with a fill cycle of 6 min, a fed-batch/batch mode with fill cycles of 60, 120 and 240 min and fed-batch mode with a fill cycle of 320 min. The system attained average non-filtered and filtered substrate removal efficiency of 78 and 84%, respectively, for all operating conditions, presenting good stability, solid retention and no granule break-up. A first order kinetic model with a residual organic matter concentration was proposed to analyze the influence of the feeding strategy on the performance during a cycle and bicarbonate alkalinity and total volatile acids concentration profiles were also quantified in order to verify the transient stability behavior.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号