首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   27篇
  免费   0篇
  国内免费   1篇
安全科学   11篇
废物处理   1篇
环保管理   2篇
综合类   3篇
基础理论   2篇
污染及防治   9篇
  2019年   1篇
  2017年   1篇
  2013年   2篇
  2012年   2篇
  2011年   2篇
  2010年   1篇
  2009年   2篇
  2008年   2篇
  2007年   6篇
  2005年   2篇
  2002年   1篇
  2001年   1篇
  2000年   1篇
  1999年   1篇
  1998年   1篇
  1996年   1篇
  1990年   1篇
排序方式: 共有28条查询结果,搜索用时 31 毫秒
1.
2.
Organic peroxides (POs) have been widely used in chemical industries as initiators of polymerization, hardening or bridge formation agents, and they are known for its self-reactive and also mixing hazard characteristics when mixed with other chemicals such as acids and alkalis. It is the purpose of this investigation to propose a simple but useful evaluation flow of mixing hazards of POs with other chemicals using conventional experimental techniques such as a glass test tube test, Dewar vessel test and DSC is proposed. 7 kinds of POs (DEPD, THP, TBEH, TBTC, MEKPO, DTBP, THHP) were mixed with sulfuric acids with various concentration, sodium hydroxide solutions, -iron(III) oxide and acrylonitrile (AN).

Based on the proposed evaluation flow the testing results were classified into 4 ranks due to the hazard criteria. Futhermore DEPD/acrylonitrile mixtures were investigated in more detail and the influences of the mixing ratio and the stirring speed were discussed.  相似文献   

3.
ABSTRACT

Easy-to-use commercial kit-based enzyme-linked immunosorbent assays (ELISAs) have been used to detect neonicotinoid dinotefuran, clothianidin and imidacloprid in Chinese chives, which are considered a troublesome matrix for chromatographic techniques. Based on their high water solubility, water was used as an extractant. Matrix interference could be avoided substantially just diluting sample extracts. Average recoveries of insecticides from spiked samples were 85–113%, with relative standard deviation of <15%. The concentrations of insecticides detected from the spiked samples with the proposed ELISA methods correlated well with those by the reference high-performance liquid chromatography (HPLC) method. The residues analyzed by the ELISA methods were consistently 1.24 times that found by the HPLC method, attributable to loss of analyte during sample clean-up for HPLC analyses. It was revealed that the ELISA methods can be applied easily to pesticide residue analysis in troublesome matrix such as Chinese chives.  相似文献   
4.
PCDDs, PCDFs, and dioxin like PCBs (dioxin) surveillance results derived from regular environmental monitoring as well as other dioxin surveys by national and local governmental bodies in Japan were collected and analyzed. Several thousand data for air and soil in fiscal year 2001 (from 01/04/2001 to 31/03/2002) and 2002, water (from the sea, rivers and lakes), sediment (from the sea, rivers and lakes), ground water, aquatic organisms, purified water from water purification plants, raw water from water purification plants, human breast milk, and human blood in fiscal 2001, and total diet study (TDS) and various kinds of foodstuff in fiscal 1998-2002 were collected. Average human uptake of dioxin in Japan in fiscal 2001 was estimated at 1.68 pg-TEQ/kg-bw/day, while uptake in fiscal 2002 was estimated at 1.52 pg-TEQ/kg-bw/day. Diet accounted for more than 90% of the total intake. Contributions of inhalation and soil ingestion were relatively small. Age-group-specific contribution of various foodstuff to total dietary intake was also estimated. The estimates of intake through fish and shellfish accounted for approximately 45-70% of total dietary intake in each age group. Monte Carlo simulation was conducted, using the data of the air and soil concentrations in fiscal 2001 and the total diet study data in fiscal 1998-2001, in order to obtain information on the variability of dioxin intake; The estimated average, median, 5th percentile and 95th percentile of the intake distribution were 1.78, 1.69, 0.95 and 2.91 pg-TEQ/kg-bw/day, respectively. This study found that the average total intake estimates in Japan in both fiscal 2001 and 2002 were estimated to be below tolerable daily intake level (TDI) defined by the Ministry of Health, Labour and Welfare, Japan (i.e. 4 pg-TEQ/kg-bw/day). The 95th percentile of the dioxin intake distributions estimated with Monte Carlo simulation using the data of the air and soil concentrations in fiscal 2001 and TDS data in fiscal 1998-2001 was also below the Japanese TDI.  相似文献   
5.
Perfluorinated compounds in the Pearl River and Yangtze River of China   总被引:27,自引:0,他引:27  
A total of 14 perfluorinated compounds (PFCs) were quantified in river water samples collected from tributaries of the Pearl River (Guangzhou Province, south China) and the Yangtze River (central China). Among the PFCs analyzed, perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) were the two compounds with the highest concentrations. PFOS concentrations ranged from 0.90 to 99 ng/l and <0.01–14 ng/l in samples from the Pearl River and Yangtze River, respectively; whereas those for PFOA ranged from 0.85 to 13 ng/l and 2.0–260 ng/l. Lower concentrations were measured for perfluorobutane sulfonate (PFBS), perfluorohexane sulfonate (PFHxS), perfluorooctanesulfoamide (PFOSA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorononaoic acid (PFNA), perfluorodecanoic acid (PFDA), and perfluoroundecanoic acid (PFUnDA). Concentrations of several perfluorocarboxylic acids, including perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluorohexadecanoic acid (PFHxDA) and perfluorooctadecanoic acid (PFOcDA) were lower than the limits of quantification in all the samples analyzed. The highest concentrations of most PFCs were observed in water samples from the Yangtze River near Shanghai, the major industrial and financial centre in China. In addition, sampling locations in the lower reaches of the Yangtze River with a reduced flow rate might serve as a final sink for contaminants from the upstream river runoffs. Generally, PFOS was the dominant PFC found in samples from the Pearl River, while PFOA was the predominant PFC in water from the Yangtze River. Specifically, a considerable amount of PFBS (22.9–26.1% of total PFC analyzed) was measured in water collected near Nanjing, which indicates the presence of potential sources of PFBS in this part of China. Completely different PFC composition profiles were observed for samples from the Pearl River and the Yangtze River. This indicates the presence of dissimilar sources in these two regions.  相似文献   
6.
Enhanced biological phosphorus removal is a well-established technology for the treatment of municipal wastewater. However, increased effluent phosphorus concentrations have been reported after periods (days) of low organic loading. The purpose of this study was to evaluate different operating strategies to prevent discharge of effluent after such low-loading periods. Mechanisms leading to these operational problems have been related to the reduction of polyphosphate-accumulating organisms (PAOs) and their storage compounds (polyhydroxy alkanoates [PHA]). Increased effluent phosphorus concentrations can be the result of an imbalance between influent loading and PAOs in the system and an imbalance between phosphorus release and uptake rates. The following operating conditions were tested in their ability to prevent a reduction of PHA and of overall biomass during low organic loading conditions: (a) unchanged operation, (b) reduced aeration time, (c) reduced sludge wastage, and (d) combination of reduced aeration time and reduced sludge wastage. Experiments were performed in a laboratory-scale anaerobic-aerobic sequencing batch reactor, using acetate as the carbon source. Without operational adjustments, phosphorus-release rates decreased during low-loading periods but recovered rapidly. Phosphorus-uptake rates also decreased, and the recovery typically required several days to increase to normal levels. The combination of reduced aeration time and reduced sludge wastage allowed the maintenance of constant levels of both PHA and overall biomass. A mathematical model was used to explain the influence of the tested operating conditions on PAO and PHA concentrations. While experimental results were in general agreement with model predictions, the kinetic expression for phosphorus uptake deviated significantly for the first 24 hours after low-loading conditions. Mechanisms leading to these deviations need to be further investigated.  相似文献   
7.
8.
Environmental Chemistry Letters - The abundance of humic-like substances in the atmosphere has received considerable attention since these substances play an important role in various atmospheric...  相似文献   
9.
The hydroxyl radical (*OH) is generated in polluted dew on the needle surfaces of Japanese red pine (Pinus densiflora Sieb. et Zucc.). This free radical, which is a potent oxidant, is assumed to be a cause of ecophysiological disorders of declining trees on the urban-facing side of Mt. Gokurakuji, western Japan. Mists of *OH-generating N(III) (HNO2 and NO2-) and HOOH + Fe + oxalate solutions (50 and 100 microM, pH 5.1-5.4) simulating the dew water were applied to the foliage of pine seedlings grown in open-top chambers in the early morning. Needles treated with 100 microM N(III) tended to have a greater maximum CO2 assimilation rate (Amax), a greater stomatal conductance (g(s)) and a greater needle nitrogen content (Nneedle), suggesting that N(III) mist acts as a fertilizer rather than as a phytotoxin. On the other hand, needles treated with 100 microM HOOH + Fe + oxalate solution showed the smallest Amax, g(s), and Nneedle, suggesting that the combination of HOOH + Fe + oxalate caused a decrease in needle productivity. The effects of HOOH + Fe + oxalate mist on pine needles were very similar to the symptoms of declining trees at Mt. Gokurakuji.  相似文献   
10.
The functional safety requirement is widely applied in the process plant industry in accordance with the international standards, such as IEC and ISA. The requirement is defined as safety integrity level (SIL) based on the risk reduction concept for protection layers, from original process risk to tolerable risk level. Although the standards specify both, the Prevention System and the Emergency System, as level of protection layers, the standards specify in detail only the use of the Prevention System (i.e., Safety Instrumented System (SIS)). The safety integrity level is not commonly allocated to the Emergency System (e.g., Fire and Gas System, Emergency Shutdown System and Emergency Depressuring System). This is because the required risk reduction can be normally achieved by only the Prevention System (i.e., SIS and Pressure Safety Valve (PSV)). Further, the risk reduction level for the Emergency System is very difficult to be quantified by the actual SIL application (i.e., evaluated based on the single accident scenario, such as an accident from process control deviation), since the escalation scenarios after Loss of Containment (LOC) greatly vary depending on the plant design and equipment. Consequently, there are no clear criteria for evaluating the Emergency System design. This paper aims to provide the functional safety requirement (i.e., required risk reduction level based on IEC 61508 and 61511) as design criteria for the Emergency System.In order to provide clear criteria for the Emergency System evaluation, a risk reduction concept integrated with public’s perception of acceptable risk criteria is proposed and is applied to identify the required safety integrity level for the Emergency System design. Further, to verify the safety integrity levels for the Emergency Systems, the probabilistic model of the Emergency Systems was established considering each Emergency System (e.g., Fire and Gas System, Emergency Shutdown System and Emergency Depressuring System) relation as the Overall Emergency System. This is because the Overall Emergency System can achieve its goal by the combined action of each individual system, including inherent safe design, such as separation distance.The proposed approach applicability was verified by conducting a case study using actual onshore Liquefied Natural Gas Plant data. Further, the design criteria for Emergency Systems for LNG plants are also evaluated by sensitivity analysis.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号