首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
废物处理   1篇
环保管理   1篇
综合类   1篇
污染及防治   6篇
  2022年   1篇
  2021年   1篇
  2020年   3篇
  2018年   1篇
  2017年   1篇
  2013年   1篇
  2012年   1篇
排序方式: 共有9条查询结果,搜索用时 153 毫秒
1
1.
This study proposed to detect the enterovirus (EV) infection in children with type 1 diabetes mellitus (T1D) and to assess the role of insufficiently treated water and sewage as sources of viral spreading. Three hundred and eighty-two serum specimens of children with T1D, one hundred serum specimens of children who did not suffer from T1D as control, and forty-eight water and sewage samples were screened for EV RNA using nested RT-PCR. The number of genome copies and infectious units of EVs in raw and treated sewage and water samples were investigated using real-time (RT)-PCR and plaque assay, respectively. T1D markers [Fasting blood glucose (FBG), HbA1c, and C-peptide], in addition to anti-Coxsackie A & B viruses (CVs A & B) IgG, were measured in control, T1D-negative EV (T1D–EV?), and T1D-positive EV (T1D–EV+) children specimens. The prevalence of EV genome was significantly higher in diabetic children (26.2%, 100 out of 382) than the control children (0%, 0 out of 100). FBG and HbA1c in T1D–EV? and T1D–EV+ children specimens were significantly higher than those in the control group, while c-peptide in T1D–EV? and T1D–EV+ children specimens was significantly lower than that in the control (n = 100; p < 0.001). Positivity of anti-CVs A & B IgG was 70.7, 6.7, and 22.9% in T1D–EV+, T1D–EV?, and control children specimens, respectively. The prevalence of EV genome in drinking water and treated sewage samples was 25 and 33.3%, respectively. The prevalence of EV infectious units in drinking water and treated sewage samples was 8.5 and 25%, respectively. Quantification assays were performed to assess the capabilities of both wastewater treatment plants (WWTPs) and water treatment plants (WTPs) to remove EV. The reduction of EV genome in Zenin WWTP ranged from 2 to 4 log10, while the reduction of EV infectious units ranged from 1 to 4 log10. The reduction of EV genome in El-Giza WTP ranged from 1 to 3 log10, while the reduction of EV infectious units ranged from 1 to 2 log10. This capability of reduction did not prevent the appearance of infectious EV in treated sewage and drinking water. Plaque purification was performed for isolation of separate EV isolates from treated and untreated water and sewage samples. Characterization of the EV amplicons by RT-PCR followed by sequencing of these isolates revealed high homology (97%) with human coxsackievirus B4 (CV B4) in 60% of the isolates, while the rest of the isolates belonged to poliovirus type 1 and type 2 vaccine strains. On the other hand, characterization of the EV amplicons by RT-PCR followed by sequencing for T1D–EV+ children specimens indicated that all samples contained CV B4 with the same sequence characterized in the environmental samples. CV B4-contaminated drinking water or treated sewage may play a role as a causative agent of T1D in children.  相似文献   
2.
Journal of Material Cycles and Waste Management - In this study, a mechanochemical activation technique to effectually extract lead from the funnel glass of cathode ray tube (CRT) is proposed. A...  相似文献   
3.
Environmental Science and Pollution Research - Nanoparticle (NP) pollution is a worldwide problem. Copper oxide nanoparticles (CuO NPs) are one of the most used NPs in a variety of applications,...  相似文献   
4.
The solar chimney power plant (SCPP) is a power generator which uses solar radiation to increase the internal energy of the air circulating in the system, thereby transforming the useful gain of the solar collector into kinetic energy. The produced kinetic energy then can be converted into electrical energy by means of an appropriate turbine. In this paper, four locations in Algeria

(Constantine, Ouargla, Adrar, and Tamanrasset) were considered as case studies to describe the SCPP mechanism in detail. Numerical simulation of an SCPP which has the same geometrical dimensions was performed to estimate the power output of SCPP in these regions. Using the CFD software FLUENT we simulated a two-dimensional axisymmetric model of a SCPP with the standard k-ε turbulence model. The simulation results show that the highest power output produced monthly average value 68–73 KW over the year and the highest hourly power produced in June is around 109–113 KW.  相似文献   

5.
Environmental Science and Pollution Research - New approaches are required for prevention and control of biofilm-producing bacteria and consequently mitigating the health problems of bovine...  相似文献   
6.

DNA damage may develop at any dose of ionizing radiation. DNA damage activates pathways that regulate cell growth and division or coordinate its replication and repair. The repair pathways, base excision repair (BER) and single-strand break repair (SSBR), can repair such damages efficiently and maintain genome integrity. Loss of this repair process or alteration of its control will be associated with serious outcomes for cells and individuals. This study aimed to determine the relationship between XRCC1 (Arg194Trp, Arg280His, and Arg399Gln), OGG1 (Ser326Cys), and XRCC3 (Thr241Met) SNPs and DNA damage and to identify high-risk individuals with reduced DNA repair capacity. This case-control study was conducted on 80 subjects; 50 subjects working in Clinical Oncology and Nuclear Medicine Department in Assiut University Hospital along with 30 controls. A total of 1 mL blood samples were collected for Single-Cell Gel Electrophoresis Technique (Comet Assay) for detection of DNA damage in those subjects. A total of 3 mL fresh blood samples were collected and analyzed by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP)–based technique. DNA damage detected by comet test was significantly high in IR-exposed workers than control. Statistically high significant difference was found in exposed subjects versus control subjects regarding the frequencies of the variant alleles of hOGG1326, XRCC1280 & 399, and XRCC3241. The level of DNA damage was not affected by OGG1326 SNPs when comparing subjects of wild genotype with those of (pooled) variants either in the exposed staff or in the control group while XRCC1280, 399 and XRCC3241 variant alleles had an influence on the studied DNA damage biomarker. Moreover, genotyping distribution pattern was highly variable in relation to gender. The present study indicated a relationship between DNA damage detected by comet test and single nucleotide polymorphisms in genes coding for DNA certain repair enzymes. Individuals occupationally exposed to low doses of ionizing radiation could be at great risk and more susceptible to the increased DNA damage if they have inherited genetic polymorphism.

  相似文献   
7.
Biofilms harboring simultaneously anoxygenic and oxygenic phototrophic bacteria, diazotrophic bacteria, and hydrocarbon-utilizing bacteria were established on glass slides suspended in pristine and oily seawater. Via denaturing gradient gel electrophoresis analysis on PCR-amplified rRNA gene sequence fragments from the extracted DNA from biofilms, followed by band amplification, biofilm composition was determined. The biofilms contained anoxygenic phototrophs belonging to alphaproteobacteria; pico- and filamentous cyanobacteria (oxygenic phototrophs); two species of the diazotroph Azospirillum; and two hydrocarbon-utilizing gammaproteobacterial genera, Cycloclasticus and Oleibacter. The coexistence of all these microbial taxa with different physiologies in the biofilm makes the whole community nutritionally self-sufficient and adequately aerated, a condition quite suitable for the microbial biodegradation of aquatic pollutant hydrocarbons.  相似文献   
8.
Aquatic and terrestrial associations of phototrophic and heterotrophic microorganisms active in hydrocarbon bioremediation have been described earlier. The question arises: do similar consortia also occur in the atmosphere? Dust samples at the height of 15?m were collected from Kuwait City air, and analyzed microbiologically for phototrophic and heterotrophic hydrocarbon-utilizing microorganisms, which were subsequently characterized according to their 16S rRNA gene sequences. The hydrocarbon utilization potential of the heterotrophs alone, and in association with the phototrophic partners, was measured quantitatively. The chlorophyte Gloeotila sp. and the two cyanobacteria Nostoc commune and Leptolyngbya thermalis were found associated with dust, and (for comparison) the cynobacteria Leptolyngbya sp. and Acaryochloris sp. were isolated from coastal water. All phototrophic cultures harbored oil vapor-utilizing bacteria in the magnitude of 105?g?1. Each phototrophic culture had its unique oil-utilizing bacteria; however, the bacterial composition in Leptolyngbya cultures from air and water was similar. The hydrocarbon-utilizing bacteria were affiliated with Acinetobacter sp., Aeromonas caviae, Alcanivorax jadensis, Bacillus asahii, Bacillus pumilus, Marinobacter aquaeolei, Paenibacillus sp., and Stenotrophomonas maltophilia. The nonaxenic cultures, when used as inocula in batch cultures, attenuated crude oil in light and dark, and in the presence of antibiotics and absence of nitrogenous compounds. Aqueous and diethyl ether extracts from the phototrophic cultures enhanced the growth of the pertinent oil-utilizing bacteria in batch cultures, with oil vapor as a sole carbon source. It was concluded that the airborne microbial associations may be effective in bioremediating atmospheric hydrocarbon pollutants in situ. Like the aquatic and terrestrial habitats, the atmosphere contains dust-borne associations of phototrophic and heterotrophic hydrocarbon-utilizing bacteria that are active in hydrocarbon attenuation.  相似文献   
9.
Environmental Science and Pollution Research - This study was conducted to elucidate the ameliorative potential of lycopene (LYC) against the metabolic toxicity induced by bisphenol A (BPA) in...  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号