首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   10篇
  免费   0篇
废物处理   2篇
基础理论   2篇
污染及防治   3篇
评价与监测   2篇
社会与环境   1篇
  2021年   1篇
  2019年   1篇
  2018年   1篇
  2016年   2篇
  2014年   2篇
  2013年   2篇
  2011年   1篇
排序方式: 共有10条查询结果,搜索用时 15 毫秒
1
1.
We show with the results of a study conducted in the Hamadan Province, Iran as to how the use of composite sampling for estimating mean zinc concentration in the soil can help reduce analytical costs by reducing the number of analysis required. We also introduce post-stratification methodology in the composition step to take advantage of possible spatial dispersion. We speculate that the zinc concentration value depends on the sample location, we first stratified the sample set and then composite units from different strata randomly. The results of a simulation study show that the use of this approach not only reduces the total costs but also increases the precision of the estimator.  相似文献   
2.
Journal of Material Cycles and Waste Management - Once a tire is removed from a vehicle without the possibility of being remounted for continued on-road use, it is defined as waste and called...  相似文献   
3.
4.
One of the most attractive features of hydrogen as an energy carrier is that it can be produced from water. Hydrogen has the highest energy content per unit mass as compared to chemical fuel and can be substituted. Its burning process is non-polluting, and it can be used in the fuel cells to produce both electricity and useful heat. Photovoltaic arrays can be used in supplying the water electrolysis systems by their energy requirements. During the daylight hours, the sunlight on the photovoltaic array converts into electrical energy which can be used for electrolyzer. The hydrogen produced by the electrolyzer is compressed and stored in hydrogen vessel and provides energy for the fuel cell to meet the load when the solar energy is insufficient. This study investigates a stand-alone power system that consists of PV array as power supply and electrolyzer. They have been integrated and worked at the Taleghan renewable energies’ site in Iran. The National Renewable Energy Laboratory’s Hybrid Optimization Model for Electric Renewables simulation software has been used to carry out the optimal design and techno-economic viability of the energy system. The simulation results demonstrate that energy system is composed of 10-kW PV array, 3.5-kW electrolyzer, 0.4-kW proton exchange membrane fuel cell, 2.5-kW inverter, and 60 batteries (100 Ah and 12 V). The total initial capital cost, net present cost, and cost of electricity produced from this energy system are 193,563 US$, 237,509 US$, and 3.35 US$/kWh, respectively.  相似文献   
5.

The novel SARS-CoV-2 outbreak was declared as pandemic by the World Health Organization (WHO) on March 11, 2020. Understanding the airborne route of SARS-CoV-2 transmission is essential for infection prevention and control. In this study, a total of 107 indoor air samples (45 SARS-CoV-2, 62 bacteria, and fungi) were collected from different wards of the Hajar Hospital in Shahrekord, Iran. Simultaneously, bacterial and fungal samples were also collected from the ambient air of hospital yard. Overall, 6 positive air samples were detected in the infectious 1 and infectious 2 wards, intensive care unit (ICU), computed tomography (CT) scan, respiratory patients’ clinic, and personal protective equipment (PPE) room. Also, airborne bacteria and fungi were simultaneously detected in the various wards of the hospital with concentrations ranging from 14 to 106 CFU m?3 and 18 to 141 CFU m?3, respectively. The highest mean concentrations of bacteria and fungi were observed in respiratory patients’ clinics and ICU wards, respectively. Significant correlation (p < 0.05) was found between airborne bacterial concentration and the presence of SARS-CoV-2, while no significant correlation was found between fungi concentration and the virus presence. This study provided an additional evidence about the presence of SARS-CoV-2 in the indoor air of a hospital that admitted COVID-19 patients. Moreover, it was revealed that the monitoring of microbial quality of indoor air in such hospitals is very important, especially during the COVID-19 pandemic, for controlling the nosocomial infections.

  相似文献   
6.
From environmental viewpoint, the most important advantage of compact fluorescent lamps (CFLs) is reduction of green house gas emissions. But their significant disadvantage is disposal of spent lamps because of containing a few milligrams of toxic metals, especially mercury and lead. For a successful implementation of any waste management plan, availability of sufficient and accurate information on quantities and compositions of the generated waste and current management conditions is a fundamental prerequisite. In this study, CFLs were selected among 20 different brands in Iran. Content of heavy metals including mercury, lead, nickel, arsenic and chromium was determined by inductive coupled plasma (ICP). Two cities, Tehran and Tabriz, were selected for assessing the current waste management condition of CFLs. The study found that waste generation amount of CFLs in the country was about 159.80, 183.82 and 153.75 million per year in 2010, 2011 and 2012, respectively. Waste generation rate of CFLs in Iran was determined to be 2.05 per person in 2012. The average amount of mercury, lead, nickel, arsenic and chromium was 0.417, 2.33, 0.064, 0.056 and 0.012 mg per lamp, respectively. Currently, waste of CFLs is disposed by municipal waste stream in waste landfills. For improving the current conditions, we propose by considering the successful experience of extended producer responsibility (EPR) in other electronic waste management. The EPR program with advanced recycling fee (ARF) is implemented for collecting and then recycling CFLs. For encouraging consumers to take the spent CFLs back at the end of the products’ useful life, a proportion of ARF (for example, 50%) can be refunded. On the other hand, the government and Environmental Protection Agency should support and encourage recycling companies of CFLs both technically and financially in the first place.  相似文献   
7.
Fluoride intake, fluorosis, and dental caries could affect quality of life and disease burden worldwide. As a part of the National and Sub-national Burden of Disease Study (NASBOD) in Iran, we conducted a systematic review to evaluate province-year-specific mean drinking water fluoride concentrations and prevalence of fluorosis and of decayed, missed, and filled teeth (DMFT) in Iran from 1990 to December 2015. We did electronic searches of all English and Persian publications on PubMed, ScienceDirect, Google Scholar, and Iranian databases. Results revealed that the weighted mean drinking water fluoride concentration in Iran from 1990 to 2015 has been about 0.65?±?0.38 mg/l. However, based on the WHO guideline value (1.50 mg/l) and the maximum permissible Iranian national fluoride standard (1.40 to 2.40 mg/l depending on the region's climate), there have been some regions in Iran with non-optimum fluoride concentrations in their drinking water (up to 7.0 mg/l). Overall, concentrations have been higher in southern parts of Iran and in some areas of Azerbaijan-e-Gharbi Province in the northwest and lower in the rest of the northwest and central parts of Iran. In addition, some hotspots have been found in Bushehr Province, southwest of Iran. The highest prevalence of dental flourosis has been reported in normal index while the lowest prevalence has been expressed in severe index. The lowest DMFT (about 0.1) was in Arsanjan City in Fars Province, and the highest (about 6.7) was for Najaf Abad City in Isfahan Province. Prevalence of fluorosis has been rather high in studied areas of Iran (e.g. 100 % in Maku City in Azarbaijan-e-Gharbi Province), and there was discrepancy for DMFT, but a lack of studies renders the results inconclusive. Further studies, health education and promotion plans, and evidence-based nutrition programs are recommended.  相似文献   
8.
Understanding the spatiotemporal relationships between land use/cover changes (LUCC) and groundwater resources is necessary for effective and efficient land use management. In this paper, geographically weighted regression (GWR) and ordinary least squares (OLS) models have been expanded to analyze varying spatial relationships between groundwater quantity changes and LUCC for three periods: 1987–2000, 2000–2010, and 1987–2010 in the Khanmirza Plain of southwestern Iran. For this purpose, TM images were used to generate LUCC (rainfed, irrigated, meadow, and bare lands). Groundwater quantity variables, including groundwater level changes (GLC) and groundwater withdrawal differences (GWD), were gathered from piezometric and agricultural wells data. The analysis of spatial autocorrelation (Moran’s I and local indicators of spatial association ) demonstrated that GWR has a better ability to model spatially varying data with very minimal clustering of residuals. The results R 2 and corrected Akaike’s Information Criterion parameters revealed that the GWR has the lowest similarity in space and time in neighboring situations and it has the high ability to explain more variance in the LUCC as a function of the groundwater quantity changes. All results of the distribution of local R 2 values from GWR confirm our assertion that there is a spatiotemporal relationship between types of land use and each of groundwater quantity variables within the region. According to the t test results from GWR, there are significant differences between the GLC and GWD and the land use types in different places of region in each of the three time series. The GWR results can help decision-makers to make appropriate decisions for future planning.  相似文献   
9.
Organic acid has been related to nutrient mobilization, mainly in phosphorus (P) insoluble utilization, and therefore enhances P bioavailability. In this study, we examined the effect of low-molecular-weight organic acids (malic, citric, and oxalic acids) on P release of some calcareous soils from western Iran. Fractionation and speciation of P in the soil solution were studied at the initial and final P release. Significantly different quantities of P were extracted by the organic acids. On average the maximum (1,554.9 mg kg-1) and the minimum (1,260.5 mg kg-1) P were extracted by 10 mM oxalic and malic acid, respectively. Power equation described well P release. In the initial stage of P release, the solution samples in soils were supersaturated with respect to hydroxyapatite and β-TCP. At the end of P release, all solutions were undersaturated with phosphate minerals. The percentage of Fe-Al oxide fraction generally increased after P release, while carbonate and residual P fractions were decreased in all organic acids. Compared with the native soils, adding malic and citric acids had no effect on Fe-Al oxide fraction, but oxalic acid significantly reduced this fraction.  相似文献   
10.

The aim of this study was to investigate and determine fluoride concentrations in drinking water supplies in rural areas of Maku and Poldasht in West Azerbaijan Province, the northwest of Iran. Fluorosis risk assessment and characterization was also investigated. Fluoride concentrations mapping was accomplished by using the GIS system. Totally, 356 water samples, including one sample in each season, were collected from 89 water supplies providing water for 95 and 61 rural areas of Maku and Poldasht, respectively. According to the results, in Maku and Poldasht, 25 and 30 rural areas had contaminated water sources, respectively. Average annual fluoride concentrations ranged from 3.04 to 7.31 mg/l in the contaminated villages of Maku, which is about 2–4.8 times higher than the maximum standard level of the Iranian drinking water standard, and 4.52–8.21 mg/l in the contaminated areas of Poldasht, which is about 3–5.47 times higher than the maximum standard level. The maximum fluoride level was determined 11.12 mg/l and 10.98 mg/l in one of villages of Maku and Poldasht Counties in summer, respectively. Neither in Maku nor in Poldasht, water resources showed dental cavity risk, while dental fluorosis risk and skeletal fluorosis risk were very significant in some villages of both cities. Children were at most risk of fluorosis. New alternative water supplies for the contaminated villages if possible, consumption of bottled water and application of reverse osmosis are recommended as remedial actions in the contaminated areas.

  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号