首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   173篇
  免费   4篇
  国内免费   12篇
安全科学   11篇
废物处理   12篇
环保管理   17篇
综合类   26篇
基础理论   29篇
环境理论   1篇
污染及防治   77篇
评价与监测   9篇
社会与环境   4篇
灾害及防治   3篇
  2023年   1篇
  2022年   2篇
  2019年   1篇
  2018年   7篇
  2017年   12篇
  2016年   7篇
  2015年   7篇
  2014年   8篇
  2013年   19篇
  2012年   12篇
  2011年   13篇
  2010年   12篇
  2009年   9篇
  2008年   18篇
  2007年   16篇
  2006年   10篇
  2005年   10篇
  2004年   10篇
  2003年   6篇
  2002年   3篇
  2001年   1篇
  1994年   1篇
  1991年   1篇
  1978年   1篇
  1970年   1篇
  1969年   1篇
排序方式: 共有189条查询结果,搜索用时 609 毫秒
1.
Daily fine particulate matter (PM2.5) samples were collected at Gwangju, Korea, during the Aerosol Characterization Experiments (ACE)-Asia Project to determine the chemical properties of PM2.5 originating from local pollution and Asian dust (AD) storms. During the study period, two significant events occurred on April 10-13 and 24-25, 2001, and a minor event occurred on April 19, 2001. Based on air mass transport pathways identified by back-trajectory calculation, the PM2.5 dataset was classified into three types of aerosol populations: local pollution and two AD aerosol types. The two AD types were transported along different pathways. One originated from Gobi desert area in Mongolia, passing through Hunshandake desert in Northern Inner Mongolia, urban and polluted regions of China (AD1), and the other originated in sandy deserts located in the Northeast Inner Mongolia Plateau and then flowed southward through the Korean peninsula (AD2). During the AD2 event, a smoke plume that originated in North Korea was transported to our study site. Mass balance closures show that crustal materials were the most significant species during both AD events, contributing -48% to the PM2.5 mass; sulfate aerosols (19.1%) and organic matter (OM; 24.6%) were the second greatest contributors during the AD1 and AD2 periods, respectively, indicating that aerosol properties were dependent on the transport pathway. The sulfate concentration constituted only 6.4% (4.5 microg/m3) of the AD2 PM2.5 mass. OM was the major chemical species in the local pollution-dominated PM2.5 aerosols, accounting for 28.7% of the measured PM2.5 mass, followed by sulfate (21.4%), nitrate (15%), ammonium (12.8%), elemental carbon (8.9%), and crustal material (6.5%). Together with substantial enhancement of the crustal elements (Mg, Al, K, Ca, Sc, Ti, Mn, Fe, Sr, Zr, Ba, and Ce), higher concentrations of pollution elements (S, V, Ni, Zn, As, Cd, and Pb) were observed during AD1 and AD2 than during the local pollution period, indicating that, in addition to crustal material, the AD dust storms also had a significant influence on anthropogenic elements.  相似文献   
2.
Recently, nano zero-valent iron (nZVI) has emerged as an effective adsorbent for the removal of arsenic from aqueous solutions. However, its use in various applications has suffered from reactivity loss resulting in a decreased efficiency. Thus, the aim of this study was to develop an effective arsenic adsorbent as a core/shell structural nZVI/manganese oxide (or nZVI/Mn oxide) to minimize the reactivity loss of the nZVI. As the major result, the arsenic adsorption capacities of the nZVI/Mn oxide for As(V) and As(III) were approximately two and three times higher than that of the nZVI, respectively. In addition, the As(V) removal efficiency of the nZVI/Mn oxide was maintained through 4 cycles of regeneration whereas that of the nZVI was decreased significantly. The enhanced reactivity and reusability of the nZVI/Mn oxide can be successfully explained by the synergistic interaction of the nZVI core and manganese oxide shell, in which the manganese oxides participate in oxidation reactions with corroded Fe2+ and subsequently retard the release of aqueous iron providing additional surface sites for arsenic adsorption. In summary, this study reports the successful fabrication of a core/shell nZVI/Mn oxide as an effective adsorbent for the removal of arsenic from aqueous solutions.  相似文献   
3.
Generally, one expects evapotranspiration (ET) maps derived from optical/thermal Landsat and MODIS satellite imagery to improve decision support tools and lead to superior decisions regarding water resources management. However, there is lack of supportive evidence to accept or reject this expectation. We “benchmark” three existing hydrologic decision support tools with the following benchmarks: annual ET for the ET Toolbox developed by the United States Bureau of Reclamation, predicted rainfall‐runoff hydrographs for the Gridded Surface/Subsurface Hydrologic Analysis model developed by the U.S. Army Corps of Engineers, and the average annual groundwater recharge for the Distributed Parameter Watershed Model used by Daniel B. Stephens & Associates. The conclusion of this benchmark study is that the use of NASA/USGS optical/thermal satellite imagery can considerably improve hydrologic decision support tools compared to their traditional implementations. The benefits of improved decision making, resulting from more accurate results of hydrologic support systems using optical/thermal satellite imagery, should substantially exceed the costs for acquiring such imagery and implementing the remote sensing algorithms. In fact, the value of reduced error in estimating average annual groundwater recharge in the San Gabriel Mountains, California alone, in terms of value of water, may be as large as $1 billion, more than sufficient to pay for one new Landsat satellite.  相似文献   
4.
This study investigated the effect of adding vanadium (V) to natural manganese oxide (NMO) in ammonia (NH3) selective catalytic reduction (SCR). The addition of V to NMO decreased the catalytic activity at low temperatures by blocking the active site. However, the enhancement of catalytic activity was achieved by controlling NH3 oxidation at high temperatures. From the NH3 temperature programmed desorption and oxygen on/off test, it was confirmed that the amount of Lewis acid site and active lattice oxygen of the catalyst affects the catalytic performance at low temperature.  相似文献   
5.
A bias in clear-sky conditions that will be involved in estimating particulate matter(PM)concentration from aerosol optical depth(AOD) was examined using PM_(10) from two Aerosol Robotic Network sites in Korea. The study periods were between 2004 and 2007 at Anmyon and between 2003 and 2011 at Gosan, when both PM_(10) and AOD were available. Mean PM_(10) when AOD was available(PM AOD) was higher than that from all PM_(10)data(PM all) by 5.1 and9.9 μg/m~3 at Anmyon and Gosan, which accounted for 11% and 26% of PM all, respectively.Because of a difference between mean PM_(10) under daytime clear-sky conditions(PM clear)and PM AOD, the variations in ΔPM_(10), the difference of PM all from PM clear rather than from PM AOD, were investigated. Although monthly variations in ΔPM_(10)at the two sites were different, they were positively correlated to those in ΔT, similarly defined as ΔPM_(10)except for temperature, at both sites. ΔPM_(10)at Anmyon decreased to a negative value in January due to an influence of the Siberian continental high-pressure system while ΔPM_(10)at Gosan was high in winter due to an effect of photochemical production at higher temperatures than at Anmyon.  相似文献   
6.
This article develops a direct methanol fuel cell (DMFC) with a magnet-actuated bubble removal mechanism. A micro-DC motor is used to control the bubble removal mechanism. The lower magnetic device is operated to extrude a Polydimethylsiloxane (PDMS) runner to compress the liquid fuel in the anode flow channel, forcing the CO2 bubbles in the runner to flow toward the outlet end. The bubble retention in the anode flow channel is thereby improved, enhancing the cell performance. The proposed mechanism stability and performance and Polymethylmethacrylate (PMMA) runner are also discussed.  相似文献   
7.
Six monitoring stations were selected to characterize the variations in airborne concentrations of heavy metals in South Korea between 1999 and 2012. Three stations represented higher concentrations, and three represented lower concentrations. The heavy metals monitored at these stations include cadmium, chromium, copper, iron (Fe), lead, manganese (Mn), and nickel. During the study period, concentrations of heavy metals at many stations, including those around the Seoul metropolitan area, showed a decreasing trend. However, concentrations of Mn and Fe that are primarily of crustal origin increased at four of the six stations. Some stations were significantly affected by emissions from the local industrial complex (IC), and heavy metal concentrations at those stations were relatively high even in summer. Many heavy metal concentrations were higher in spring than in winter, but wintertime concentrations of Cr and Pb were higher at the stations representing lower concentrations due to the dominant influence of combustion emissions. At stations less affected by emissions from the IC, concentrations of Fe and Mn that are predominantly crustal in origin were higher in spring, when Asian dust (AD) events are most frequent. Although Mn concentrations were also high at stations within the steelmaking IC during AD periods, they were much higher during non-AD periods due to local emissions. Variations in heavy metal concentrations, which are heavily influenced by emissions from the IC, warrant individual analysis because their emission characteristics differ from those of typical cases.  相似文献   
8.
Abstract

Combustion of spent vacuum residue hydrodesulfurization catalyst and incineration of paper sludge were carried out in thermo-gravimetric analyzer and an internally circulating fluidized-bed (ICFB) reactor. From the thermogravimetric analyzer-differential thermo-gravimetric curves, the pre-exponential factors and activation energies are determined at the divided temperature regions, and the thermo-gravimetric analysis patterns can be predicted by the kinetic equations. The effects of bed temperature, gas velocity in the draft tube and annulus, solid circulation rate, and waste feed rate on combustion efficiency of the wastes have been determined in an ICFB from the experiments and the model studies. The ICFB combustor exhibits uniform temperature distribution along the bed height with high combustion efficiency (>90%). The combustion efficiency increases with increasing reaction temperature, gas velocity in the annulus region, and solid circulation rate and decreases with increasing waste feed rate and gas velocity in the draft tube. The simulated data from the kinetic equation and the hydrodynamic models predict the experimental data reasonably well.  相似文献   
9.
We characterize the monthly variation in (1 → 3)-β-d-glucan concentration measured over the course of 1 year, and we evaluate the characteristics of size selection using a two-stage cyclone sampler. The (1 → 3)-β-d-glucan concentrations were measured in four bio-related laboratories. A total of 156 samples were collected using a new two-stage cyclone sampler. Analysis of (1 → 3)-β-d-glucan was performed using the kinetic Limulus amebocyte lysate assay. The study showed that airborne (1 → 3)-β-d-glucan concentrations were significantly higher in laboratory D (mean ± SD 1,105?±?1,893 pg/m3) and in the spring (5,458 pg/m3). The highest concentration of (1 → 3)-β-d-glucan occurred in the spring, particularly in May.  相似文献   
10.
Indoor air quality has become a critical issue because people spend most of their time in the indoor environment. The factors that influence indoor air quality are very important to environmental sanitation and air quality improvement. This study focuses on monitoring air quality, colony counts, and bacteria species of the indoor air of a nursing care institution. The regular colony counts in two different wards range from 55 to 600 cfu m(-3) Regression analysis results indicate that the bacterial colony counts have close correlation with relative humidity or carbon dioxide (CO2) but not with carbon monoxide (CO) or ozone (O3). Real-time PCR was used to quantify the bacterial pathogens of nosocomial infection, including Acinetobacter baumannii, Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, and methicillin-sensitive Staphylococcus aureus. The most abundant bacteria species in the air of the nursing care institution is E. coli.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号