首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   21篇
  免费   0篇
废物处理   7篇
环保管理   1篇
污染及防治   6篇
评价与监测   6篇
社会与环境   1篇
  2015年   1篇
  2013年   2篇
  2012年   1篇
  2010年   2篇
  2009年   2篇
  2008年   4篇
  2006年   1篇
  2003年   6篇
  1999年   1篇
  1994年   1篇
排序方式: 共有21条查询结果,搜索用时 31 毫秒
1.
Urban atmospheric environment contains many trace organic pollutants that are related to the incomplete fuel combustion in domestic heating, industrial plants and automobile traffic. Removal of these pollutants from the atmosphere takes place through wet and dry deposition as well as chemical transformations. In this study, concentrations of polycyclic aromatic hydrocarbons (PAHs) in wet deposition samples were determined at an urban site of Turkey. Wet and dry deposition samples were collected using Andersen Rain Sampler. The sampler was modified accordingly for the collection of organic pollutants. Collected samples were preconcentrated by using solid phase extraction (SPE) disks and consecutively analyzed by Gas Chromatography-Mass Spectrometry (GC-MS). Among the 13 compounds quantified in this study, anthracene, fluoranthene, and pyrene were found more frequently and at elevated concentrations (202, 271 and 260 ng L-1 mean concentrations, respectively).Concentrations of PAHs were found to be high in winter period.  相似文献   
2.
The concentrations of heavy, trace elements and major ions measuredin the Uluda and Bursa aerosols were investigated to assess size distributions, spatial and temporal variability, sources and source regions affecting the composition of aerosols in Uluda and Bursa. A total of 81 samples were collected in two sites, one in Bursa city and another in the Uluda Mountain during two sampling campaigns. Daily samples were collected using a high volume sampler on Whatman 41 cellulose filters in Uluda, while three days interval samples were collected in Bursa using an automatic dichotomous sampler on PTFE Teflon filters. Samples were analysed for 15 trace and heavy metals (Al, Fe, Ba, Na, Mg, K, Mn, Ca, Cu), (V, Pb, Cd, Cr, Ni, Zn), and 4 major ions (SO4 2-, NO3 -, Cl-), (NH4 +) using ICP-AES, GFAAS, HPLC and UV/VIS Spectrophotometer,respectively. In general, concentrations of the metals measured inUluda aerosols were lower than those in Bursa. The concentrations of crustal elements were higher in summer than winter, while anthropogenic elements had higher concentrations in winter than summer. Most of the mass of crustal elements was concentrated in the coarse mode while the mass of the heavy metals was concentrated in the fine mode. Factor analysis revealed four factors with sources including crustal, industrial and combustion. Back trajectory calculations were used to determine long range contributions. These calculations showed that contributions were mostly from European countries, former Soviet Union countries, Black Sea and North Africa.  相似文献   
3.
A conditional time-averaged gradient (COTAG) system has been developed to provide direct long-term (weekly to monthly) average flux gradient measurements for a range of trace gases, between land and atmosphere. Over daily periods, atmospheric conditions can range from high stability, where the vertical gradients of ambient concentration are enhanced due to very small diffusivity, to highly unstable conditions, in which concentration gradients are small due to the intense turbulent activity of the surface layer. The large vertical gradients generated by high stability would bias the estimate of the actual flux: to avoid this, the COTAG system samples conditionally, within a carefully refined range of stability. A comparison with a continuous flux gradient system suggested that the removal of stable conditions from the sampling period does not substantially modify the evaluation of the long-term fluxes.  相似文献   
4.
Air pollution and groundwater pollution in conjunction with agricultural activity were investigated in Antayla province on the Turkish Mediterranean coast. The air pollution was investigated in terms of gas-phase nitric acid (HNO3), sulfur dioxide (SO2), ammonia (NH3), and particulate matter for a 6-month period in the atmosphere using a "filter pack" system, which was developed and optimized in our laboratory. Ozone was measured by using an automated analyzer. Among all of the gas-phase pollutants, HNO3 had the lowest concentration (0.42 microg x m(-3)) followed by NH3. Agricultural activities seem to be the major source of observed NH3 in the air. The current state of water pollution was investigated in terms of organochlorine and organophosphorus pesticides around the greenhouses, in which mainly tomato, pepper, and eggplant are cultivated. Water samples were collected from 40 points, 28 of which were wells and 12 of which were surface water. The pesticide concentrations in water samples were determined by means of solid-phase extraction (SPE) followed by a gas chromatography (GC)-electron capture detector (ECD)/nitrogen phosphorus detector (NPD) system. In general, surface water samples were more polluted by the pesticides than groundwater samples. The most frequently observed pesticides were chlorpyriphos (57%) and aldrin (79%) in groundwater, and chlorpyriphos (75%), aldrin, and endosulfan sulfate (83%) in surface water samples. The highest concentrations were observed for fenamiphos (394.8 ng/L) and aldrin (68.51 ng/L) in groundwater, and dichlorvos (322.2 ng/L) and endosulfan sulfate (89.5 ng/L) in surface water samples. At least one pesticide had a concentration above the health limit in 38% of all the water samples analyzed.  相似文献   
5.
ABSTRACT

A stable rare-earth isotopic tracer was used to measure the deposition of KNO3 particles on soybean leaves by direct measurement of the tracer on the plant surfaces by thermal-ionization mass spectrometry. Submicrometer particles, made from a solution containing 3 |mg mL-1 neodymium isotope (148Nd, 87.9%) and 1,000 mg mL-1 KNO3, were dispersed with a two-fluid nozzle and released upwind of a soybean field. Total suspended- and size-fractionated-aerosol particles were collected on an open-face filter and in a micro-orifice impactor, respectively, at a distance of 40 m from the release point. Soybean leaves exposed to the plume were collected at distances ranging from 25 to 100 m. As little as 5.5 pg of the tracer (i.e., excess 148Nd) was detected in soybean leaves at signal-to-noise ratios ranging from 7,500 to 240,000, in the presence of 200 to 2,700 pg of naturally occurring Nd. The dry-particle deposition velocity, determined from the ratio of the aerial concentration and directly deposited aerosol (geometric mass mean diameter, 0.20 mm) flux, and its corresponding analytical uncertainty were 0.30 cm sec-1 and 2.5%, respectively.  相似文献   
6.
Nose-level measurements of air toxics were made along a busy urban street in Ottawa, Canada for 2 hr periods during morning, noon, and afternoon rush hours in the winter and summer of 2000. Measurements were also made in a commuter car and a transit bus during morning and afternoon commutes in 2000. The main objectives of the study were to establish a database, to determine temporal and seasonal variations and to determine the contribution of motor vehicle traffic to the measured toxic substance concentrations. Ottawa is an appropriate choice of location for the measurement of motor vehicle related toxic and reactive compounds, as it has virtually no industrial sources that could be contributing to the ambient loadings. Samples were collected for a total of 165 volatile organic compounds and 25 carbonyl compounds. Sampling and analytical methodologyare discussed and results are presented. Toluene, ethylene andformaldehyde were the most abundant pollutants in Ottawa during both winter and summer. Total non-methane hydrocarbon concentrationwas measured as 100 g m-3 at nose-level measurements in Ottawa.  相似文献   
7.
In this study, seawater samples were subjected to microbiological and physicochemical analysis (water temperature, pH, Secchi disc depth and ammonia) in the Prince Islands which are located in Marmara Sea, being one of the most popular swimming areas in Istanbul. The monitoring program of the study has been carried out in the summer for 6 weeks at eight stations around the Prince Islands. Measured total coliform values were between 5 ± 2 and 26 ± 55 and faecal coliform values were between 4 ± 2 and 24 ± 50 in the monitoring stations. A statistical study has been conducted to find the relationship between total and faecal coliform concentrations, and t tests were applied. There was no significant difference in each location of the Islands, except one location. The results were evaluated by comparing with national and EU bathing water standards. Results of the study show that deep sea discharges and sea currents contribute dilution of coliform concentration in a positive way, and locations near coastal zones of the islands have acceptable values which are required by the regulations.  相似文献   
8.
The Istanbul composting and recycling plant, constructed in 2001, is one of the few composting plants in Turkey. During test operations of the plant, it was reported that the weight of the oversize materials (OM) above a 80-mm sieve was about 40% of the total incoming waste. They mainly consist of plastic bags that were full of garbage, which resulted in operational problems in the plant. In this paper, the composition of OM was determined and evaluated, particularly to find the economic losses in the plant. It was determined that approximately 58% of the OM transferred to the landfill area due to operational failures and interruptions could be used at the plant with improved operational conditions. Otherwise, the plant would realize an annual economic loss of about 640,800 US$. Compost quality in the plant has been satisfactory, but source separated collection, at least the separation of the wet from the dry fraction, is needed to increase the amount of compost and recovered materials.  相似文献   
9.
Lignite powered electric generation plants result in increasing environmental problems associated with gaseous emissions and the disposal of ash residues. Especially, low quality coals with high ash content cause enormous quantities of both gaseous and solid fly ash emissions. The main problem is related to the disposal of fly ash, which, in many cases, contains heavy metals. It is known that toxic trace metals may leach when fly ash is in contact with water. In this study, fly ash samples obtained from the thermal power plant in the town of Can in Turkey were investigated for leachability of metals under different acidic and temperature conditions. The experimental results show that a decrease in pH of the leachant favors the extraction of metal ions from fly ash. A significant increase in the extraction of arsenic, cadmium, chromium, zinc, lead, mercury, and selenium ions from the ash is attributed to the instability of the mineral phases. These heavy metals concentrations increase with respect to increasing acidic conditions and temperature. Peak concentrations, in general, were found at around 30°C.  相似文献   
10.
Comparison of black carbon (BC) measurements obtained by two methods was performed for aerosols samples collected on Whatman 41 (W-41) filters, using an optical method (Magee Scientific Optical Transmissometer Model OT-21) and a thermal-optical method (Sunset Laboratory Thermal-optical analyzer). Samples were collected from four sites: Albany (a small urban site, NY), Antalya (coastal site, Turkey), Whiteface Mountain (remote site, NY) and Mayville (rural site, NY). At Albany, comparison between the two methods showed excellent agreement; a least-squares regression line yielded a slope of 1.02, and r2 = 0.88. Similar comparisons at Antalya (slope of 1.02, r2 = 0.5) and Whiteface Mountain (slope of 0.92 and r2 = 0.58) also gave very good relationship. At Mayville, the relationship between the two methods yielded somewhat lower regression: a slope of 0.75, and r2 = 0.44. The data from the four locations, when plotted together, yielded an excellent agreement: a slope of 0.91, and r2 of 0.84. Based on our measurements, it appears that optical measurement using the OT-21 can be successfully applied to determination of BC in W-41 filters. However, because of the variability in the chemical composition of BC aerosol at different locations, it is suggested that the calibration of OT-21 when using W-41 filters should be performed with a statistically significant numbers of samples for specific sites.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号