排序方式: 共有39条查询结果,搜索用时 109 毫秒
1.
2.
Baiwen M Siqi Wu Bodong Wang Zenglu Qi Yaohui Bai Huijuan Liu Jiuhui Qu Ruijun Wu 《环境科学学报(英文版)》2020,32(4):10-19
Cake layer formation is inevitable over time for ultrafiltration (UF) membrane-based drinking water treatment. Although the cake layer is always considered to cause membrane fouling, it can also act as a “dynamic protection layer”, as it further adsorbs pollutants and dramatically reduces their chance of getting to the membrane surface. Here, the UF membrane fouling performance was investigated with pre-deposited loose flocs in the presence of humic acid (HA). The results showed that the floc dynamic protection layer played an important role in removing HA. The higher the solution pH, the more negative the floc charge, resulting in lower HA removal efficiency due to the electrostatic repulsion and large pore size of the floc layer. With decreasing solution pH, a positively charged floc dynamic protection layer was formed, and more HA molecules were adsorbed. The potential reasons were ascribed to the smaller floc size, greater positive charge, and higher roughness of the floc layer. However, similar membrane fouling performance was also observed for the negative and positive floc dynamic protection layers due to their strong looseness characteristics. In addition, the molecular weight (MW) distribution of HA also played an important role in UF membrane fouling behavior. For the small MW HA molecules, the chance of forming a loose cake layer was high with a negatively charged floc dynamic protection layer, while for the large MW HA molecules it was high with a positively charged floc dynamic protection layer. As a result, slight UF membrane fouling was induced. 相似文献
3.
通过中试试验考察了高锰酸盐复合药剂(PPC)预氧化强化混凝/沉淀/超滤的组合工艺的除藻效能以及PPC预氧化对藻类引起的膜污染的缓解作用,并对其机理进行了探讨.试验结果表明,投加0.6mg·L-1PPC能使预处理阶段对藻类的平均去除率提高约28%.组合工艺处理高藻水时,PPC预氧化通过强化预处理,降低膜表面的污染负荷,对藻源污染物引起可逆和不可逆污染均具有一定的缓解作用.化学清洗试验结果表明,碱洗对超滤膜TMP恢复效果远远强于酸洗,因而有机物是超滤膜处理高藻水时的主要污染物质. 相似文献
4.
The characteristics of dissolved organic matter (DOM) and bromide ion concentration have a significant influence on the formation of disinfection by-products (DBPs). In order to identify the main DBP precursors, DOM was divided into five fractions based on molecular weight (MW), trihalomethane formation potential and haloacetic acid formation potential were determined for fractions, and the change in contents of different fractions and total DBPs during treatment processes (pre-chlorination, coagulation, sand filtration, disinfection) were studied. Moreover, the relationship between bromide concentration and DBP generation characteristics in processes was also analyzed. The results showed that the main DBP precursors were the fraction with MW < 1 kDa and fraction with MW 3−10 kDa, and the DBP''s generation ability of lower molecular weight DOM (< 10 kDa) was higher than that of higher molecular weight DOM. During different processes, pre-chlorination and disinfection had limited effect on removing organics but could alter the MW distribution, and coagulation and filtration could effectively remove organics with higher MW. For DBPs, trihalomethanes (THMs) were mainly generated in pre-chlorination and disinfection, while haloacetic acids (HAAs) were mostly generated during pre-chlorination; coagulation and sand filtration had little effect on THMs but resulted in a slight removal of HAAs. In addition, the results of ANOVA tests suggested that molecular sizes and treatment processes have significant influence on DBP formation. With increasing bromide concentration, the brominated DBPs significantly increased, but the bromine incorporation factor in the processes was basically consistent at each concentration. 相似文献
5.
6.
Industrial wastewater pre-treatment for heavy metal reduction by employing a sorbent-assisted ultrafiltration system 总被引:1,自引:0,他引:1
This work examined the adoption of a sorbent-assisted ultrafiltration (UF) system for the reduction of Pb(II), Cu(II), Zn(II) and Ni(II) from industrial wastewater. In such a system metals were removed via several processes which included precipitation through the formation of hydroxides, formation of precipitates/complexes among the metal ions and the wastewater compounds, adsorption of metals onto minerals (bentonite, zeolite, vermiculite) and retention of insoluble metal species by the UF membranes. At pH = 6 the metal removal sequence obtained by the UF system was Pb(II) > Cu(II) > Zn(II) > Ni(II) in mg g−1 with significant amount of lead and copper being removed due to chemical precipitation and formation of precipitates/complexes with wastewater compounds. At this pH, zinc and nickel adsorption onto minerals was significant, particularly when bentonite and vermiculite were employed as adsorbents. Metal adsorption onto zeolite and bentonite followed the sequence Zn(II) > Ni(II) > Cu(II) > Pb(II), while for vermiculite the sequence was Ni(II) > Zn(II) > Cu(II) > Pb(II) in mg g−1. The low amount of Pb(II) and Cu(II) adsorbed by minerals was attributed to the low available lead and copper concentration. At pH = 9 the adoption of UF could effectively reduce heavy metals to very low levels. The same was observed at pH = 8, provided that minerals were added. The prevailing metal removal process was the formation of precipitates/complexes with wastewater compounds. 相似文献
7.
This paper presents result from an economic and technical point of view evaluation study, which has sought to establish the potential for replacing well-water that is currently used at the Piaggio industrial plant in Pontedera with recycled wastewater. The study is based upon a pilot wastewater treatment plant, which has been used to test wastewater treatment processes and to compare with achieved quality of recycled waters with that of water drawn on-site from physical/chemical pre-treatment and end with a reverse osmosis and air stripping stage. However, after the physical/chemical pre-treatment, the first option uses oxidation with ozone followed by activated carbon filtration, whereas the second method uses ultrafiltration. The first method is more effective at reducing chemical oxygen demand (COD) whereas the second method is more effective in removing bacteria. Nonetheless, both methods deliver water for re-use of a quality comparable with or better than that of well-water. In principle, the reverse osmosis permeate from either process could be re-used in all production phases at the industrial plant. However, the method base upon oxidation with ozone followed by activated carbon filtration is preferred, because, the process is simpler and continuous. The economic analysis of this process gives an estimated cost of Euro 0.55 per m3 for treated water. This compares favorably with other treatment processes and with the cost of other forms of water supply, which are projected to increase in any case. 相似文献
8.
Lu Ao Wenjun Liu Yang Qiao Cuiping Li Xiaomao Wang 《Frontiers of Environmental Science & Engineering》2018,12(6):9
9.
Bryan Butter Paola Santander Guadalupe del C. Pizarro Diego P. Oyarzún Federico Tasc Julio Sánchez 《环境科学学报(英文版)》2021,33(3):304-312
Chromium (Cr) is used in many manufacturing processes, and its release into natural waters is a major environmental problem today. Low concentrations of Cr(VI) are toxic to human health and living organisms due to the carcinogenic and mutagenic nature of this mineral. This work examined the conversion of Cr(VI) to Cr(III) via electrochemical reduction using gold electrode in an acidic sodium alginate (SA) solution and subsequent removal of the produced Cr(III)-SA by the polymer-enhanced ultrafiltration (PEUF) technique. A solution of SA in nitric acid was used both as an electrolytic medium during the voltammetric measurements and bulk electrolysis and as an extracting agent during the PEUF technique. The electroanalysis of Cr(VI) was performed by linear sweep voltammetry in the presence of acidic SA solution to study its voltammetric behavior as a function of the Cr(VI) concentration, pH, presence of Cr(III), SA concentration and scan rate. In addition, the quantitative reduction of Cr(VI) to Cr(III) was studied through the bulk electrolysis technique.The results showed efficient reduction with well-defined peaks at approximately 0.3 V vs. Ag/AgCl, using a gold working electrode. As the pH increased, the reduction signal strongly decreased until its disappearance. The optimum SA concentration was 10 mmol/L, and it was observed that the presence of Cr(III) did not interfere in the Cr(VI) electroanalysis. Through the quantitative reduction by bulk electrolysis in the presence of acidic SA solution, it was possible to reduce all Cr(VI) to Cr(III) followed by its removal via PEUF. 相似文献
10.