首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Wind flow and turbulence within the urban canopy layer can influence the heating and ventilation of buildings, affecting the health and comfort of pedestrians, commuters and building occupants. In addition, the predictive capability of pollutant dispersion models is heavily dependent on wind flow models. For that reason, well-validated microscale models are needed for the simulation of wind fields within built-up urban microenvironments. To address this need, an inter-comparison study of several such models was carried out within the European research network ATREUS. This work was conducted as part of an evaluation study for microscale numerical models, so they could be further implemented to provide reliable wind fields for building energy simulation and pollutant dispersion codes. Four computational fluid dynamics (CFD) models (CHENSI, MIMO, VADIS and FLUENT) were applied to reduced-scale single-block buildings, for which quality-assured and fully documented experimental data were obtained. Simulated wind and turbulence fields around two surface-mounted cubes of different dimensions and wall roughness were compared against experimental data produced in the wind tunnels of the Meteorological Institute of Hamburg University under different inflow and boundary conditions. The models reproduced reasonably well the general flow patterns around the single-block buildings, although over-predictions of the turbulent kinetic energy were observed near stagnation points in the upwind impingement region. Certain discrepancies between the CFD models were also identified and interpreted. Finally, some general recommendations for CFD model evaluation and use in environmental applications are presented.  相似文献   

2.
Air inside poultry houses must be removed on a regular basis to prevent excess of heat, particles and noxious gases that can imperil animals. To cope with this issue, natural ventilation could be an effective method when assisted by accurate predictions. This study investigates air discharges caused by natural ventilation of a poultry house by means of a three-dimensional computational fluid dynamics (CFD) model. It solves the governing equations of momentum, heat and mass transport, radiative transfers and animal-generated heat. Wind directions of 0°, 36° and 56° (0° corresponds to a wind blowing perpendicular to the ridgeline) were investigated; the CFD model predictions achieved a RMSE of 1.2 °C and 0.6 g[H2O] kg?1 [dry air] for internal temperature and absolute humidity, respectively, when air blew with an angle of 36°. Air renewal rates (ARR) were 39.5 (±?1.9), 34.9 (±?2.2) and 33.6 (±?1.7) volumes of the building per hour, when air blew at 0°, 36° and 56°, respectively. Such ARR predictions served to know how the gases contained in air would likely spread downstream from the building in order to define regions of potentially high gas concentration that could endanger neighbouring habitable facilities.  相似文献   

3.
Flow and Pollutant Dispersion in Street Canyons using FLUENT and ADMS-Urban   总被引:1,自引:0,他引:1  
This paper is devoted to the study of flow within a small building arrangement and pollutant dispersion in street canyons starting from the simplest case of dispersion from a simple traffic source. Flow results from the commercial computational fluid dynamics (CFD) code FLUENT are validated against wind tunnel data (CEDVAL). Dispersion results from FLUENT are analysed using the well-validated atmos pheric dispersion model ADMS-Urban. The k − ε turbulence model and the advection-diffusion (AD) method are used for the CFD simulations. Sensitivity of dispersion results to wind direction within street canyons of aspect ratio equal to 1 is investigated. The analysis shows that the CFD model well reproduces the wind tunnel flow measurements and compares adequately with ADMS-Urban dispersion predictions for a simple traffic source by using a slightly modified k − ε model. It is found that a Schmidt number of 0.4 is the most appropriate number for the simulation of a simple traffic source and in street canyons except for the case when the wind direction is perpendicular to the street canyon axis. For this last case a Schmidt number equal to 0.04 gives the best agreement with ADMS-Urban. Overall the modified k − ε turbulence model may be accurate for the simulation of pollutant dispersion in street canyons provided that an appropriate choice for coefficients in the turbulence model and the Schmidt number in the diffusion model are made.  相似文献   

4.
提出了一种可伸缩延长气体采样装置,并将其与现场气体监测仪器配套使用。初步考察了延长采样装置中Teflon采样管长度对现场监测结果可能产生的影响,并对监测站实验室楼顶废气排出筒气体进行了实际样品监测。结果表明,该装置可有效提高现场应急监测的安全防护保障效果,增加可监测区域范围,使现场应急监测工作能够为突发性环境污染事件的处置提供更多技术支持。  相似文献   

5.
戴泳 《干旱环境监测》1994,8(3):173-175,183
应用数理统计中抽样理论,对瑞安市环境噪声监测点进行了优化组合,方法简单易行,兼顾了功能区特征,减少了测点数,并能达到要求的准确性。  相似文献   

6.
Methods for estimating airborne contaminant concentrations at specific locations within enclosed spaces, such as mathematical models and computational fluid dynamics (CFD), often are validated against directly measured concentrations. However, concentration variation with time introduces uncertainty into the measured concentration. Failure to determine monitoring time requirements can lead to errors in quantifying representative concentrations, which are likely to be attributed to errors in the method being validated. In the current study, to obtain the representative concentrations at multiple locations with a direct reading instrument, we used the standard deviation ratio (SDR) method to determine the required minimum monitoring time within a specified precision limit. To demonstrate the use of the SDR approach in constructing precision confidence intervals, tracer gas concentrations at nine sampling locations in an experimental room were measured to obtain population parameters. Three flow rates of 0.9, 3.3 and 5.5 m(3) min(-1) were employed and contaminant concentrations were measured using a photoionization analyser. Monitoring time requirements varied substantially with location within the room and were strongly dependent upon the flow rate of air through the room. The proposed method would be very useful for industrial hygienists and indoor air researchers who sometimes need to obtain several hundred measured concentrations for validation purposes or to perform tests under repeatable conditions in enclosed spaces. This study also showed that the proposed method can be used to devise efficient indoor monitoring strategies.  相似文献   

7.
环境监测实验室样品管理是质量管理的重要环节,样品管理的智能化、信息化将大幅提升实验室的管理水平。通过分析当前监测实验室样品管理现状和不足,借鉴相关行业样品智能物流管理系统应用经验,结合江苏省环境监测中心新建的监测实验大楼,开展环境监测样品智能物流管理系统设计研究。提出,考虑环境监测样品接收、任务分配、样品交接、样品留存各个环节,以样品属性为基准进行样品管理系统设计;同时,结合物联网集成管控、气动传输和机器人输送技术,构建包含分布式存储工作站和密集型土壤样品库的样品智能物流管理系统,实现高效、智能、规范的样品管理目标。  相似文献   

8.
Effluent from sewage treatment plants has been associated with a range of pollutant effects. Depending on the influent composition and treatment processes the effluent may contain a myriad of different chemicals which makes monitoring very complex. In this study we aimed to monitor relatively polar organic pollutant mixtures using a combination of passive sampling techniques and a set of biochemistry based assays covering acute bacterial toxicity (Microtox), phytotoxicity (Max-I-PAM assay) and genotoxicity (umuC assay). The study showed that all of the assays were able to detect effects in the samples and allowed a comparison of the two plants as well as a comparison between the two sampling periods. Distinct improvements in water quality were observed in one of the plants as result of an upgrade to a UV disinfection system, which improved from 24x sample enrichment required to induce a 50% response in the Microtox assay to 84x, from 30x sample enrichment to induce a 50% reduction in photosynthetic yield to 125x, and the genotoxicity observed in the first sampling period was eliminated. Thus we propose that biochemical assay techniques in combination with time integrated passive sampling can substantially contribute to the monitoring of polar organic toxicants in STP effluents.  相似文献   

9.
基于决策树技术及在线监测的水质预测   总被引:1,自引:2,他引:1       下载免费PDF全文
利用北方某城市水源的水质在线监测系统,建立了基于决策树技术,具有较强可视性和实际应用,以及能预测次日源水中叶绿素水平的决策树模型.该模型将某城市水源在线监测的溶解氧和太阳辐射照度数据转换计算为每日平均标准偏差及均值,并与每日定时取样测定的叶绿素含量一起作为预测因子,通过将115组数据的前100组数据作为训练集建立预测次日叶绿素水平决策树模型,并采用后15组数据进行模型的仿真预测检验,结果只有3 d的预测出错,预测准确率达80%.并讨论了模型建立对数据的要求及解读预测规则等问题.  相似文献   

10.
The long-term water quality monitoring program implemented by the Massachusetts Water Resources Authority in 1992 is extensive and has provide substantial understanding of the seasonality of the waters in both Boston Harbor and Massachusetts Bay and the response to improvements in effluent quality and offshore transfer of the effluent in September 2000. The monitoring program was designed with limited knowledge of spatial and temporal variability and long-term trends within the system. This led to an extensive spatial and temporal sampling program. The data through 2003 showed high correlation within physical parameters measured (e.g., salinity, dissolved oxygen) and in biological measures such as chlorophyll fluorescence. To address the potential sampling redundancies in the measurement program, an assessment of the impact of reduced levels of monitoring on the ability to make water quality decisions was completed. The optimization was conducted by applying statistical models that took into account whether there was evidence of a seasonal pattern in the data. The optimization used model survey average readings to identify temporal fixed effects, model survey-average-corrected individual station readings to identify spatial fixed effects, corrected the individual station readings for temporal and spatial fixed effects and derived a correlation model for the corrected data, and applied the correlation model to characterize the correlation of annual average readings from reduced monitoring programs with true parameter levels. Reductions in the number of sampling stations were found less detrimental to the quality of the data for annual decision-making than reductions in the number of surveys per year, although there is less of a difference in this regard for dissolved oxygen than there is for chlorophyll. The analysis led to recommendations for a substantially lower monitoring effort with minimal loss of information. The recommendation supported an annual budget savings of approximately $183,000. Most of the savings was from fewer surveys as approximately $21,000 came from the reduction in the number of stations monitored from 21 to 7 and associated laboratory analytical costs.  相似文献   

11.
A 3-D Eulerian-Lagrangian approach to moving vehicles is presented that takes into account the traffic induced flow rate and turbulence. The method is applied to pollutants dispersion in a street canyon. The approach is based on CFD calculations using Eulerian approach to the continuous phase and Lagrangian approach to the "discrete phase" of moving objects - vehicles. A commercial CFD code StarCD was used into which the Lagrangian model was integrated. As an example a street canyon is taken into consideration. It has the length of 50 m and the aspect ratio of 1.27. The speed of wind was assigned values of 4, 7 and 12 m/s at the altitude of 300 m. The total height of the domain is 115 m. In the study different traffic situations are considered, namely one-way and two-way traffic with different traffic rates per lane. The predictions show that different traffic situations affect pollutants dispersion in the street canyon and that there are also differences in the pollutants dispersion in case of one- and two-way traffic.  相似文献   

12.
乌鲁木齐市环境应急监测体系存在的问题及对策   总被引:1,自引:0,他引:1  
乌鲁木齐市已发生多起突发性环境污染事故,虽然环境监测部门在为政府和上级主管部门提供公正、科学和规范的技术支持方面发挥了不可替代的作用,但受经验、资金和技术等方面的制约,当前应急监测体系还存在着监测预案不完善、设备配置偏低、信息化程度和技术含量不高等突出问题。为着力解决这些问题,应完善具体的环境风险源污染事故应急监测预案,建立基于GIS平台的环境应急信息系统,增加现场及实验室仪器配置,并通过完善培训考核程序和系统化演练程序来加强应急监测队伍建设。  相似文献   

13.
简述了水污染源在线监测设备系统集成的必要性,分析了目前系统集成中存在的问题,以及应采取的对策。按照国家有关规范要求,对现场端的在线监测设备进行科学的综合布局,并从采水、配水、预处理、控制、分析、数据采集与传输、辅助等构成单元,提出了有关水污染源在线监测设备系统集成的方案。  相似文献   

14.
The impact of the street configurations on pollutants dispersion from vehicles exhausts within urban canyons was numerically investigated using a computational fluid dynamics (CFD) model. Three-dimensional flow and dispersion of gaseous pollutants were modeled using standard kappa - epsilon turbulence model, which was numerically solved based on Reynolds-averaged Navier-Stokes equations by the commercial CFD code FLUENT. The concentration fields in the urban canyons were examined in three cases of street configurations: (1) a regular-shaped intersection, (2) a T-shaped intersection and (3) a Skew-shaped crossing intersection. Vehicle emissions were simulated as double line sources along the street. The numerical model was validated against wind tunnel results in order to optimize the turbulence model. Numerical predictions agreed reasonably well with wind tunnel results. The results obtained indicate that the mean horizontal velocity was very small in the center near the lower region of street canyon. The lowest turbulent kinetic energy was found at the separation and reattachment points associated with the corner of the down part of the upwind and downwind buildings in the street canyon. The pollutant concentration at the upwind side in the regular-shaped street intersection was higher than that in the T-shaped and Skew-shaped street intersections. Moreover, the results reveal that the street intersections are important factors to predict the flow patterns and pollutant dispersion in street canyon.  相似文献   

15.
A passive sampling device, developed for personal monitoring of airborne dust levels in industry, has been tested as a site sampler in the urban environment. The device weighs approximately 15g and the essential sampling element is a small disc of electret material (polymer carrying a permanent electric charge). During use it captures particles by electrical attraction, at a rate that depends upon their electrical mobility, but which is independent of the rate at which air flows past the sampler. It collects measurable quantities of particulate, though the sample size tends to be small and correlation with results from conventional samples has not yet been established. Samplers have been exposed to urban particulate for periods of up to seven days, without the electret suffering unacceptable loss of electric charge. It has been shown to be potentially useful for long-term monitoring, a situation in which dispensing with a power source is particularly useful. Being small, the passive sampler is easy to hide or camouflage. It has potential for multiple simultaneous site sampling and for monitoring personal environmental exposure.  相似文献   

16.
内陆水环境污染监测的多时相遥感信息模型   总被引:8,自引:0,他引:8  
介绍了遥感水质监测的基本原理,对遥感技术在水质监测领域的国内外发展现状进行了归纳分析,并论述了建立多时相、通用型内陆水环境污染遥感监测模型的可行性,最后以湘江长沙段为研究区域,创建了适用于DO、CODCr、CODMn、BOD和TN的水污染遥感因子和相应的多时相遥感信息模型。  相似文献   

17.
A modular separation-based fiber-optic sensor (SBFOS) with an integrated electronically controlled injection device is described for potential use in remote environmental monitoring. An SBFOS is a chemical monitor that integrates the separation selectivity and versatility afforded by capillary electrophoresis with the remote and high sensitivity capabilities of fiber-optic-based laser-induced fluorescence sensing. The detection module of the SBFOS accommodates all essential sensing components for dual-optical fiber, on-capillary fluorescence detection. An injection module, similar to injection platforms on micro-analysis chips, is also integrated to the SBFOS. The injection module allows for electronically controlled injection of the sample onto the separation capillary. The design and operational characteristics of the modular SBFOS are discussed in this paper. A micellar electrokinetic capillary chromatography mode of separation is employed to evaluate the potential of the sensor for in situ monitoring of neutral toxins (aflatoxins). The analytical figures of merit for the modular SBFOS include analysis times of between 5 and 10 min, separation efficiencies of approximately 10(4) theoretical plates, detection limits for aflatoxins in the mid-to-low nanomolar range, and controllable operation that results in sensor performance that is largely immune to sample matrix effects.  相似文献   

18.
Water ecosystems are threatened by accidental spills of pollution. Rapidity and trueness of information gathering the biological impact of accidental pollution is crucial for the efficiency of the minimisation of possible deterioration of ecosystems and for success in detecting the source of pollution. Due to the randomised occurrence of accidental spills the only way to quickly detect hazardous situations is to perform continuous monitoring of surface water quality. The current situation in the field of early warning in the International Odra (Oder) River basin is not satisfactory. The actual number of monitoring stations and list of routinely continuously monitored parameters are not able to meet the needs of sensitive and rapid detection of biological impact of accidental pollution spills. An effort to change this unfavourable situation was the reason for the offer survey, selection and a model operation of a commercially produced biological monitoring device. This apparatus was located on the border-line profile on the territory of the Czech Republic and represented the first and only one tool of continual biological monitoring of surface water quality in the International Odra (Oder) River Basin. The selected apparatus was the Daphnia Toximeter produced by the firm bbe Moldaenke (Kiel, Germany). This device exploited for rapid detection of changes of biological quality of surface water evaluation of behavioural response of monitoring organisms??daphnids. Five years of model operation proved its suitability for early warning purposes. The apparatus was reliable in function and sensitive enough to detect the deterioration of the biological quality of the river water. The given examples document its applicability not only for detection of accidental spills but also of illegal emissions of pollution, which are very often toxic.  相似文献   

19.
In this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling took place under flow-controlled conditions. Aerosols were extracted from the filters with water, in defined conditions, and the water-soluble fraction was quantified by ion chromatography (IC) for the determination of inorganic anions (Cl?, NO3 ? and SO4 2?). Equivalent sampling through the various channels was validated. Validation was based on the metrological compatibility of the content results for the various filters. Ion masses are metrologically equivalent when their absolute difference is smaller than the respective expanded uncertainty. When this condition is verified, the studied multifold device produces equivalent samples.  相似文献   

20.
2015年中央全面深化改革领导小组审议通过《生态环境监测网络建设方案》,推动全国生态环境监测网络建设取得重大成就。对照《生态环境监测网络建设方案》提出的"全面设点,完善生态环境监测网络"方面的任务与要求,对生态环境监测网络建设成效进行客观评估,并对生态环境监测面临的形势与不足进行了深入剖析。针对加强生态环境监测网络建设、探索生态环境监测多手段融合应用模式、强化生态环境监测数据智慧应用等方面提出了当前及今后中长期生态环境监测发展的相关建议。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏