首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 726 毫秒
1.
A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.  相似文献   

2.
The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.2 l min(-1). The formed isocyanate-DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. The sampler was investigated in regard to collection principle and extraction of the formed derivatives with good results. The possibility to store the sampler before sampling and to perform long-term sampling was demonstrated. Field extraction of the sampler was not necessary, as there was no difference between immediately extracted samples and stored ones (2 days). In comparative studies, the sampler was evaluated against a reference method, impinger-filter sampling with DBA as reagent. The ratios between the results obtained with the sampler and the reference in a test chamber at a relative humidity (RH) of 45% was in the range of 83-109% for isocyanates formed during thermal decomposition of PUR. At RH 95%, the range was 72-101% with the exception of isocyanic acid. In two field evaluations, the ratios for fast curing 2,4'- and 4,4'-methylene bisphenyl diisocyanate (MDI) was in the range 81-113% and for the 3-ring MDI the range was 54-70%. For the slower curing 1,6-hexamethylene diisocyanate (HDI) and HDI isocyanurate, the ratios were in the range 78-145%. In conclusion, the solvent-free sampler is a convenient alternative in most applications to the more cumbersome impinger-filter sampler.  相似文献   

3.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   

4.
Air sampling for (1 → 3)-β-D-glucan may be a good method for assessing inhalation exposure to airborne fungi. Pre-sampling contamination of filter media used for sampling (1 → 3)-β-D-glucan may lead to substantial exposure measurement errors. Using the Limulus amebocyte lysate assay, we tested for pre-sampling levels of (1 → 3)-β-D-glucan on three types of filters-mixed cellulose ester (MCE)[1 brand], glass fiber (GF)[1 brand], and polycarbonate (PC)[5 brands]. Levels of (1 → 3)-β-D-glucan on MCE filters exceeded 4586.1 pg per filter. Levels on GF filters averaged 135.3 (± 28.9) pg per filter (range = 94.8-160.4 pg per filter) and levels on PC filters averaged 152.4 (± 236.1) pg per filter (range = non-detectable-1760.7 pg per filter). Efforts to clean MCE and GF filters were unfeasible or unsuccessful. Sonicating PC filters for two hours in ethanol, followed by a wash in pyrogen-free water, effectively eliminated measured levels of (1 → 3)-β-D-glucan on four brands of PC filters, as compared to untreated PC filters. This pretreatment process did not appear to physically damage the PC filters. Air sampling results highlighted the potentially problematic contamination of untreated PC filters. Ensuring that sampling media are free of (1 → 3)-β-D-glucan before sampling is crucial to accurately measure levels of (1 → 3)-β-D-glucan exposure, especially in environments where levels of (1 → 3)-β-D-glucan are low.  相似文献   

5.
A methodology for workplace air monitoring of aromatic and aliphatic, mono- and polyisocyanates by derivatisation with di-n-butylamine (DBA) is presented. Air sampling was performed using midget impinger flasks containing 10 ml of 0.01 mol l(-1) DBA in toluene and a glass-fibre filter in series after the impinger flask, thereby providing the possibility of collecting and derivatising isocyanates in both the gas and particle phases. Quantification was made by LC-MS, monitoring the molecular ions [MH]+. Air samples taken with this method in car repair shops showed that many different isocyanates are formed during thermal decomposition of polyurethane (PUR) coatings. In addition to isocyanates such as hexamethylene (HDI), isophorone (IPDI), toluene (TDI) and methylenediphenyl diisocyanate (MDI), monoisocyanates such as methyl (MIC), ethyl (EIC), propyl (PIC), butyl (BIC) and phenyl isocyanate (PhI) were found. In many air samples the aliphatic monoisocyanates dominated. During cutting and welding operations, the highest levels of isocyanates were observed. In a single air sample from a welding operation in a car repair shop, the highest concentrations found were: MIC, 290; EIC, 60; PIC, 20; BIC, 9; PhI, 27; HDI, 105; IPDI, 39; MDI, 4; and 2,4-TDI and 2,6-TDI 140 microg m(-3). Monitoring the particle size distribution and concentration during grinding, welding and cutting operations showed that ultrafine particles (< 0.1 microm) were formed at high concentrations. Isocyanates with low volatility were mainly found in the particle phase, but isocyanates with a relatively high volatility such as TDI, were found in both the particle and gas phases.  相似文献   

6.
The dialdehyde glyoxal (ethanedial) is an increasingly used industrial chemical with potential occupational health risks. This study describes the development of a personal sampling methodology for the determination of glyoxal in workroom air. Among the compounds evaluated as derivatizing agents; N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH), 1,2-phenylenediamine (OPDA), 1-dimethylaminonaphthalene-5-sulfonylhydrazine (dansylhydrazine, DNSH) and 2,4-dinitrophenylhydrazine (DNPH), DNPH was the only reagent that was suitable. Several different samplers were evaluated for sampling efficiency of glyoxal in workroom air using DNPH as derivatizing agent; in-house DNPH coated silica particles packed in two different types of glass tubes, impingers containing acidified DNPH solution, filter cassettes containing glass fibre filters coated with DNPH, a commercially available solid phase cartridge sampler originally developed for formaldehyde sampling (Waters Sep-Pak DNPH-silica cartridge), and the commercially available SKC UMEx 100 passive sampler originally developed for formaldehyde sampling. Aldehyde atmospheres for sampler evaluation were generated with an in-house made vapour atmosphere generator coupled to a sampling unit, with the possibility of parallel sampling. The resulting glyoxal-DNPH derivative was determined using both LC-UV and LC-APCI-MS with negative ionization. By far, the highest recovery of glyoxal was obtained employing one of the in-house DNPH coated silica samplers (93%, RSD = 3.6%, n = 12).  相似文献   

7.
烟尘监测时采样滤筒的质量控制   总被引:7,自引:0,他引:7       下载免费PDF全文
介绍了合格滤筒的筛选方法和采样滤筒在实验室分析中的质量控制,分析了影响滤筒称量恒重的原因,指出空气湿度、冷却时间和烘干时间对滤筒称量恒重都有影响.  相似文献   

8.
The objective of this study was to determine filter materials and extraction methods that are appropriate to use for environmental sampling of B. anthracis. Four types of filters were tested: mixed cellulose ester (MCE) with a pore size of 3 microm, polytetrafluoroethylene (PTFE) with pore sizes of 1 and 3 microm, and gelatin with a pore size of 3 microm. Bacillus subtilis var. niger endospores (also known as Bacillus globigii[BG]) were used as a surrogate for B. anthracis. Endospores were collected into Button Inhalable Aerosol Samplers with sampling times of 15 minutes, 1 hour, and 4 hours. Physical collection efficiency was determined by measuring upstream and downstream B. subtilis concentrations with an optical particle counter. Vortexing with ultrasonic agitation and vortexing with shaker agitation extraction methods were evaluated. The MCE, 1 microm PTFE, and gelatin filters provided physical collection efficiencies of 94% or greater. The 3 microm PTFE filter showed inconsistent physical efficiency characteristics between filters. Epifluorescence microscopic analysis of the gelatin filter extraction fluid revealed the presence of contamination by non-culturable bacteria. Mean differences for microbial culturability were not statistically significant for filter materials and extraction methods. However, the vortexing with shaker agitation extraction method resulted in higher total microbial counts in the extraction fluids for MCE and 1 microm PTFE filters when compared to vortexing with ultrasonic agitation. In summary, the MCE and 1 microm PTFE filters in combination with vortexing and shaker extraction demonstrated the best performance for the filter collection and extraction of BG spores.  相似文献   

9.
There is an increasing need to monitor concentrations of polar organic contaminants in the aquatic environment. Integrative passive samplers can be used to assess time weighted average aqueous concentrations, provided calibration data are available and sampling rates are known. The sampling rate depends on environmental factors, such as temperature and water flow rate. Here we introduce an apparatus to investigate the sampling properties of passive samplers using river-like flow conditions and ambient environmental matrices: river water and treated sewage effluent. As a model sampler we selected Empore SDB-RPS disks in a Chemcatcher housing. The disks were exposed for 1 to 8 days at flow rates between 0.03 and 0.4 m s(-1). Samples were analysed using a bioassay for estrogenic activity and by LC-MS-MS target analysis of the pharmaceuticals sulfamethoxazole, carbamazepine and clarithromycin. In order to assess sampling rates of SDB disks, we also measured aqueous concentrations of the pharmaceuticals. Sampling rates increased with increasing flow rate and this relationship was not affected by the environmental matrix. However, SDB disks were only sampling in the integrative mode at low flow rates <0.1 m s(-1) and/or for short sampling times. The duration of linear uptake was particularly short for sulfamethoxazole (1 day) and longer for clarithromycin (5 days). At 0.03 m s(-1) and 12-14 degrees C, the sampling rate of SDB disks was 0.09 L day(-1) for clarithromycin, 0.14 L day(-1) for sulfamethoxazole and 0.25 L day(-1) for carbamazepine. The results show that under controlled conditions, SDB disks can be effectively used as passive sampling devices.  相似文献   

10.
This project has arisen from the need to produce GFFs (glass fiber filters) bearing a thin and evenly distributed coating of a selected reagent in the equatorial plane for breakthrough studies. However, it has been discovered that today's two general techniques for coating GFFs (total immersion and application of reagent solution to GFFs) have usually produced unevenly distributed coatings of reagent in the equatorial plane. In addition, quantities of reagent on GFFs from commercial sources may vary widely in the same lot of coated GFFs. Consequences are variability in capacity of coated filters at the point of breakthrough and, perhaps, wasted reagent. Although today's reagent-coated filters may be satisfactory for routine air sampling, such filters may be unacceptable for precise breakthrough studies. Research has been conducted successfully to produce nearly evenly distributed coatings of reagents in the equatorial plane of GFFs by application of reagent solutions to the centers of GFFs which are resting on crisscrossing, fine, stainless-steel wire. Distributions of coatings have been determined by punching out twenty-one 5-mm circles from each GFF and analyzing each circle by flow-injection with a UV detector. Lowest achievable relative standard deviations of measurement (RSDs) for reagents in 5-mm circles have been 5 to 7%. Reagents studied have included 1-(2-pyridyl)piperazine (1-2PP), 2,4-dinitrophenylhydrazine (DNPH), and 1-(9-anthracenylmethyl)piperazine (MAP). Factors affecting the distribution of such coatings include choice of reagent and choice of solvent for the reagent solution.  相似文献   

11.
In this study, glycerol was tested as a collection substrate for passive bioaerosol sampling. Filters (mixed cellulose acetate and nitrate) were soaked in glycerol and exposed for an aerosol from three different fungal species: Penicillum commune, Aspergillus versicolor and Paecilomyces variotii. The passive sampling method was compared with a closed-face polycarbonate filter sampling method. Exposure was performed in an exposure chamber. The total number of spores was determined by microscopic techniques, and the cultivable number was determined by cultivation on Malt Extract Agar dishes. The glycerol soaked filter demonstrated a good correlation with the closed-face sampler with regard to the total count. Spores stored in a pumped filter cassette were not affected by storage for up to 7 days. On the other hand, the culturability of the spores was markedly decreased after 1 day when stored on glycerol soaked filters.  相似文献   

12.
Personal and area air samples were taken at a scrap lead smelter operation in a bullet manufacturing facility. Samples were taken using the 37-mm styrene-acrylonitrile closed-face filter cassette (CFC, the current US standard device for lead sampling), the 37-mm GSP or "cone" sampler, the 25-mm Institute of Occupational Medicine (IOM) inhalable sampler, and the 25-mm Button sampler (developed at the University of Cincinnati). Polyvinylchloride filters were used for sampling. The filters were pre- and post-weighed, and analyzed for lead content using a field-portable X-ray fluorescence (XRF) analyzer. The filters were then extracted with dilute nitric acid in an ultrasonic extraction bath and the solutions were analyzed by inductively coupled plasma optical emission spectroscopy. The 25-mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37-mm filters. The single reading from the 25-mm filters was adjusted for the nominal area of the filter to obtain the mass loading, while the three readings from the 37-mm filters were inserted into two different algorithms for calculating the mass loadings, and the algorithms were compared. The IOM sampler was designed for material collected in the body of the sampler to be part of the collected sample as well as that on the filter. Therefore, the IOM sampler cassettes were rinsed separately to determine if wall-loss corrections were necessary. All four samplers gave very good correlations between the two analytical methods above the limit of detection of the XRF procedure. The limit of detection for the 25-mm filters (5 microg) was lower than for the 37-mm filters (10 microg). The percentage of XRF results that were within 25% of the corresponding ICP results was evaluated. In addition, the bias from linear regression was estimated. Linear regression for the Button sampler and the IOM sampler using single readings and the GSP using all tested techniques for total filter loading gave acceptable XRF readings at loadings equivalent to sampling at the OSHA 8-hour Action Level and Permissible Exposure Limit. However, the CFC only had acceptable results when the center reading corrected for filter area was used, which was surprising, and may be a result of a limited data set. In addition to linear regression, simple estimation of bias indicated reasonable agreements between XRF and ICP results for single XRF readings on the Button sampler filters, (82% of the individual results within criterion), and on the IOM sampler filters (77% or 61%--see text), and on the GSP sampler filters using the OSHA algorithm (78%). As a result of this pilot project, all three samplers were considered suitable for inclusion in further field research studies.  相似文献   

13.
Exposure to perchlorethylene, especially for dry cleaning workers and for people living near dry cleaning shops, could lead to several diseases and disorders. This study examines the value of solid-phase microextraction (SPME) for sampling perchlorethylene in the atmosphere of dry cleaning shops. Carboxen/polydimethylsiloxane (CAR/PDMS) in 0.5-cm retracted mode was selected. There were no significant differences between sampling rates at different temperatures (range of 20 to 30 °C) and air velocities (2 to 50 cm/s). On the opposite, relative humidity (RH) had a significant effect on sampling rates. Method reproducibility was realized in the laboratory and field conditions and was 6.2 % and 7 to 11 %, respectively. Repeatability was also determined as 8.9 %. Comparison of the results according to the American Industrial Hygiene Association exposure assessment strategy showed the SPME sampler yields more conservative results in comparison with traditional standard method.  相似文献   

14.
The effects of relative humidity (40-90% RH) and varying glutaraldehyde vapour concentrations (< 0.1 ppm) on the response of an electrochemical fuel cell sensor have been investigated over time (0-400 s). These studies have identified changes in the response of the fuel cell with time after sampling. In particular, it has been found that the maximum cell output for water vapour occurs ca. 10 s after sampling whilst the response to glutaraldehyde occurs much later (> 100 s). For mixtures containing different ratios of water and glutaraldehyde vapours, the time taken to reach maximum fuel cell response varies between 10 and 100 s, depending on the ratio of the two vapours. For instance, glutaraldehyde vapour containing higher % RH has been found to result in shorter times to reach maximum fuel cell response. A comparison was made between measuring glutaraldehyde vapour concentrations in the presence of water vapour at the maximum fuel cell response and also at a fixed interval (240 s) after sampling. Such a comparison resulted in a reduction in the standard error from 36% to 5% for a glutaraldehyde vapour sample (0.023 ppm) measured at different values of relative humidity (40 to 80%). Examination of the effect of the sample volume (30-60 ml) on the response of the fuel cell shows, as expected, an approximate doubling of the fuel cell response. Optimisation of the fuel cell measurement parameters to measure a 60 ml sample leads to a lowering of the limit of detection from 0.083 ppm (for data taken at the maximum cell response) to 0.017 ppm for data measured 240 s after sampling. In the light of recent reductions in the legal limits for exposure to glutaraldehyde, this has important implications for the measurement of glutaraldehyde vapour in the workplace.  相似文献   

15.
Whatman No. 1 filters impregnated with a 3% solution of oxalic acid in ethanol which are used for elimination of ammonia from the air stream before entering the absorber for collecting SO2, were tested for a possible application (a) in the spectrophotometric determination of ammonia with Nessler's reagent and (b) in the reflectometric determination of smoke. It was shown that impregnated filters were as suitable for the determination of ammonia as absorbing solution and as applicable for smoke measurement as untreated filters. Further, the advantage of using impregnated filters for sampling ammonia lies in avoiding the interference of organic vapours which may occur, if absorbing solution is used.  相似文献   

16.
Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter(-1), with three different filter loadings denoted "Low", "Medium" and "High". Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter(-1). Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study.  相似文献   

17.
A new method utilizing the diffusive sampling of formaldehyde in air has been developed. Formaldehyde is sampled with the use of a glass fiber filter impregnated with N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH) and phosphoric acid. The formaldehyde hydrazone formed is desorbed from the filter with acetonitrile and determined by high-performance liquid chromatography (HPLC) with UV/visible detection at 474 nm. The sampling rate was determined to be 24.7 mL min-1 with a relative standard deviation of 7% for 48 experiments. The measured sampling rates were not dependent on the formaldehyde concentration (0.1-1.0 mg m-3), sampling time (15-482 min) or relative humidity (20-85%). The detection limit was 70 micrograms m-3 for a 15 min sampling period and 2 micrograms m-3 for an 8 h sampling period.  相似文献   

18.
A diffusive sampler for NO2, Willems badge, was validated in laboratory experiments and field tests. The collecting reagent for NO2 in the sampler is triethanolamine, and the analysis is based on a modified colorimetric method, the Saltzman method. The analysis was performed by a flow injection analysis (FIA) technique. The sampling rate for the sampler was determined to be 40.0 ml min-1. There was no effect of NO2 concentration or relative humidity on sampling rate, and the influence of sampling time was found to be small. The detection limit was 4 micrograms m-3 for a 24 h sample. The capacity is high enough to allow sampling of 150 micrograms m-3 for 7 days, which is twice the recommended Swedish short-term (24 h) guideline value as a 98-percentile over 6 months. In field tests, the sampler performed well, even at wind speeds higher than 2 m s-1, and at low temperatures. The overall uncertainty of the method was 24%. The sensitivity and capacity of the method also make it suitable for personal sampling for 2-8 h in working environments.  相似文献   

19.
Airborne lubricant emissions are a serious health hazard for employees in the metal working industry. The basic components of lubricants are oils and additives for adapting the properties to achieve the process demands. The oils used in lubricants are either mineral, synthetic or of biological origin. The lubricants are used as water-emulsions and also as straight oils. Extreme process conditions cause considerable amounts of aerosol and vapour emissions of lubricants into the working environment. Fibre filters are used in industrial demisters for pollution control and also for sampling purposes. Re-evaporation of separated lubricants from loaded fibre filters causes increased vapour emissions. Quantification of lubricant vapour emission was the subject of this research. An apparatus and an appropriate procedure for measuring the dynamic behaviour of evaporative losses from fibre filters were developed. The test piece of a loaded fibre filter was fixed in a sampling probe according to VDI 2066. The vapour concentration of organic compounds in downstream air was measured in real-time by using a photo-ionisation detector (PID). The PID was checked by sampling the vapour on an oleophilic adsorbent resin, solvent extraction and quantitative IR analysis and also gravimetrically. The two basic processes of filtering volatile aerosols are, on the one hand, collecting droplets on the fibres and, on the other hand, the evaporation of collected liquid. These two processes had to be separated in order to measure the increase of the vapour concentration caused by the tested fibre filter. The experiments were carried out using pure dodecane and hexadecane in order to avoid difficulties due to the unknown chemical composition of lubricant vapour. The variation of the air flow and the initial liquid mass on the filter covered the relevant range for industrial fibre demisters and for sampling methods based on collecting aerosols on fibre filters. It was found that the downstream air was saturated with lubricant vapour for a wide range of filter loads and filtration velocities. From the results obtained it can be concluded that loaded industrial filter systems emit air with saturation vapour concentration throughout their operation. Hence, vapour emissions can be estimated easily if the saturation vapour pressure and the mean relative molecular mass are known. Moreover, results obtained from measurements of filters with low loads confirm that the phase transition from liquid to vapour is influenced by the identified process parameters. This is relevant for measurement methods using fibre filters for sampling volatile aerosols. A semi-empirical model to estimate the evaporative losses for low loadings is proposed. However, further research is necessary to determine the full range of parameters that are relevant for evaporative losses from filters loaded with low masses of aerosols.  相似文献   

20.
Occupational exposures to isocyanates can lead to occupational asthma. Once sensitized, some workers could react to isocyanate monomers at concentrations below 1% of the Permissible Exposure Limit of 5 ppb in air. Currently available methods are not sufficiently sensitive to adequately evaluate isocyanates present at these levels in workplace air. This article describes a novel method for isocyanate determination allowing the ultratrace quantification in workplace air of hexamethylene diisocyanate, 2,4-toluene diisocyanate and 2,6-toluene diisocyanate monomers. Sampling is performed during a complete workshift at a flow rate of 1 L min(-1) with a cassette containing a 1-(2-methoxyphenyl)piperazine-impregnated 25 mm filter. Analysis is performed using liquid chromatography hyphenated with coordination ionspray tandem mass spectrometry. The analytical method's linearity was measured for a concentration range varying from the limit of detection of 0.04-0.13 ng mL(-1), depending on the monomer, up to approximately 32 ng mL(-1) for every isocyanate monomer, all with correlation coefficients (R(2)) greater than 0.999. The analytical method's lower limit of quantification combined with an adapted sampling strategy allow the quantification of isocyanate monomers down to 0.04 ppt for an 8 h work shift when a lithium adduct is used, which is more than 300 times lower than the most sensitive method currently available. This novel method can be used to confirm the very low level of isocyanate monomers for the safe reassignment of sensitized workers and it is also useful for charting the isocyanate dispersion tail in workplace environments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号