首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Theoretical calculations and experimental measurements show that the collection of small aerosol particles (0.05 to 5 micron diameter range) by water droplets in spray scrubbers can be substantially increased by electrostatically charging the droplets and particles to opposite polarity. Measurements with a 140 acfm two chamber spray scrubber (7 seconds gas residence time) showed an increase in the overall particle collection efficiency from 68.8% tit uncharged conditions to 93.6% at charged conditions, with a dioctyl phthalate aerosol (1.05 μm particle mass mean diameter and 2.59 geometric standard deviation). The collection efficiency for 0.3 μm particles increased from 35 to 87% when charged. During 1973–1974 a 1000 acfm pilot plant electrostatic scrubber was constructed inside a 40 ft trailer for evaluation on controlling particu-late emissions from pulp mill operations (funded by Northwest Pulp and Paper Association). Field tests performed on the particle emissions exhausting from SO2 absorption towers treating the gases from a magnesium based sulfite recovery boiler have shown particle collection efficiencies ranging from about 60 to 99% by weight, depending on the electrostatic scrubber operating conditions. Energy requirements for the University of Washington electrostatic scrubber are about 0.5 hp/1000 acfm (350 Watts/1000 acfm) including gas pressure drop, water pressure drop, and electrostatic charging of the water spray droplets and the particles.  相似文献   

2.
The prototype charged fog generator described in a preceding paper1 was field tested on a fugitive emission source at a bentonite ore processing plant in Worland, Wyoming, during 1981. Participate matter samples were collected as fine and coarse fractions under three different test scenarios: with no control, with partial control (uncharged fog), and with full control (charged fog). Measured particulate matter sample concentrations were normalized for each test day with respect to the background values so that particle control efficiency of the device could be evaluated without any bias during the entire test program.

These tests have shown that mean value of the inhalable particle control efficiency of charged fog measured under all instrument settings and field conditions is increased by 78% when compared with uncharged fog. In particular, fine particle control efficiencies of over 90% were recorded under optimum instrument settings and ideal field conditions. The bentonite particles seemed to carry a net positive charge. The optimum instrument settings were found to be: 60 L/h water flow rate, an applied voltage of 10-15 kV and a spray pattern which covers maximum volume of dust-laden air. Ideal field conditions are high relative humidity and calm or low winds.

Charged fog technology appears to be an effective and economically feasible method to control sources of fugitive particle emission in the inhalable size range. Further research is needed to evaluate the inhalable particle control efficiency of the device for emissions of various chemical compositions.  相似文献   

3.
Abstract

An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1 μm, the removal efficiency is greater than 80–90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is ~15.4 ± 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 μm.  相似文献   

4.
A turbulent wet scrubber was designed and developed to scrub particulate matter (PM) at micrometer and submicrometer levels from the effluent gas stream of an industrial coal furnace. Experiments were conducted to estimate the particle removal efficiency of the turbulent scrubber with different gas flow rates and liquid heads above the nozzle. Particles larger than 1 µm were removed very efficiently, at nearly 100%, depending upon the flow rate, the concentration of the dust-laden air stream, and the water level in the reservoir. Particles smaller than 1 µm were also removed to a greater extent at higher gas flow rates and for greater liquid heads. Pressure-drop studies were also carried out to estimate the energy consumed by the scrubber for the entire range of particle sizes distributed in the carrier gas. A maximum pressure drop of 217 mm H2O was observed for a liquid head of 36 cm and a gas flow rate of 7 m3/min. The number of transfer units (NTU) analysis for the efficiencies achieved by the turbulent scrubber over the range of particles also reveals that the contacting power achieved by the scrubber is better except for smaller particles. The turbulent scrubber is more competent for scrubbing particulate matter, in particular PM2.5, than other higher energy or conventional scrubbers, and is comparable to other wet scrubbers of its kind for the amount of energy spent.

Implications: The evaluation of the turbulent scrubber is done to add a novel scrubber in the list of wet scrubbers for industrial applications, yet simple in design, easy to operate, with better compactness, and with high efficiencies at lower energy consumption. Hence the turbulent scrubber can be used to combat particulate from industrial gaseous effluents and also has a scope to absorb gaseous pollutants if the gases are soluble in the medium used for particles capture.  相似文献   

5.
Electrolyzed water (EW) is an effective disinfectant with a wide range of pH. EW in acid range was proved to be an ammonia absorbent which make it valuable for wet scrubbers used in animal feeding operations (AFOs). This study aimed to optimize the design and operating parameters of a wet scrubber with EW spray for ammonia removal, based on the size distribution of droplets, the property of EW and the reduction efficiency of ammonia. The optimized parameters included droplet size, nozzle flow rates, pH and available chlorine concentration (ACC) of EW, nozzle number at single stage, stage number, initial ammonia concentration and air speed in the duct. The ammonia removal efficiency increased with the decrease of droplet size and the increase of flow rate. The pH values of EW showed significant influence on ammonia removal efficiency (P ? 0.05), while ACC of the EW showed no significant influence (P > 0.05). For inlet ammonia concentration of 70 ppm with one and three spray stages, the wet scrubber with EW (pH = 1.35) spray was able to reduce 55.8 ± 4.3 % and 97.2 ± 3.0 % of ammonia, respectively, when the nozzles with 0.9 mm orifice diameter operated at a flow rate of 1.20 L min-1. Response surface analysis showed that orifice diameter, nozzle flow rate, and their combination were all significant factors impacting ammonia removal efficiency for both pH =1.35 and 5.50 at a 95% confidence level. Optimal ammonia removal efficiency was obtained at orifice diameter 0.9 mm and flow rate 1.20 L min-1 within the selected range. The results of this study demonstrated that wet scrubber with EW spray could be a very effective and feasible ammonia mitigation technology for animal feeding operation.

Implications: It is difficult to effectively reduce ammonia emitted from the animal feeding operations (AFOs). Both the acidity and disinfection effects of electrolyzed water (EW) make it a potential absorbent used for spray in wet scrubber to reduce the ammonia and microorganisms. Based on some preliminary field test results, lab tests were conducted to optimize the design and operation parameters of a wet scrubber with EW spray to improve the ammonia removal efficiency. A better understanding of the application and influence factors of the wet scrubber with EW spray can contribute to effective mitigation of ammonia emission from animal houses and improve the atmosphere air quality.  相似文献   


6.
The overall particle collection efficiencies of spray scrubbers using monodisperse droplets of 100,500, and 1000 microns diameter were calculated for the cases of evaporating and condensing droplets. The properties of the gas at the inlet to the spray scrubber were maintained constant at 150°F, 100% relative humidity, and 1 atmosphere pressure. At the liquid entrance to the spray scrubber, the water droplet temperature was 50° F for the condensing case and 180° F for the evaporating case. The liquid to gas flow rate ratio for all the calculations was held constant at 4 gal/1000 acf. The gas velocity in the co-current spray tower was 1 ft/sec in the downwind direction. The calculation results show that for the particles in the 0.01 to 10 Mm diameter range, the overall spray scrubber particle collection efficiency is greater with the cooler 50°F water (condensing case) than with the warmer 180°F water (evaporating case). The effect of diffusiophoresis and thermophoresis is noticeable for all the water droplet sizes considered, but is more significant for the larger water droplets. This greater effect for the larger water droplets compared to the smaller droplets is due to the longer existence of the temperature and water vapor concentration gradients between the water droplets and the surrounding gas.  相似文献   

7.
介绍了无泵水幕废气净化器的工作原理和运行特点,采用该设备处理某金刚石公司的酸洗车间高浓度的NOx气体,其净化效率达90%以上,净化后的NOx气体可直接达标排放.无泵水幕废气净化器解决了传统的水喷淋塔普遍存在的喷嘴堵塞、单级净化效率低、运行费用高等问题,在高浓度酸性气体治理方面具有很好的推广应用前景.  相似文献   

8.
A large number of pressurized coal gasification processes being developed propose to use venturi scrubbers for particulate removal at high pressures. Theoretical predictions based on venturi scrubber performance models indicate that particle collection efficiency will decrease severely in these high gas pressure applications.

An exploratory theoretical and experimental program was performed to study the effect of gas pressure on venturi scrubber performance. Experiments were done on a 0.47 m3/s (1000 acfm) pilot scale venturi scrubber. Particle collection performance was determined as a function of scrubber pressure drop for venturi scrubbers operating In the range of 1-10 atm total pressure. Experimental results confirmed that the particle collection efficiency of venturi scrubbers decreases for a given scrubber pressure drop as total gas pressure Is increased. To achieve the same particle collection efficiency, the pressure drop across a venturi scrubber operated at 10 atm Is about 10 times that of the same scrubber operated at 1 atm pressure.  相似文献   

9.
Collection efficiencies are shown for control of fine particles in venturi scrubbers (1) as a function of pressure drop, and (2) as a function of throat area and liquid to gas ratio. A relationship of pressure drop to throat area, gas density, throat velocity, and liquid to gas ratio is given and is used to provide a method for estimating efficiency knowing only these scrubber design parameters. The effect of charged particles and of surface active agents on collection efficiency are discussed briefly.  相似文献   

10.
The purpose of this paper on industrial plan evaluation is twofold: to present tools which can be used to evaluate quantitatively certain aspects of air pollution control devices, and to point up specifically two areas in which research is urgently needed. These research areas are in removing solid particles after wetting in scrubbers and use of surface active agents in scrubbing gaseous pollutants. Therefore, the body of information presented is directed to engineers in the field of evaluating the air pollution potential of new industrial plants, to scientists involved in determining the parameters and effectiveness of control devices, and to research and development scientists in the field of surfactants.

One tool presented is a chart for measuring the effectiveness of incinerator afterburners and vapor incinerators. The required inputs to the chart are the rate of flue gas flow in standard cubic feet per minute and the auxiliary fuel burner capacity in Btu per hour. The chart yields the flue gas temperature increase which will result, given in degrees F. The second tool presented is a new psychrometric graph for the humidifying and cooling of gases from processes as hot as 3000°F. Inputs into the graph are the temperature of the gases entering the sprays from the hot process and the temperature desired before they enter a control device such as a fabric filter or a scrubber. The chart yield is the amount of water needed in gallons per thousand cubic feet of gas. The only calculation needed is a correction of the hot gas volume to 70°F. Water needed to saturate the gases can be read directly also.  相似文献   

11.
Significant amounts of volatile organic compounds and greenhouse gases are generated from wastewater lagoons and tailings ponds in Alberta, Canada. Accurate measurements of these air pollutants and greenhouse gases are needed to support management and regulatory decisions. A mobile platform was developed to measure air emissions from tailings pond in the oil sands region of Alberta. The mobile platform was tested in 2015 in a municipal wastewater treatment lagoon. With a flux chamber and a CO2/CH4 sensor on board, the mobile platform was able to measure CO2 and CH4 emissions over two days at two different locations in the pond. Flux emission rates of CO2 and CH4 that were measured over the study period suggest the presence of aerobic and anaerobic zones in the wastewater treatment lagoon. The study demonstrated the capabilities of the mobile platform in measuring fugitive air emissions and identified the potential for the applications in air and water quality monitoring programs.

Implications: The Mobile Platform demonstrated in this study has the ability to measure greenhouse gas (GHG) emissions from fugitive sources such as municipal wastewater lagoons. This technology can be used to measure emission fluxes from tailings ponds with better detection of spatial and temporal variations of fugitive emissions. Additional air and water sampling equipment could be added to the mobile platform for a broad range of air and water quality studies in the oil sands region of Alberta.  相似文献   


12.
This paper describes the evaluation of the performance of ESPs operating downstream of spray dryers in high- and medium-sulfur coal flue gas streams. Tests were conducted at the TV A10 MW Spray Dryer/ESP Pilot Plant and the EPRI High Sulfur Test Center. The results of the analysis of particle characteristics, spray dryer operating parameters, and ESP operating variables identify the occurrence of severe particle reentrainment due to the low resistivity (108 ohm-cm and lower) of the sorbent/flyash mixtures at low approach-tosaturation temperatures. The reentrainment has a significant impact on the collection efficiency of ESPs which could represent a fundamental limitation on their ability to adequately perform in this environment. Although this program has been focused on spray dryer applications, because of the similarities of the gas and particle characteristics produced from spray drying and other dry scrubbing processes, the results also have implications to duct slurry injection, dry sorbent injection with humidification, and processes involving furnace sorbent injection with humidification.

The performance characteristics of the ESPs are presented under both baseline and spray dryer conditions. The results are analyzed and the Southern Research Institute ESP Computer Model was used to evaluate the data. Special techniques for measuring particle resistivity at these conditions are described. A theoretical examination of particle reentrainment was undertaken which indicated that at low-resistivity levels the electrostatic forces reverse and tend to pull the particles off the plates with a force proportional to the square of the electric field. This repulsion of particles from the plates at spray dryer conditions was confirmed by laboratory experiments. Chloride content of the coal was found to be an important parameter effecting the performance of the ESP. Implications of the results of this evaluation relative to ESP upgrades are presented.  相似文献   

13.
An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1microm, the removal efficiency is greater than 80-90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is approximately 15.4 +/- 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 microm.  相似文献   

14.
Abstract

The promulgation of odor control rules, increasing public concerns, and U.S. Environmental Protection Agency (EPA) air regulations in nonattainment zones necessitates the remediation of a wide range of volatile organic compounds (VOCs) generated by the rendering industry. Currently, wet scrubbers with oxidizing chemicals are used to treat VOCs; however, little information is available on scrubber efficiency for many of the VOCs generated within the rendering process. Portable gas chromatography/mass spectrometry (GC/MS) units were used to rapidly identify key VOCs on-site in process streams at two poultry byproduct rendering plants. On-site analysis was found to be important, given the significant reduction in peak areas if samples were held for 24 hr before analysis. Major compounds consistently identified in the emissions from the plant included dimethyl disulfide, methanethiol, octane, hexanal, 2-methylbutanal, and 3-methylbutanal. The two branched aldehydes, 2-methylbutanal and 3-methylbutanal, were by far the most consistent, appearing in every sample and typically the largest fraction of the VOC mixture.

A chlorinated hydrocarbon, methanesulfonyl chloride, was identified in the outlet of a high-intensity wet scrubber, and several VOCs and chlorinated compounds were identified in the scrubbing solution, but not on a consistent basis. Total VOC concentrations in noncondensable gas streams ranged from 4 to 91 ppmv. At the two plants, the odor-causing compound methanethiol ranged from 25 to 33% and 9.6% of the total VOCs (v/v). In one plant, wet scrubber analysis using chlorine dioxide (ClO2) as the oxidizing agent indicated that close to 100% of the methanethiol was removed from the gas phase, but removal efficiencies ranged from 20 to 80% for the aldehydes and hydrocarbons and from 23 to 64% for total VOCs. In the second plant, conversion efficiencies were much lower in a packed-bed wet scrubber, with a measurable removal of only dimethyl sulfide (20–100%).  相似文献   

15.
From 1995 to 2004, in Genoa, Italy, daily concentrations of twelve polycyclic aromatic hydrocarbons (PAHs) were measured in particulate phase (PM10), around a coke oven plant in operation from the 1950s and closed in 2002. The study permitted to identify the coke oven as the main PAH source in Genoa, causing constant exceeding of benzo(a)pyrene (BaP) air quality target (1.0 ng/m3) in the urban area till 1,900 meters distance downwind the plant. For this reason the plant was closed. Distance and daily hours downwind the coke plant were the main sources of variability of toxic BaP equivalent (BaPeq) concentrations and equations that best fitted these variables were experimentally obtained. During full plant activity, annual average BaPeq concentrations, measured in the three sampling sites aligned downwind to the summer prevalent winds, were: 85 ng/m3 at 40 m (site 2, industrial area), 13.2 ng/m3 at 300 m (site 3, residential area) and 5.6 ng/m3 at 575 m (site 4, residential area).

Soon after the coke oven's closure (February 2002) BaPeq concentrations (annual average) measured in residential area, decreased drastically: 0.2 ng/m3 at site 3, 0.4 ng/m3 at site 4. Comparing 1998 and 2003 data, BaPeq concentrations decreased 97.6% in site 3 and 92.8% in site 4.

Samples collected at site 3, during the longest downwind conditions, provided a reliable PAH profile of fugitive coke oven emissions. This profile was significantly different from the PAH profile, contemporary found at site 5, near the traffic flow.

This study demonstrates that risk assessment based only on distance of residences from a coke plant can be heavily inaccurate and confirmed that seasonal variability of BaPeq concentrations and high variability of fugitive emissions of PAHs during coke oven activities require at least one year of frequent and constant monitoring (10-15 samples each month).

Implications: Around a coking plant, polycyclic aromatic hydrocarbons (PAHs), concentrations depend mainly on downwind hours and distance. Equations that best fit these variables were experimentally calculated. Fugitive emissions of an old coke oven did not comply with the threshold BAP air concentration proposed by the World Health Organization (WHO), up to 1,900 m distance. The study identified the PAH profile of fugitive emissions of a coke oven, statistically different from the profile of traffic emissions. During its activity, in the Genoa residential area, 575 m away from the plant, 92.8% of found PAHs was due to coke oven emission only.  相似文献   

16.
Airborne microorganisms, especially the pathogenic microorganisms, emitted from animal feeding operations (AFOs) may harm the environment and public health and threaten the biosecurity of the farm and surrounding environment. Electrolyzed water (EW), which was considered to be an environmentally friendly disinfectant, may be a potential spraying medium of wet scrubber for airborne microorganism emission reduction. A laboratory test was conducted to investigate the airborne bacteria (CB) removal efficiency of the wet scrubber by EW spray with different designs and operating parameters. Both the available choline (AC) initial loss rate and AC traveling loss rate of acidic electrolyzed water (AEW; pH = 1.35) were much higher than those of slightly acidic electrolyzed water (SAEW; pH = 5.50). Using one spraying stage with 4 m sec?1 air speed in the duct, the no detect lines (NDLs) of SAEW (pH = 5.50) for airborne Escherichia coli, Staphylococcus aureus, and Salmonella enteritidis removal were all 50 mg L?1, whereas the NDLs of AEW (pH = 1.35) for airborne E. coli, S. aureus, and S. enteritidis removal increased to 70, 90, and 90 mg L?1, respectively. The NDLs of SAEW (pH = 5.50) for airborne E. coli, S. aureus, and S. enteritidis were lower than those of AEW (pH = 1.35) at single spraying stage. Increase in the number of stages lowered the NDLs of both SAEW (pH = 5.50) and AEW (pH = 1.35) for airborne E. coli, S. aureus, and S. enteritidis. EW with a higher available chlorine concentration (ACC) was needed at air speed of 6 m sec?1 to reach the same airborne CB removal efficiency as that at air speed of 4 m sec?1. The results of this study demonstrated that EW spray wet scrubbers could be a very effective and feasible airborne CB mitigation technology for AFOs.

Implications: It is difficult to effectively reduce airborne bacteria emitted from animal feeding operations (AFOs). Electrolyzed water (EW) with disinfection effect and acidity is a potential absorbent for spray in wet scrubber to remove microorganisms and ammonia. Based on the field test results, a laboratory experiment we conducted this time was to optimize the design and operation parameters to improve the airborne bacteria removal efficiency. A better understanding of the EW application in the wet scrubber can contribute to the mitigation of airborne bacteria from animal houses and improve the atmosphere air quality.  相似文献   


17.
Comparative gas cleaning performance of a pilot-scale venturi scrubber with throat dimensions of 6 in. wide × 1 2 in. long × 1 2 in. deep was obtained for the following three methods of water injection: a system of spray nozzles located along each short side of the throat (Figure 2a); a continuous slot located immediately above the nozzles, along each short side of the throat (Figure 2b); and a weir located 2 ft above the spray nozzles along long side of the throat (Figure 2c). For each method of water injection the gas cleaning performance, as a function of the pressure drop, was measured by two tests: absorption of SO2 and collection efficiency for particles of methylene blue of controlled size.  相似文献   

18.
The term “wet scrubber” or simply “scrubber,” for the purpose of this report, is intended to include any device using liquid to effect the removal of solid or liquid particles which are entrained in process air or gas streams. This guide is intended to provide information required for the selection and performance evaluation of all types of scrubbers installed for the primary purpose of removing such particulates from any process gas stream. It is not intended to cover scrubbers for the collection of gaseous and/or vapor constituents which involve gas absorption mechanisms.  相似文献   

19.
With increasing attention on sulfuric acid emission, investigations on the removal characteristics of sulfuric acid aerosols by the limestone gypsum wet flue gas desulfurization (WFGD) system and the wet electrostatic precipitator (WESP) were carried out in two coal-fired power plants, and the effects of the WFGD scrubber type and the flue gas characteristics were discussed. The results showed that it was necessary to install the WESP device after desulfurization, as the WFGD system was inefficient to remove sulfuric acid aerosols from the flue gas. The removal efficiency of sulfuric acid aerosols in the WFGD system with double scrubbers ranged from 50% to 65%, which was higher than that with a single scrubber, ranging from 30% to 40%. Furthermore, the removal efficiency of WESP on the sulfuric acid aerosols was from 47.9% to 52.4%. With increased concentrations of SO3 and particles in the flue gas, the removal efficiencies of the WFGD and the WESP on the sulfuric acid aerosols were increased.

Implications: Investigations on removal of sulfuric acid aerosols by the WFGD and the WESP in the power plants were aimed at the control of sulfuric acid emission. The results showed that the improvement of the WFGD system was beneficial for the reduction of sulfuric acid emission, while the WESP system was essential to control the final sulfuric acid aerosol concentration.  相似文献   


20.
Compliance with sulfur oxides standards will in many cases result in the installation of scrubbing devices. If these devices operate on an effluent gas stream containing particulate as well as sulfur oxides, simultaneous removal would be expected. Since effective simultaneous removal of particulate matter and sulfur oxides is economically desirable, it is of considerable import to characterize scrubber designs being considered as sulfur oxide absorbers as particulate control devices; especially, for fine particulate control.

Data on the fine particle collection efficiency of sulfur oxides scrubbers at two power generating stations is presented. At the first, a venturi and a turbulent contacting absorber (TCA) both with capacities of 30,000 cfm were tested. At the second, a venturi with 600,000 scfm capacity was tested. Fine particle collection efficiency was determined at three pressure drops for the TCA using a cascade impactor. Results for the TCA show high removal efficiencies. It collected more than 90% of submicron particles when the pressure drop was nearly 10 in. H20. The overall particulate removal in the TCA scrubber as determined by modified method 5 or by Brink impactor was greater than 99% when the pressure drop was greater than 6 in. H20. For both the venturi scrubber at the Shawnee Steam Plant and that at the Mystic Power Station, the collection efficiency decreased rapidly with decreasing particle size in the fine particle region.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号