首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 250 毫秒
1.
针对养猪废水厌氧消化液高ρ(NH4+-N)的特点,构建了上层填充沸石强化硝化、下层填充砖渣强化反硝化的功能分区型人工湿地,考察其启动阶段运行性能、硝化区及反硝化区污染物去除性能. 结果表明,湿地以间歇方式运行(饱和液位无变化),启动后NO3--N的产生速率为0.014 6 kg/(m3·d),湿地底部出水的ρ(NO3--N)平均值为14.94 mg/L,明显低于沸石层的21.77 mg/L. CODCr主要在湿地上层硝化区被去除,平均去除率为64.82%. 随着湿地启动,下层由于反硝化作用消耗的有机物增至56.67 mg/L. 在进水期的前15 min,CODCr、NH4+-N、TP的去除率最大,NO3--N溶出量(以ρ计)最高,达42.30 mg/L. 沸石层10、20和30 cm处硝化速率基本稳定,沸石层的Eh均在400 mV以上. 与间歇方式相比,湿地以潮汐流方式(进水期与落干期时间比为1 h∶23 h)运行时,CODCr和TN去除率分别由78.45%和41.99%升至82.62%和53.41%. 研究显示,功能分区型人工湿地通过上层硝化、下层反硝化方式可有效去除养殖废水厌氧消化液中的NH4+-N.   相似文献   

2.
人工湿地微生物硝化和反硝化强度对比研究   总被引:31,自引:0,他引:31  
通过对表面流和潜流人工湿地中不同填料层的微生物硝化和反硝化强度进行对比研究,探讨了人工湿地脱氮过程中硝化反硝化作用的变化,从微生物角度分析了人工湿地脱氮效果的差别.研究结果表明,人工湿地系统可以同时进行硝化和反硝化作用.表面流湿地硝化强度高于潜流湿地,2个系统中的硝化强度具有较明显的分层现象,上层硝化强度高于下层.2个系统中沿程硝化强度呈递减趋势,硝化强度反映氨氮去除率的大小,表面流湿地氨氮的去除率高于芦苇潜流湿地30%~40%.反硝化强度比较结果表明,潜流湿地上层土壤填料的反硝化强度最高,砾石填料反硝化强度最低,表面流湿地反硝化强度居中,2个系统反硝化强度上下分层不明显,沿程基本保持不变.  相似文献   

3.
强化启动对内循环生物流化床硝化效果的影响   总被引:1,自引:0,他引:1       下载免费PDF全文
通过改变内循环生物流化床的启动水质,提高N/C组成以强化流化床后期的硝化作用.结果表明,高N/C和低进水COD强化启动后处理生活污水,在HRT为2h时,可以同时高效去除COD和氨氮,氨氮的平均去除率为74%.耗氧速率试验表明,强化启动后,流化床中生物膜的异养菌活性大幅度降低,氨氧化细菌活性明显提高,硝化细菌活性变化不大.对反应系统微生物醌进行的跟踪分析表明,强化启动后,生物膜中的硝化细菌数量明显增加,微生物种群的分布均匀性变化较小,以革兰氏阴性菌为主.扫描电镜观察显示,低N/C启动条件下,生物膜厚且致密,异养菌所占比例高;高N/C启动条件有利于硝化细菌的生长,生物膜相对稀薄.  相似文献   

4.
碳氮比对聚氨酯生物膜反应器短程硝化反硝化的影响   总被引:4,自引:3,他引:1  
谭冲  刘颖杰  王薇  邱珊  马放 《环境科学》2014,35(10):3807-3813
研究了聚氨酯生物膜反应器在短程硝化反硝化工艺中的应用,考察碳氮比(15∶1、10∶1、5∶1和1.8∶1)对聚氨酯脱氮系统脱氮性能和微生物群落结构的影响,以及微生物群落结构与其处理效果的对应关系.结果表明,经过100 d的运行,当进水碳氮比从15依次下降到10、5和1.8,亚硝酸氮累积率由56.1%逐次上升到62.3%、72.3%和83.2%.在进水碳氮比为10时,系统取得最佳处理效果,氨氮和总氮去除率分别为99.1%和91.0%.进水碳氮比在15、10、5和1.8时,硝化反应和反硝化反应均同时发生在聚氨酯生物膜系统内,随着进水碳氮比的降低,同时硝化反硝化效率逐渐降低.生物膜的功能微生物分析表明,在碳氮比15时,生物膜的微生物多样性要显著高于其他工况.生物膜上的优势亚硝酸菌和硝酸菌分别以亚硝化单胞菌(Nitrosospira sp.)和硝化螺旋菌(Nitrospira sp.)为主,而反硝化细菌则以假单胞菌(Pseudomonas sp.)占据优势.  相似文献   

5.
移动床膜生物反应器同步硝化反硝化特性   总被引:11,自引:3,他引:8  
杨帅  杨凤林  付志敏 《环境科学》2009,30(3):803-808
采用挂膜填料代替传统膜生物反应器(MBR)的活性污泥,构建一种新型的移动床膜生物反应器 (MBMBR),考察其处理模拟生活污水的效果及同步硝化反硝化(SND)特性.结果表明,移动床膜生物反应器运行67 d,对模拟生活污水表现出良好的去除有机物及同步硝化反硝化能力.进水COD浓度为573.5~997.7 mg/L时,膜出水COD去除率为88.3%~99.2%.进水氨氮浓度为45.5~99.2 mg/L时,膜出水氨氮去除率为72.1%~99.8%,总氮去除率为62.0%~96.3%.批式实验结果表明,生物膜去除总氮的最佳溶解氧浓度为1 mg/L,其中氨氮和总氮去除率分别为100%和60%.生物膜系统内可能存在好氧反硝化现象.DO为3 mg/L且有机碳源充足时,生物膜总氮去除率为99.0%,SND率达到99.8%.扫描电镜对生物膜的观察发现生物膜内部存在着明显的孔隙,有利于溶解氧和有机基质从外界向生物膜内部传递.  相似文献   

6.
炭膜曝气生物膜反应器硝化作用及其微生物群落结构分析   总被引:1,自引:0,他引:1  
采用炭膜曝气生物膜反应器处理无机含氮废水,通过改变进水氨氮浓度和水力停留时间,研究了反应器硝化性能、氧利用情况以及氨氮去除负荷,并对生物膜表面特性和硝化菌优势菌种进行分析.结果表明, 在膜内气压0.017 MPa,进水NH+4-N 50 mg/L,HRT为8 h条件下,NH+4-N去除率达到96%,出水NO-2-N平均为17 mg/L,一定程度上实现了短程硝化,炭膜所供给氧气被生物膜全部消耗;系统比表面氨氮最大去除速率为9.7 g/(m2·d),炭膜表面有限的生物量制约了去除速率的进一步提高; 荧光原位杂交技术分析揭示生物膜内亚硝化单胞菌(Nitrosomonas)和亚硝化螺菌(Nitrosospira)为亚硝化细菌优势菌种,分别占细菌总菌数的19%和21%,硝化螺菌(Nitrospira)为硝化细菌优势菌种,占总菌数的20%,未检测到硝化杆菌(Nitrobacter)的存在.  相似文献   

7.
沸石滤料曝气生物滤池处理水产养殖废水的工艺特性   总被引:8,自引:2,他引:6  
采用上流式沸石滤料曝气生物滤池(ZBAF)对水产养殖废水进行处理.结果表明,沸石的高效吸附作用可使系统获得快速启动,异养菌和硝化菌生物膜的成熟分别只需7d和25d;系统在水力负荷0.25m/h及气水比20∶1工艺条件下运行效能最佳,COD和NH+4-N去除率分别稳定在85%和70%左右.通过对ZBAF滤柱沿程水质、微生物等指标分析,异养菌和硝化菌主要聚居区分别在滤料层下端和上端,DO值的低谷位置可作为其聚居区分界线;生物量(磷脂-P)和生物活性(好氧速率)沿高程的分布大体一致,其最大值均出现在滤柱底部,分别为114.12 nmol/g和0.67 mg/(g.h).  相似文献   

8.
微气泡曝气生物膜反应器同步硝化反硝化研究   总被引:6,自引:5,他引:1  
刘春  年永嘉  张静  张明  张磊  龚鹏飞  肖太民  李星 《环境科学》2014,35(6):2230-2235
同步硝化反硝化(SND)是废水处理中的新型生物脱氮工艺,和传统生物脱氮工艺相比具有显著的应用优势.本研究采用微气泡曝气固定床生物膜反应器,研究了SND过程中污染物去除效果并检测了生物膜功能菌群的变化情况.结果表明,在微气泡曝气固定床生物膜反应器内可以实现同步硝化反硝化,通过提高进水COD负荷和C∶N比,降低溶解氧(DO)浓度,同时增加填料床层孔隙率,可以改善SND效果.当进水COD负荷和总氮(TN)负荷为0.86 kg·(m3·d)-1和0.10 kg·(m3·d)-1,且填料床层孔隙率为81%时,COD和TN的去除率分别为97.6%和70.2%,实现了COD和TN的同步高效去除;同时,微气泡曝气对氧传质的强化作用使得氧利用率高达91.8%.此外,生物膜活性和硝化及反硝化功能菌群的变化,与反应器COD、氨氮和TN去除能力的变化基本一致.  相似文献   

9.
好氧颗粒污泥膜生物反应器脱氮特性   总被引:4,自引:1,他引:3  
好氧颗粒污泥膜生物反应器(GMBR)连续运行71 d,对模拟生活污水表现出良好的有机物去除及同步硝化反硝化(SND)能力.进水TOC浓度为56.8~132.6mg/L时,膜出水TOC去除率为84.7%~91.9%;进水氨氮浓度为28.1~38.4mg/L时,稳定运行阶段氨氮去除率为85.4%~99.7%,总氮去除率为41.7%~78.4%.结合反应器中污泥生长形态,对不同粒径污泥的同步硝化反硝化研究表明,好氧条件下絮状污泥几乎没有反硝化能力,SND能力来源于颗粒污泥,并且随着污泥粒径的增大,反硝化速率以及总氮去除效率提高.通过扫描电镜对颗粒污泥外观以及沿传质方向剖面内部特征的观察分析,对颗粒污泥同步硝化反硝化的作用过程进行了探讨.  相似文献   

10.
SBR法去除有机物、硝化和反硝化过程中pH变化规律   总被引:9,自引:0,他引:9  
为实现SBR法脱氮在线模糊控制 ,以啤酒废水为研究对象 ,通过不同进水氨氮浓度和不同进水有机物浓度的试验 ,研究了SBR法去除有机物、硝化和反硝化过程中pH的变化规律。试验结果表明在有机物去除过程中pH呈现大幅上升的现象 ;有机物去除结束时pH停止上升 ,随着硝化反应的进行pH不断下降直至反应结束 ,然后pH突然快速上升或维持不变。在反硝化过程中 ,pH不断上升直至反硝化结束出现转折点 ,然后持续下降 ,指示反硝化已经结束。不同进水氨氮浓度和进水有机物浓度的试验进一步验证了pH特征点的重现性 ,可以作为SBR法去除有机物、硝化和反硝化的模糊控制参数  相似文献   

11.
张千  吉芳英  徐璇 《环境科学》2018,39(4):1763-1772
为解决现有低碳源污水处理工艺能耗高、工艺复杂和脱氮效果不佳等问题,提出一种新型的混凝沉淀/后置固相反硝化滤池工艺.为了从微生物角度来解释该工艺的宏观脱氮效果,采用聚合酶链式反应-变性梯度凝胶电泳(PCR-DGGE)技术研究了工艺中生物滤池沿程微生物群落结构的变化规律及脱氮功能菌的类型.结果表明,硝化滤池内生物膜中微生物的多样性和丰度沿上向流方向呈逐渐上升的趋势,且硝化细菌在顶端富集,而固相反硝化滤池呈先上升后下降的趋势,反硝化菌在中部富集.硝化滤池中的优势菌株为硝化细菌Nitrosomonas sp. Nm47和Candidatus Nitrospira defluvii;固相反硝化滤池中的优势菌株为反硝化菌Rubrivivas gelatinosus和固体碳源降解反硝化菌Myxobacteria.  相似文献   

12.
Since the ammonia in the effluent of the traditional water purification process could not meet the supply demand, the advanced treatment of a high concentration of NH4 +-N micro-polluted source water by biological activated carbon filter (BACF) was tested. The filter was operated in the downflow manner and the results showed that the removing rate of NH4 +-N was related to the influent concentration of NH4 +-N. Its removing rate could be higher than 95% when influent concentration was under 1.0 mg/L. It could also decrease with the increasing influent concentration when the NH4 +-N concentration was in the range from 1.5 to 4.9 mg/L and the dissolved oxygen (DO) in the influent was under 10 mg/L, and the minimum removing rate could be 30%. The key factor of restricting nitrification in BACF was the influent DO. When the influent NH4 +-N concentration was high, the DO in water was almost depleted entirely by the nitrifying and hetetrophic bacteria in the depth of 0.4 m filter and the filter layer was divided into aerobic and anoxic zones. The nitrification and degradation of organic matters existed in the aerobic zone, while the denitrification occurred in the anoxic zone. Due to the limited carbon source, the denitrification could not be carried out properly, which led to the accumulation of the denitrification intermediates such as NO2 . In addition to the denitrification bacteria, the nitrification and the heterotrophic bacteria existed in the anoxic zone. __________ Translated from Environmental Science, 2006, 27(1): 69–73 [译自: 环境科学]  相似文献   

13.
固定化细胞单级生物脱氮研究   总被引:18,自引:1,他引:17       下载免费PDF全文
利用硝化菌和反硝化菌混合固定的方法,研究了好氧条件下同时进行硝化和反硝化作用的单级生物脱氮技术.结果表明,反硝化菌被固定后,在好氧条件下仍具有反硝化功能.硝化菌和反硝化菌被混合固定后,可以在好氧条件下同时进行硝化和反硝化作用,并且其氨氧化速率约为硝化菌单独固定时的1.4倍.硝化菌和反硝化菌混合固定构成的单级生物脱氮系统其脱氮速率是分别固定构成的单级生物脱氮系统的2.6倍.  相似文献   

14.
本研究采用具有氨氮富集分离特性的阳离子交换膜-超滤(CEM-UF)组合膜与硝化/反硝化结合处理低C/N废水,考察该系统不同流量比下低C/N废水的硝化、反硝化脱氮特性,并通过对硝化、反硝化活性污泥进行16Sr DNA高通量测序,分析功能微生物群落结构特征.结果表明,系统进水TN为60 mg·L-1,COD/TN为2.65下,各流量比下硝化均有较好效果,平均氨氮去除率为98.7%,流量比值由1∶2上升到1∶6过程中,反硝化m(COD)/m(NO-3-N)随之升高,1∶6时平均硝氮去除率达到最高,为86.28%,系统总氮去除率由22.56%上升到46.8%.Illumina高通量测序结果表明,硝化污泥中可以固氮的Proteobacteria菌门占30.9%,重要的亚硝酸盐氧化菌Nitrospirae菌门占3.06%,属水平上检测到氨氧化菌(AOB)Nitrosomonas和Nitrosospira,亚硝酸盐氧化菌(NOB)Nitrospira和Nitrobacter,AOB与NOB菌比例较高,与硝化反应器中较好的硝化效果相一致.反硝化污泥中Proteobacteria菌门占主导地位(53.13%),其次是Bacteroidetes菌门(10.93%),在属的水平上检测到Dechloromonas、Thauera、Castellaniella、Alicycliphilus、Azospira、Comamonas、Caldilinea和Saccharibacteria多种具有反硝化脱氮作用的相关菌属,反硝化菌所占比例为25.91%,反硝化污泥中具有反硝化功能的微生物丰富,反硝化效果良好.  相似文献   

15.
羟胺抑制协同pH调控对人工快渗系统短程硝化的影响   总被引:4,自引:0,他引:4  
陈佼  张建强  文海燕  张青  杨旭  李佳 《环境科学学报》2016,36(10):3728-3735
针对人工快渗系统(CRI)总氮去除率低的问题,研究了羟胺抑制协同pH调控对人工快渗系统实现由全程硝化向短程硝化转化的可行性,探讨了其对系统内氮素污染物迁移转化和硝化功能菌空间分布及活性的影响.结果表明,0.5 mmol·L~(-1)羟胺连续添加13 d后可实现CRI系统短程硝化的快速启动,氨氮去除率、亚硝氮积累率分别为91.1%、77.9%,经16 d不添加羟胺运行后氨氮去除率、亚硝氮积累率分别降低3.9%、9.8%,此时调控进水pH至8.4,氨氮去除率和亚硝氮积累率均超过90%,CRI系统短程硝化效果显著且稳定性较高.羟胺对硝化菌具有选择性抑制,对AOB和NOB产生明显抑制的浓度分别为0.7、0.5 mmol·L~(-1),羟胺浓度为1.0 mmol·L~(-1)时AOB和NOB活性均被严重抑制且解抑较难;pH调控对短程硝化的影响主要与游离氨(FA)的抑制作用有关,对AOB和NOB产生明显抑制的FA浓度分别为26.5、5.6 mg·L~(-1),NOB比AOB对FA的敏感性更高.  相似文献   

16.
碱度对沸石序批式反应器亚硝化的影响   总被引:1,自引:1,他引:0  
本研究采用沸石序批式反应器(ZSBR)在常温(25℃±1℃)下实现快速稳定的亚硝化,亚硝酸盐氮积累率维持在90.0%以上,并且考察了在进水氨氮500 mg·L~(-1)时,4个不同碱度(以CaCO_3计)对ZSBR亚硝化的影响.结果表明,ZSBR实现快速亚硝化的关键是游离氨(FA)对亚硝酸盐氧化菌(NOB)的抑制作用远大于其对氨氧化菌(AOB)的抑制作用,并且经此过程转化后的含氨氮的废水,可以作为厌氧氨氧化的进水,进一步脱除水中的氨氮与总氮,当系统投加碱度(以CaCO_3计)为2 500mg·L~(-1)时,ZSBR亚硝化效果最好,平均氨氮转化率为66.7%,平均亚硝酸盐氮积累率为98.1%,平均亚硝酸盐氮产率为0.74 kg·(m~3·d)~(-1).高通量测序分析表明ZSBR长时间运行后微生物群落发生显著变化,AOB得到富集,NOB在FA的抑制作用下不断被淘洗出反应器.  相似文献   

17.
生活垃圾焚烧厂渗沥液是一种含高氨氮高有机物浓度的难处理废水,目前渗沥液生物脱氮多采用多级硝化反硝化处理工艺,存在能耗大、效率低等不足。以厌氧氨氧化技术为核心,构建连续流厌氧消化-短程硝化-厌氧氨氧化三段式工艺,分析垃圾焚烧厂渗沥液的生物脱氮效果、有机物迁移转化规律、功能微生物活性及组成变化。结果表明:在进水ρ(NH4+-N)为900~1800 mg/L,ρ(COD)为3000~20000 mg/L时,系统处理效果良好,稳定运行期间总无机氮和COD去除率分别为85%和77%。其中厌氧消化段可去除约45%的COD,短程硝化段NO2--N积累率保持在97%以上,厌氧氨氧化段稳定运行期间总无机氮去除率约为85%,系统内也存在一定程度反硝化反应。接入渗沥液后,自养脱氮体系中功能微生物氨氧化菌(AOB)和厌氧氨氧化菌(Anammox)的活性均有不同程度的下降,采用宏基因组学结合16S rDNA高通量测序技术对比分析微生物的群落和功能组成变化,发现渗沥液中高浓度的有机物使短程硝化段和厌氧氨氧化段内异养反硝化菌相对丰度上升,Anammox受到难降解有机物抑制,其中Candidatus_Kuenenia菌属适应性较强,在驯化后仍然可以维持厌氧氨氧化系统较高的脱氮效果。  相似文献   

18.
戴兴春  黄民生  徐亚同  谢冰 《环境科学》2007,28(8):1882-1888
针对石化工业废水开展沸石强化脱氮处理试验研究,通过比较沸石浓度25mg/L与空白,以及沸石浓度25 mg/L与50mg/L两阶段脱氮效果,探讨沸石促进脱氮功能的机理,结果表明,曝气池中投加沸石可明显提高氨氮和总氮的去除率,硝化细菌总数和硝化功能也得到增强。与空白对照组相比, 沸石浓度25mg/L的试验组运行稳定后,氨氮去除率提高约10%~13%,总氮去除率约提高13%,出水中NO3--N含量约提高100%,氨氮与总氮之比下降6%,内源硝化耗氧呼吸速率可提高138%,硝化细菌总数是空白对照组2.2folds。沸石浓度提高到50mg/L后,试验组的脱氮效果略有增加,但效果不明显。通过对试验结果的关联分析,认为沸石提高系统脱氮能力的原因一方面是因为沸石对NH4+及硝态氮的交换吸附,另一方面NH4+离子富集于沸石表面及内部、沸石颗粒独特的好氧-缺氧微环境,以及沸石离解出CO32- 或HCO3-增加碱度等条件,促进了硝化细菌和反硝化细菌的生长,从而提高了系统脱氮能力。  相似文献   

19.
水耕植物过滤法净水系统底泥硝化反硝化潜力   总被引:14,自引:1,他引:13  
通过测定水耕植物过滤法(Hydroponic Bio-filter Method,HBFM)水质净化系统中底泥的硝化、反硝化潜力以及底泥中亚硝酸菌和硝酸菌密度,定量研究了该系统底泥的硝化及反硝化潜力沿水流方向的变化规律.结果表明,中游底泥硝化潜力最大,为4.76×10-6 g/(g·h);上游底泥反硝化潜力最大,为8.1×10-7 g/(g·h);底泥中亚硝酸菌的密度分布与硝化潜力的分布一致.结果还表明,提高HBFM系统氮去除能力的关键在于改变硝化反硝化区域分布,从而提高系统的反硝化能力.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏