首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The evaluation of a novel prototype instrument designed for on-site determinations of VOC mixtures found in indoor working environments is described. The instrument contains a miniature multi-stage preconcentrator, a dual-column separation module with pressure-tunable retention capabilities, and an integrated array of three polymer-coated surface acoustic wave sensors. It was challenged with dynamic test-atmospheres of a set of 15 common indoor air contaminants at parts-per-billion concentrations within a stainless-steel chamber under a range of conditions. Vapours were reliably identified at a known level of confidence by combining column retention times with sensor-array response patterns and applying a multivariate statistical test of pattern fidelity for the chromatographically resolved vapours. Estimates of vapour concentrations fell within 7% on average of those determined by EPA Method TO-17, and limits of detection ranged from 0.2 to 28 ppb at 25 degrees C for 1 L samples collected and analyzed in <12 min. No significant humidity effects were observed (0-90% RH). Increasing the chamber temperature from 25 to 30 degrees C reduced the retention times of the more volatile analytes which, in turn, demanded alterations in the scheduling of column-junction-point pressure (flow) modulations performed during the analysis. Reductions in sensor sensitivities with increasing temperature were predictable and similar among the sensors in the array such that most response patterns were not altered significantly. Short-term fluctuations in concentration were accurately tracked by the instrument. Results indicate that this type of instrument could provide routine, semi-autonomous, near-real-time, multi-vapour monitoring in support of efforts to assess air quality in office environments.  相似文献   

2.
Fragmented forests generate a variety of forest edges, leading to microclimates in the edge zones that differ from those in the forest interior. Understanding microclimatic variation is an important consideration for managers because it helps when making decisions about how to restrict the extent of edge effects. Thus, our study attempted to characterize the changing microclimate features at an urban forest edge located on Mt. Gwanak, Seoul, South Korea. We examined edge effects on air temperature, relative humidity, soil temperature, soil moisture, and photosynthetically active radiation (PAR) during the hottest three consecutive days in August 2016. Results showed that each variable responded differently to the edge effects. This urban forest edge had an effect on temporal changes at a diurnal scale in all microclimate variables, except soil moisture. In addition, all variables except relative humidity were significantly influenced by the edge effect up to 15 m inward from the forest boundary. The relative humidity fluctuated the most and showed the deepest extent of the edge effect. Moreover, the edge widths calculated from the relative humidity and air temperature both peaked in the late afternoon (16:00 h). Our findings provide a reference for forest managers in designing urban forest zones and will contribute to the conservation of fragmented forests in urban areas.  相似文献   

3.
The inductively coupled plasma-mass spectrometry (ICP-MS)-determined 206Pb/207Pb ratio of 145 samples of rainwater collected at 25 locations around Scotland during December 1997 and January 1998 and at three longterm monitoring stations in the northeast, central belt and southeast of the country from November 1997 to December 1998 averaged 1.144+/-0.017 (1 s). This represents a significant increase from the mean value of 1.120+/-0.016 recorded for the long-term sites in 1989 1991, only partly attributable to a concomitant increase in the 206Pb/207Pb ratio of leaded petrol from 1.075+/-0.013 to 1.088+/-0.007. The rainwater 206Pb/207Pb data for the late 1990s also contrast markedly with the lower 206Pb/207Pb ratios found for pine needle and atmospheric particulate samples from Scotland (e.g. Glasgow: 1.085+/-0.012 in 1985-1986, 1.099+/-0.007 in 1991-1992), England and Western Europe in this study for the period 1982-1992 when emissions of lead to the atmosphere from petrol-engined vehicles in the UK were approximately 2-9 times higher. The observed change in the lead isotopic signature of rainwater predominantly reflects the impact of measures, such as the introduction and growing uptake of unleaded petrol, to reduce car exhaust emissions of lead to the atmosphere in the UK. Based on the rainwater data, source apportionment calculations suggest a general decline in the contribution of leaded petrol to atmospheric lead in Scotland from 53-61% in 1989-1991 to 32-45% in 1997-1998, with a corresponding decline in the urban environment from 84-86% to 48-58%.  相似文献   

4.
青岛市区春夏季大气能见度与颗粒物的关系   总被引:6,自引:0,他引:6  
利用青岛市灰霾综合观测站2012年3月2日-2012年6月7日期间的监测数据,分析了青岛市区大气能见度与不同粒径颗粒物质量浓度的日变化特征,比较了各级别大气能见度下不同粒径颗粒物质量浓度及所占比例的相关性,研究了相对湿度对大气能见度和颗粒物质量浓度相关性的影响.结果表明,监测时段大气能见度与颗粒物质量浓度呈现较好的负相关,每天大气能见度最低值出现在早晨07:00--09:00;剔除相对湿度高于90%的前提下,PM2.5是影响大气能见度的主要因子,随着其在PM1o中所占比例上升,大气能见度级别不断下降,相关系数为-0.84;不同相对湿度区间下,PM2.5对大气能见度的影响最明显,其中,相对湿度为60% ~ 70%,大气能见度与颗粒物质量浓度之间的相关性最好.  相似文献   

5.
In this investigation properties of organic semiconductor copper phthalocyanine (CuPc) capacitive humidity and illumination sensors were studied. Organic thin film was deposited by vacuum evaporation on a glass substrate with silver surface-type electrodes to form the Ag/CuPc/Ag sensor. The capacitance of the samples was evaluated at room temperature in the relative humidity range of 35–92%. It was observed that capacitance of the Ag/CuPc/Ag sensor increases with increase in humidity. The ratio of the relative capacitance to relative humidity was about 200. It is assumed that in general the capacitive response of the sensor is associated with polarization due to absorption of water molecules and transfer of charges (electrons and holes). It was observed that under filament lamp illumination of up to 1,000 lx the capacitance of the Ag/CuPc/Ag photo capacitive detectors increased continuously by 20% as compared to dark condition. It is assumed that photo capacitive response of the sensor is associated with polarization due to transfer of photo-generated electrons and holes. An equivalent circuit of the Ag/CuPc/Ag capacitive humidity and illumination sensor was developed. Humidity and illumination dependent capacitance properties of this sensor make it attractive for use in humidity and illumination multi-meters. The sensor may be used in instruments for environmental monitoring of humidity and illumination.  相似文献   

6.
A combined NO2-SO2 Radiello radial-type diffusive sampler was validated under controlled laboratory conditions and compared with NO2-SO2 results of 3 other type of samplers in a field comparison at two locations Ghent-Mariakerke and Borgerhout in Flanders. Laboratory exposures at different temperatures (-5, 10 and 30 degrees C) and relative humidities (0, 50 and 80% RH) in combination with varying concentration levels and exposure times were carried out, with a focus on extreme conditions. Concentration level and exposure time were changed together following suppliers linear working range of samplers and assuring absolute amounts of compounds on the sampler corresponding to those of environmental levels. The average uptake rate for NO2 for 24 hour exposures at 10 degrees C and 50% RH and tested concentration levels (+/-73, 146 and 293 ppb NO2) was 0.076 +/- 0.011 ng ppb(-1) min(-1). Uptake rates during all experiments were lower than the uptake rate given in the instruction manual of the sampler. A significant effect of temperature and relative humidity on NO2 uptake rate was observed. The temperature effect from 10 to 30 degrees C corresponds to the temperature effect given by the supplier of the samplers. High relative humidity (70 to 80%) caused a strong non-reproducible decrease of uptake rate for NO2 at 24 hour experiments but this effect was not observed at longer exposures except for the tests at -5 degrees C. At the tested temperature below zero in combination with high relative humidity the sampler showed anomalous behaviour for NO2. The possible effect of concentration level and exposure time for NO2 needs further research. The average uptake rate for SO2 calculated from all exposures is 0.478 +/- 0.075 ng of sulfate ion each ppb min of SO2 and accords to suppliers uptake rate. No clear effects of temperature, relative humidity or concentration level/exposure time on the uptake rate for SO2 were found, partly due to the large scatter of results. Although NO2 accuracy of Radiello samplers was better during field campaigns than during laboratory validation, IVL and OGAWA samplers gave better results for NO2. In the field, IVL samplers showed best agreement with the continuous analyzers for both NO2 and SO2.  相似文献   

7.
Spontaneous combustion on industrial-scale stockpiles causes environmental problems and economic losses for the companies consuming large amounts of coal. In this study, an effective monitoring and prediction system based on internet was developed and implemented to prevent losses and environmental problems. The system was performed in a coal stockpile with 5 m width, 10 m length, 3 m height, and having 120 t of weight. The inner temperature data of the stockpile was recorded by 17 temperature sensors placed inside the stockpile at certain points. Additionally, the data relating to the air temperature, air humidity, atmospheric pressure, wind velocity, and wind direction that are the parameters affecting the coal stockpile were also recorded. The recorded values were analyzed with artificial neural network and Statistical modeling methods for prediction of spontaneous combustion. Real-time measurement values and model outputs were published with a web page on internet. The internet-based system can also provide real-time monitoring (combustion alarms, system status) and tele-controlling (Parameter adjusting, system control) through internet exclusively with a standard web browser without the need of any additional software.  相似文献   

8.
A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.  相似文献   

9.
通过对黑龙江省4个自然年(2016年1月1日—2019年12月31日)环境空气污染物和气象要素的分析,揭示了黑龙江省气象条件对空气污染物浓度的影响规律与特征。对PM_(2.5)、PM_(10)、SO_2、NO_2、CO和O_3等6项污染物的描述性统计和简单的相关分析显示:黑龙江省环境空气质量呈现逐年变好的趋势,非采暖期环境空气质量好于采暖期,6项污染物中除O_3呈现夏季偏高以外,其余污染物采暖期浓度均高于非采暖期。运用典型相关分析法探究环境空气污染物与温度、降水量、相对湿度、风速和气压5项气象要素之间的关系,并进行统计学检验,结果表明:环境空气污染物与气象要素之间存在显著相关,温度、风速和相对湿度对污染物具有显著影响。非采暖期大气相对湿度对PM_(10)和O_3-8h的影响显著;而在采暖期,风速对PM_(10)和PM_(2.5)的影响显著。  相似文献   

10.
The study focuses on assessing the status of respiratory morbidity in Delhi over a four years period from 2000–2003. An attempt was made to investigate the role of important pollutants (SO2, NO2, SPM and RSPM) and various meteorological factors (temperature minimum & maximum, relative humidity at 0830 and 1730 hrs. and wind speed) in being responsible for respiratory admissions on account of COPD, asthma and emphysema. The study showed that winter months had greater exposure risk as pollutants often get trapped in the lower layers of atmosphere resulting in high concentrations. Statistical analysis revealed that two pollutants have significant positive correlation with the number of COPD cases viz., SPM (r = 0.474; p < 0.01) and RSPM (r = 0.353; p < 0.05), while a meteorological factor temperature (minimum) has a significant negative correlation (r = −0.318; p < 0.05) with COPD. Stepwise multiple regression analysis was performed for COPD as dependent variable and R2 value of 0.33 was obtained indicating that SPM and RH(1730) were able to explain 33 percent variability in COPD. The partial correlation of SPM and RH(1730) on COPD was higher than any other combination and therefore they can be regarded as important contributing variables on COPD.  相似文献   

11.
利用2014年佛山市8个国控大气自动监测点位的O_3监测数据,分析了佛山市的O_3污染特征,结果表明,2014年O_3日最大8 h平均值的第90百分位数为167μg/m~3,O_3为首要污染物的超标天数为43d,占比46.7%;ρ(O_3)区域变化不大;ρ(O_3)月变化呈现"三峰型",全年高ρ(O_3)集中在6—10月份,其中7月份出现全年最高峰值;ρ(O_3)日变化呈单峰型分布,夜间浓度较低且变化平缓,14:00—16:00左右达到峰值,并存在一定的"周末效应",但并不明显;ρ(O_3)与气温呈显著正相关,与湿度、气压、雨量呈显著负相关,与风向、风速的相关性相对较弱;总体上看,高温、低湿、微风、偏南风、低压、无雨的天气条件下高ρ(O_3)更容易出现。  相似文献   

12.
Diffusive sampling of methyl isocyanate (MIC) on 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ)-coated glass fibre (GF) filters is strongly affected by high relative humidity (RH) conditions. It is shown that the humidity interference is a physical phenomenon, based on displacement of reagent from the filter surface. In this paper, this drawback has been overcome by changing the filter material to the less polar polystyrene divinyl benzene (SDB). A series of experiments was performed to compare the analyte uptake on the two filter materials for different sampling periods and analyte concentrations at both low and high RH conditions. Additionally, the materials were investigated as well for passive sampling of ethyl (EIC) and phenyl isocyanate (PhIC) with NBDPZ and 1-(2-methoxyphenyl) piperazine (2-MP) as an alternative derivatising agent. Using 2-MP, the mean GF/SDB response ratios were determined to be 1.02 for MIC (RSD: 6.1%) and 1.03 for EIC (RSD: 6.8%), whereas PhIC could only be determined on SDB filters. Using NBDPZ as reagent, the negative influence of high humidity disappeared when SDB filters were used instead of GF filters. Even at low RH conditions, sampling with SDB material generally resulted in a higher analyte uptake than with GF filters. The GF/SDB response ratios were independent of sampling time or analyte concentration and were determined to be 0.70 (RSD: 4.7%) for MIC, 0.84 (RSD: 4.5%) for EIC and 0.95 (RSD 5.4%) for PhIC, meaning that the NBDPZ diffusive sampler based on SDB can be used at all humidity conditions without any restrictions.  相似文献   

13.
This paper presents development of a first approximation of a Namibian, national level, land degradation monitoring system. The process involved a large number of stakeholders and led to the definition of four primary indicators that were regarded as related to land degradation in Namibia: population pressure, livestock pressure, seasonal rainfall and erosion hazards. These indicators were calculated annually for the period 1971–1997. Annual land degradation risk maps were produced for the same period by combining the indicators. A time series analysis of results generated by indicators was undertaken at two sites. The analysis revealed a general trend towards an increased land degradation risk over the period 1971–1997. A decrease in annual rainfall and an increase in livestock numbers caused this negative trend at one site, while decreased annual rainfall and increased human population were the causes at a second site. Evaluation of resulting maps through direct field observations and long-term monitoring at selected study sites with different conditions relevant for the indicators defined, is an essential next step.  相似文献   

14.
Quality control of long-term monitoring data of thousands and millions of individual records as present in meteorological data is cumbersome. In such data series, sensor drifts, stalled values, and scale shifts may occur and potentially result in flawed conclusions if not noticed and handled properly. However, there is no established standard procedure to perform quality control of high-frequency meteorological data. In this paper, we outline a procedure to remove sensor drift in high-frequency data series using the example of 15-year-long sets of hourly relative humidity (RH) data from 28 stations subdivided into 202 individual sensor operation periods. The procedure involves basic quality control, relative homogeneity testing, and drift removal. Significant sensor drifts were observed in 40.6 % of all sensor operation periods. The drifts varied between data series and depended in a complex, usually inconsistent way on absolute RH values; within single series for instance, a drift could be negative in the lower RH range and positive in the upper RH range. Detrending changed RH values by, on average, 1.96 %. For one fifth of the detrended data, adjustments were 2.75 % and more of the measured value, and in one tenth 4.75 % and more. Overall, drifts were strongest for RH values close to 100 %. The detrending procedure proved to effectively remove sensor drifts. The principles of the procedure also apply to other meteorological parameters and more generally to any time series of data for which comparable reference data are available.  相似文献   

15.
Petroleum hydrocarbon vapors at low ppb levels can be detected using a thickness shear mode resonator (TSMR) coated with a chemical-sensing overlayer, prepared by radiofrequency sputtering of porous sintered-polyethylene (PS-PE). The sensing capabilities of PS-PE sensors were profoundly affected by the sputtering methods; they were enhanced by the photo-excitation effect, and were reduced by carbonization and water treatment. The photo-assisted PS-PE sensor was extremely sensitive and could detect linear hydrocarbon (> C12) vapors below the ppb level. The time constant of the sorption curve, however, was large, indicating a slow sensing speed. Toward creating instrumentation for a smart environmental monitoring system, the TSMR sensors were arrayed on a circuit board equipped with a serial interface and signal processing chips of the oscillation drive and frequency counter. Co-sorption with water vapor at a relative humidity of about 10% has almost no effect on the sensing ability of PS-PE sensors for 1,2,4-trimethylbenzene. Conversely, it enhances the sensitivity of the TSMR sensor coated with a D-phenylalanine film. Upward shifts in the baseline are evident with elapsed time. However, a rigorous ten-cycle iteration test for 100 ppm toluene vapor demonstrated good reproducibility of the sensor's signals.  相似文献   

16.
In this study, the effect of relative humidity, temperature, and wind on airborne fungal allergens in the 11 different districts of Manisa City was investigated from January 2004 to December 2005. The aim of this study was to conduct a survey to get to know the relation between wind, temperature, and relative humidity and population of allergenic fungal spores in the atmosphere. A total of 792 samples were observed by using the Merck MAS100 air sampler and 12,988 fungal colonies were counted. Fourteen fungal genera could be determined; Cladosporium that was generally found as the predominant genus followed by Penicillium, Aspergillus, and Alternaria. During the entire study, seasonal variation was found to be related to atmospheric conditions especially. The optimal conditions of meteorological factors for the fungi growth resulted in the increased number of mycoflora, qualitatively and quantitatively.  相似文献   

17.
Liquid wastes from the fish meal and oil processing industries produce serious environmental impacts in coastal embayments on the coasts of Chile and Peru. This article presents an analysis of an environmental monitoring program at Lota Bay, a shallow coastal indentation in central Chile (37 degrees S) exposed to industrial fishing activity. The study of the environmental impact produced by waste effluents permitted making an evaluation of the bay's capacity for seasonal recovery from this impact. Seasonal cruises were carried out during 1994 and in 1996, 1997, and 1998. Variables analyzed included salinity, temperature, dissolved oxygen, ammonium concentration and surface oil and grease. The hydrographic regime of Lota Bay follows a seasonal pattern, where, typical of most SE pacific embayments, waters from subsuperficial oxygen minimum zones moved into the bay. The percentages of dissolved oxygen were critical in the area of organic waste discharge. The impact of wastewater is related to the type and status of the fishery, including: (i) overloads of plant production lines, (ii) maintenance and cleaning of installations, and (iii) degree of shipboard fishing conservation. Major alterations were observed in summer, when the highest discharge of organic load occurred. In winter, an improvement in the re-aeration conditions reduced the impact. Remedial measures implemented beginning in 1997 arose from the monitoring program and had to be separated into two recovery factors including (a) internal management of plants and (b) treatment of plant effluents.  相似文献   

18.
Surface barriers for waste disposal sites should preventwaste water and gas emission into the environment. It isnecessary to assess their proper operation by monitoring thewater regime of the containment. A set of three new water contentmeasuring devices has been developed that provide an economicalsolution for monitoring the moisture distribution and waterdynamic. They will give an early warning service if the barriersystem is at risk of being damaged. The cryo soil moisture sensor`LUMBRICUS' is an in situ self-calibrating absolute water contentmeasuring device. It measures moisture profiles at spot locationsdown to 2.5 m depth with an accuracy of better than 1.5% and adepth resolution of 0.03 m. The sensor inherently measuresdensity changes and initial cracks of shrinking materials likeclay minerals. The large area soil moisture sensor `TAUPE' is amoisture sensitive electric cable network to be buried in themineral barrier material of the cover. A report will be givenwith results and experiences on an exemplary installation at theWaste Disposal Facility Karlsruhe-West. 800 m2 of the barrierconstruction have been continuously monitored since December1997. Volumetric water content differences of 1.5% have beendetected and localised within 4 m. This device is alreadyinstalled in two other waste disposal sites. A modified `TAUPE'was constructed for the control of tunnels and river dams aswell. Thin sheet moisture sensor `FORMI' is specifically designedfor moisture measurements in liners like bentonite, textile andplastic. Due to its flexibility it follows the curvature of theliner. The sensor measures independently from neighbouringmaterials and can be matched to a wide range of differentthickness of the material. The sensors are patented in several countries.  相似文献   

19.
Traffic emission factors of ultrafine particles: effects from ambient air   总被引:1,自引:0,他引:1  
Ultrafine particles have a significant detrimental effect on both human health and climate. In order to abate this problem, it is necessary to identify the sources of ultrafine particles. A parameterisation method is presented for estimating the levels of traffic-emitted ultrafine particles in terms of variables describing the ambient conditions. The method is versatile and could easily be applied to similar datasets in other environments. The data used were collected during a four-week period in February 2005, in Gothenburg, as part of the G?te-2005 campaign. The specific variables tested were temperature (T), relative humidity (RH), carbon monoxide concentration (CO), and the concentration of particles up to 10 μm diameter (PM(10)); all indicators are of importance for aerosol processes such as coagulation and gas-particle partitioning. These variables were selected because of their direct effect on aerosol processes (T and RH) or as proxies for aerosol surface area (CO and PM(10)) and because of their availability in local monitoring programmes, increasing the usability of the parameterization. Emission factors are presented for 10-100 nm particles (ultrafine particles; EF(ufp)), for 10-40 nm particles (EF(10-40)), and for 40-100 nm particles (EF(40-100)). For EF(40-100) no effect of ambient conditions was found. The emission factor equations are calculated based on an emission factor for NO(x) of 1 g km(-1), thus the particle emission factors are easily expressed in units of particles per gram of NO(x) emitted. For 10-100 nm particles the emission factor is EF(ufp) = 1.8×10(15)×(1 - 0.095×CO - 3.2×10(-3)×T) particles km(-1). Alternative equations for the EFs in terms of T and PM(10) concentration are also presented.  相似文献   

20.
利用位于北京以及河北香河的两台地基Mie散射激光雷达、星载激光雷达、太阳光度计以及颗粒物监测仪等一系列仪器对发生在2008年5月底的一次沙尘事件进行立体监测并分析.结果表明,这起较严重的沙尘是由蒙古国输送而来,影响范围很广,持续时间较长,有三次明显的峰值,对应三次沙尘的来袭;沙尘的每次来袭都对应有先升温后降温的现象,并伴随有相对湿度的急剧下降;沙尘入侵前北京香河两地以细粒子为主,入侵后代之以粗粒子为主.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号