首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

2.
Lead is a purely toxic heavy metal which induces a wide variety of adverse physiologic effects. Nevertheless, it has been mined and used for more than 8,000 years. Among the different contemporary sources of lead pollution, traffic-induced emissions from the combustion of leaded gasoline is of particular concern, as it can constitute more than 90 percent of total lead emissions into the atmosphere in congested urban areas where no phase-out activities have been adopted. Gasoline lead content and traffic volume are strongly correlated with concentrations of lead in various environmental media. In the absence of policies to reduce the use of lead in gasoline or to favor the use of unleaded gasoline, leaded gasoline remains the predominant grade in many countries. This paper assesses the status of lead pollution from the combustion of leaded gasoline in Beirut based on field measurements of lead in air and roadside dust of urban and rural/suburban areas and recent data on soil and blood lead levels. Average atmospheric lead concentrations was about 1.86 microg m(-3) at urban locations and 0.147 microg m(-3) at suburban locations. The analysis of roadside dust revealed an average lead level of 353 microg g(-1) along urban streets and 125 microg g(-1) along rural/suburban roads. Blood lead levels were also relatively high in comparison to countries where leaded gasoline has been phased-out.  相似文献   

3.
A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.  相似文献   

4.
Airborne particle concentration (APC) measurements were carried out at the Sede Boker experimental station located in the northern Negev Desert, about 50 km south of Beer Sheva, during the years 1987--1997. The basic sampling period used in 1987--1993 was 12 h (day and night) and in 1994--1997 the sampling period was 24 h. For the entire study period, the average airborne particle concentration (APC) was 123.8 microg/m3, the highest value was 4204.2 microg/m3; and the lowest, near 5 microg/m3. For the 24 h average, about 90% of the cases were defined as normal situations (APC between 0-200 microg/m3) about, 8.5%, hazy periods (APC between 200-500 microg/m3), 1.4% dusty periods (APC between 500-1000 microg/m3) and about 0.7% were intense dusty periods (APC above 1000 microg/m3). Statistical analysis of the data showed significant seasonal and monthly fluctuations. The seasonal variation of the APC was further examined using different definitions of the seasons (astronomical, meteorological, and synoptic).  相似文献   

5.
An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).  相似文献   

6.
Airborne particulate matter was collected and biomonitoring of workers was performed by sampling blood, urine and hair of 84 exposed subjects, 17 occasionally exposed employees, 21 controls from administrative offices and 25 unexposed people (external controls). Determination of Pd was performed using Quadrupole and High Resolution Inductively Coupled Plasma Mass Spectrometry. The Production of Catalysts Department and the Refining Service presented the highest levels of Pd in airborne matter collected by means of an area sampler. The highest level of soluble Pd (1.66 microg m(-3)) was found in the Production of Catalysts Department. The highest concentration of Pd in airborne matter, collected by means of personal devices (7.90 microg m(-3)) was found in the Refining Service. Hair showed a clear distribution pattern among departments, with values ranging from 0.60 to 5.54 microg g(-1). Administrative workers presented blood levels of Pd between 2 and 500 times higher than external controls. Only urine levels correlated with the measurements of airborne Pd collected with personal devices. A very strong association between airborne Pd collected by personal devices and Pd levels in hair (r(2)= 0.569, with p< or = 0.01) and urine (r(2)= 0.684, with p< or = 0.01) was found. On the basis of these findings: (i) blood results appear to be an unsuitable biological marker for occupational exposure to Pd; (ii) urine could be considered as a satisfactorily responsive bio-marker for occupational monitoring; and (iii) hair cannot be considered a good index of time-related exposure.  相似文献   

7.
Aerosol constituents (elemental carbon, organic carbon, soluble ions including organic acids, and selected trace metals) were investigated from samples of a field campaign taking place at Bhola Island in the Bay of Bengal (Bangladesh). The campaign took place in the pre-monsoon season (May 2001) using low volume samplers. Carbonaceous material comprised the majority of the analysed components. The average concentrations of EC and OC were 2.8 and 4.6 microg m(-3), respectively. Oxalic acid was the most abundant dicarboxylic acid (average 268 ng m(-3)) followed by malonic and malic acid. The contribution of carboxylic acids-carbon to organic carbon was 2.0%. Average concentrations observed for sulfate and nitrate were 3.7 microg m(-3) and 1.5 microg m(-3). Two different types of aerosol were identified at the rural background site on Bhola Island during southerly synoptic flow by means of trajectory analysis: air masses were transported from the Bay of Bengal to the sampling site in all cases. However, during "Period 1" they experienced longer residence times over the Indian Ocean, while the "Period 2" trajectories came along the Indian coast or passed over the Indian continent. During Period 1 the concentration levels of soluble ions were a factor of 4-6 lower than during Period 2. The concentrations of EC, OC and K differed less than a factor of 1.5 between the two periods. The Period 1 aerosol showed similarities to the haze layers observed during winter-monsoon conditions south of India during the INDOEX experiment. Based on EC/TC and K/EC ratios we find that around 80% of the carbonaceous aerosol from Period 1 in Bhola is from fossil fuel and only around 50% from Period 2. Absolute concentrations of carbonaceous species, soluble ions and trace metals indicate that the background site on Bhola Island is affected by emissions from urbanized regions of Southeast Asia.  相似文献   

8.
The concentrations of ammonium NH4+, nitrate NO3-, and nitrite NO2- ions were recorded along with ammonia (NH(3)) emission from a fertilized rice field located in the Kwangju province in South Korea over a period of 4 months (June to October 2006). The highest magnitude of NH(3) flux was 20,754 microg m(-2) h(-1), while the average flux value over the entire sampling period was 2,395 microg m(-2) h(-1). The highest ionic concentrations were 1.67, 0.44, and 0.71 ppm for NH4+, NO3-, and NO2- ions, respectively. Possible effects of soil pH on NH(3) fluxes were detected, as they concurrently exhibited a gradual and periodic change during the sampling period. Positive correlations existed between concentrations of NH4+ and NO2- ions and the soil pH. Positive correlations also existed between NH(3) emission flux and ambient (and water) temperatures. Results indicated that fertilizer application to rice can lead to significant emission of NH(3) along with NH4+ and NO3- ions.  相似文献   

9.
The isotopic composition of lead collected with grass samples taken over the period 1989-2001 from plots at two upland locations (Glensaugh in north east and Hartwood in central Scotland) has been determined using thermal ionisation mass spectrometry. Although marked reductions in lead concentrations in grass were observed at Glensaugh in the initial three years, subsequently concentrations have remained relatively constant (1-3 microg g(-1)) in all plots to the present day. The one exception was a roadside plot at Hartwood which showed a large reduction from 1.0 microg g(-1) in 1999 to 0.2 microg g(-1) in 2000 following the abolition of petrol lead in the UK at the beginning of 2000. The total concentrations at this plot were consistently lower than those found at plots away from road traffic but exposed to the prevailing wind direction. The 206Pb/207Pb ratio increased steadily at all the plots throughout the period of the study indicating the reducing influence of petrol lead but the changes were not as great as might be expected with the decrease in the use of leaded petrol. Assuming the collected lead had only two sources, petrol lead and a diffuse background "industrial" lead, the proportion of petrol lead was only in the range 17-69% for roadside samples and 0-39% in other samples. A substantial proportion of deposited lead, therefore, now has its origin other than in petrol. Mixing curves indicate that whereas the lead deposited at Glensaugh could be defined by only two end members, that at Hartwood needs more than two components in the mixture. The results also suggest that although petrol lead has been eliminated, traffic is still a source of lead and another source defined as "traffic lead" should be considered.  相似文献   

10.
Fluxes of some Volatile Organic Compounds (VOC) from grass were measured at a golf course in western Sweden, using the Relaxed Eddy Accumulation (REA) technique. The sampling was done by collecting VOC onto adsorbent tubes and the analysis was performed by thermal desorption followed by GC/MS. High emissions were observed after cutting. Transient fluxes of (Z)-3-hexenyl acetate (0.51 microg m(-2) s(-1)), (Z)-3-hexen-1-ol (0.14 microg m(-2) s(-1)) and (Z)-3-hexenal (0.40 microg m(-2) s(-1)) were measured, even at low temperatures. The REA technique requires a relatively large fetch area that is sometimes not available. Therefore, a procedure for correcting measured fluxes from a limited fetch is suggested.  相似文献   

11.
In a cross-sectional study, 96 welders were compared with 96 control subjects. Also 27 former welders, all diagnosed as having manganism, were examined. Exposure to welding fumes was determined in the 96 welders, while the concentration of elements in whole blood and urine was determined in all subjects. The geometric mean (GM) concentrations of manganese (Mn) and iron in the workroom air were 97 microg m(-3) (range 3-4620 microg m(-3); n=188) and 894 microg m(-3) (range 106-20 300 microg m(-3); n=188), respectively. Thus the Mn concentration in the workroom air was on average 10.6% (GM) of that of the Fe concentration. No substantial difference was observed in the air Mn concentrations when welding mild steel as compared to welding stainless steel. The arithmetic mean (AM) concentration of Mn in whole blood (B-Mn) was about 25% higher in the welders compared to the controls (8.6 vs. 6.9 microg l(-1); p < 0.001), while the difference in the urinary Mn concentrations did not attain statistical significance. A Pearson's correlation coefficient of 0.31 (p < 0.01) was calculated between B-Mn and Mn in the workroom air that was collected the day before blood sampling. Although the exposure to welding fumes in the patients had ceased on average 5.8 years prior to the study (range 4 years-7 years), their AM B-Mn concentration was still higher than in referents of similar age (8.7 microg l(-1) vs. 7.0 microg l(-1)). However, their urinary concentrations of cobolt, iron and Mn were all statistically significantly lower.  相似文献   

12.
A method based on SPME is described for assessing the gaseous dichlorvos concentration in confined atmospheres like a greenhouse after a pesticide application. Sampling was made by using SPME with PDMS fibres immersed into a 250 mL sampling flask into which air samples were dynamically pumped from the analysed atmosphere. Sampling duration was 40 min and samples were then analysed by GC-MS. Calibration was performed from a vapour saturated air sample and gas phase diluted samples, and this procedure afforded a curve with a regression coefficient (R2) higher than 0.98. The repeatability of these measurements was observed with an RSD of 2.5%. This analysis procedure was then applied for the determination of gaseous dichlorvos concentrations versus time, in the atmosphere of an experimental 8 m2 and 20 m3 greenhouse. The pesticide was sprayed according to real cultivation conditions and measurements were made from 2 up to 74 h after application affording observed concentrations in the range of decades and hundreds of microg m(-3) (corresponding limits of detection and quantification were found at the level of a few microg m(-3)).  相似文献   

13.
A denuder/filter system constructed for solvent-free personal exposure measurements was evaluated for separation of vapour and particulate 4,4'-methylenediphenyl diisocyanate (4,4'-MDI) generated from heated PUR-foam. The two different phases were collected in the denuder and on the filter, respectively, by chemosorption on a polydimethylsiloxane (SE-30)-dibutylamine (DBA) stationary phase. Both repeatability and the total mass concentration of 4,4'-MDI were similar to that obtained from the reference method, in this case an impinger/filter system. The penetration of particles through the denuder at 300 ml min(-1) was nearly 100% in the particle size range 25 to 700 nm, which fits well with the Gormley-Kennedy equation. Denuder/filter sampling of the 4,4'-MDI aerosol at 500 ml min(-1) yielded a phase distribution that was in accordance with the results from the reference method. The method limit of detection was 6 ng m(-3) and 4 ng m(-3) for the denuder and filter, respectively, when using an air sampling flow rate of 300 ml min(-1) and a sampling period of 15 min. This is well below the Swedish occupational exposure limit (OEL) of 50 and 100 microg m(-3) for an 8-hour working day and a 5-min period, respectively.  相似文献   

14.
2-Ethyl-1-hexanol is a possibly causative chemical in sick building symptoms, although 2-ethyl-1-hexanol has received little attention as a hazardous substance in studies on indoor air pollution. Airborne 2-ethyl-1-hexanol concentrations were measured from 2002 to 2004 in 99 rooms of 42 non-domestic buildings in Nagoya, Japan. The diffusive sampling method is effective for the measurement of a low level of 2-ethyl-1-hexanol in indoor air. The geometric mean (geometric standard deviation) of 2-ethyl-1-hexanol concentrations was 16.5 (5.4) microg m(-3) in indoor air and 1.9 (2.2) microg m(-3) in outdoor air. The maximum concentration of 2-ethyl-1-hexanol in indoor air and outdoor air was 2709 microg m(-3) and 12.4 microg m(-3), respectively. Fewer rooms in a small number of new buildings showed high concentrations of 2-ethyl-1-hexanol, while low concentrations were observed in many rooms of these buildings as well as the other new buildings. The room-to-room concentrations of 2-ethyl-1-hexanol in each building exhibited a wide variation. The geometric mean of the 2-ethyl-1-hexanol concentrations was significantly higher for indoor air than for outdoor air (p < 0.01). The correlation of the 2-ethyl-1-hexanol concentrations between indoor and outdoor air was not significant. Mechanical ventilation was effective in the temporary reduction of indoor 2-ethyl-1-hexanol level. These results suggest that the predominant source of 2-ethyl-1-hexanol was indoor areas.  相似文献   

15.
A temporary renovation activity releases considerably high concentrations of particulate matter, viable and non-viable, into air. These pollutants are a potential contributor to unacceptable indoor air quality (IAQ). Particulate matter and its constituents lead, sulfate, nitrate, chloride, ammonium and fungi as well as fungal spores in air were evaluated in a building during renovation action. Suspended dust was recorded at a mean value of 6.1 mg m(-3) which exceeded the Egyptian limit values for indoor air (0.15 mg m(-3)) and occupational environments (5 mg m(-3)). The highest particle frequency (23%) of aerodynamic diameter (dae) was 1.7 microm. Particulate sulfate (SO(4)(2-)), nitrate (NO(3)(-)), chloride (Cl(-)), ammonium (NH(4)(+)) and lead components of suspended dust averaged 2960, 28, 1350, 100 and 13.3 microg m(-3), respectively. Viable fungi associated with suspended dust and that in air averaged 1.11 x 10(6) colony forming unit per gram (cfu g(-1)) and 92 colony forming unit per plate per hour (cfu p(-1) h(-1)), respectively. Cladosporium(33%), Aspergillus(25.6%), Alternaria(11.2%) and Penicillium(6.6%) were the most frequent fungal genera in air, whereas Aspergillus(56.8%), Penicillium(10.3%) and Eurotium(10.3%) were the most common fungal genera associated with suspended dust. The detection of Aureobasidium, Epicoccum, Exophiala, Paecilomyces, Scopulariopsis, Ulocladium and Trichoderma is an indication of moisture-damaged building materials. Alternaria, Aureobasidium, Cladosporium, Scopulariopsis and Nigrospora have dae > 5 microm whereas Aspergillus, Penicillium and Verticillium have dae < 5 microm which are suited to penetrate deeply into lungs. Particulate matter from the working area infiltrates the occupied zones if precautionary measures are inadequate. This may cause deterioration of IAQ, discomfort and acute health problems. Renovation should be carefully designed and managed, in order to minimize degradation of the indoor and outdoor air quality.  相似文献   

16.
Ambient ammonia concentrations, mainly originating from agricultural activities, have increased in the last few decades in Europe. As a consequence, critical loads on oligotrophic ecosystems such as forests and mires are greatly exceeded. Monitoring of ambient ammonia concentrations is necessary in order to investigate source-receptor relationships. Measuring ambient ammonia concentrations continuously with high time resolution is very expensive and cost-efficient systems are required. Where time resolution is of minor importance, several cost-effective systems, mainly dry denuder and passive samplers, can be applied. In this paper the Zürcher passive sampler, a diffusive sampling system, is presented. It is a Palmes type sampler with an acidic solution as absorbent and is easy to handle. It was tested at 46 sites in Switzerland over one year. The average concentration in ambient air was 2.5 microg m(-3) +/- 0.4 microg m(-3). The average of the blank values were 0.21 microg m(-3). The detection limit (double the standard deviation of the blank values) was 0.36 microg m(-3). Three passive samplers were exposed at each site and each period. The mean standard deviation of these triplicate measurements was 9.5%. Compared with a discontinuous tubular denuder system and a continuous annular denuder system, the deviation was less than 10%. The Zürcher passive sampler is a useful and cost-efficient tool to determine long-term average ammonia concentrations (one- to four-week periods) in ambient air for mean concentrations above 1 microg m(-3).  相似文献   

17.
The thermal degradation products of polyurethanes (PURs) and exposure to isocyanates were studied by stationary and personal measurements in five different occupational environments. Isocyanates were collected on glass fibre filters impregnated with 1-(2-methoxyphenyl)piperazine (2MP) and in impingers containing n-dibutylamine (DBA) in toluene. connected to a glass fibre postfilter. The derivatives formed were analysed by liquid chromatography: 2MP derivatives with UV and electrochemical detection and DBA derivatives with mass spectrometric detection. The release of aldehydes and other volatile organic compounds into the air was also studied. In a comparison of the two sampling methods, the 2MP method yielded about 20% lower concentrations for 4,4'-methylenediphenyl diisocyanate (MDI) than did the DBA method. In car repair shops, the median concentration of diisocyanates (given as NCO groups) in the breathing zone was 1.1 microg NCO m(-3) during grinding and 0.3 microg NCO m(-3) during welding, with highest concentrations of 1.7 and 16 pg NCO m(-3), respectively. High concentrations of MDI, up to 25 and 19 microg NCO m(-3), respectively, were also measured in the breathing zone during welding of district heating pipes and turning of a PUR-coated metal cylinder. During installation of PUR-coated floor covering, small amounts of aliphatic diisocyanates were detected in the air. A small-molecular monoisocyanate, methyl isocyanate, and isocyanic acid were detected only during welding and turning operations. The diisocyanate concentrations were in general higher near the emission source than in the workers' breathing zone. A sampling strategy to evaluate the risk of exposure to isocyanates is presented.  相似文献   

18.
Principal component analysis (PCA) coupled with a multilinear regression analysis (MLRA) was applied to PM(10) speciation data series (2002-2005) from four sampling sites in a highly industrialised area (ceramic production) in the process of implementing emission abatement technology. Five common factors with similar chemical profiles were identified at all the sites: mineral, regional background (influenced by the industrial estate located on the coast: an oil refinery and a power plant), sea spray, industrial 1 (manufacture and use of glaze components, including frit fusion) and road traffic. The contribution of the regional background differs slightly from site to site. The mineral factor, attributed to the sum of several sources (mainly the ceramic industry, but also with minor contributions from soil resuspension and African dust outbreaks) contributes between 9 and 11 microg m(-3) at all the sites. Source industrial 1 entails an increase in PM(10) levels between 4 and 5 microg m(-3) at the urban sites and 2 microg m(-3) at the suburban background site. However, after 2004, this source contributed less than 2 microg m(-3) at most sites, whereas the remaining sources did not show an upward or downward trend along the study period. This gradual decrease in the contribution of source industrial 1 coincides with the implementation of PM abatement technology in the frit fusion kilns of the area. This relationship enables us to assess the efficiency of the implementation of environmental technologies in terms of their impact on air quality.  相似文献   

19.
Daily PM10 concentrations were measured at four sampling stations located in Chiang Mai and Lamphun provinces, Thailand. The sampling scheme was conducted during June 2005 to June 2006; every 3 days for 24 h in each sampling period. The result revealed that all stations shared the same pattern, in which the PM10 (particulate matters with diameter of less than 10 microm) concentration increased at the beginning of dry season (December) and reached its peak in March before decreasing by the end of April. The maximum PM10 concentration for each sampling station was in the range of 140-182 microg/m(3) which was 1.1-1.5 times higher than the Thai ambient air quality standard of 120 microg/m(3). This distinctly high concentration of PM10 in the dry season (Dec. 05-Mar. 06) was recognized as a unique seasonal pattern for the northern part of Thailand. PM10 concentration had a medium level of negative correlation (r = -0.696 to -0.635) with the visibility data. Comparing the maximum PM10 concentration detected at each sampling station to the permitted PM10 level of the national air quality standard, the warning visibility values for the PM10 pollution-watch system were determined as 10 km for Chiang Mai Province and 5 km for Lamphun Province. From the analysis of PM10 constituents, no component exceeded the national air quality standard. The total concentrations of PM10-bond polycyclic aromatic hydrocarbons (PAHs) are calculated in terms of total toxicity equivalent concentrations (TTECs) using the toxicity equivalent factors (TEFs) method. TTECs in Chiang Mai and Lamphun ambient air was found at a level comparable to those observed in Nagasaki, Bangkok and Rome and at a lower level than those reported at Copenhagen. The annual number of lung cancer cases for Chiang Mai and Lamphun Provinces was estimated at two cases/year which was lower than the number of cases in Bangkok (27 cases/year). The principal component analysis/absolute principal component scores (PCA/APCS) model and multiple regression analysis were applied to the PM10 and its constituents data. The results pointed to the vegetative burning as the largest PM10 contributor in Chiang Mai and Lamphun ambient air. Vegetative burning, natural gas burning & coke ovens, and secondary particle accounted for 46-82%, 12-49%, and 3-19% of the PM10 concentrations, respectively. However, natural gas burning & coke ovens as well as vehicle exhaust also deserved careful attention due to their large contributions to PAHs concentration. In the wet season and transition periods, 42-60% of the total PAHs concentrations originated from vehicle exhaust while 16-37% and 14-38% of them were apportioned to natural gas burning & coke ovens and vegetative burning, respectively. In the dry period, natural gas burning & coke ovens, vehicle exhaust, and vegetative burning accounted for 47-59%, 20-25%, and 19-28% of total PAHs concentrations. The close agreement between the measured and predicted concentrations data (R(2) > 0.8) assured enough capability of PCA/APCS receptor model to be used for the PM10 and PAHs source apportionment.  相似文献   

20.
This study used manual air sampling method to assess the contribution of road traffic to air pollution level in Dar-es-Salaam City, Tanzania. Samples were collected from 11 different sites. Parameters measured were: sulphur dioxide using pararosaniline method, nitrogen dioxide using saltzman method, particulate matter and particulate lead using filtration method and atomic absorption spectrometric method, respectively. Results showed that hourly average sulphur dioxide concentration range from 127 to 1385 g/m3. The measured values of sulphur dioxide were above the recommended WHO guidelines with an hourly objective value of 350 g/m3 at 87% of the sampling sites. The hourly average nitrogen dioxide concentration ranged from 18 to 53 g/m3. The maximum hourly nitrogen dioxide concentration at 53 g/m3 was below the WHO guideline value of 200 g/m3. The hourly average suspended particulate matter (SPM) ranged from 98 to 1161 g/m3, exceeding the recommended value of 230 g/m3 by WHO at 87% of the sampling sites. The hourly average lead concentration was found to range from 0.60 to 25.6 g/m3, exceeding again the WHO guideline value of 1.5 g/m3at 83% of the sampling sites. Results predicted by Gaussian model when compared with the measured values were found to have a correlation coefficient of 0.8, signifying a good correlation. The risk assessment was undertaken considering the people who spend a significant portion of their time near the roads, such as the Uhuru primary school pupils and the adult population who reside by the roadside. The unit risk realised was 18.2 × 10–6 for adult population and 2.2 × 10–6 for pupils, both scenarios showing risk higher than the United Sates of America Environmental Protection Agency (USEPA) acceptable limit of 1× 10–6. Considering the magnitude of the problem at hand, this study recommends an introduction of mandatory emission tests of SPM, lead and sulphur dioxide (SO2). The study further recommends the introduction of continuous and/or regular air quality monitoring and the use non-leaded petrol in Tanzania.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏