采用固相萃取-高效液相色谱法测定水中7种氯酚类化合物,Waters OASIS WAX柱萃取效率最高,最佳萃取时间和洗脱时间分别为60和5 min。该法的线性范围为1.0~40 mg/L,检出限为0.015~0.5μg/L,精密度为0.558%~2.22%,回收率为83.2%~105%。该法适用于地表水及饮用水中氯酚类化合物的检测。  相似文献   

2.
In this work, spectrophotometer was used as a detector for the determination of uranium from water, biological, and ore samples with a flow injection system coupled with solid phase extraction. In order to promote the online preconcentration of uranium, a minicolumn packed with XAD-4 resin impregnated with nalidixic acid was utilized. The system operation was based on U(VI) ion retention at pH 6 in the minicolumn at flow rate of 15.2 mL min?1. The uranium complex was removed from the resin by 0.1 mol dm?3 HCl at flow rate of 3.2 mL min?1 and was mixed with arsenazo III solution (0.05 % solution in 0.1 mol dm?3 HCl, 3.2 mL min?1) and driven to flow through cell of spectrophotometer where its absorbance was measured at 651 nm. The influence of chemical (pH and HCl (as eluent and reagent medium) concentration) and flow (sample and eluent flow rate and preconcentration time) parameters that could affect the performance of the system as well as the possible interferents was investigated. At the optimum conditions for 60 s preconcentration time (15.2 mL of sample volume), the method presented a detection limit of 1.1 μg L?1, a relative standard deviation (RSD) of 0.8 % at 100 μg L?1, enrichment factor of 30, and a sample throughput of 42 h?1, whereas for 300 s of the preconcentration time (76 mL of sample volume), a detection limit of 0.22 μg L?1, a RSD of 1.32 % at 10 μg L?1, enrichment factor of 150, and a sampling frequency of 11 h?1 were reported.  相似文献   

3.
A novel improved preconcentration method known as rapidly synergistic cloud point extraction (RS-CPE) was established for nickel preconcentration and determination prior to its determination by flame atomic absorption spectrometry. In this work, the traditional CPE pattern was changed and greatly simplified in order to be applicable in metal extraction and detection. This method was accomplished in room temperature in 1 min. Non-ionic surfactant Triton X-114 was used as extractant. Octanol worked as cloud point revulsant and synergic reagent. The various parameters affecting the extraction and preconcentration of nickel such as sample pH, 2,2′-Furildioxime concentration, amounts of octanol, amounts of Triton X-114, type of diluting solvent, extraction time, and ionic strength were investigated and optimized. Under optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 2–200 μg L?1, and the limit of detection was 0.6 μg L?1 for nickel. The developed method was successfully applied for the determination of nickel in food and water samples. The results showed that, the proposed method can be used as a cheap, rapid, and efficient method for the extraction and preconcentration of nickel from real samples.  相似文献   

4.
A new method has been developed for the determination of gold based on separation and preconcentration using silica gel modified with benzoylthiourea. The optimum experimental parameters for preconcentration of gold, such as acid concentration, sample flow rate, eluent and matrix ions, have been investigated. Gold could be quantitatively retained in the 0.25-2.0 mol L(-1) HCl and HNO(3) concentrations, and then eluted completely with 0.5 mol L(-1) thiourea in 1.0 mol L(-1) HCl. The sorption capacity of gold(III) is 0.92 +/- 0.04 mmol g(-1) with a high enrichment factor of 267. The relative standard deviation of the method, RSD%, was found as 1.2% for 0.1 microg mL(-1). The detection limit for gold was 1.4 microg L(-1). The validation of the proposed method was checked by the analysis of certified reference soil materials. The presented procedure was applied to the determination of gold in some environmental samples.  相似文献   

5.
Amberlite XAD-4 resin functionalized with β-nitroso-α-naphthol was applied to an online system for the preconcentration and determination of uranium. U (VI) ions were retained on the minicolumn at an appropriate pH and then desorbed with acid solution. The amount of uranium in the eluate was measured spectrophotometrically at 650 nm using Arsenazo III as a colorimetric reagent. The limit of detection and the preconcentration factor were 1.8 μg L???1 and 10, respectively. The chemical and flow variables affecting the preconcentration were studied. The influence of several ions on the system was also investigated. The method was successfully applied for the evaluation of uranium in water and in effluent samples.  相似文献   

6.
A method is presented for the determination of isocyanic acid (ICA), HNCO, in air samples as a di-n-butylamine (DBA) derivative. The method is based on sampling in midget impinger flasks containing 10 ml of 0.01 mol l-1 DBA in toluene. Quantification was made using liquid chromatography (LC) and electrospray mass spectrometry (MS) monitoring positive ions. The instrumental detection limit for the LC-MS was 10 fmol of ICA-DBA. ICA was generated by thermal decomposition of urea. A standard solution containing the DBA derivatives of ICA was prepared by collecting the emitted ICA in an impinger flask containing DBA. ICA in the reference solution was characterised by LC and time-of-flight (TOF) MS and quantified by LC chemiluminescent nitrogen detection (LC-CLND). The instrumental detection limit for the LC-CLND was 1 ng of nitrogen. ICA was emitted during thermal degradation of PFU resins and polyurethane (PUR) lacquers, from car metal sheets. ICA was the most dominant isocyanate and in PUR coating up to 8% of the total weight was emitted as ICA and for PFU resins up to 14% was emitted as ICA. When air samples were collected in an iron foundry during casting in sand moulds with furan resins, concentrations of ICA in the range 50-700 micrograms m-3 were found in the working atmosphere.  相似文献   

7.
A new method for separation and preconcentration of trace amounts of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) ions in various matrices was proposed. The method is based on the adsorption and chelation of the metal ions on a column containing Amberlite XAD-1180 resin impregnated with 1-(2-thiazolylazo)-2-naphthol (TAN) reagent prior to their determination by flame atomic absorption spectrometry (FAAS). The effect of pH, type, concentration and volume of eluent, sample volume, flow rates of sample and elution solutions, and interfering ions have been investigated. The optimum pH for simultaneous retention of all the metal ions was 9. Eluent for quantitative elution was 20 ml of 2 mol l(-1) HNO(3). The optimum sample and eluent flow rates were found as 4 ml min(-1), and also sample volume was 500 ml, except for Mn (87% recovery). The sorption capacity of the resin was found to be 0.77, 0.41, 0.57, and 0.30 mg g(-1) for Cu(II), Ni(II), Cd(II), and Mn(II), respectively. The preconcentration factor of the method was 200 for Cu(II), 150 for Pb(II), 100 for Cd(II) and Ni(II), and 50 for Mn(II). The recovery values for all of the metal ions were > or = 95% and relative standard deviations (RSDs) were < or = 5.1%. The detection limit values were in the range of 0.03 and 1.19 microg l(-1). The accuracy of the method was confirmed by analysing the certified reference materials (TMDA 54.4 fortified lake water and GBW 07605 tea samples) and the recovery studies. This procedure was applied to the determination of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) in waste water and lake water samples.  相似文献   

8.
A procedure is detailed for the selective analysis of trace aluminum by flame atomic absorption spectrophotometer coupled with off-line column separation and preconcentration. Chelating resin was synthesized by covalent functionalization of Amberlite XAD-16 by 2-(2-hydroxyphenyl) benzoxazole. The modified resin was characterized using FT-IR spectroscopy, energy dispersive x-ray analysis, elemental analysis, thermogravimetric analysis/differential thermal analysis, and minimum energy run. The optimum sorption was at pH 9?±?0.1 with corresponding t 1/2 of only 7 min. Many competitive anions and cations studied did not interfere at all in the selective determination of Al(III), at the optimized conditions. The resin shows maximum sorption capacity of 21.58 mg g?1 and can be regenerated up to 75 cycles without any discernible capacity loss. The Langmuir isotherm model provides the better correlation of the experimental data (r 2?=?0.999) in comparison to Freundlich isotherm model, while the Scatchard analysis revealed homogeneous binding sites in the chelating resin. Analytical figures of merit were evaluated by accuracy (standard reference materials and recovery experiment), precision (RSD <5 %), and detection limit (2.8 μg L?1). The applicability was demonstrated by analysis of trace aluminum in biological, environmental, and food samples.  相似文献   

9.
A procedure for the determination of atmospheric acrylic acid in air at the microgram m-3 to mg m-3 level is described. Diffusion-based sampling, designed to discriminate gaseous analytes from their particulate counterparts, has been used. Acrylic acid is collected with an efficiency of > 98% in tubular denuders coated with sodium hydroxide-barium hydroxide-hydroquinone monomethyl ether, and analyzed by high performance liquid chromatography with UV absorbance detection. The detection limit is 2.9 micrograms m-3 at a flow rate of 0.5 L min-1 and 30 min sampling time. A precision (p = 0.95, n = 10) of 7.5% of the overall procedure was achieved at the 100 micrograms m-3 level. Results of laboratory studies concerning the effect of the coating reagent and the relative humidity on the sampling efficiency as well as possible interferences, in particular by ozone, and the elimination of these interferences are discussed. This method was developed to monitor workplace atmospheres as well as ambient air in industrial environments.  相似文献   

10.
In this paper, a method involving on-line preconcentration with cloud point extraction for the determination of cadmium in biological samples is presented. The procedure is based on the sorption of micelles containing Cd(II) ions and the reagent 4-(5'-bromo-2'-thiazolylazo)orcinol (Br-TAO) in a minicolumn packed with polyester. The surfactant Triton X-114 was used in the formation of micelles. After sorption, the Cd(II) ions were desorbed from the minicolumn with acid eluent and determined by flame atomic absorption spectrometry. Parameters influencing the cloud point extraction were studied. The method showed a detection limit of 0.5 μg l(-1) and an enhancement factor of 27. The accuracy was tested by determination of cadmium in certified reference materials (spinach leaves 1570a and tomato leaves 1573a) from the National Institute of Standards and Technology.  相似文献   

11.
采用在线蒸馏-无人值守连续流动分析法对污水中氨氮进行检测,方法在0.00~10.0 mg/L范围内线性良好,检出限为0.014 mg/L,实际样品测定的相对标准偏差为1.24%~4.15%,加标回收率为93.0%~108%,精密度和准确度均能满足污水中氨氮的测定要求。  相似文献   

12.
高效液相色谱法测定地表水中四乙基铅   总被引:1,自引:1,他引:0  
系统研究了地表水中四乙基铅的液相色谱分析方法,水中四乙基铅经二氯甲烷萃取浓缩后,用高压液相色谱柱分离,在280 nm波长处检测,根据保留时间定性,外标法定量,检出限及测定下限分别为0.02μg/L和0.06μg/L,低于地表水限值0.1μg/L,地表水平行测定的相对标准偏差均小于5%,地表水和废水样品加标回收率分别为79.4%~82.0%和62.5%~106.6%。  相似文献   

13.
In the present study, a separation/preconcentration procedure for determination of aluminum in water samples has been developed by using a new atomic absorption spectrometer concept with a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator, and a charge-coupled device array detector. Sample solution pH, sample volume, flow rate of sample solution, volume, and concentration of eluent for solid-phase extraction of Al chelates with 4-[(dicyanomethyl)diazenyl] benzoic acid on polymeric resin (Duolite XAD-761) have been investigated. The adsorbed aluminum on resin was eluted with 5 mL of 2 mol L-1 HNO3 and its concentration was determined by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Under the optimal conditions, limit of detection obtained with HR-CS FAAS and Line Source FAAS (LS-FAAS) were 0.49 μg L?1 and 3.91 μg L?1, respectively. The accuracy of the procedure was confirmed by analyzing certified materials (NIST SRM 1643e, Trace elements in water) and spiked real samples. The developed procedure was successfully applied to water samples.  相似文献   

14.
Two hydride generation manifold systems, utilizing flow injection and cryotrapping techniques for alkyl-metal(loid) speciation analysis in natural waters, are described in this paper. They provide shipboard capacity for simultaneous derivatization of analytes with NaBH4 and cryotrapping of the generated products in a field packed column at -196 degrees C. The first system is a large-volume hydride generator, using a reagent-injection flow technique as a flow batch type, that has been fully optimized and applied to the simultaneous detection of alkylated species in estuarine waters. The technique permits the analysis of a large volume sample (0.5-11) at a sampling rate of 3 h-1. The second is an online continuous flow hydride generator. A sampling rate of 3-12 h-1 can be achieved with samples of 0.1-0.51. In addition, shipboard operation eliminates major problems related to sample pretreatment, transport and storage. Ultra-trace multi-element determination is finally performed in the laboratory by cryogenic GC hyphenated with ICP-MS. Routine detection limits of 0.5-10 pg (as metal) for 0.51 water samples were achieved for the selected alkyl-metal(loid) species of arsenic, germanium, mercury and tin. Concentrations of various species, obtained from water samples taken from the Rhine estuary, are also presented. These species include alkylated arsenic compounds, other than methyl derivatives, that have been tentatively identified and are reported here for the first time.  相似文献   

15.
A method is presented for the determination of antimony in whole human blood samples with an ICP-MS instrument using a quadrupole mass analyzer. A nitric acid/hydrogen peroxide open digestion procedure was employed for the blood sample treatment and preparation for analysis. The precision and accuracy of the method were evaluated by analyzing several Seronorm trace elements whole blood reference materials. The precision of the method at various antimony levels was better than 4% RSD and the recovery was greater than 92% at all levels. The detection limit, calculated as three times the standard deviation of the blank (3sigma, n= 12), was 0.03 microg L(-1). The method was successfully applied for the determination of antimony in blood samples from school children in rural areas of Kwazulu/Natal, South Africa and adults from Dearborn, Michigan. Blood antimony levels ranged from <0.03 to 3.82 microg L(-1) in children and 1.40 to 4.35 microg L(-1) for adults.  相似文献   

16.
建立了高压密封消解-流动注射同时测定海水中总氮和总磷的方法,方法采用特制聚四氟乙烯密封消解罐,经高压消解锅消解后,用流动注射分析仪同时测定海水中的总氮和总磷。结果显示,总氮和总磷在0~3.20 mg/L范围内线性良好,总氮相关系数(r)=0.9997,检出限为0.012 mg/L,相对标准偏差为0.65%~2.59%,加标回收率为97.8%~102%;总磷相关系数(r)=0.9999,检出限为0.006 mg/L,相对标准偏差为0.50%~6.67%,加标回收率为98.8%~101%。该方法可同时测定海水中总氮和总磷,方法准确度和精密度良好,满足分析要求,适用于大批量海水样品中总氮和总磷的快速准确定量。  相似文献   

17.
The present study reports on the application of modified groundnut shell as a new, easily prepared, and stable sorbent for the extraction of trace amount of Cr(III) in aqueous solution. 2-Hydroxybenzaldiminoglycine was immobilized on groundnut shells in alkaline medium and then used as a solid phase for the column preconcentration of Cr(III). The elution was carried out with 3 mL of 2 mol?L?1 HCl. The amount of eluted Cr(III) was determined by spectrophotometry using cefaclor as a complexing reagent and by flame atomic absorption spectrometry (FAAS). Different experimental variables such as pH, amount of solid sorbent, volume and concentration of eluent, sample and eluent flow rate, and interference of other metal ions on the retention of Cr(III) were studied. Under the optimized conditions, the calibration curves were found to be linear over the concentration range of 13–104 and 10–75 μg?L?1 with a detection limit of 3.64 and 1.24 μg?L?1 for spectrophotometric method and FAAS, respectively. An enrichment factor of 200 and RSD of ±1.19–1.49 % for five successive determinations of 25 μg?L?1 were achieved. The column preconcentration was successfully applied to the analysis of tap water and underground water samples.  相似文献   

18.
流动注射分光光度法在线分析水中总铁   总被引:3,自引:0,他引:3       下载免费PDF全文
采用流动注射邻菲哕啉分光光度法在线分析水中总铁,考察了显色剂、消解液、酸度、反应盘管长度、载流流量、注样体积、采样时间等因素对试验的影响。方法在0.100mg/L-10.0mg/L范围内线性良好,检出限为0.04mg/L,实际水样平行测定的RSD≤3.7%,加标回收率为95.0%-96.0%。  相似文献   

19.
采用微波消解-原子荧光光谱法测定大气细颗粒物中的砷,确定了最佳样品处理方法与测定条件。方法在0μg/L~40.0μg/L范围内线性良好,标准曲线相关系数达0.999以上,检出限为0.01μg/L。土壤标准品的测定值在标准值范围内,大气PM2.5滤膜样品加标回收率为96.0%~102%,5次平行测定的RSD为1.5%~3.6%。  相似文献   

20.
A simple and sensitive method was developed for determination of trace copper by direct precipitation preconcentration and detection with Flame Atomic Absorption Spectrometry (FAAS). The reagent 2-[2'-(6-methyl-benzothiazolylazo)]-4-aminophenol (Me-BTAP) was used as precipitating agent. The experimental conditions for the quantitative precipitation of copper, such as pH, amount of reagents, temperature and the effect of diverse ions on the precipitation have been investigated. It was found that copper is quantitatively extracted (> or =95%) and the method provides a sensitivity enhancement of 40-fold for a 10 ml sample volume with a detection limit of 0.5 microg l(-1). The proposed method was successfully applied for the determination of trace copper in water, urine and biological samples.  相似文献   