首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ash samples collected from medical, municipal and small-scale domestic incinerators in Japan were tested for dioxin-like activity using bioassay technique (ethoxyresorufin-O-deethylase: EROD assay) and for extractable organohalogens (EOX) using instrumental neutron activation analysis in order to estimate potential toxicity and responsible chemicals in those samples. Crude extracts and fractions cleaned-up for dioxin analysis from the samples were used for the analysis. The ranges of dioxins in the ashes were between 2.23 and 12.29 ng TEQ/g (dry weight). Relative potency ranges estimated by EROD assay in the medical incinerator ashes were 3.8-17.6 times higher than the results of conventional chemical analysis. EOX analysis suggested that ash samples contained plenty of organochlorine compounds apart from chlorinated dioxins. In addition, medical waste incinerator ashes were considered to have relatively higher amount of organoiodine compounds. In the cleaned-up fractions, bioassay potency ranges were lower than those in the crude extracts. However, some samples still exhibited higher potency than expected from chemical analysis. Though some polycyclic aromatic hydrocarbons were found in the fractions, the amounts were relatively low (0.39-10.56 ng/g). The results imply that some bioactive organohalogens that cannot be detected in the conventional chemical analysis might have potential for dioxin-like toxicity, and contribute to higher bioassay activities. The combination of the chemical analysis with the bioassay and EOX provides rough figure of dioxin-like toxicity and suggests types of organohalogen compounds that should be identified as a part of dioxin analysis for control emission from an incineration plant.  相似文献   

2.
Chemically-activated luciferase gene expression (CALUX) bioassay and gas chromatography/mass spectrometry (GC/MS) are used to determine dioxin levels in food and humans. Valid measures of the agreement between the two methods would improve interpretation of bioassay results. Paired breast milk samples from 250 mothers, as 11 pooled samples, were analysed by GC/MS for total WHO-TEQ (7 polychlorinated dibenzo-para-dioxins, 10 polychlorinated dibenzofurans and 12 dioxin-like polychlorinated biphenyls) and as individual samples by CALUX. Mean difference between total WHO-TEQ (weighted by TEF system derived in 1997) and mean CALUX-TEQ in each pool was 1.6 pg/g fat (95% CI: 0.7, 2.4), indicating a statistically significant overestimation of CALUX-TEQ compared to WHO-TEQ, probably due to the presence of Ah-receptor agonists. CALUX estimated toxicity of 13 pg/g fat was greater than the WHO-TEQ by 0.9, 3.1 and 0.3 pg/g fat for mothers from Hong Kong, mainland China and overseas territories, respectively. When the 2005 TEF system was applied, a reduction of 14-26% in the WHO-TEQ and a larger but less disperse discrepancy between WHO-TEQ and CALUX-TEQ (3.9 pg/g fat, 95% CI: 3.5, 4.4) were observed. Our study suggested that the mothers' place of residence explained the discrepancy between CALUX-TEQ and WHO-TEQ and should be considered in inter-country comparisons for CALUX-TEQ. For regulatory purposes bioassays for detecting quantitative dioxin contents in any setting must be combined with adequate extraction, clean-up and validation with WHO-TEQs. The larger difference between the two measurements after using the new TEF system warrants further investigation.  相似文献   

3.
W Li  W Z Wu  R B Barbara  K W Schramm  A Kettrup 《Chemosphere》1999,38(14):3313-3318
A new Enzyme ImmunoAssay (EIA) for PCDD/F TEQ measurement in extracts of environmental samples was described. The bioassay TEQ which derived from EIA and EROD were compared with each other and with results from chemical analysis. For all environmental samples, the EROD-TEQ is higher than the value from chemical analysis. However, the EIA-TEQ is much more identical with the value from chemical analysis. Our results indicate that the EIA assay is a complementary method to the EROD assay and should be useful as a rapid and sensitive screening tool for environmental samples in many situations.  相似文献   

4.
The Biobio River basin, located in central Chile, is one of the most important freshwater resources for a population of 1 million inhabitants. The river receives discharges of pulp mills, sewage treatment plants and there is a diffuse input of materials coming from the drainage basin. Previous studies reported high levels of etoxyresorufin-O-deethylase (EROD) induction in fish from the lower stretch of the river, mainly due to polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) exposure. The present study investigates polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzo-furans (PCDFs) levels as well as EROD induction in fish livers from Central Chile's Biobio River. Dioxin and furan levels in fish livers are reported for the first time in three areas of the Basin. In all samples the highest concentrations were found for the octachlorodibenzo-p-dioxin (OCDD) and PCDD/F TEQ concentrations ranged from 2.83 to 6.33 ppt (wet weight). The results indicate a clear induction of EROD activity in different fish species as the river mouth is approached, although this induction is not clearly related with dioxin and furan levels found in the fish livers. Our results clearly show that other pollutants might be acting as EROD inductors in the Biobio Basin.  相似文献   

5.
In this study, the development of a toxicity evaluation method for dioxins in human milk by enzyme-linked immunosorbent assay (ELISA) was reported. A total of 17 human milk samples were tested by ELISA and by gas chromatography/mass spectrometry (GC/MS) to assess whether the ELISA performed on samples obtained from primiparas could be considered as reliable enough for identifying a dioxins contamination in human milk. The concept of toxicity equivalent quantity (TEQ) screening was validated by comparing TEQ values for a set of human milk samples to the ELISA responses predicted for those samples. A fairly good correlation (r=0.920) between immunoassay and GC/MS was achieved for human milk. This ELISA should be useful for biological samples monitoring.  相似文献   

6.
Cunliffe AM  Williams PT 《Chemosphere》2006,62(11):1846-1855
The development of an analytical method for the analysis of PCDD/PCDF in flyash using a bench analytical system comprising of a gas chromatograph fitted with an ion trap detector operated in the tandem MS mode is described. The optimum settings for the most important MS/MS parameters are given, including those for the less reported mono- to tri-chlorinated dioxin and furan congener groups. Flyash samples from three waste incineration plants representing a decommissioned 1970s plant design, an upgraded and still operating plant originally designed in the 1970s, and a modern 1990s design operating plant have been analysed for PCDD/PCDF. The flyash samples were analysed for PCDD/PCDF using the methods developed and the total PCDD/PCDF, I-TEQ values and isomeric profiles are reported. The flyash from the older decommissioned incinerator had very significantly higher concentrations of PCDD/PCDF compared to the modern incinerator flyash.  相似文献   

7.
This study evaluated residual congener patterns of dioxin/furan (=PCDD/DF) related to tactical herbicides aerially sprayed over the regions of southern Vietnam through Operation Ranch Hand. The study focused on Cam Chinh (CC) commune, Quang Tri province (an area sprayed with tactical herbicides), and the Cam Phuc (CP) commune, Ha Tinh province (a non-sprayed area). Breast milk samples for analysis were collected in September 2002 and July 2003 from lactating primiparous and multiparous mothers born after the war (<31 years old). We found the levels of each congener in the CC commune were higher than in the CP commune, and determined specificity in the PCDD/DF congener pattern in CC commune samples by cluster analysis. The congener pattern is characterized by higher (the hexa-, the hepta-, and the octa-) chlorinated PCDD/DFs; this appears to be the same profile as that presented by pentachlorophenol (PCP), rather than 2,4,5-trichlorophenoxy acid (2,4,5-T) contaminated with 2,3,7,8-TCDD. A GC/MS study in the 1970s detected the chlorophenols 2,4-di and 2,4,6-trichlorophenol in some Agent Orange samples, which contained, like PCP, a wide variety of PCDD/DF congeners. In this context, it may be expected that certain tactical herbicides contaminated with various chlorophenol impurities, have a unique congener pattern when compared with pure 2,4,5-T formulations.  相似文献   

8.
The organic toxicants present in the effluent of the main sewer of the city of Zagreb, Croatia were isolated and identified through the use of effects-directed characterisation techniques. At the time of investigation, the wastewater effluent received no treatment and was comprised of a mixture of effluent from domestic and industrial sources. The organic load of the wastewater was isolated by solid phase extraction and toxicity profiles obtained using reverse-phase HPLC. All procedures were evaluated through the analysis of a series of reference compounds of widely differing polarity. Toxicity profiles for EROD activity (CYP1A induction), vitellogenin induction (estrogenic activity), cytotoxicity (membrane stability and metabolic inhibition) were obtained using a rainbow trout (Oncorhynchus mykiss) primary hepatocyte bioassay. The suite of bioassays showed biological responses after exposure to the raw extracts for all the endpoints tested. However, a combination of mixture toxicity and cytotoxicity in the complex raw extract had some masking effect on the sub-lethal responses of vitellogenin and EROD induction. Bioassay testing of the fine fractions obtained by HPLC produced a range of endpoint-specific toxicity profiles for each sample. A number of compounds were identified by the use of GC-MS and LC-MS/MS as responsible for the observed effects. The steroid estrogens 17 beta-estradiol and estriol were identified by LC-MS/MS as estrogen receptor agonists in two of the estrogenic fractions. In addition, GC-MS analysis identified different alkylphenols, benzophenone and methylparaben which also contributed to the estrogenic activity of the sample. Polycyclic aromatic hydrocarbons (PAHs), alkyl substituted PAHs, nitro-polycyclic aromatic compounds (nitro-PACs), carbazoles and alkyl substituted carbazoles and other known CYP1A inducers were identified by GC-MS analysis as responsible for some of the observed EROD activity. Some active compounds remain unidentified.  相似文献   

9.
Within a survey on dioxins in animal fat used as feed ingredient, a sample originating from pigs offal was shown to contain 50 ng Toxic Equivalents (TEQ) PCDD/PCDFs kg(-1) fat. Further investigation revealed fat samples with levels as high as 440 ng TEQ kg(-1) fat and contaminated feed with a highest level of 8.4 ng TEQ kg(-1) feed. The congener pattern was dominated by 1,2,3,7,8-PeCDD and 2,3,7,8-TCDD, and was not recognized from any previous incident or known dioxin source. Remarkably, 2,3,7,8-substituted congeners were much more abundant than their non-2,3,7,8-substituted counterparts. The sampled fat was derived from a gelatin production plant. Broken filters, used to clean the hydrochloric acid (HCl) used in the process, caused the dioxin contamination. The fat was primarily used for pig feed. A new physiologically-based pharmacokinetic (PBPK) model for lipophilic contaminants in growing slaughter pigs predicted levels at slaughter varying between 40 pg TEQ g(-1) fat (worst-case) and 2.5-7pgTEQ g(-1) fat under more realistic scenarios. Almost 300 farms were temporarily blocked. Many fat samples of pigs were analyzed using a combined approach of DR CALUX and GC/HRMS. Levels in contaminated pig fat were around the EU-limit of 1 pg TEQ g(-1) fat, with some samples up to 2-3 pg TEQ g(-1) fat. Of 80 negative samples analyzed by DR CALUX and GC/HRMS no false-negatives were obtained, whereas 36 and 62 of the 80 samples classified suspected with the bioassay had GC/HRMS levels above respectively the tolerance and action limits. It is concluded that novel and unexpected dioxin sources remain a threat to the food chain and require the proper evaluation and monitoring of production processes, including chemicals used therein.  相似文献   

10.
Tris(4-chlorophenyl)methanol (TCP) and tris(4-chlorophenyl)methane (TCPMe) were determined in aquatic organisms and sediment by a method based on Soxhlet extraction, gel permeation chromatography, fractionation over silica and gas chromatography/mass spectrometry (GC/MS) analysis. TCPMe was identified as the 4-substituted isomer after synthesis of this compound. TCP could be determined by GC/MS with negative chemical ionistation (GC/NCI-MS) with a detection limit of 0.02 g kg(-1) and a recovery of 90%. TCP concentrations in marine mammals from the North Sea and Dutch Wadden Sea ranged from 0.2 to 2 mg kg(-1), and those in marine and freshwater fish samples from 0.005 to 0.4 mg kg(-1) on a lipid wt basis. TCP concentrations in two Rhine delta sediment samples were 1.2 and 3.0 microg kg(-1) dry wt, respectively. TCPMe concentrations, determined by GC/MS with electron impact (GC/EI-MS), were 10-50% of the TCP concentration in all samples analysed.  相似文献   

11.
The data on dioxin and furan emissions revealed, based on individual analysis for 2,3,7,8-TCDD, TCDD, 2,3,7,8-TCDF and TCDF for the six test periods and the operation of the two RDF-fired boilers, that there is no apparent consistent relationship between the dioxin and furan emissions and the individual or combined (averaged) boiler steam flow, total flue gas flow, sidewall furnace temperature, furnace temperature at 2-second residence time, or total furnace residence time at this plant. Only RDF feeder balance begins to show a correlation. However, there was a difference between RDF-natural gas firing and RDF-only firing; the RDF-only firing had lower PCDD and PCDF emissions while consistently operating at lower excess air.

The dioxin and furan emissions from this testing are comparable to the low end of the range of these emissions measured by the U.S. EPA at resource recovery plants in the past 4 years. This may be due in part to the calculated average furnace retention of 4 to 5 seconds during Tests #4–6, with average furnace temperatures at 2-second residence time from 1650°F to 1750°F. However, there was no correlation between dioxin and furan emissions in the stack and individual boiler operation, as judged by the average concentrations of O2, CO, CO2, 1-CO/CO2), NOx, HCl, SO2, or TSP, and furnace upset conditions versus normal operation as judged by instantaneous steam flow, sidewall furnace temperature, O2, CO, NOx, or SO2.  相似文献   


12.
A low-cost, high throughput bioanalytical screening method was developed for monitoring cis/trans-permethrin in dust and soil samples. The method consisted of a simple sample preparation procedure [sonication with dichloromethane followed by a solvent exchange into methanol:water (1:1)] with bioanalytical detection using a magnetic particle enzyme-linked immunosorbent assay (ELISA). Quantitative recoveries (83–126 %) of cis/trans-permethrin were obtained for spiked soil and dust samples. The percent difference of duplicate ELISA analyses was within ± 20 % for standards and ± 35 % for samples. Similar sample preparation procedures were used for the conventional gas chromatography/mass spectrometry (GC/MS) analysis except that additional cleanup steps were required. Recoveries of cis/trans-permethrin ranged from 81 to 108 % for spiked soil and dust samples by GC/MS. The ELISA-derived permethrin concentrations were highly correlated with the GC/MS-derived sum of cis/trans-permethrin concentrations with a correlation coefficient (r) of 0.986. The ELISA method provided a rapid qualitative screen for cis/trans-permethrin in soil and dust while providing a higher sample throughput with a lower cost as compared to the GC/MS method. The ELISA can be applied as a complementary, low-cost screening tool to prioritize and rank samples prior to instrumental analysis for exposure studies.  相似文献   

13.
Ma WT  Fu KK  Cai Z  Jiang GB 《Chemosphere》2003,52(9):1627-1632
The excess use of triazine herbicides in agriculture causes severe contamination to the environment especially for ground water. Gas chromatography coupled with mass spectrometry (GC/MS) was used to analyze simazine, atrazine (ATR), cyanazine, as well as the degradation products of ATR such as deethylatrazine and deisopropylatrazine in environmental water samples. These compounds were baseline separated by the established GC method. The water samples were pre-concentrated by solid-phase-extraction (SPE) and analyzed by ion trap MS at sub- to low-ppt levels. Recovery of ATR by the SPE pre-concentration using a C18 cartridge was determined as 90.5 +/- 3.5%. Detection limit of the method using selected ion monitoring technique for ATR was 1.7 ppt when one liter water was analyzed. The relative analytical error for ATR fortified water samples at 200 ppt was -12.5% (n=12) with triple analysis and the relative standard deviation was 3.2%. Trace levels of ATR at 3.9 and 9.7 ppt were determined in water samples collected from a reservoir and a river in Hong Kong.  相似文献   

14.
The variance of polychlorinated dibenzo-p-dioxin (PCDD; dioxin) and polychlorinated dibenzofuran (PCDF; furan) data obtained from single- and simultaneous multiple train methods was compared. Single train triplicate data were used from 4 stack tests obtained from a long dry kiln cement plant and 18 stack tests from a municipal solid waste (MSW) incinerator. Data from the American Society of Mechanical Engineers (ASME) report Reference Method Accuracy and Precision (ReMAP) (Lanier and Hendrix, 2001) were used for the simultaneous multiple samples, which accounted for 27 data points. Nineteen data points were acquired from an ASME research facility, 5 from a MSW incinerator unrelated to the single train MSW incinerator, and 3 from a lightweight aggregate kiln (LWAK). The ReMAP procedure was used to determine the relationship between the standard deviation and the concentration of the single train and simultaneous multiple train data. Results indicated that there was benefit from the use of simultaneous multiple train sampling for concentrations above 129 pg toxic equivalency (TEQ)/m3. There was no indication of benefit from the use of simultaneous multiple train sampling at concentrations below 129 pg TEQ/m3.
Implications:Precision of stack sampling data can be the difference between meeting and failing compliance limits. Generally, three dioxin/furan samples are acquired when stack sampling to meet compliance regulations. A reliable estimation of the data’s true concentration is not possible with this small amount of data. Increasing the precision decreases the chance that the acquired concentration deviates greatly from the true concentration. Facilities that use the appropriate stack sampling method will benefit by either improved data precision or minimal stack sampling expenses. The observations made suggest that facilities that are expected to have dioxin/furan concentrations above 129 pg TEQ/m3 would increase the precision of samples by using simultaneous multiple train sampling.  相似文献   

15.
Computerized methodologies for the quantification of total PCBs, PCB in Aroclor mixtures and individual PCB congeners in environmental samples are presented. The method for total PCBs is based on a multiple-linear regression analysis using data from capillary gas chromatography of Arocolor standards. PCB congeners were identified and their weight percentages determined in Aroclor mixtures by GC/MS. PCB congeners and total PCBs were accurately quantified in predetermined test data and environmental samples.  相似文献   

16.
《Chemosphere》2007,66(11):2244-2252
The identity of compounds responsible for estrogenic and dioxin-like activities in sediment from the harbour of the small town Zierikzee in Zeeland, The Netherlands, was investigated using a bioassay directed fractionation approach with the in vitro estrogen and dioxin responsive reporter gene assays ER- and DR-CALUX. For identification of compounds exhibiting activity in the bioassays, either one or two-dimensional GC in combination with quadrupole (MSD), ion trap (ITD) or time-of-flight mass spectrometric detection (ToF-MS) was used, depending on the biological and chemical characteristics and the complexity of the fractions. The natural estrogenic hormone 17-β-estradiol and its metabolite estrone were identified with GC–ITD as the main contributors to the estrogenic activity. After successive rounds of fractionation, the dioxin-like activity could be explained by the presence of various polycyclic aromatic hydrocarbons identified with GC–MSD and two-dimensional comprehensive GC × GC–ToF-MS. Some estrogenic activity of a relatively non-polar nature remained unidentified.  相似文献   

17.
Xiao R  Wang Z  Wang C  Yu G 《Chemosphere》2006,64(1):71-78
Soil screening could be a process of identifying and defining areas, contaminants, and condition at the sites that warrant further attention for developing ecological risk assessments. In present work, a total of 41 surface soil samples from Tianjin, China were sampled and the soil organic extracts were evaluated using a battery of in vitro cell bioassays. The battery included ethoxyresorfin O-deethylase (EROD) with H4IIE rat hepatoma cells bioassay for Aryl hydrocarbon (Ah) receptor (Ah-agonists) effects, the SOS/umu bioassay for genotoxic effects, and human estrogen receptor recombinant yeast bioassay for estrogenic effects. The results have showed that total estrogenic effects in these soil samples was measured to be between 0.1 and 14.2ng EEQkg(-1) soil (d.w.); Ah-agonists effects assayed by EROD bioassay varied from 2.8ng TEQkg(-1) soil (d.w.) to 42.6ng TEQkg(-1) soil (d.w.), and the amounts of soil weight required for the extracts to lead positive result (IR 2.0) in the SOS/umu bioassay were between 3.9 and 31.3mg (d.w.) per well. In addition, the geographic distributions of Ah-agonists effects and genotoxic effects in Tianjin area exhibited a strong positive correlation with each other. However, the distribution of estrogenic effects with high levels in northwest Tianjin was markedly different from that of Ah-agonists effects, where the high levels were distributed in the urban of Tianjin, as well as coastal towns. It has been concluded that the toxicity assessment of surface soil using a battery of in vitro cell bioassays could provided meaningful information regarding characterization procedure in ecological risk assessment.  相似文献   

18.
Gas chromatographic-mass spectrometric (GC/MS) analysis of particulate matter of the Elbe river and its tributaries Havel, Spree and Mulde revealed a group of three dinaphthylsulfone isomers as sedimentary and suspended particulate matter (SPM) contaminants. The mass spectra of dinaphthylsulfones are characterized by the molecular ion (m/z 318), and the naphthyl fragment ion m/z 127. Losses of HSO(2) and C(10)H(7)O from the molecular ion lead to different mass spectra for each isomer. The gas phase infrared spectra exhibit isomer specific bands in the spectral region between 900 and 700 wave numbers. A synthetic mixture of dinaphthylsulfones was used for isomer identification and the assignment of the gas chromatographic retention behaviour of the dinaphthylsulfone isomers. Quantitative GC/MS analysis of dinaphthylsulfones in 44 sediment and SPM samples provided comprehensive information on the overall distribution and distinct sources of dinaphthylsulfones in the Elbe river drainage system. The results indicate emissions of these compounds over prolonged times and their environmental stability in anaerobic sediments.  相似文献   

19.
PCDTs in the environment   总被引:3,自引:0,他引:3  
Seija Sinkkonen 《Chemosphere》1997,34(12):2585-2594
Polychlorinated dibenzothiophenes (PCDTs) are sulfur analogues of polychlorinated dibenzofurans. Recently, PCDTs have been found in stack gas and fly ash samples, pulp mill effluents, sediments and in some aquatic organisms. PCDTs have been analyzed by high resolution GC/MS and by other GC-MS techniques. Combustion is until now the major known source of PCDTs in the environment. Tri-, tetra- and pentaCDTs in concentrations approaching those of PCDTs have been analyzed in some samples from waste incineration and metal reclamation. Concentrations of PCDTs in pulp mill effluents have been found to be quite low. 2378-TeCDT was found to be the major TeCDT isomer in some pulp mill effluents. Preliminary toxicological investigations have shown that PCDTs possess some kind of dioxin type toxicity.  相似文献   

20.
A simple method for the determination of dimethyl fumarate (DMFu) in silica gel pouches has been developed. The gas chromatographic behaviour of DMFu was investigated; the instrumental method, based on EI mass spectrometry coupled with an Ion Trap Detector operating whether in full scan mode or in MS/MS mode was also investigated. Several factors have been evaluated and optimized during the development process: solvent and temperature of extraction, type of stationary phase in capillary column. The analytical procedure consists of two steps as follows: (a) the sample preparation using 10 g of sample extracted with acetonitrile in an ultrasonic, heated bath and (b) the determination by gas chromatography-ion trap mass spectrometry. Mass spectrometry in conjunction with chromatographic separation is a very powerful combination for identification of an analyte in the extract in spite of selective detectors employed with GC, such as ECD, FPD and NPD, that offer only limited specificity. Blank samples show no interfering peaks in the areas of interest, so the specificity of the method was assured under the investigated GC/MS conditions. The method has been validated in terms of recovery, repeatability, linearity, detection limits and measurement uncertainty. The results obtained meet both the method validation criteria and requirements of the European/National legislation. The method was verified to be accurate with 97 % mean recoveries at 0.05 mg/kg and 1.00 mg/kg levels; the repeatability (expressed as RSD %) was found to be better than 15 %. Good linearity was found in the range between 0.05 μg/mL and 5.0 μg/mL and a value of R2 > 0.9998 was calculated. The procedure ensures high specificity and a good sensitivity with detection limit (ld) of 0.02 mg/kg and quantification limit (LOQ) of 0.05 mg/kg. This procedure has been successfully applied for the analysis of several hundred of real samples collected during a monitoring control plan started last year in our country. All samples exceeding the maximum allowed level of DMFu (0, 1 mg/kg) were confirmed by GC/MS/MS (ITD) for a higher degree of confidence in identification. The main advantages of this method include: rapidity, simplicity (few, simple steps), reliability, cheapness, no need for long and difficult clean-up and evaporation steps, high specificity by using GC/MS and GC/MS/MS, availability for routine monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号