首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
湖南省农田土壤中HCH和DDT残留状况研究   总被引:4,自引:0,他引:4  
2009年6月采集了湖南省农田土壤中的160个样品,采用ASE萃取技术,用GC-MS方法测定了样品中的六六六(HCH)、滴滴涕(DDT)。结果表明:HCH和DDT的检出率为100%,说明湖南省农田土壤中有机氯农药残留现象普遍存在。HCH和DDT的平均含量分别为8.03和36.26μg/kg,范围分别在0.20~17.89μg/kg和5.05~45.96μg/kg。与国内不同区域的同类研究相比,湖南省农田土壤的有机氯残留水平处于中等水平。在不同类型土壤中,有机氯残留状况有所差异,HCH在水稻土中残留量最高,而DDT在棉花田最高。  相似文献   

2.
王伟 《中国环境监测》2019,35(1):135-141
建立了基质固相分散-ASE提取-GC/MS法同时测定土壤中8种有机氯农药和16种多环芳烃的方法。对方法的线性、检出限、精密度、回收率及土壤质控样品进行了分析,结果表明,8种有机氯农药和16种多环芳烃线性良好,相关系数为0.997 5~0.999 8,方法检出限为0.39~1.57μg/kg,空白加标样品的相对标准偏差小于20%,实际土壤样品加标回收率为60.6%~125%,土壤质控样品结果均在范围内。该方法能够满足土壤中8种有机氯农药和16种多环芳烃的检测要求。  相似文献   

3.
用探头式超声波萃取仪、己烷/丙酮混合溶剂提取土壤中的15种Pops类有机氯农药(包括六氯苯、七氯、六六六、氯丹、艾氏剂、狄氏剂、异狄氏剂、灭蚁灵、滴滴涕),萃取溶液经氟罗里硅土柱净化、氮吹浓缩,用气相色谱/质谱仪(GC-MS)进行测定。方法检出限0.4~1.4μg/kg,空白样品有机氯农药加标回收率为52.8%~118%、有机氯标记替代物回收率为71.0%~122%,RSD为6.8%~16.5%。  相似文献   

4.
微波萃取-气相色谱/质谱法测定土壤中的有机氯农药   总被引:11,自引:0,他引:11  
通过微波萃取提取土壤中的有机氯农药,萃取溶液经浓硫酸脱色、佛罗里硅土柱净化,最后用气相色谱/质谱法分析.以石英砂为基体进行加标回收测定,有机氯农药的回收率在75.5%~103%之间,检出限为0.01μg/kg.  相似文献   

5.
建立QuEChERS-气相色谱法同时检测土壤中8种有机氯农药的方法,优化分散固相萃取剂用量。土壤样品通过分散固相萃取净化技术,氮吹浓缩后用正己烷定容,最后通过气相色谱测定。结果表明,在2.0~100μg/L质量浓度范围内呈线性,相关系数r为0.9895~0.9991。空白样品在0.5,5和20μg/kg加标浓度下的回收率为75.3%~92.3%,相对标准偏差为3.2%~5.6%(n=5),方法检出限为0.053~0.064μg/kg,测定下限为0.21~0.26μg/kg。该方法操作简单、结果准确、有机试剂用量少、分析成本低,适用于土壤中有机氯农药的残留检测与分析。  相似文献   

6.
建立了用加速溶剂萃取仪(ASE)萃取、凝胶渗透色谱(GPC)净化、气相色谱/串联四极杆质谱多反应监测、同时测定土壤中17种有机氯农药和19种多氯联苯的方法.加标浓度在3.3μg/kg时的平均回收率在79.6%~93.2%之间,相对标准偏差在2.9%~13.0%之间,定量限在0.01~0.51μg/kg之间.在检测土壤样品中的有机氯农药和多氯联苯残留方面,Gc-QqQ-MS/MS相对于气相色谱/电子捕获检测器(GC-ECD)和GC-MS的选择离子检测(SIM)模式具有非常明显的优势,尤其是在低浓度水平的定性和定量方面.  相似文献   

7.
微波萃取-气相色谱法测定土壤中有机氯残留   总被引:3,自引:0,他引:3       下载免费PDF全文
采用微波萃取-硅镁吸附剂净化-气相色谱法测定土壤中有机氯农药,优化了试验条件。方法线性良好,8种有机氯农药的检出限为0.09ng/g-0.62ng/g,样品测定的RSD为2.6%-13.2%,基质加标平均回收率为93.7%-112%,质控样的测定结果与参考值相吻合。  相似文献   

8.
建立了加速溶剂萃取-气相色谱质谱法同时测定34种有机氯农药(OCPs)和18种多氯联苯类化合物(PCBs)的方法。当取样量为10. 0 g时,52种有机化合物的检出限为0. 03~0. 29μg/kg,以空白样品为基体进行加标回收试验,平均回收率为44. 7%~123. 0%,相对标准偏差(RSD,n=7)为1. 8%~21. 5%。该方法灵敏度高,实现了低浓度有机化合物的定量分析,分析结果准确可靠,满足土壤和沉积物中34种有机氯农药和18种多氯联苯类化合物分析的要求。  相似文献   

9.
建立了用加速溶剂萃取法(ASE)提取、气相色谱-串联质谱法分析土壤中20种有机氯农药的方法。用正己烷和丙酮(1∶1,V/V)的混合溶剂为提取剂,萃取温度100℃,压力1 500 psi,静态提取10 min,循环提取2次,提取液经石墨化碳黑固相萃取柱净化,浓缩后进行GC-MS/MS测定,外标法定量。试验结果表明,采用串联质谱多反应监测模式,降低了背景干扰,当取5 g土壤时,有机氯农药的检出限在0.1~3.0μg/kg之间,低浓度水平(8μg/kg)的基体加标回收率为70.3%~134%,相对标准偏差〈23%。测定方法背景干扰低,灵敏度高,适合土壤中20种有机氯农药残留的同时测定。  相似文献   

10.
采用固相萃取(SPE)技术,结合气相色谱/质谱(GC-MS)选择离子检测法(SIM)对水样中26种有机氯农药(OCPs)进行提取、净化、浓缩前处理,优选了固相萃取小柱填料及萃取、净化条件,优化了GC-MS的工作参数,建立了地下水中26种有机氯农药的SPE-GC-MS分析方法。针对不同的组分,本法加标回收率为76.422%~112.512%,相对标准偏差为4.905%~15.524%,检出限为0.014~0.089μg/L。该方法操作简单,消耗费用低,分析速度快,具有较高的灵敏度和回收率。  相似文献   

11.
萃取技术在环境样品预处理中的应用及发展   总被引:8,自引:0,他引:8  
对萃取技术包括传统技术以及新近发展起来的如固相萃取、固相微萃取、膜萃取、超临界流体萃取、微波萃取等技术在环境样品预处理方面的运用进行综述,分析各自的优缺点以及发展前景.  相似文献   

12.
The leaching tests, including the Toxicity Characteristic Leaching Procedure (TCLP), EDTA extraction and BCR sequential extractions before and after EDTA treatments, were performed on two specific soils to elucidate heavy metal-associated mineral fractions and general leachability. The TCLP illustrated the low leachability of heavy metals in soils from two sites. EDTA is a strong chelator and therefore had higher extraction efficiency compared to that of TCLP. The lower extraction percentages by EDTA for As and Sb were found compared to the other heavy metals derived from anthropogenic sources. Sequential extractions showed that the importance of acid-extractable, organically-bound and Fe–Mn oxide fractions was identified for anthropogenic heavy metals with the exception of As and Ni while the importance of residual fraction was identified for endogenous metals. Changes in sequential fractions of heavy metals after leaching with EDTA are very complex and it is difficult to generalize on which fraction was more mobile than the others. These combined results are helpful in elucidating the association of heavy metals to soil fractions and the mobility characteristics of heavy metals under certain environmental conditions.  相似文献   

13.
研究了用超声波萃取城市污水处理厂污泥中动植物油和矿物油的方法,并与索氏提取法进行比较.结果表明,超声波萃取法对污泥中矿物油和动植物油测定操作简单快速,标样回收率高,精密度好.  相似文献   

14.
ASE萃取-SPE净化- HPLC法测定土壤中多环芳烃   总被引:5,自引:0,他引:5       下载免费PDF全文
建立了加速溶剂萃取-固相萃取净化-高效液相色谱测定土壤中16种多环芳烃的方法,优化了试验条件.方法线性关系良好,16种多环芳烃的检出限在0.412 ng/g~3.974 ng/g之间,空白加标试验的相对标准偏差在1.2%~12.7%之间,基质加标回收率在60.4%~126%之间.实际样品的测定结果表明该方法分离效果好,能够满足土壤分析的要求.  相似文献   

15.
探讨了利用液相色谱分离,荧光检测器测定地表水中联苯胺的可行性。前处理方法对比验证了液液萃取法和固相萃取法。水样在碱性条件下(pH=11~12)进行提取,当提取体积为1.0 L时,液液萃取液相色谱荧光法检测,方法检出限为1.4 ng/L,定量下限为5.5 ng/L;固相萃取液相色谱荧光法检测,方法检出限为0.9 ng/L,定量下限为3.6 ng/L。分别对地表水、生活废水、工业废水3种不同水体进行基体加标试验,加标浓度为10.0、40.0、80.0 ng/L。结果显示,对于3种不同基体和不同加标浓度的水样,两种方法均有较好的准确性和重现性,方法回收率为80%~120%,相对标准偏差均小于20%,满足《地表水环境质量标准》(GB 3838—2002)中对联苯胺的监测需求。  相似文献   

16.
研究了加速溶剂萃取(ASE)、固相萃取柱净化(SPE)、高效液相色谱仪(HPLC)联合测定土壤中16种多环芳烃(PAHs)的分析方法,选择以正己烷/丙酮(1+1,V/V)作为ASE提取溶剂,提取液经SPE硅胶小柱净化,正己烷/二氯甲烷(1+1,V/V)进行洗脱,洗脱体积为10 m L,洗脱液经旋转蒸发浓缩至近干,过0.22μm有机滤膜,用乙腈定容至1 m L,最后用HPLC-紫外检测器对提取液中16种PAHs进行定量分析。土壤中16种PAHs的方法检出限为2.8~4.9μg/kg,加标回收率为81.9%~102%,相对标准偏差为2.5%~6.2%,完全满足土壤中PAHs分析的质量控制要求,该法稳定性好、准确度高、可操作性强,适合于土壤样品中16种PAHs的准确测定。  相似文献   

17.
快速溶剂萃取红外分光光度法测定土壤中石油类   总被引:2,自引:1,他引:1  
研究快速溶剂萃取红外分光法对土壤中石油类的提取效果,并与超声波萃取红外分光法比较.结果表明,快速溶剂萃取对土壤中的石油类的回收率高,精密度好,方法快速简便.  相似文献   

18.
对研磨法和超声法测定浮游植物中的叶绿素a进行了比较。结果表明,超声法对浮游植物叶绿素a的萃取效率优于研磨法,人为误差小,精密度较高,且简便安全,适宜推广应用。  相似文献   

19.
气相色谱法测定水中环氧氯丙烷的方法比较研究   总被引:2,自引:0,他引:2  
通过顶空-气相色谱法与液-液萃取法测定水中环氧氯丙烷的方法比较研究,结果表明两种方法均能满足地表水环境质量标准的检测要求。但静态顶空法在检出限、回归曲线相关系数、样品加标回收率、相对标准偏差等方面均优于液-液萃取法,且静态顶空法操作简便、快捷,方法准确可靠、灵敏度高、重现性好,在水环境分析监测中具有实用性。  相似文献   

20.
区域土壤中氯苯类化合物测定及分布研究   总被引:1,自引:0,他引:1  
以区域内16个土壤样品为研究对象,采用超声波萃取法对样品中的氯苯类污染物进行提取,并用气相色谱仪分类和测定,以保留时间定性,外标法定量。结果表明,利用超声波提取土壤中氯苯类是可行的,并能够进行分类检出;预处理中提取的最佳、合理的溶剂为正己烷;实验还得出了11种氯苯类化合物在18min内全部流出的最佳色谱条件。检测数据显示区域土壤内主要氯苯类污染物为二氯苯、四氯苯和六氯苯。  相似文献   