首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study was designed to find the effects of two kinds of dust-free garments with (A) and without (B) frozen gel strip (FGS), and half-naked clothing (brassiere and shorts; C) on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperatures as well as sweat rate and clothing microclimate were measured during 140 min in 9 healthy females. Inquiries were also made into the subjective rating of thermal, humidity, and comfort sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal and skin temperatures (chest and forehead), heart rate, and sweat rate were clearly lowest in garb C, intermediate in garb A, and highest in garb B throughout the experiment; (b) Temperature and humidity within clothing were lower in garb A than in garb B; (c) More than half of the 9 participants decreased thermal sensation by wearing garb A. These results suggest that the usage of FGS could improve the heat load in lightly working participants wearing dust-free garments.  相似文献   

2.
The aim of the study was to identify whether a ventilation cooling shirt was effective in reducing heat strain in a hot climate. Eight female volunteers were exposed to heat (38?°C, 45% relative humidity) for 2?h with simulated office work. In the first hour they were in normal summer clothes (total thermal insulation 0.8?clo); in the second hour a ventilation cooling shirt was worn on top. After the shirt was introduced for 1?h, the skin temperatures at the scapula and the chest were significantly reduced (p?<?0.05). The mean skin and core temperatures were not reduced. The subjects felt cooler and more comfortable by wearing the shirt, but the cooling effect was most conspicuous only during the initial 10?min. The cooling efficiency of the ventilation shirt was not very effective under the low physical activity in this hot climate.  相似文献   

3.
The heat transferred through protective clothing under long wave radiation compared to a reference condition without radiant stress was determined in thermal manikin experiments. The influence of clothing insulation and reflectivity, and the interaction with wind and wet underclothing were considered. Garments with different outer materials and colours and additionally an aluminised reflective suit were combined with different number and types of dry and pre-wetted underwear layers. Under radiant stress, whole body heat loss decreased, i.e., heat gain occurred compared to the reference. This heat gain increased with radiation intensity, and decreased with air velocity and clothing insulation. Except for the reflective outer layer that showed only minimal heat gain over the whole range of radiation intensities, the influence of the outer garments’ material and colour was small with dry clothing. Wetting the underclothing for simulating sweat accumulation, however, caused differing effects with higher heat gain in less permeable garments.  相似文献   

4.
The purpose of this study was to investigate the effect of moisture on the heat transfer through clothing in relation to the water vapour resistance, type of underwear, location of the moisture and climate. This forms part of the work performed for work package 2 of the European Union THERMPROTECT project. Thermal manikin results of dry and wet heat loss are presented from different laboratories for a range of 2-layer clothing with similar dry insulations but different water vapour permeabilities and absorptive properties. The results obtained from the different manikins are generally consistent with each other. For each climate, total wet heat loss is predominately dependent on the permeability of the outer layer. At 10 degrees C, the apparent evaporative heat loss is markedly higher than expected from evaporation alone (measured at 34 degrees C), which is attributed to condensation within the clothing and to increased conductivity of the wet clothing layers.  相似文献   

5.
Mine rescuers’ heat load under the same physical effort load (25% of the maximal oxygen uptake), using three types of breathing apparatus, in newly developed heat-removing underwear and outerwear was assessed for typical work conditions of mine rescuers, under milder and harsher ambient conditions of 32 and 38?°C, respectively, both at relative humidity of 85% and air velocity of 1.0?m/s. Expending physical effort at the same load while using different kinds of breathing apparatus resulted in a similar heat load. Under both milder and harsher ambient conditions, heat storage and sweating intensity were greater than the average limit value recommended by hygienic standards, which indicates that the use of breathing apparatus significantly hinders heat exchange with the environment. The developed clothing for mine rescuers was highly rated, and was considered by most people to be better than that used currently.  相似文献   

6.
The purpose of this study was to determine the usefulness of physiological studies in the evaluation of protective clothing for work in a cold environment. The study included the examination of the dynamics of changes in chosen physiological parameters (core and skin temperatures, heart rate, pulmonary minute ventilation) as well as physical ones (the temperature and relative humidity under the clothes) during work in protective clothing with unknown thermal insulation. The experiment was conducted in extreme environmental conditions (–10 and –15°C) at a work load defined by the clothing manufacturer as moderate. Results show that thermal equilibrium was achieved and maintained throughout the investigated work time (60 min) and that the protective clothing ensures safety on the time scale of a regular 8-hour work day. It was also shown that the dynamics of thermal stress physiological parameters can be used to determine the maximum duration of exposure for cold protective clothing with unknown thermal insulation.  相似文献   

7.
Introduction. Cooling of the body is used to treat hyperthermic individuals with heatstroke or to depress core temperature below normal for neuroprotection. A novel, chemically activated, unpowered cooling device, CAERvest®, was investigated for safety and efficacy. Methods. Eight healthy male participants (body mass 79.9?±?1.9?kg and body fat percentage 16.1?±?3.8%) visited the laboratory (20 °C, 40% relative humidity) on four occasions. Following 30-min rest, physiological and perceptual measures were recorded. Participants were then fitted with the CAERvest® proof of concept (PoC) or prototype 1 (P1), 2 (P2) or 3 (P3) for 60 min. Temperature, cardiovascular and perceptual measures were recorded every 5 min. After cooling, the CAERvest® was removed and the torso checked for cold-related injuries. Results. Temperature measures significantly (p?Conclusion. This study demonstrates that the CAERvest® is an effective device for reducing body temperature in healthy normothermic individuals without presence of cold injury. Further research in healthy and clinical populations is warranted.  相似文献   

8.
利用出汗暖体假人Walter对换气式降温服的冷却性能进行评价,通过穿着降温服前后对假人皮表温度、衣内湿度、输出功率测试数据对比,结果表明在环境温度40℃以下相对湿度55%的条件下,穿着降温服皮表温度维持在36℃,衣内相对湿度维持在60%左右,制冷量在100w~170w,能够满足工作人员从事中等体力型活动,具有很好的应用价值。  相似文献   

9.
本文对不同隔热层材料组成的消防服的热防护性能进行了实验测试与分析验证,评价了新型组合式消防服和传统组合式消防服的隔热性能优劣。结果表明以SiO2气凝胶材料为隔热层的新型组合式消防服的导热系数约为传统型的1/4,具有更显著的热防护效果。  相似文献   

10.
11.
Five students of a rescue training school cycled at 50 W for 20 min at 20 °C before walking at 5 km/hr up to 30 min in a climatic chamber at 55 °C and 30% relative humidity. 4 different types of clothing ensembles differing in terms of thickness and thermal insulation value were tested on separate days. All subjects completed 28–30 min in light clothing, but quit after 20–27 min in 3 firefighter ensembles due to a rectal temperature of 39 °C or subjective fatigue. No difference in the evolution of mean skin or rectal temperature was seen for the 3 turnout ensembles. Sweat production amounted to about 1000 g in the turnout gears of which less than 20% evaporated. It was concluded that the small differences between the turnout gears in terms of design, thickness and insulation value had no effect on the resulting heat physiological strain for the given experimental conditions.  相似文献   

12.
Five students of a rescue training school cycled at 50 W for 20 min at 20 degrees C before walking at 5 km/hr up to 30 min in a climatic chamber at 55 degrees C and 30% relative humidity. 4 different types of clothing ensembles differing in terms of thickness and thermal insulation value were tested on separate days. All subjects completed 28-30 min in light clothing, but quit after 20-27 min in 3 firefighter ensembles due to a rectal temperature of 39.0 degrees C or subjective fatigue. No difference in the evolution of mean skin or rectal temperature was seen for the 3 turnout ensembles. Sweat production amounted to about 1000 g in the turnout gears of which less than 20% evaporated. It was concluded that the small differences between the turnout gears in terms of design, thickness and insulation value had no effect on the resulting heat physiological strain for the given experimental conditions.  相似文献   

13.
Wildland firefighters work in unfavourable environments involving both heat and moisture. Moisture in clothing systems worn by wildland firefighters may increase or decrease heat transfer, depending on its source and location in the clothing system, location on the body, timing of application and degree of sorption. In this experiment, 4 outerwear/underwear combinations were exposed to 1 of 5 different conditions varying on amount and location of moisture. The fabric systems were then exposed to either a high-heat-flux flame exposure (83 kW/m(2)) or a low-heat-flux radiant exposure (10 kW/m(2)). Under high-heat-flux flame exposures, external moisture tended to decrease heat transfer through the fabric systems, while internal moisture tended to increase heat transfer. Under low-heat-flux radiant exposures, internal moisture decreased heat transfer through the fabric systems. The nature and extent of such differences was fabric dependent. Implications for test protocol development are discussed.  相似文献   

14.
本文通过对防弹衣的改进研究,探讨了利用经编间隔织物对防弹装备舒适性提高的可行性。用经编间隔织物代替传统防弹衣里料(平纹机织布),并制成成衣。通过红外热成像仪分别测试以经编间隔织物为里料的防弹衣的热湿传导性、透气散热性来探讨经编间隔织物对防弹衣的舒适性能的影响。实验结果表明:在相同测试条件下,以经编间隔织物为里料的防弹衣的热湿传导性能良好,透气散热性优于传统防弹衣1℃左右。因此经编间隔织物对提高防弹衣的舒适性能具有推动作用。本课题的研究意义在于为警用防弹衣的舒适性能提供理论参考,为警察或军队的作战能力提高做出更大的贡献。  相似文献   

15.
Heat stress on workers working outdoors in the power industry may result in fatigue and deterioration in task performance. This research collected and analyzed data on task performance of workers working indoors and outdoors with and without a cooling suit. The task performance was compared on the basis of heart rate, oxygen consumption, tympanic temperature, subjective responses, productivity, and error rates. Based on One-Way Analysis Of Variance (ANOVA) results, a significantly lower estimated working oxygen consumption was observed (p < .001) when the cooling suit was worn. The productivity was higher while workers wore the cooling suit as compared to no cooling suit (p = .011) whereas the error rates were significantly lower(p < .001). Also a significantly lower self-reported discomfort was observed in the neck and shoulders while working wearing the cooling suit (p = .004). This study concluded that wearing a cooling suit while working outdoors was associated with physiological benefits as well as improved task performance of the study participants.  相似文献   

16.
Heat stress on workers working outdoors in the power industry may result in fatigue and deterioration in task performance. This research collected and analyzed data on task performance of workers working indoors and outdoors with and without a cooling suit. The task performance was compared on the basis of heart rate, oxygen consumption, tympanic temperature, subjective responses, productivity, and error rates. Based on One-Way Analysis Of Variance (ANOVA) results, a significantly lower estimated working oxygen consumption was observed (p < .001) when the cooling suit was worn. The productivity was higher while workers wore the cooling suit as compared to no cooling suit (p = .011) whereas the error rates were significantly lower (p < .001). Also a significantly lower self-reported discomfort was observed in the neck and shoulders while working wearing the cooling suit (p = .004). This study concluded that wearing a cooling suit while working outdoors was associated with physiological benefits as well as improved task performance of the study participants.  相似文献   

17.
The suitability of the IREQ (insulation required) index for predicting the thermal responses of 6 participants wearing chemical protective clothing was tested during exercise at -20 and -25 °C. IREQ was used to calculate duration limited exposure (DLE). Measured DLE correlated (r= .899, p < .001) with the predicted DLE. In exposures exceeding 40 min, however, the predicted DLE tended to be 10-20 min too short compared to the measured one. During short exposures the prediction was 5-20 min too long. The results show that IREQ overestimated the cold strain in participants wearing chemical protective clothing during cold exposures longer than 40 min. Nevertheless, predicted DLE never exceeded measured times and thus the prediction was always safe from the occupational point of view.  相似文献   

18.
为量化环境条件对消防服热舒适性能的影响,选取我国02式消防服,测量其在不同环境温度、湿度及风速条件下的热阻和湿阻并得出拟合公式;通过回归分析法分析环境条件对热阻和湿阻的影响,提出其对热阻和湿阻影响的数学模型。结果表明:风速对热阻和湿阻的影响较大,而环境温度和湿度对热阻及湿阻的影响较少;风速与整体热阻及整体湿阻呈负相关,而风速与固有热阻和固有湿阻呈正相关。该研究可为消防服热舒适性能测试及高性能防护装备研发提供理论指导。  相似文献   

19.
本文描述了一种新型消防员隔热防护服的外层面料。面料的结构由铝箔、聚酯膜和基布组成。通过对铝箔复合、涂胶等加工方法的摸索试验,试制了新型消防员隔热防护服的外层面料。  相似文献   

20.
Personal cooling garments (PCGs) have gained increased attention in recent years due to heat stress and strain in the working environment. The present study was conducted in hot environments of an iron foundry to evaluate the efficacy of a battery-operated PCG. Twenty-four workers were exposed to climatic conditions of 35.89?±?1.25?°C, 35% relative humidity during 90-min work with PCG and habitual clothing (HC). Mean weighted skin temperature was significantly lower by 4.84?±?1.05?°C compared with HC 0.38?±?1.02?°C (p?p?相似文献   