首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 505 毫秒
1.
The aim of the study was to examine the effects of wearing an ice-vest (ca 1 kg) on physiological and subjective responses in fire fighters. The experiments were carried out on a treadmill in a hot-dry environment. The physical cooling effect of the ice-vest was measured with a thermal manikin. The ice-vest effectively reduced skin temperatures under the vest. On average, heart rate was 10 beats/min lower, the amount of sweating was reduced by 13%, and subjective sensations of effort and warmth were lower during work with the ice-vest compared to work without it. Thermal manikin tests indicated that the useful energy available from the vest for body cooling was rather high (58%). In conclusion, the ice-vest reduces physiological and subjective strain responses during heavy work in the heat, and may promote efficient work time by 10%.  相似文献   

2.
Objective. The provision of appropriate personal cooling vests is recognized as an effective measure to combat heat stress. However, personal cooling vests are not widely implemented in the Hong Kong industries. The current study aims to evaluate the usability of a hybrid cooling vest that is associated with the success of its application in industrial settings. Methods. A self-administrated questionnaire focusing on 10 subjective attributes of cooling effect, ergonomic design and usability of a hybrid cooling vest was administered with 232 occupational workers in the construction, horticultural and cleaning, airport apron services and kitchen and catering industries. Results. A structural equation model estimated by analysis of moment structures was constructed to evaluate the usability of the cooling vest, as influenced by cooling effect and ergonomic design. Results showed that cooling effect (path coefficient?=?0.69, p?p?Conclusions. The structural equation model is feasible to examine the complex nature of the structural relationships among the subjective perceptions of personal cooling vests. The empirical findings furnish sound evidence for further optimization of the hybrid cooling vest in terms of cooling effect and ergonomic design for occupational workers.  相似文献   

3.
本文目的是评价降温背心的降温效果。通过对3名成年人在不同环境条件下,分别穿着降温背心和普通服装,测量人员胸部、上肢、下肢和直肠温度的变化,同时监测心率、呼吸和出汗量等,得出环境温度越高,降温背心的降温效果越明显;体形胖的人耐热能力相对差;耐热与出汗量密切相关等结论,并指出降温背心的降温效果显著,能够满足高温岗位的需要。  相似文献   

4.
Heat stress on workers working outdoors in the power industry may result in fatigue and deterioration in task performance. This research collected and analyzed data on task performance of workers working indoors and outdoors with and without a cooling suit. The task performance was compared on the basis of heart rate, oxygen consumption, tympanic temperature, subjective responses, productivity, and error rates. Based on One-Way Analysis Of Variance (ANOVA) results, a significantly lower estimated working oxygen consumption was observed (p < .001) when the cooling suit was worn. The productivity was higher while workers wore the cooling suit as compared to no cooling suit (p = .011) whereas the error rates were significantly lower(p < .001). Also a significantly lower self-reported discomfort was observed in the neck and shoulders while working wearing the cooling suit (p = .004). This study concluded that wearing a cooling suit while working outdoors was associated with physiological benefits as well as improved task performance of the study participants.  相似文献   

5.
Heat stress on workers working outdoors in the power industry may result in fatigue and deterioration in task performance. This research collected and analyzed data on task performance of workers working indoors and outdoors with and without a cooling suit. The task performance was compared on the basis of heart rate, oxygen consumption, tympanic temperature, subjective responses, productivity, and error rates. Based on One-Way Analysis Of Variance (ANOVA) results, a significantly lower estimated working oxygen consumption was observed (p < .001) when the cooling suit was worn. The productivity was higher while workers wore the cooling suit as compared to no cooling suit (p = .011) whereas the error rates were significantly lower (p < .001). Also a significantly lower self-reported discomfort was observed in the neck and shoulders while working wearing the cooling suit (p = .004). This study concluded that wearing a cooling suit while working outdoors was associated with physiological benefits as well as improved task performance of the study participants.  相似文献   

6.
矿用降温服的研制与应用对于解决矿山人员的防暑降温具有重要意义。本文介绍了矿用降温服的工作原理及设计方案,并对矿用降温服的热舒适性进行理论研究和现场试验。结果表明:矿用降温服所采用蓄冷材料的相变温度为-4.6℃,相变潜热为255.1J/g。该矿用降温服具有良好的降温效果和热舒性。  相似文献   

7.
利用出汗暖体假人Walter对换气式降温服的冷却性能进行评价,通过穿着降温服前后对假人皮表温度、衣内湿度、输出功率测试数据对比,结果表明在环境温度40℃以下相对湿度55%的条件下,穿着降温服皮表温度维持在36℃,衣内相对湿度维持在60%左右,制冷量在100w~170w,能够满足工作人员从事中等体力型活动,具有很好的应用价值。  相似文献   

8.
The aim of the study was to identify whether a ventilation cooling shirt was effective in reducing heat strain in a hot climate. Eight female volunteers were exposed to heat (38?°C, 45% relative humidity) for 2?h with simulated office work. In the first hour they were in normal summer clothes (total thermal insulation 0.8?clo); in the second hour a ventilation cooling shirt was worn on top. After the shirt was introduced for 1?h, the skin temperatures at the scapula and the chest were significantly reduced (p?<?0.05). The mean skin and core temperatures were not reduced. The subjects felt cooler and more comfortable by wearing the shirt, but the cooling effect was most conspicuous only during the initial 10?min. The cooling efficiency of the ventilation shirt was not very effective under the low physical activity in this hot climate.  相似文献   

9.
According to the European prestandard ENV 342:1998, the thermal insulation of cold-protective clothing is measured with a thermal manikin. Systematic studies on the reproducibility of the values, measured with different types of clothing on the commonly used standing and walking manikins, have not been reported in the literature. Over 300 measurements were done in 8 different European laboratories. The reproducibility of the thermal insulation test results was good. The coefficient of variation was lower than 8%. The measured clothing should fit the manikin precisely, because poorly fitting clothing gave an error in the results. The correlation between parallel and serial insulation values was excellent and parallel values were about 20% lower than serial ones. The influence of ambient conditions was critical only in the case of air velocity. The reproducibility of thermal insulation test results in a single laboratory was good, and the variation was lower than 3%.  相似文献   

10.
The purpose of this study was to determine if the advantages and disadvantages of a new automotive seating concept, known as the micro-adjuster control system, could be reliably evaluated using both a physiological assessment technique (i.e., electromyography [EMG]) and a subjective questionnaire. The results indicate that psychophysical measures of discomfort and the root mean squared (RMS) activity of the EMG are statistically related, r (8) = ?.788, p = .020. More specifically, subjective perceptions of comfort were found to improve with decreasing levels of muscle activity. This implies that seat comfort can be evaluated on the basis of physiological as well as subjective responses to prolonged driving. This finding should drastically improve automobile seat design efforts.  相似文献   

11.
Personal cooling garments (PCGs) have gained increased attention in recent years due to heat stress and strain in the working environment. The present study was conducted in hot environments of an iron foundry to evaluate the efficacy of a battery-operated PCG. Twenty-four workers were exposed to climatic conditions of 35.89?±?1.25?°C, 35% relative humidity during 90-min work with PCG and habitual clothing (HC). Mean weighted skin temperature was significantly lower by 4.84?±?1.05?°C compared with HC 0.38?±?1.02?°C (p?p?相似文献   

12.
Research into newly developed ballistic vests to be worn by police officers under clothing was carried out with air temperature conditions of +20 °C. A ballistic vest should incorporate protective features, comfort and ergonomics. The thermal strain on users who wore the vests was evaluated as an average and individually, after they had been conditioned in high (+50 °C), low (?40 °C) or neutral (+20 °C) air temperatures, while performing various occupational activities. Research involved six police officers aged 36–42 years, who wore civilian clothing used in moderate environmental conditions. During the tests, physiological parameters (internal temperature, local skin temperatures and amount of sweat secreted) were determined. The ease of doing exercises while wearing the vests, vest service and level of discomfort in use were assessed. Research showed that the vests tested, both as an average and individually, meet the requirements of Standard No. PN-V-87000:2011 (clause 4.5).  相似文献   

13.
Phase-change materials (PCM) can be used to reduce thermal stress and improve thermal comfort for workers wearing protective clothing. The aim of this study was to investigate the effect of PCM in protective clothing used in simulated work situations. We hypothesized that it would be possible to optimize cooling performance with a design that focuses on careful positioning of PCM, minimizing total insulation and facilitating moisture transport. Thermal stress and thermal comfort were estimated through measurement of body heat production, body temperatures, sweat production, relative humidity in clothing and subjective ratings of thermal comfort, thermal sensitivity and perception of wetness. Experiments were carried out using 2 types of PCM, the crystalline dehydrate of sodium sulphate and microcapsules in fabrics. The results of 1 field and 2 laboratory experimental series were conclusive in that reduced thermal stress and improved thermal comfort were related to the amount and distribution of PCM, reduced sweat production and adequate transport of moisture.  相似文献   

14.
Fire fighters are normally overprotected during their working hours because of the tendency to keep the personal protection level sufficiently high in case of the worst possible scenarios. This study investigated the effects of task-fitted protective clothing on thermal strain in fire fighters as compared to EN 469:2005 protective clothing during a prolonged (2 1/2 hrs) job-related rescue drill under neutral and hot climates. The subjects were 23 healthy, physically fit professional male fire fighters aged 26–44 years. Measurements included cardiovascular and thermal responses and subjective assessments. Wearing task-fitted clothing during rescue tasks in a neutral climate considerably reduced total thermal and cardiovascular strain in prolonged rescue work. The fire fighters also perceived physical work as significantly harder on average, and reported more intense subjective discomfort while wearing EN 469:2005 as compared to task-fitted clothing.  相似文献   

15.
Fire fighters are normally overprotected during their working hours because of the tendency to keep the personal protection level sufficiently high in case of the worst possible scenarios. This study investigated the effects of task-fitted protective clothing on thermal strain in fire fighters as compared to EN 469:2005 protective clothing during a prolonged (2 1/2 hrs) job-related rescue drill under neutral and hot climates. The subjects were 23 healthy, physically fit professional male fire fighters aged 26-44 years. Measurements included cardiovascular and thermal responses and subjective assessments. Wearing task-fitted clothing during rescue tasks in a neutral climate considerably reduced total thermal and cardiovascular strain in prolonged rescue work. The fire fighters also perceived physical work as significantly harder on average, and reported more intense subjective discomfort while wearing EN 469:2005 as compared to task-fitted clothing.  相似文献   

16.
This study was a joint physiological and psychological experiment undertaken to determine changes in physiological and psychological human functions under the combined influence of heat, noise, and physical activity. Seven experimental situations were simulated in a climatic chamber with different configurations of three independent variables: heat (40 °C), noise (98 dB), and physical effort (30% of maximum volume of oxygen uptake—V02 max). Five psychological variables (critical flicker fusion—CFF, hand tremor, reaction time, subjective climate evaluation, and subjective evaluation of the given condition load) and two physiological variables (heart rate and rectal temperature) were monitored. Results indicate that CFF changed (increased) significantly when more than one experimental variable was applied. These changes coincided with significant changes in both subjective climate evaluation and subjective evaluation of a given condition load. There were no significant changes in psychomotor functions (hand tremor and reaction time). None of the observed physiological parameters were above the critical value. The results suggest that CFF can be treated as a psychophysical load indicator.  相似文献   

17.
Diagnosis and monitoring are the major tasks of an operator in main control room of nuclear power plants (NPPs). The operator’s mental workload influences his/her performance, and furthermore, affects the system safety and operations. This study investigated the operator’s mental workload and work performance of the NPP in Taiwan. An experiment including primary and secondary tasks was designed to simulate the reactor shutdown procedure of the fourth nuclear power plant (FNPP). The performance of the secondary tasks (error rate), subjective mental workload (NASA Task Load Index, NASA-TLX) as well as seven physiological indices were assessed and measured. The group method of data handling (GMDH) was applied to integrate these physiological indices to develop a work performance predictive model. The validity of the proposed model is very well with R2 = 0.84 and its prediction capability is high (95% confidence interval). The proposed model is expected to provide control room operators a reference value of their work performance by giving physiological indices. Besides NPPs, the proposed model can be applied to many other fields, e.g. aviation, air transportation control, driving and radar vigilance, etc.  相似文献   

18.
This job-related experiment investigated physiological strain in subjects wearing impermeable chemical protective suit systems (CPSSs) weighing about 28 kg. Two types of CPSSs were studied: the self-contained breathing apparatus was carried either inside or outside the suit. Eight healthy and physically fit male firefighter instructors aged 32 to 45 years volunteered for the study. The test drill, performed at a dry, windless ta of 40 degrees C, was divided into 2 consecutive work sessions of 14.5 min (a 20-min rest between) including typical operational work tasks. Considerable thermal and maximal cardiovascular strain and intense subjective discomfort measured in the firefighters emphasize the need to limit working time in hot conditions to only 10-12 min while wearing CPSSs. The present results indicate that the exceptionally heavy physical load and psychological stress during operations in chemical emergencies must be considered in the assessment of the cardiovascular capacity of ageing firefighters using CPSSs.  相似文献   

19.
Cold protective clothing was studied in 2 European Union projects. The objectives were (a) to examine different insulation calculation methods as measured on a manikin (serial or parallel), for the prediction of cold stress (IREQ); (b) to consider the effects of cold protective clothing on metabolic rate; (c) to evaluate the movement and wind correction of clothing insulation values.

Tests were carried out on 8 subjects. The results showed the possibility of incorporating the effect of increases in metabolic rate values due to thick cold protective clothing into the IREQ model. Using the higher thermal insulation value from the serial method in the IREQ prediction, would lead to unacceptable cooling of the users. Thus, only the parallel insulation calculation method in EN 342:2004 should be used. The wind and motion correction equation (No. 2) gave realistic values for total resultant insulation; dynamic testing according to EN 342:2004 may be omitted.  相似文献   

20.
Cold protective clothing was studied in 2 European Union projects. The objectives were (a) to examine different insulation calculation methods as measured on a manikin (serial or parallel), for the prediction of cold stress (IREQ); (b) to consider the effects of cold protective clothing on metabolic rate; (c) to evaluate the movement and wind correction of clothing insulation values. Tests were carried out on 8 subjects. The results showed the possibility of incorporating the effect of increases in metabolic rate values due to thick cold protective clothing into the IREQ model. Using the higher thermal insulation value from the serial method in the IREQ prediction, would lead to unacceptable cooling of the users. Thus, only the parallel insulation calculation method in EN 342:2004 should be used. The wind and motion correction equation (No. 2) gave realistic values for total resultant insulation; dynamic testing according to EN 342:2004 may be omitted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号