首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 156 毫秒
1.
供水管网中微生物生长和生物膜形成可对管网水质和运行造成重要影响.利用MPN-Griess方法检测了上海某供水系统生物膜中氨氧化细菌的数量,分析了管网中氨氧化细菌与管网水中硝化作用和消毒剂之间的相关性.通过室内实验分析了氨氧化细菌和异养菌对氯胺消毒剂的抗性和消耗影响.结果表明,管网中氨氧化细菌数量(以生物膜干重计)在1.0×102~4.3×105 MPN/g之间,与氨氮、亚硝酸盐氮和硝酸盐氮浓度的相关系数分别为-0.563、 0.603和-0.563;与总氯和一氯胺浓度的相关系数分别是-0.659和-0.571.氨氧化细菌对氯胺消毒剂的抗性明显高于异养菌,对氯胺消毒剂的消耗能力也强于异养菌.  相似文献   

2.
BTMT生物膜载体对厌氧氨氧化反应器启动的影响   总被引:1,自引:0,他引:1       下载免费PDF全文
采用两套厌氧氨氧化反应器R1和R2,研究了BMTM生物膜载体对厌氧氨氧化工艺启动特性的影响.结果表明,R1采用UASB反应器启动厌氧氨氧化反应器,经140d运行,对氨氮和亚硝酸盐氮的去除率仅达到54.6%和58.8%,氨氮与亚硝酸盐氮去除负荷之和仅为0.09kg/(m3×d),随后,向其上部投加0.6L BMTM载体,经过26d运行,氨氮及亚硝酸盐氮去除率分别迅速提升至92.5%和97.4%,R1的启动速度较之前有明显提高;R2采用BMTM载体启动上流式填料床生物膜反应器厌氧氨氧化工艺,经过83d的运行,氨氮及亚硝酸盐氮去除率分别达到83.6%和89.4%,氨氮与亚硝酸盐氮去除负荷之和达0.22kg/(m3×d),启动速度较R1大幅提高.  相似文献   

3.
强化启动对内循环生物流化床硝化效果的影响   总被引:1,自引:0,他引:1       下载免费PDF全文
通过改变内循环生物流化床的启动水质,提高N/C组成以强化流化床后期的硝化作用.结果表明,高N/C和低进水COD强化启动后处理生活污水,在HRT为2h时,可以同时高效去除COD和氨氮,氨氮的平均去除率为74%.耗氧速率试验表明,强化启动后,流化床中生物膜的异养菌活性大幅度降低,氨氧化细菌活性明显提高,硝化细菌活性变化不大.对反应系统微生物醌进行的跟踪分析表明,强化启动后,生物膜中的硝化细菌数量明显增加,微生物种群的分布均匀性变化较小,以革兰氏阴性菌为主.扫描电镜观察显示,低N/C启动条件下,生物膜厚且致密,异养菌所占比例高;高N/C启动条件有利于硝化细菌的生长,生物膜相对稀薄.  相似文献   

4.
弹性填料净化受污染入湖河流的现场试验研究   总被引:4,自引:0,他引:4  
田伟君  郝芳华  翟金波 《环境科学》2008,29(5):1308-1312
利用新型弹性填料作为生物膜载体,将其直接布置在林庄港河道中,研究在不影响河流生态系统结构和使用功能的前提下,弹性填料对河流微污染水体的强化净化效果.现场试验在挂膜成功后共运行了半年.结果表明,弹性填料对氨氮的去除效果最好.它在整个运行期间对高锰酸钾指数的平均净去除率为5.4%,其中最高为9.9%;氨氮净去除率在5.35%~39.91%,总磷的净去除率最高也达到了28.6%.同时细菌学检验结果表明,高锰酸钾指数的去除率与附着在填料丝上的异养菌的数量存在正比关系;而亚硝酸菌和硝酸菌的数量也与氨氮的去除率变化相匹配.  相似文献   

5.
采用长纤维过滤器处理净水厂沉淀出水,详细检测了过滤液的主要水质参数。检测结果表明,长纤维过滤器对净水浊度、水中氨氮及亚硝酸盐氮、细菌及大肠菌群均有较优的去除效果,对CODMn的去除率达到40%以上。研究表明长纤维过滤器在深度处理净水中优势显著。  相似文献   

6.
用生物膜缺氧修复受污染的城市河道水   总被引:2,自引:0,他引:2  
张永明  胡一珍  严荣  刘芳 《环境科学》2009,30(7):1920-1924
采用一种类似氧化沟的反应器,其中利用蜂窝陶瓷为载体形成生物膜替代活性污泥,对城市受污染的河道水体进行缺氧生物修复.修复过程中控制溶解氧含量在0.5 mg/L以下,使生物反应在缺氧状态下运行.在此过程中,水中的氨氮去除率为40%~60%,总氮的去除率达到40%~45%,即氨氮和总氮得到同步去除,且没有亚硝酸盐积累.提取生物膜置于摇瓶内进行厌氧培养发现,氨氮和亚硝酸盐氮也得到同步去除,这表明在低碳氮比的微污染地表水的生物修复过程中同时有硝化-反硝化和厌氧氨氧化现象.通过分子生物学分析,证实在生物膜群落里存在具有厌氧氨氧化能力的微生物.这一结果有可能为富营养化水体的修复提供一种经济、实用的技术途径.  相似文献   

7.
移动床生物膜反应器对垃圾渗滤液短程硝化研究   总被引:2,自引:0,他引:2  
杜月  陈胜  孙德智 《环境科学》2007,28(5):1039-1043
采用好氧移动床生物膜反应器(MBBR)对经过厌氧脱碳处理的垃圾渗滤液进行了深度短程硝化研究,考察了在中温(25℃)条件下DO浓度、pH值、C/N等因素对氨氮去除效果和短程硝化效果的影响.结果表明,在进水氨氮浓度为400 mg·L-1,HRT为24 h情况下,当控制DO为2 mg·L-1、pH值在8左右和C/N小于3时,氨氮去除率能达到70%以上,亚硝酸盐氮的积累率高达90%.间歇试验证明了该生物膜反应器中亚硝化菌的数量和活性要远高于硝化菌.该移动床生物膜工艺可以选择性固定和积累氨氧化细菌,从而实现较高的氨氮去除率和稳定的亚硝酸盐氮积累率.  相似文献   

8.
硝化菌群强化修复氨氮污染河流水体研究   总被引:2,自引:0,他引:2  
利用已筛选的硝化菌群分别以游离菌和生物膜两种方式对成都市南干堰氨氮污染水体进行生物强化修复初步研究.结果表明,当进水氨氮浓度为23.91~24.27mg·L-1,在25℃、150r·min-1条件下,投加游离菌群36h后,氨氮去除率达95%,而在不添加游离菌的对照中,氨氮浓度没有下降.采用生物膜法,室温条件下,当进水氨氮浓度为8.00~18.38mg·L-1,水力停留时间(HRT)2~4h时,出水氨氮浓度为0~1.11mg·L-1,氨氧化负荷最高可达0.139kg·m-3·d-1(以N计,下同),氨氮去除率达90%以上;;当进水氨氮浓度为7.84~14.62mg·L-1,HRT为0·5~1.0h时,修复后出水氨氮浓度为1.90~7.47mg·L-1,氨氧化负荷最高可达0.261kg·m-3·d-1;;当进水氨氮浓度稀释到3mg·L-1左右,氨氮可完全被去除,修复后水体几乎没有亚硝酸盐残留.采用PCR-DGGE分析生物膜上的微生物菌群,发现生物膜中不仅有硝化菌群生长,还包括其它与氮转化相关微生物菌群.该实验结果表明,运用硝化菌群进行氨氮污染水体强化修复具有显著的效果,实际应用中可根据污染水体氨氮浓度以及氨氧化负...  相似文献   

9.
改良SBR工艺实现生活污水除磷与半亚硝化   总被引:3,自引:0,他引:3  
常温条件下(20~25℃),采用序批式反应器(SBR),应用改进后的运行策略:进水、厌氧搅拌、曝气搅拌、静置沉淀、排水、选择性排泥、污泥床缺氧搅拌,控制污泥龄为20d,溶解氧为0.2~0.5mg/L,实现单污泥系统同步除磷亚硝化的稳定运行.结果表明:总磷去除率为95.9%~97.1%,出水总磷浓度为0.1~0.4mg/L,好氧阶段氨氮去除容积负荷为0.242kg N/(m3·d),出水氨氮和亚硝酸盐氮的比值约为1:1,可以为后续的厌氧氨氧化提供合适的进水.  相似文献   

10.
模拟配水管网中悬浮颗粒物对生物膜形成的影响   总被引:1,自引:1,他引:0  
郑丹  刘文君  徐洪福 《环境科学》2007,28(6):1236-1240
分别采用2 μm、8 μm醋酸纤维滤膜过滤活性炭柱出水,滤出水分别通入BAR反应器,以活性炭出水做对照试验通入BAR反应器,加氯(次氯酸钠)量均为0.5 mg·L-1(总氯),对比3种水质情况下生物膜的形成过程,采用颗粒计数仪测定BAR进水的颗粒物分布.结果表明,悬浮颗粒物能携带大量细菌避开消毒剂的作用,且对生物膜上的细菌量有直接影响.生物膜上的细菌量为:活性炭出水>8 μm滤出水>2 μm滤出水.颗粒物的存在使生物膜结构不稳定,推迟了达到最大生物量的时间,且颗粒物数量越多,粒径越大,生物膜稳定性越差,达最大生物量的时间越长,试验中2号BAR生物膜达最大生物量的时间比1号BAR中生物膜迟4 d,3号BAR生物膜达最大生物量的时间比2号BAR生物膜迟8 d;进水颗粒物数量对出水的细菌量影响很大,颗粒物数量越多,出水细菌量越多.  相似文献   

11.
碳氮比对聚氨酯生物膜反应器短程硝化反硝化的影响   总被引:4,自引:3,他引:1  
谭冲  刘颖杰  王薇  邱珊  马放 《环境科学》2014,35(10):3807-3813
研究了聚氨酯生物膜反应器在短程硝化反硝化工艺中的应用,考察碳氮比(15∶1、10∶1、5∶1和1.8∶1)对聚氨酯脱氮系统脱氮性能和微生物群落结构的影响,以及微生物群落结构与其处理效果的对应关系.结果表明,经过100 d的运行,当进水碳氮比从15依次下降到10、5和1.8,亚硝酸氮累积率由56.1%逐次上升到62.3%、72.3%和83.2%.在进水碳氮比为10时,系统取得最佳处理效果,氨氮和总氮去除率分别为99.1%和91.0%.进水碳氮比在15、10、5和1.8时,硝化反应和反硝化反应均同时发生在聚氨酯生物膜系统内,随着进水碳氮比的降低,同时硝化反硝化效率逐渐降低.生物膜的功能微生物分析表明,在碳氮比15时,生物膜的微生物多样性要显著高于其他工况.生物膜上的优势亚硝酸菌和硝酸菌分别以亚硝化单胞菌(Nitrosospira sp.)和硝化螺旋菌(Nitrospira sp.)为主,而反硝化细菌则以假单胞菌(Pseudomonas sp.)占据优势.  相似文献   

12.
Anammox transited from denitrification in upflow biofilm reactor   总被引:5,自引:2,他引:5  
Anammox was successfully transited from heterotrophic denitrification and autotrophic denitrification in two upflow biofilm reactors, respectively. The results showed that the volumetric loading rate and nitrogen removal efficiency in the reactor transited from heterotrophic denitrification were higher than that in its counterpart. When the hydraulic retention time was 12 h or so, the total nitrogen loading rate was about 0.609 kg N/(m^3 .d), and the effluent ammonia and nitrite concentrations were less than 8.5 mg/L and 2.5 mg/L,respectively. The upflow anammox biofilm reactor was capable of keeping and accumulating the slow-growing bacteria efficiently. During operation of the reactor, the biomass color was gradually turned from brownish to red, and the ratio of ammonia consumption, nitrite consumption and nitrate production approached the theoretical one. These changes could be used as an indicator for working state of the reactor.  相似文献   

13.
Nitrogen removal via nitrite (the nitrite pathway) is more suitable for carbon-limited industrial wastewater. Partial nitrification to nitrite is the primary step to achieve nitrogen removal via nitrite. The effect of alkalinity on nitrite accumulation in a continuous process was investigated by progressively increasing the alkalinity dosage ratio (amount of alkalinity to ammonia ratio, mol/mol). There is a close relationship among alkalinity, pH and the state of matter present in aqueous solution. When alkalinity was insufficient (compared to the theoretical alkalinity amount), ammonia removal efficiency increased first and then decreased at each alkalinity dosage ratio, with an abrupt removal efficiency peak. Generally, ammonia removal efficiency rose with increasing alkalinity dosage ratio. Ammonia removal efficiency reached to 88% from 23% when alkalinity addition was sufficient. Nitrite accumulation could be achieved by inhibiting nitrite oxidizing bacteria (NOB) by free ammonia (FA) in the early period and free nitrous acid in the later period of nitrification when alkalinity was not adequate. Only FA worked to inhibit the activity of NOB when alkalinity addition was sufficient.  相似文献   

14.
生活污水常温处理系统中AOB与NOB竞争优势的调控   总被引:10,自引:4,他引:6  
曾薇  张悦  李磊  彭永臻 《环境科学》2009,30(5):1430-1436
常温(19℃±1℃)条件下,采用SBR工艺处理低碳氮比(C/N)实际生活污水,研究氨氧化菌(AOB)与亚硝酸盐氧化菌(NOB)竞争优势的调控,在接种全程硝化污泥的系统中使AOB成为优势菌群,启动并维持常温短程硝化.通过控制曝气量为40 L/h使系统溶解氧处于较低水平(DOaverage<1.0 mg/L),同时结合好氧硝化时间的优化控制,即在pH值“氨谷"点前及时停止曝气的短周期定时控制,强化AOB的竞争优势.待AOB的竞争优势初步形成后(亚硝酸盐积累率NO-2-N/NO-x-N达到50%),每周期曝气时间随着NO-2-N/NO-x-N的提高由3 h逐步延长至4 h、 5 h,从而提高NH+4-N去除率,进一步增强AOB在系统中的竞争优势,短程硝化成功启动,NO-2-N/NO-x-N稳定在95%以上.FISH检测结果表明AOB大约占总菌群的9.97%.在线控制好氧硝化时间可以很好地维持短程硝化效果,NH+4-N去除率达到97%以上.研究还表明,对于全程硝化污泥常温下如果不限制溶解氧,单纯依靠短周期定时控制无法使AOB成为优势硝化菌群.  相似文献   

15.
水源水生物处理工艺中亚硝酸盐氮的去除   总被引:6,自引:1,他引:6  
通过中试规模试验系统 ,分析了不同运行条件下微污染水源水生物接触氧化处理工艺中亚硝酸盐氮的去除状况 ,探讨了亚硝酸盐氮积累量与氨氮去除率之间的关系。指出处理系统中硝酸盐细菌对亚硝酸盐细菌生化过程的依赖作用是亚硝酸盐氮积累的内因 ,而工艺参数等运行条件的变化是亚硝酸盐氮积累的外因 ,提高氨氮去除率是去除亚硝酸盐氮的关键。  相似文献   

16.
硝化细菌在不同温度下对氮素的去除效能研究   总被引:4,自引:0,他引:4  
在15℃进行硝化细菌的富集,菌种的分离纯化,初筛,硝化效果的测定。对其中4株硝化效果较好的亚硝酸菌BY5、SY6和硝酸菌BX4、SX5进行生理生化指标鉴定,将其鉴定到属:前两者属于亚硝酸单胞菌属,后两者属于硝酸杆菌属。研究了不同温度对这4株菌株硝化效果的影响。结果表明,4株菌的最适合温度为25℃-30℃,亚硝酸菌的氨氮去除率可以达到74%,硝酸菌的亚硝酸盐去除率可以达到70%,在15℃时,亚硝酸菌和硝酸菌的氨氮去除率争亚脯酸盐去除率均可达到60%以上。  相似文献   

17.
对典型有机防晒剂二苯甲酮-9(BP9)在氯消毒过程中的氧化反应进行研究,考察BP9初始浓度、余氯初始浓度、溶液pH值和氨氮浓度对反应的影响,探究BP9氯氧化降解机理,评估其生态风险.结果表明,在BP9初始浓度5mg/L、余氯初始浓度5mg/L的条件下,90s内BP9去除率达到91.3%,符合准一级反应动力学.降解速率常数随着BP9初始浓度及氨氮浓度增加而减小,随余氯初始浓度增大而增大,中性条件下有利于BP9氯氧化反应.基于HPLC-MS/MS和GC-MS解析出7种中间产物,提出可能降解路径.发光细菌毒性分析和ECOSAR预测均表明,BP9氯氧化反应生成了比母物质毒性更高的中间产物,对饮用水水质安全造成潜在风险.  相似文献   

18.
基于EPANET-MSX的多组分给水管网水质模型的开发与应用   总被引:2,自引:0,他引:2  
孙傅  陈吉宁  曾思育 《环境科学》2008,29(12):3360-3367
基于EPANET-MSX工具包开发了机制性的多组分给水管网水质模型,模型将管段概化为管壁、生物膜、液膜和液相4个组成部分.模拟过程包括基质利用和微生物生长、微生物衰减和死亡、溶解性物质的液膜传质、不溶性物质的吸附和脱落、余氯与有机物的氧化和卤代反应以及管壁腐蚀消耗余氯等.模拟变量共15个,包括生物膜和液相中各7个变量,即溶解性有机物、不溶性有机物、氨氮、余氯、异养菌、自养菌和惰性颗粒,以及管壁生物膜厚度.利用管段模拟实验数据进行模型验证,模型对余氯和浊度的模拟精度分别为0.1 mg/L和0.3 NTU.案例研究的模拟结果合理地反映了给水管网中余氯和浊度的动态变化特征,而同时考虑水厂出水水质可变性和参数不确定性的Monte Carlo模拟则可用于评价案例给水管网的水质超标风险.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号