首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 218 毫秒
1.
采用厌氧-好氧-混凝工艺,对垃圾焚烧厂高DOM渗滤液进行处理,当进水ρ(CODCr)平均值为10 800 mg/L时,出水ρ(CODCr)平均值可达208 mg/L;同时,着重针对各工艺单元出水DOM不同分子质量分布区间的ρ(CODCr)以及DOM组成成分的变化进行了研究.结果表明:该处理工艺对DOM分子质量<50 ku的有机物去除率均可达到94.7%以上,而对分子质量<2 ku的有机物的去除率可达99.0%;对渗滤液DOM组成成分〔腐殖酸(HA)、富里酸(FA)和亲水性有机质(HyI)〕的去除率均达到90.0%以上,表明该组合工艺用于处理垃圾焚烧厂渗滤液是可行的.   相似文献   

2.
通过混凝-异相Fenton组合工艺对高有机物含量的垃圾渗沥液纳滤浓缩液进行试验研究.考察不同处理工况对纳滤浓缩液有机物去除效果的影响.并通过正交试验得出组合工艺的最优工况,分析最优工况下出水达标的可行性.对组合工艺在反应过程中溶解性有机质及氮污染物含量的变化情况进行探讨.并分析了组合工艺的药剂投加成本.结果表明:组合工艺对COD去除的最优处理工况为:PFS投加量为6g/L,混凝初始pH值为7,PAM投加量为25mg/L、H2O2与COD质量比为10,Fenton反应初始pH值为4,催化剂与COD质量比为16.在最优工况下COD去除率为98.62%.经组合工艺处理后出水水质可实现达标排放.在反应过程中,混凝单元能够降低异相Fenton单元的处理负荷并保证了组合工艺出水中TN和NH4+-N的达标排放,组合工艺对浓缩液中HA、FA与TON的去除率分别为93.54%、86.80%与83.98%.异相Fenton单元对混凝过程中去除效果稍差的HyI进一步氧化分解而实现COD出水达标,其去除率为86.02%.在...  相似文献   

3.
渗滤液场内处理的有机物去除特征和植物毒性评价   总被引:5,自引:1,他引:4  
摘要:以3种不同处理水平的渗滤液为研究对象,从有机物去除特征和植物毒性角度研究通过渗滤液循环回灌和终场覆盖层灌溉2个单元处理生活垃圾填埋场渗滤液的可行性.结果表明,循环回灌对老港渗滤液中的小分子量亲水性物质类(HyI)有机物去除效果较好,去除率为91.2%;终场覆盖层灌溉对循环回灌出水中的高分子量腐殖质类(HS)有机物去除效果较佳,去除率为85.7%;两者串联组合的场内循环处理工艺对老港渗滤液中的溶解性有机物(DOM)去除 率高达96.9%,且对HS和HyI均具较高的去除效果,去除率分别为96.6%和97.0%;循环回灌和覆盖层灌溉这2个处理单元还具有梯级降低渗滤液植物毒性的作用.  相似文献   

4.
采用2个模拟填埋生物反应器,1号柱渗滤液简单回灌,2号柱为渗滤液回灌准好氧联合运行方式,研究了渗滤液回灌准好氧生物反应器填埋场的脱氮特性及加速垃圾稳定化特性。研究结果表明:渗滤液回灌准好氧填埋场具有很强的脱氮能力,2号柱由厌氧运行方式改为准好氧条件下,渗滤液中的氨氮和凯式氮浓度分别由最大值的3198mg/L和3345mg/L降低到第160d的73mg/L和81mg/L,去除率分别为97.7%和97.6%,pH快速升高到8.0左右,COD浓度快速降低。渗滤液中溶解性有机物(DOM)分级结果表明,2号柱HA和FA含量的增加明显快于1号柱。2号柱DOM的三维荧光光谱特性发生了较大变化,荧光基团从60d结构简单的类蛋白物质转变为95d结构复杂的类胡敏酸和富里酸物质,而1号柱渗滤液DOM荧光基团一直是结构简单的类蛋白物质。结果表明回灌准好氧生物反应器填埋场的稳定化速度远快于简单回灌的生物反应器填埋场。  相似文献   

5.
纳米Fe_3O_4强化混凝-Fenton氧化预处理垃圾渗滤液   总被引:1,自引:1,他引:0       下载免费PDF全文
采用纳米Fe_3O_4与Fe Cl3制备复合混凝剂,利用混凝沉淀-Fenton氧化工艺预处理垃圾渗滤液原水,研究其处理效果。结果表明:在纳米Fe_3O_4投加量为2 g/L,Fe Cl3投加量为1.4 g/L时制备的复合混凝剂,在p H值为6.5,转速为300 r/min下快速搅拌1 min,转速为100 r/min下慢速搅拌30 min,沉淀时间为30 min的条件下,COD去除率为56.8%,ρ(COD)可由5 240 mg/L降低到2 264 mg/L;利用Fenton氧化处理混凝处理出水,在H_2O_2的投加量为5.5 g/L,n(H_2O_2)∶n(Fe2+)=4,p H值为6,反应时间为80 min,反应温度为25℃的最佳条件下,COD和氨氮的去除率分别为55.7%和40.1%,最终出水ρ(COD)和ρ(氨氮)分别为1 003 mg/L和670 mg/L;该组合工艺对垃圾渗滤液有较好的处理效果,COD、色度和氨氮的去除率分别为80.8%、59.5%和76.2%。  相似文献   

6.
本文根据晚期垃圾渗滤液的水质特征,通过查阅文献,采用SH-A+物化新技术对其进行处理。实验研究结果表明,物化+SH-A新技术可以有效处理晚期垃圾渗滤液,氨氮去除率达到99%以上,氨氮出水浓度小于25mg/L;COD去除率85%以上,COD出水浓度小于300mg/L。  相似文献   

7.
催化湿式过氧化氢氧化处理垃圾渗滤液及其DOM光谱分析   总被引:1,自引:0,他引:1  
采用催化湿式过氧化氢氧化法对转运站垃圾渗滤液进行了处理,研究了影响催化湿式过氧化氢氧化效果的多个因素,并采用三维荧光和紫外-可见光谱对催化湿式过氧化氢氧化处理后水样中的溶解性有机物(DOM)成分变化进行了表征分析.结果显示,在最优实验条件下,COD去除率可达90%以上.光谱分析结果表明,渗滤液中的DOM组分降解效果明显,含有芳香环、双键和羰基共轭体系的有机物的去除效果也比较显著.  相似文献   

8.
对再生水包气带渗滤过程进行模拟实验,分析此过程中总溶解性有机物(DOM)含量和结构组成的变化规律,并采用IHSS推荐方法提取主要有机物组成进行分析表征。结果表明:经回灌处理后,再生水ρ(COD)由57.90 mg/L(0 h)降低至21.50 mg/L(159 h),去除率达到63%;ρ(DOC)相应由12.40 mg/L降低至7.16 mg/L,去除率达到42%。荧光区域积分计算结果表明,再生水中DOM主要由芳香蛋白类物质和溶解性微生物代谢产物组成,包气带土壤介质中的DOM则主要由腐植酸类物质组成;受土壤DOM淋溶释放影响,实验过程中淋滤出水DOM组成主要以腐植酸类物质为主(占比>0.6)。SEM及EDS分析结果表明,腐植酸表面呈海绵状,主要由C(64.40%)、O(34.25%)元素组成,FTIR分析得出其中含有羟基和羧基等活性官能团,紫外可见光谱呈现单调而无特征性的现象,特征峰值计算显示所提取腐植酸属于大分子范畴。  相似文献   

9.
三峡库区填埋场和焚烧厂渗滤液水质季节性差异   总被引:5,自引:3,他引:2  
分析了重庆长生桥垃圾填埋场和同兴焚烧厂渗滤液在常规水质和溶解性有机质组成结构方面的季节性差异. 结果表明,填埋场渗滤液在夏季的ρ(CODCr), ρ(TOC), ρ(BOD5),ρ(BOD5)/ρ(CODCr)和ρ(VFA)均高于其他季节,相应指标在冬季最低,但ρ(NH3-N)和 pH的季节性差异不明显. 填埋场渗滤液中DOM组成结构的季节性差异较大,表现在冬季渗滤液中HA所占比例最高,为16.1%,而春、夏季分别为6.6%和8.1%;冬季渗滤液中HyI所占比例最低,为32.7%,其他季节为41.9%~43.5%;ρ(FA)的季节性差异相对较小. 填埋场中ρ(FA)/ρ(HA)的季节性差异较大,夏季较高,冬季较小. 焚烧厂渗滤液的常规水质,DOM的构成及ρ(FA)/ρ(HA)的季节性差异均很小.   相似文献   

10.
将A3O3工艺用于徐州某垃圾焚烧发电厂渗滤液好氧段处理工程,讨论了工艺流程、构筑物设计参数和运行状况。结果表明,在A3O3反应池有机负荷OLR为0.6 kg(COD)/(m~3·d)、进水COD为1 900~3 000 mg/L、氨氮为1 000 1 650 mg/L的情况下,出水COD800 mg/L和氨氮5 mg/L时,A3O3反应池对COD和氨氮的去除率分别在60%和98%以上。同时分析了pH、DO和温度对氨氮去除率的影响。  相似文献   

11.
A laboratory scale test was conducted in a combined membrane process (CMP) with a capacity of 2.91 m3/d for 240 d to treat the mixed wastewater of humidity condensate, hygiene wastewater and urine in submarine cabin during prolonged voyage. Removal performance of chemical oxygen demand (COD), ammonia nitrogen (NH4 +-N), turbidity and anionic surfactants (LAS) was investigated under di erent conditions. It was observed that the e uent COD, NH4 +-N, turbidity and LAS flocculated in ranges of 0.19–0.85 mg/L, 0.03–0.18 mg/L, 0.0–0.15 NTU and 0.0–0.05 mg/L, respectively in spite of considerable fluctuation in corresponding influent of 2120–5350 mg/L, 79.5–129.3 mg/L, 110–181.1NTU and 4.9–5.4 mg/L. The e uent quality of the CMP could meet the requirements of mechanical water and hygiene water according to the class I water quality standards in China (GB3838-2002). The removal rates of COD, NH4 +-N, turbidity and LAS removed in the MBR were more than 90%, which indicated that biodegradation is indispensable and plays a major role in the wastewater treatment and reuse. A model, built on the back propagation neural network (BPNN) theory, was developed for the simulation of CMP and produced high reliability. The average error of COD and NH4 +-N was 5.14% and 6.20%, respectively, and the root mean squared error of turbidity and LAS was 2.76% and 1.41%, respectively. The results indicated that the model well fitted the laboratory data, and was able to simulate the removal of COD, NH4 +-N, turbidity and LAS. It also suggested that the model proposed could reflect and manage the operation of CMP for the treatment of the mixed wastewaters in submarine.  相似文献   

12.
中试采用生物膜与活性污泥复合工艺对中国北方某城镇污水处理厂的污水进行处理,考察其在低温条件下对污水中的有机物及含氮污染物的去除能力.结果表明,当进水COD和NH+4-N浓度分别为53~140 mg/L和21~78 mg/L时,生物膜与活性污泥复合工艺出水COD和NH+4-N浓度分别在24~48 mg/L和0.5~3 mg/L范围内,满足《城镇污水处理厂污染物排放标准》一级A标准(冬季COD<50 mg/L,NH+4-N<8 mg/L),而该污水处理厂原有工艺出水COD和NH+4-N浓度分别在20~73 mg/L和9~20 mg/L之间.因此,在低温条件下,生物膜与活性污泥复合工艺能够提高对污染物的去除能力.  相似文献   

13.
改良UCT分段进水工艺处理生活污水性能优化研究   总被引:1,自引:1,他引:0  
在某大型污水处理厂采用中试规模的改良UCT分段进水脱氮除磷工艺处理低COD/N生活污水,重点研究了流量分配比和原水营养元素比(COD/N、COD/P和TN/P)对工艺脱氮除磷性能的影响,目的是分析探索工艺对有机物和氮磷去除机制和污泥特性.连续运行试验表明,该工艺取得稳定高效的去除性能.在进水COD负荷为0.79~0.9...  相似文献   

14.
生物滤池A/O工艺处理焦化废水研究   总被引:4,自引:1,他引:3  
赖鹏  赵华章  叶正芳  倪晋仁  曾明 《环境科学》2007,28(12):2727-2733
采用具有特定载体的生物滤池A/O工艺处理焦化废水.废水含有高浓度酚类化合物,COD和NH+4-N分别约2?000 mg/L和260 mg/L.在HRT为60 h时,COD和NH+4-N平均去除率分别达到了87.0%和91.6%,最佳条件下出水NH+4-N浓度达到了国家一级排放标准.生物滤池A/O工艺高效去除了原水中小分子质量的酚类化合物,出水中有机物主要分布于10?000~30?000相对分子质量范围,且含有—OH、CO、C—O等官能团和苯环结构.由于载体的支持和保护作用,大量微生物固定于载体的表面和内部,实现了COD、NH+4-N和TN的同时去除.生物滤池A/O系统具有运行稳定、抗冲击等优点.  相似文献   

15.
李纪华  王正芳  郑正 《环境工程》2012,(Z2):41-43,129
曝气生物滤池(BAF)是在普通生物滤池的基础上,借鉴给水滤池工艺开发的污水处理新工艺。以炉渣为填料采用前置反硝化曝气生物滤池处理模拟生活污水,研究了前置反硝化曝气生物滤池处理生活污水的启动状况,考察了启动过程中COD、NH4+-N等主要污染物的去除情况。试验结果表明,在水力负荷为1.74m/h、回流比150%、气水比为3∶1的条件下,COD和NH4+-N分别在35d和45d内得到了有效地去除。其中,COD出水浓度降到30mg/L以下,去除率稳定在85%以上;NH4+-N出水浓度降到10mg/L以下,去除率稳定在65%以上。研究结果表明选用炉渣作填料的前置反硝化曝气生物滤池在相对较短的时间内启动效果良好。  相似文献   

16.
针对某一城市污水处理厂"混合型城市污水"的特征,以厂区曝气沉砂池出水作为处理对象,设计一套A2/O工艺强化脱氮除磷中试装置。当进水COD、NH3-N、TN、TP的平均质量浓度分别为594,25.0,37.6,7.66 mg/L时,经A2/O工艺强化处理后,出水COD、NH3-N、TN、TP的平均质量浓度分别为46.7,5.5,12.73,0.7 mg/L,对COD、NH3-N、TN、TP的平均去除率分别达91.51%、79.73%、65.78%和88.65%,出水水质达GB 18918—2002《城镇污水处理厂污染物排放标准》一级标准,取得了良好的污染物去除和脱氮除磷效果,且当系统稳定运行时总体出水水质相对稳定。  相似文献   

17.
针对现有制革废水处理工艺难以使氨氮达标排放的问题,引入多段A/O工艺(MAOP)作为制革废水二级生物处理单元,探讨分段进水、水力停留时间(HRT)以及污泥回流比(R)对其COD和氨氮同步去除的影响.结果证明,无论是否分段进水,四段MAOP对制革废水一级生化出水均有良好的COD去除效果,当污泥停留时间(SRT)为18d、HRT不小于24h时,其出水浓度都可保持在300mg/L以下,满足GB8978-1996二级排放标准.在各段进水比为4:3:2:1、R 100%、HRT 48h、SRT 18d条件下,MAOP对制革废水一级生化出水的氨氮去除率高达97.7%,出水浓度3.6mg/L左右,达到GB8978-1996一级排放标准.MAOP同时具备反硝化、短程硝化反硝化、同步硝化反硝化等多种脱氮机制,是一种颇具前景的制革废水生物脱氮技术.  相似文献   

18.
针对现有制革废水处理工艺难以使氨氮达标排放的问题,引入多段A/O工艺(MAOP)作为制革废水二级生物处理单元,探讨分段进水、水力停留时间(HRT)以及污泥回流比(R)对其COD和氨氮同步去除的影响.结果证明,无论是否分段进水,四段MAOP对制革废水一级生化出水均有良好的COD去除效果,当污泥停留时间(SRT)为18d、HRT不小于24h时,其出水浓度都可保持在300mg/L以下,满足GB8978-1996二级排放标准.在各段进水比为4:3:2:1、R 100%、HRT 48h、SRT 18d条件下,MAOP对制革废水一级生化出水的氨氮去除率高达97.7%,出水浓度3.6mg/L左右,达到GB8978-1996一级排放标准.MAOP同时具备反硝化、短程硝化反硝化、同步硝化反硝化等多种脱氮机制,是一种颇具前景的制革废水生物脱氮技术.  相似文献   

19.
研究混凝-MBR组合技术净化洗车废水,首先对该技术净化CODcr、UV254、NH3 -N和浊度的效果进行了考察,实验结果表明,当废水温度大于22℃时、溶解氧浓度大于4.8 mg/L时、pH值在6到8之间的条件下,该组合技术对CODcr、NH3 -N和浊度的净化效果较好,平均净化率分别达到90.2%、96.4%和98%以上,高于传统MBR技术和常规技术,出水CODcr约为20 mg/L,NH3 -N基本在0.7 mg/L以下,浊度也小于0.5NTU,水质优于中国建设部生活杂用水水质标准( CJ25.1-89).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号