首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   11篇
  免费   0篇
污染及防治   10篇
评价与监测   1篇
  2020年   1篇
  2013年   6篇
  2007年   3篇
  2006年   1篇
排序方式: 共有11条查询结果,搜索用时 15 毫秒
1.
A molecularly imprinted polymer (MIP) for atrazine was synthesized by non-covalent method. The binding capacity of MIP was 1.00 mg g? 1 polymer. The selectivity and recovery were investigated with various pesticides which are mostly, found in the environment, for both similar and different chemical structure of atrazine. The competitive recognition between atrazine and structurally similar compounds was evaluated and it was found that the system provided highest recovery and selectivity for atrazine while low recovery and selectivity were obtained for the other compounds. The highest recovery was obtained from MIP compared with non-imprinted polymer (NIP), a commercial C18 and a granular activated carbon (GAC) sorbent. The method provided high recoveries ranged from 94 to 99% at two spiked levels with relative standard deviations less than 2%. The lower detection limit of the method was 80 ng L? 1. This method was successfully applied for analysis of environmental water samples.  相似文献   
2.
A simple sample preparation technique was developed for rapid analysis of acetaldehyde residue in Polyethylene Terephthalate (PET) bottles. A laboratory-built heating system was used and coupled with gas chromatography-flame ionization detector (GC-FID) at optimized conditions. The results were a tremendous reduction of the sample preparation time from 24 hours, for the conventional method, to only one hour. The analysis took only 1.5 min with other good analytical performances i.e. a low detection limit, 0.3 ng mL? 1 and a wide linear dynamic range, 0.3 ng mL? 1 to 6.6 μ g mL? 1 with R2 > 0.99.Acetaldehyde residue in freshly blown bottles were analyzed and found in the range of 0.4 to 1.1 ng mL? 1. The results were good agreement with the conventional 24-hour airspace method (P < 0.01). The PET-bottle sampling technique was also developed to minimize the complication of sample transportation and pre-concentration. A purge and trap technique was found to be the most suitable. Then, it was implemented and compared, the results showed no significant difference (P < 0.01) with and without purge and trap.  相似文献   
3.
An in-line system for trace persistent organic pollutants (POPs) in water was developed by using a laboratory-made hollow fiber membrane (HFM) unit connected with a high-resolution gas chromatograph-mass spectrometer (HRGC-MS). The semivolatile organic compound, 4,4'-Dichlorodiphenyl trichloroethane (4,4'-DDT), was chosen as a representative of a persistent organic compound. The synthetic water contaminated with 4,4'-DDT was passed through the HFM unit, the extraction occurred by the analyte pervaporated and permeated, then stripped into HRGC-MS. Several factors were investigated for the high extraction efficiency. The best performance was obtained at sample and stripping gas flow rates of 6 and 9 mLmin-1, respectively, and desorption temperature of 60 degrees C. At this temperature, the diffusion rate was enhanced by 15 times over 25 degrees C. A wide linear dynamic range was obtained, i.e., 0.10-1.0 mgL-1, with a limit of detection (LOD) of 90 microgL-1. The extraction efficiency of 4,4'-DDT in real water samples was in the range of 83-94%. Real water samples were analyzed and 0.6 microgL-1 of 4,4'-DDT was found in unregistered bottled water and 7.0 microgL-1 in tap water.  相似文献   
4.
Abstract

This work reports the development of a very-simple-to-construct stir-bar extraction device so called “a dumbbell-shaped stainless steel stir-bar.” The extraction device was assembled from a rolled up stainless steel net filled with an XAD-2 sorbent and a metal rod to allow the use of a magnetic stirrer during extraction. The dumbbell-shaped stainless steel stir-bar was used to extract diethyl phthalate (DEP), dibutyl phthalate (DBP), and di(2-ethylhexyl) phthalate (DEHP) before analysis by a gas chromatograph equipped with an electron capture detector (GD-ECD). Under the optimal conditions, the developed method provided a good linearity from 10.0 to 1,000.0?ng mL?1 for all three compounds. Limits of detection and limits of quantification were 9.37?±?0.29?ng mL?1 and 31.22?±?0.95?ng mL?1 for DEP, 5.73?±?0.31?ng mL?1 and 19.1?±?1.0?ng mL?1 for DBP and 3.30?±?0.06?ng mL?1 and 11.0?±?0.19?ng mL?1 for DEHP, respectively. Good recoveries in the range of 81.89?±?0.17 to 109.5?±?2.0% were achieved when the method was used to extract phthalate esters in five instant noodle and two rice soup samples.  相似文献   
5.
A method for trace analysis of two plasticizers, di-2-ethylhexyl phthalate (DEHP) and di-2-ethylhexyl adipate (DEHA), contaminated in packaged curry paste were investigated by gas chromatography with flame ionization detector (GC-FID). Curry paste samples were extracted by ultrasonic and solid phase extraction using Florisil® cartridge. Analysis by the GC-FID system provided limits of detection for DEHA and DEHP at 12 and 25 μ g L? 1 and a linear dynamic range between 25 μ g L? 1 to 60 mg L? 1 with a coefficient of determination (R2) greater than 0.99. High recoveries were obtained, ranged from 91 to 99% and 88 to 98% for DEHP and DEHA with RSD lower than 7 and 10% respectively. The method detection limit and limits of quantitation were ranged from 27 to 30 and 90 to 100 μ g L? 1. The analysis of curry paste samples showed concentrations of DEHP and DEHA in the range of 4.0 ng g? 1 to 0.61 μg g? 1.  相似文献   
6.
A novel pipette-tip extractor of a graphene/poly (vinyl alcohol) cryogel (graphene/PVA) composite sorbent was prepared to preconcentrate carbamate pesticides in environmental water samples before analysis with a gas chromatograph-flame ionization detector (GC-FID). This novel pipette-tip extractor with the graphene/PVA sorbent exhibited a high porosity when observed through a scanning electron micrograph (SEM). Under optimal conditions, using only 1.0 mL of sample and 0.75 mL of eluting solvent, the developed method provided a wide linear range of 10–700 ng mL?1 and 10–500 ng mL?1 with limit of detection (LOD) of 6.40 ± 0.18 and 9.17 ± 0.34 ng mL?1 for carbofuran (2,3-dihydro-2,2-dimethylbenzofuran-7-yl methylcarbamate) and carbaryl (1-naphthyl methylcarbamate), respectively. The pipette-tip extractor provided high extraction efficiency with high accuracy indicated, by good recoveries in the range of 74.5 ± 4.8% to 119.7 ± 1.6% and 76 ± 15% to 114 ± 19% for carbofuran and carbaryl, respectively. In addition, the fabrication procedure showed a good pipette-tip extractor-to-pipette-tip extractor reproducibility with a relative standard deviation of 1.3–9.8% (n = 5). When the developed pipette-tip extractor was applied for the extraction of carbofuran and carbaryl in surface water samples near vegetable plantation areas, 25.9 ± 8.2 ng mL?1 of carbofuran was found, and carbaryl was also detected in concentrations that ranged from 45.0 ± 4.0 to 191 ± 13 ng mL?1.  相似文献   
7.
A simple and rapid online microchannel preconcentrator coupled with an amperometric detection for the analysis of carbofuran using polyethylene glycol coated onto magnetic particle (PEG-magnetic particles) sorbents was developed. This simple-to-prepare microchannel preconcentrator used an external magnet to retain the PEG-magnetic particle sorbents inside the microchannel. Under optimum conditions, the system provided two linear ranges, from 0.01 to 10.0 mg L?1 and from 10.0 to 130.0 mg L?1 with a limit of detection of 8.7 ± 0.1 μg L?1. The microchannel preconcentrator provided very good stability; it can be used for up to 326 consecutive injections of 5.0 mg L?1 carbofuran with a relative standard deviation of less than 3%. The developed system provided a good microchannel-to-microchannel and a good electrode-to-electrode reproducibility (n = 6, %RSD < 1). It also provided an excellent selectivity when it was tested with two other carbamate pesticides, carbaryl and methomyl, with a 43 and 256 times higher detection sensitivity for carbofuran, respectively. The developed system was successfully applied to detect carbofuran in surface water samples obtained near vegetable plantation areas. The concentrations of carbofuran in these samples were found to be in the range of non-detectable to 0.047 ± 0.001 mg L?1. The developed system is easy to operate and easy to couple with other analytical instruments and it could be easily adapted for the analysis of other polar organic contaminants.  相似文献   
8.
Capillary microextractor (CME) in combination with a gas chromatograph-mass spectrometer (GC-MS) was employed for the determination of trace priority hazardous substances in water. Three groups of semivolatile organic compounds (SVOCs), i.e., chlorinated hydrocarbons, pesticides and polycyclic aromatic hydrocarbons (PAHs), were simultaneously determined. SVOCs were extracted from 7 mL of water samples on a 100 cm commercial gas chromatographic column (0.32 mm id x film thickness 0.25 microm, HP-5 capillary column) and eluted with only 3 microL of acetonitrile. The extractant was analyzed by GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range 10 ng L(-1) to 3.0 mg L(-1) with correlation coefficients (r) greater than 0.99 and low limits of detection ranged from 10 ng L(-1) to 1.0 mg L(-1). High recovery (more than 80%) was obtained with relative standard deviation less than 10%. The method was successfully applied for trace level analyses of SVOCs in water samples.  相似文献   
9.
An innovative, cost-effective, simple, and environmental friendly tea bag filter paper protected micro-solid phase extraction (μ-SPE) technique was developed for the first time with the aim to miniaturize and minimize the use of organic solvents for the extraction and determination of butachlor in aqueous samples. The μ-SPE device was produced by packing 3.0 mg of an easily synthesized new sorbent, hydroxyl-functionalized polypyrrole (OH-PPY), inside a small tea bag filter paper sachet (1.0 cm × 0.5 cm) that served as a protective envelope. Both the extraction and desorption procedures were facilitated by sonication. Due to the high porosity and the fast water absorption of the tea bag filter paper, the analyte could easily diffuse through and enhance the interaction with the sorbent. Under the optimized conditions for the GC-ECD and the μ-SPE, the limit of detection (S/N ≥ 3) was 2.0 μg L?1 while the limit of quantitation (S/N ≥ 10) was 10.0 μg L?1. The recoveries of the butachlor spiked at 0.050, 0.10, and 0.50 μg mL?1 ranged from 77.9 ± 3.0 to 112.5 ± 2.9%. The proposed method was successfully applied for the determination of butachlor in water samples from paddy cultivation sites. The levels found were from non-detectable to 24.71 ± 0.37 μg L?1.  相似文献   
10.
A method for trace analysis of two plasticizers, di-2-ethylhexyl phthalate (DEHP) and di-2-ethylhexyl adipate (DEHA), contaminated in packaged curry paste were investigated by gas chromatography with flame ionization detector (GC-FID). Curry paste samples were extracted by ultrasonic and solid phase extraction using Florisil(R) cartridge. Analysis by the GC-FID system provided limits of detection for DEHA and DEHP at 12 and 25 microg L(- 1) and a linear dynamic range between 25 microg L(- 1) to 60 mg L(- 1) with a coefficient of determination (R(2)) greater than 0.99. High recoveries were obtained, ranged from 91 to 99% and 88 to 98% for DEHP and DEHA with RSD lower than 7 and 10% respectively. The method detection limit and limits of quantitation were ranged from 27 to 30 and 90 to 100 microg L(- 1). The analysis of curry paste samples showed concentrations of DEHP and DEHA in the range of 4.0 ng g(- 1) to 0.61 microg g(- 1).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号