1.
简捷硝化-反硝化过程处理焦化废水的研究   总被引:4,自引:0,他引:4  
简捷硝化-反硝化过程处理焦化废水具有去除负荷高、出水浓度低、可节省反硝化碳源等优点.试验表明,当系统进水COD、NH3-N和TN浓度分别为1204.8、274.3和443mg/L,系统总水力停留时间为26.2h时,系统出水COD、NH3-N、NO2--N、NO3--N和TN浓度分别为36.3、12.1、9.25、2.46和44.4mg/L.试验结果还证明本文所采用的系统确实处于简捷硝化-反硝化状态.  相似文献   

2.
土霉素结晶母液酸化水解过程的研究   总被引:8,自引:2,他引:6  
土霉素结晶母液是一类含高浓度有机物和氮的废水,反硝化电子供体相对不足,且含有多种生物抑制性物质.为了提高废水的可生化性、增加可利用反硝化电子供体的数量,利用厌氧污泥床对土霉素结晶母液进行了水解处理,并对反应的pH、COD、NH4+、和SO42--浓度等进行了考察.水解过程对COD的去除功能不强,在HRT1.5h~6.0h的条件下,COD去除率也仅从10%提高到16%.由于有机氮氨化和硫酸盐还原作用,酸化后废水的pH值增加.当HRT超过2h以后,SO42-基本上都被还原成S2-采用经过水解的废水进行批量实验,结果证明硝化速率和反硝化速率分别比未水解时提高90.9%和45.2%.  相似文献   

3.
添加原水改善SBR工艺处理猪场废水厌氧消化液性能   总被引:26,自引:7,他引:19  
采用序批式反应器(SBR)工艺直接处理猪场废水厌氧消化液,处理系统的效率较低,COD去除率仅有10%左右,NH4+-N去除率70%左右;处理出水水质较差,出水COD高于1 000mg/L,出水NH4+-N在200mg/L左右;处理系统的工作不稳定,效能逐渐恶化.在猪场废水厌氧消化液中添加部分未经厌氧消化的猪场废水(原水),处理系统的处理效率明显提高,COD去除率高于80%,出水COD降到250~350mg/L;NH4+-N去除率高于99%,出水NH4+-N小于10mg/L;处理系统的稳定性也得到增强.添加原水后,猪场废水厌氧消化液的BOD5/COD比值从0.19上升到0.54,BOD5/TN比值从0.28上升到2.04,增加了微生物生长和反硝化所需的碳源,强化了反硝化作用,不仅提高了总氮去除效率,而且通过回补碱度,维持了处理系统的pH值稳定.  相似文献   

4.
膜曝气生物膜反应器同步硝化反硝化研究   总被引:3,自引:0,他引:3  
炭膜作为膜曝气生物膜反应器膜组件处理人工合成废水,在单一反应器内实现了同时去碳脱氮.结果表明,当进水COD和NH4-N浓度分别为338 mg/L和75 mg/L,HRT为14 h,炭膜腔内压力为13.6 kPa时,COD、NH+4-N和TN的去除效率分别为82.5%、 95.1%和84.2%.但是在反应器运行的后期TN去除效率明显下降,主要是因为高有机负荷导致无纺布上的微生物过度繁殖,严重影响了硝化过程的进行.通过荧光原位杂交和扫描电镜技术观察生物膜微生物结构,得出厌氧或兼氧菌主要分布在生物膜外层的缺氧区,而氨氧化菌主要分布在生物膜内层的好氧区.硝化细菌和反硝化细菌在生物膜内的共存实现了炭膜曝气生物膜反应器的同步硝化反硝化.  相似文献   

5.
BACF处理高氨氮进水的硝化与反硝化作用   总被引:4,自引:1,他引:3  
采用生物活性炭滤池(BACF)深度处理高NH4+-N微污染水源水.结果表明,BACF对NH4+-N的去除率与进水NH4+-N浓度有关,当进水NH4+-N<1.0mg/L时,去除率达95%以上;当进水NH4+-N较高(1.5~4.9mg/L范围)、进水DO≤10mg/L时,去除率随进水浓度的增加而下降,最低降到30%左右.限制生物活性炭滤池硝化作用的主要因素是进水的DO,由于硝化菌与异养菌的共同竞争,在滤床0.4m深度内DO被消耗殆尽,出水DO基本为0(小于0.2mg/L),滤床被自然分成好氧区与缺氧区,在好氧区发生硝化与有机物的降解反应,在缺氧区则发生反硝化反应,由于碳源受限,反硝化反应进行得不彻底,造成滤池出水NO2--N升高.在缺氧区内除存在反硝化菌外,还存在好氧的硝化菌与异养菌.  相似文献   

6.
短程硝化生物脱氮工艺的稳定性   总被引:28,自引:6,他引:22  
采用序批式活性污泥法 (SBR)处理实际豆制品废水 ,系统研究了温度和曝气时间对短程硝化反硝化生物脱氮工艺稳定性的影响 .结果表明 ,反应器内温度只有超过 28℃时 ,利用温度实现的短程硝化反硝化生物脱氮工艺才能稳定地运行 ;另外 ,首次发现过度曝气对短程硝化影响较大 ,在过度曝气条件下运行12d ,硝化类型就由NO2--N累积率为 96 %的短程硝化转变为NO2--N累积率为39.3%的全程硝化 .因此 ,为使短程硝化反硝化生物脱氮工艺稳定、持久地运行必须实现该工艺的实时控制 .  相似文献   

7.
同步反硝化聚磷的试验研究   总被引:11,自引:3,他引:8  
采用SBR反应器和人工合成废水研究了同步反硝化聚磷的条件和影响因素.试验结果表明,厌氧/好氧方式下驯养的生物除磷污泥,在厌氧期之后供给硝酸盐,则污泥可以很快实现同步反硝化聚磷.聚磷前厌氧阶段的存在是实现反硝化聚磷必不可少的重要前提.在没有NO3-干扰而且乙酸钠为唯一碳源下,最佳厌氧时间为60min.先于缺氧期微生物接触硝酸盐,会使反硝化聚磷减弱甚至丧失.缺氧段NO3--浓度是影响反硝化聚磷效果的因素之一.在厌氧(2h)-缺氧(1h)-好氧(2h)的试验条件下,当NO3--N浓度由5mg/L上升至20mg/L时,其反硝化聚磷效率由11.9%上升至48.7%.但NO3--N浓度提高到了20mg/L以上时,其效率提高得不很明显.好氧段的存在不会使诱导形成的反硝化聚磷消失,但缩短好氧时间有助于提高DNPA在除磷中的比例.  相似文献   

8.
MBR中影响同步硝化反硝化的生态因子   总被引:40,自引:1,他引:39  
研究了DO、C/N、pH等生态因子对膜生物反应器同步硝化反硝化的影响.结果表明,只有在各生态因子保持得当的条件下,同步硝化反硝化才能顺利地进行.DO为1mg/L左右、C/N比为30左右、进水pH值约7.2左右时COD、NH4+、TN的去除率分别为96%、95%和92%.  相似文献   

9.
环流曝气塔中生物脱氮过程的研究   总被引:3,自引:0,他引:3  
利用环流曝气塔进行同时硝化/反硝化(sND)脱氮实验.实验中,分别采用不同降解性能的碳源以及采用不同的碳源投加方式,研究反应器内的脱氮过程,监测处理过程中NOx--N浓度和溶解氧DO的变化.实验显示,在COD 800mg/L+800mg/L的分批加料方式下,NH4+-N的降解得到加强,出水中NH4+-N浓度低于3mg/L;利用较难降解物质作为碳源时,利于反应器内低溶解氧条件的出现,促进了反硝化的进行,实验在采用醇类碳源时脱氮效果好于葡萄糖的情况.  相似文献   

10.
A2N系统中低碳污水的反硝化除磷优化及运行稳定性   总被引:2,自引:1,他引:1  
张耀斌  邢亚彬  秦四飞  全燮  陈硕 《环境科学》2011,32(4):1020-1026
采用序批式生物移动床(SBMBBR),通过优化反应条件可以取得较高的聚-β-羟基丁酸盐(PHB)富集效率,通过双泥系统的操作,可以实现低碳下的高效反硝化除磷.在进水COD 200 mg/L、pH为中性的生活污水中,并在搅拌速度为80 r/min下,磷的去除率达到83.7%,NO-3-N的去除率达到81.4%,NO-2-N的去除率接近100%,取得较好的反硝化除磷作用.较大的生物量是保证较高效率的反硝化除磷的关键之一.采用双泥系统运行SBMBBR,可以获得稳定的、较高效率的脱氮除磷.在COD为140~170 mg/L, TN为34~42 mg/L低碳氮比的实际废水处理中,磷的去除率达到89.2%,TN的去除率达到84.5%.在处理过程中,排泥中的磷量基本与进水中磷的量一致,未发现磷的其它去除路径.  相似文献   

11.
厌氧-好氧序列间歇式反应器处理生物制药废水的研究   总被引:21,自引:0,他引:21  
采用厌氧序列间歇反应器与好氧序列间歇反应器相结合的技术,处理生物制药废水。结果表明,经7.0h厌氧搅拌处理和6.0h好氧曝气处理,进水COD为1180~3061mg/L,出水COD小于300mg/L,COD去除率在78.9%~92.8%之间,出水COD满足国家生物制药行业废水排放标准要求。   相似文献   

12.
为了考察氮磷同时缺乏对活性污泥系统的影响,采用2个序批式间歇反应器(SBR),按照缺氧/好氧的方式平行运行,通过调节不同的进水COD/N/P比,考察了氮磷同时缺乏状态下活性污泥系统的污泥沉降性、絮体形态、出水水质以及比耗氧速率等方面的表现。结果表明,在氮磷同时缺乏时,当进水COD/N/P比为100/2/0.4时,活性污泥系统会发生丝状菌膨胀,而当进水COD/N/P为100/0.5/0.1时,污泥沉降性保持良好;各反应器的活性污泥浓度均在逐渐地下降,MLSS由约2200mg/L下降至1800mg/L以下;各反应器的比耗氧速率均呈现逐渐上升的趋势,COD的去除率呈现逐渐下降的趋势。  相似文献   

13.
The impact of the organic carbon to nitrogen ratio (chemical oxygen demand (COD)/N) in wastewater and dissolved oxygen (DO) concentration on carbon and nitrogen removal efficiency, and total bacteria and ammonia-oxidizing bacteria (AOB) communities in activated sludge in constantly aerated sequencing batch reactors (SBRs) was determined. At DO of 0.5 and 1.5 mg O2/L during the aeration phase, the efficiency of ammonia oxidation exceeded 90%, with nitrates as the main product. Nitrification and denitrification achieved under the same operating conditions suggested the simultaneous course of these processes. The most effective nitrogen elimination (above 50%) was obtained at the COD/N ratio of 6.8 and DO of 0.5 mg O2/L. Total bacterial diversity was similar in all experimental series, however, for both COD/N ratios of 6.8 and 0.7, higher values were observed at DO of 0.5 mg O2/L. The diversity and abundance of AOB were higher in the reactors with the COD/N ratio of 0.7 in comparison with the reactors with the COD/N of 6.8. For both COD/N ratios applied, the AOB population was not affected by oxygen concentration. Amplicons with sequences indicating membership of the genus Nitrosospira were the determinants of variable technological conditions.  相似文献   

14.
A new anaerobic reactor, Jet-loop anaerobic fluidized bed (JLAFB), was designed for treating high-sulfate wastewater. The treatment characteristics, including the effect of influent COD/SO42 ratio and alkalinity and sulfide inhibition in reactors, were discussed for a JLAFB and a general anaerobic fiuidized bed (AFB) reactor used as sulfate-reducing phase and methane-producing phase, respectively, in two-phase anaerobic digestion process. The formation of granules in the two reactors was also examined. The results indicated that COD and sulfate removal had different demand of influent COD/SO4^2- ratios. When total COD removal was up to 85%, the ratio was only required up to 1.2, whereas, total sulfate removal up to 95% required it exceeding 3.0. The alkalinity in the two reactors increased linearly with the growth of influent alkalinity. Moreover, the change of influent alkalinity had no significant effect on pH and volatile fatty acids (VFA) in the two reactors. Influent alkalinity kept at 400-500 mg/L could meet the requirement of the treating process. The JLAFB reactor had great advantage in avoiding sulfide and free-H2S accumulation and toxicity inhibition on microorganisms. When sulfate loading rate was up to 8. 1 kg/(m^3.d), the sulfide and free-H2S concentrations in JLAFB reactor were 58.6 and 49.7 mg/L, respectively. Furthermore, the granules, with offwhite color, ellipse shape and diameters of 1.0-3.0 mm, could be developed in JLAFB reactor. In granules, different groups of bacteria were distributed in different layers, and some inorganic metal compounds such as Fe, Ca, Mg etc. were found.  相似文献   

15.
采用厌氧-好氧序列间歇反应器-混凝沉淀组合工艺,处理碱法草浆造纸中段废水。结果表明,经8.0h厌氧搅拌处理和5.0h好氧曝气处理,进水CODcr为729.1-2239mg/L,出水CODCr小于550mg/L,CODCr去除率在66.2%-76.3%之间,再经混凝沉淀处理,出水CODCr小于200mg/L,色度小于50倍,满足国家造纸工业水污染物排放标准中的二级标准。  相似文献   

16.
焦化废水生物流化床系统脱氮中试研究   总被引:6,自引:0,他引:6  
杨平  王彬  石炎福 《环境工程》2002,20(4):14-17
以厌氧流化床、缺氧流化床作生物反应器 ,聚合物多孔高分子颗粒作微生物固定化载体 ,采用厌氧 缺氧 好氧工艺进行了焦化废水处理中试研究。结果表明 :当系统稳定运行时 ,进水NH3 N、CODCr、酚平均浓度为 5 39 5mg L、14 88mg L、2 4 7 7mg L时 ,出水NH3 N、CODCr酚平均浓度分别为 14 3mg L、2 5 2 4mg L、0 2mg L ;厌氧流化床、缺氧流化床反应器中存在厌氧氨氧化反应 ,在这 2个阶段NH3 N分别去除 9 8%和 3 3%。该生物流化床系统脱氮技术对现有焦化废水活性污泥法处理系统的改造具有指导意义  相似文献   

17.
许英杰 《环境工程》2009,27(5):33-35
对生产性IC反应器处理酒精废水的启动过程及其处理效率进行研究。当进水COD浓度为15 000 mg/L条件下,出水COD仅有500 mg/L左右,COD去除率在95%以上。在反应器启动初期曾因操作失误出现酸化现象,后来经过投加NH4HCO3和厌氧出水中和调节pH,反应器内部环境得到一定的改善,到启动结束时,两个反应器内pH均稳定在6.8左右,VFA也下降到400 mg/L左右。  相似文献   

18.
水解酸化-SBR工艺处理印染废水的研究   总被引:16,自引:0,他引:16  
用水解酸化-SBR工艺处理印染废水的实验结果表明,出水COD平均为102mg/L,COD去除率平均为89.9%,色度去除率平均为70%.在实际工程中应用水解酸化(A)-好氧(O)-SBR工艺处理印染废水,出水COD平均为67mg/L,COD去除率平均为81.5%,色度去除率平均为66.7%.表明以水解酸化为预处理手段可有效提高印染废水的可生化性,提高整个工艺的COD去除率.  相似文献   

19.
以乙酸钠和丙酸钠1:2混合作为碳源,进水COD浓度分别为200,400,600,800mg/L,研究混合碳源浓度对单级好氧生物脱氮除磷的影响,并通过比较微生物体内储能物质的变化,探讨混合碳源浓度对生物脱氮除磷性能影响的机理.结果表明,当进水磷和氨氮浓度分别为12,30mg/L时,随着进水COD由200增加至800mg/L,磷去除率由39.9%提升至86.4%(氮去除率从13.5%提升至96.4%).进水COD为400mg/L时单位挥发性悬浮固体(VSS)的磷和氮去除量达到最高[分别为(4.31±0.08)和(6.15±0.22)mg/g].当进水COD由200增加至400mg/L时生物除磷活性增强,而COD继续增加会使污泥沉降性能变差,脱氮除磷生物活性降低.好氧吸磷和同步硝化反硝化主要由微生物体内储能物质多β羟基烷酸盐(PHA)驱动,当进水COD为400mg/L时单位VSS消耗的PHA最多.混合碳源浓度通过影响碳源的好氧代谢,使微生物体内储能物质的积累/转化量不同,进而影响系统的脱氮除磷性能.  相似文献   

20.
High strength refractory organic stream is produced during the production of 2-phenylamino-3-methyl-6-di-n-butylaminofluoran (One Dye Black 2, abbr. ODB 2), a novel heat-sensitive material with a promising market. In this study, a combination of acidificationprecipitation, primary biological treatment, Fenton's oxidation and another biological treatment was successfully used for the removal of COD from 18000-25000 mg/L to below 200 mg/L from the ODB 2 production wastewater in a pilot experiment. A COD removal of 70%-80% was achieved by acidification-precipitation under a pH of 2.5-3.0. The first step biodegradafion permitted an average COD removal of 70% under an hydraulic residence time (HRT) of 30 h. By batch tests, the optimum conditions of Fenton's oxidation were acquired as: Fe^2+ dose 6.0 mmol/L; H2O2 dose 3000 mg/L; and reaction time 6 h. The second step biological treatment could ensure an effluent COD below 200 mg/L under an HRT of 10 h following the Fenton's treatment.  相似文献   