首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
This paper investigates the prediction of solar radiation model and actual solar energy in Osmaniye, Turkey. Four models were used to estimate using the parameters of sunshine duration and average temperature. In order to obtain the statistical performance analysis of models, the coefficient of determination (R2), mean absolute percentage error (MAPE), mean absolute bias error (MABE), and root mean square error (RMSE) were used. Results obtained from the linear regression using the parameters of sunshine duration and average temperature showed a good prediction of the monthly average daily global solar radiation on a horizontal surface. In order to obtain solar energy, daily and monthly average solar radiation values were calculated from the five minute average recorded values by using meteorological measuring device. As a result of this measurement, the highest monthly and yearly mean solar radiation values were 698 (April in 2013) and 549 (2014 year) W/m2 respectively. On an annual scale the maximum global solar radiation changes from 26.38 MJ/m2/day by June to 19.19 MJ/m2/day by September in 2013. Minimum global solar radiation changes from 14.05 MJ/m2/day by October to 7.20 MJ/m2/day by January in 2013. Yearly average energy potential during the measurement period was 16.53 MJ/m2/day (in 2013). The results show that Osmaniye has a considerable solar energy potential to produce electricity.  相似文献   

2.
Daily global solar radiation on a horizontal surface and duration of sunshine hours have been determined experimentally for five meteorological stations in Saudi Arabia, namely, Abha, Al-Ahsa, Al-Jouf, Al-Qaisumah, and Wadi Al-Dawaser sites. Five-years of data covering 1998–2002 period have been used. Suitable Angstrom models have been developed for the global solar radiation estimation as a function of the sunshine duration for each respective sites. Daily averages of monthly solar PV power outputs have been determined using the Angstrom models developed. The effect of the PV cell temperature on the PV efficiency has been considered in calculating the PV power output. The annual average PV output energy has been discussed in all five sites for small loads. The minimum and maximum monthly average values of the daily global solar radiation are found to be 12.09 MJ/m2/d and 30.42 MJ/m2/d for Al-Qaisumah and Al-Jouf in the months of December June, respectively. Minimum monthly average sunshine hours of 5.89 hr were observed in Al-Qaisumah in December while a maximum of 12.92 hr in Al-Jouf in the month of June. Shortest range of sunshine hours of 7.33–10.12 hr was recorded at Abha station. Minimum monthly average Solar PV power of 1.59 MJ/m2/day was obtained at Al-Qaisumah in the month of December and a maximum of 3.39 MJ/m2/day at Al-Jouf in June. The annual PV energy output was found to be 276.04 kWh/m2, 257.36 kWh/m2, 256.75 kWh/m2, 245.44 kWh/m2, and 270.95 kWh/m2 at Abha, Al-Ahsa, Al-Jouf, Al-Qaisumah, and Wadi Al-Dawaser stations, respectively. It is found that the Abha site yields the highest solar PV energy among the five sites considered.  相似文献   

3.
This study investigates the wind and solar electricity generation availability at the Solar Energy Institute of Ege University, Izmir, Turkey. The main purpose of this study is to design an appropriate wind-PV hybrid system to cover the electricity consumption of the Institute. In order to do this, monthly average solar irradiation and wind speed data are used, which were measured, consisting of hourly records over an eight-year period from 1995–2002. Simple models were developed to determine wind, solar, and hybrid power resources per unit area. Correlations between the solar and wind power data were carried out on an hourly, daily, and monthly basis. It is shown that the hybrid system can be applied for the efficient and economic utilization of these resources.  相似文献   

4.
ABSTRACT

Remote communities in the North of Ontario survive in isolation as their proximity to the southern industrial sector of the province limits their accessibility to the major grid. The lack of grid connection has led to antiquated methods of power generation which pollute the environment and deplete the planet of its natural resources. Aside from the primary means of electricity generation being by diesel generators, generation infrastructure is deteriorating due to age and the stagnation of the power supply has led to communities facing load restrictions. These challenges may be resolved by introducing clean energy alternatives and providing a fuel blend option. The primary energy sources investigated in this research are solar, wind, and hydrogen. To assess the viability of these energy production methods in Northern communities, an exergy analysis is employed as it utilizes both the first and second law of thermodynamics to determine systems’ efficiency and performance in the surroundings. Local weather patterns were used to determine the viability of using wind turbines, solar panels and/or hydrogen fuel cells in a remote community. Through analysis of the resources available at the community, it was determined that the hydrogen fuel cell was best suited to provide clean energy to the community. Wind resulted in low efficiency in the range of 2–3% while solar efficiencies resulted in ranges of 18 – 19%, as the seasonal variations between the three years is not very great. Due to the higher operating efficiencies observed of the PV panels it would also be an attractive alternative to diesel generators however, the lack of consistent operation above 30% efficiency throughout the year, resulted in hydrogen fuel cells being a better alternative.  相似文献   

5.
Conventional solar photovoltaic (PV) module converts the light component of solar radiation into electrical power, and heat part is absorbed by module increasing its operating temperature. Combined PV module and heat exchanger generating both electrical and thermal powers is called as hybrid photovoltaic/thermal (PV/T) solar system. The paper presents the design of a PV/T collector, made with thin film PV technology and a spiral flow absorber, and a simulation model, developed through the system of several mathematical equations, to evaluate the performance of PV/T water collectors. The effect of various parameters on the thermal and electrical efficiency has been investigated to obtain optimum combination of parameters. Finally, a numerical simulation has been carried out for the daily and annual yield of the proposed PV/T collector, and comparison with a standard PV module is discussed.  相似文献   

6.
The increasing capacity of distributed electricity generation brings new challenges in maintaining a high security and quality of electricity supply. New techniques are required for grid support and power balance. The highest potential for these techniques is to be found on the part of the electricity distribution grid.

This article addresses this potential and presents the EEPOS project’s approach to the automated management of flexible electrical loads in neighborhoods. The management goals are (i) maximum utilization of distributed generation in the local grid, (ii) peak load shaving/congestion management, and (iii) reduction of electricity distribution losses. Contribution to the power balance is considered by applying two-tariff pricing for electricity.

The presented approach to energy management is tested in a hypothetical sensitivity analysis of a distribution feeder with 10 households and 10 photovoltaic (PV) plants with an average daily consumption of electricity of 4.54 kWh per household and a peak PV panel output of 0.38 kW per plant. Energy management shows efficient performance at relatively low capacities of flexible load. At a flexible load capacity of 2.5% (of the average daily electricity consumption), PV generation surplus is compensated by 34–100% depending on solar irradiance. Peak load is reduced by 30% on average. The article also presents the load shifting effect on electricity distribution losses and electricity costs for the grid user.  相似文献   


7.
Solar photovoltaic (PV) cells are used to resolve energy security and climate change problems. Although PV panels have long physical lifetimes, they would be eventually replaced by new ones with higher energy efficiency and then changed to waste. Depending on the types of PV cells, waste PV panels have different environmental impact potentials due to different contents of substances. This study assesses and compares hazardous waste, resource depletion, and toxicity potentials from metals in three types of PV modules (i.e., polycrystalline silicon (Si), amorphous Si, and CIGS (copper/indium/gallium/di-selenite) PVs) on per-watt electricity generation basis. Hazardous waste potentials are examined by using metal leachability tests, and resource depletion and toxicity potentials are evaluated by using life cycle impact assessment methods. The polycrystalline Si and CIGS PVs have hazardous waste potentials due to lead (Pb) and cadmium/selenium, respectively, whereas the amorphous Si PV does not. The polycrystalline Si PV has the highest resource depletion potential due primarily to silver; the CIGS PV has the next highest due primarily to selenium; and the amorphous Si PV had the lowest, which is derived primarily from tin and copper. For toxicity potentials, overall the amorphous Si PV had lower potentials, derived primarily from barium/copper/nickel/zinc, than the polycrystalline Si and CIGS PVs of which the toxicity potentials were primarily form copper/lead/nickel/silver and copper/mercury/molybdenum/nickel/silver, respectively. Therefore, waste polycrystalline Si and CIGS PV panels should be recycled and managed with priority, and PV technology development needs to be directed to amorphous Si PV from the material perspective.  相似文献   

8.
Theoretical model of a solar photovoltaic integrated water-Lithium bromide absorption system is presented for domestic air conditioning. Surplus electrical energy from photovoltaic modules is used for charging the battery, which is utilized during the periods of zero or insufficient solar radiation. Minimum solar area required for each month is calculated and October is identified as the month requiring the highest area of photovoltaic arrays for a constant cooling load of 3.5 kW. The integrated system is found to be capable of sufficient amount of surplus electrical energy generation during both summer and winter months, with a daily excess of about 815 Ah of electrical energy on average over a complete calendar year. Designed system is found to be economically viable, having an energy payback period of 2.7 years.  相似文献   

9.
太阳能光伏发电成本及展望   总被引:1,自引:0,他引:1  
针对太阳能电池的昂贵发电成本,分析和预测了国内外的太阳能光伏产业链的现状与发展;指出研制高效率、低成本太阳能光伏发电系统将是今后的任务。  相似文献   

10.
Considering successive and costly increases in electricity rates, this article evaluates the generation of electricity from a photovoltaic system using solar energy, a renewable source. The solar photovoltaic system is installed at UNIVATES University Center, a public university in the state of Rio Grande do Sul, Brazil, and it is also connected to the electrical grid. Data related to the climatic conditions of the location, such as incident solar radiation, rainfall, and mean temperature, were obtained during the system's evaluation period and used along with bibliographic research on similar systems installed in southern Brazil. Our study quantified the energy produced over one calendar year (2014) and related it to the climatic variables and the conversion efficiency achieved by the system's photovoltaic modules. Our results show that there is both a strong relationship between the production of energy and climatic conditions and that the city, Lajeado, and the Brazilian state of Rio Grande do Sul, have good potential to supply energy using photovoltaic systems connected to the electrical grid. The horizontal global solar radiation average obtained in the study location was 4.14 kilowatts per square meter per day (kWh/m2/day), and the average monthly production of energy reached 243.93 kWh/m2/month, with a total of 2,927.10 kWh produced in 2014, achieving a monthly average conversion efficiency of 11.07%. This conversion efficiency is close to the value of 12.6% obtained in 2013 in a similar study of the same solar photovoltaic system conducted over a shorter time period.  相似文献   

11.
An ideal off-grid island can become 100% energy-sufficient if one installs renewable energy systems such as solar photovoltaic (PV) and wind turbine (WT) systems. However, the intermittent and uncertain nature of the power supply from renewable energy systems hinders a 100% autonomy level (AL) without an infinite energy storage capacity. The thermoeconomic installation limit (TEIL) of a PV/WT hybrid energy system was studied using hourly weather data and the energy demand profile for off-grid islands. An appropriate battery size for the TEIL was also determined. Given the current installation cost of the hybrid energy system and the battery unit, the AL for a PV/WT hybrid energy system at the TEIL is calculated to be approximately 70%. Above the limit, the size of the energy storage unit and, correspondingly, the total annual cost of the PV/WT hybrid energy system increase sharply.  相似文献   

12.
In this study, the optimal sizing and performance analysis of a standalone integrated solar power system equipped with different storage scenarios to supply the power demand of a household is presented. One of the main purposes when applying solar energy resource is to face the increasing environmental pollutions resulting from fossil fuel based electricity sector. To this end, and to compare and examine two energy storage technologies (battery and hydrogen storage technology), three storage scenarios including battery only, hydrogen storage technology only and hybrid storage options are evaluated. An optimization framework based on Energy Hub concept is used to determine the optimum sizes of equipment for the lowest net present cost (NPC) while maintaining the system reliability. It was determined that the most cost effective and reliable case is the system with hybrid storage technology. Also, the effects of solar radiation intensity, the abatement potential of CO2 emissions and converting excess power to hydrogen on the system’s performance and economics, were investigated and a few noticeable findings were obtained.  相似文献   

13.
A combined photovoltaic–thermal (PV/t) panel is proposed to produce simultaneously electricity and heat from one integrated unit. The unit utilizes effectively the solar energy through achieving higher PV electrical efficiency and using the thermal energy for heating applications. To predict the performance of the PV/t at a given environmental conditions, a transient mathematical model was developed. The model was integrated in a heating application for a typical office space in the city of Beirut to provide the office needs for electricity, heating during winter season, and dehumidification and evaporative cooling during the summer season. To minimize the yearly office energy (electrical and heat) needs, the PV/t panel cooling air flow rate and the dehumidification regeneration temperature were determined for opimal unit operation. Thermal energy savings of up to 85% in winter and 71% in summer were achived compared to conventional systems at a payback period of 8 years for the panels.  相似文献   

14.
The solar chimney power plant (SCPP) is a power generator which uses solar radiation to increase the internal energy of the air circulating in the system, thereby transforming the useful gain of the solar collector into kinetic energy. The produced kinetic energy then can be converted into electrical energy by means of an appropriate turbine. In this paper, four locations in Algeria

(Constantine, Ouargla, Adrar, and Tamanrasset) were considered as case studies to describe the SCPP mechanism in detail. Numerical simulation of an SCPP which has the same geometrical dimensions was performed to estimate the power output of SCPP in these regions. Using the CFD software FLUENT we simulated a two-dimensional axisymmetric model of a SCPP with the standard k-ε turbulence model. The simulation results show that the highest power output produced monthly average value 68–73 KW over the year and the highest hourly power produced in June is around 109–113 KW.  相似文献   


15.
The ISCC technology representing an integrated solar combined cycle and the economic assessment of ISCC are investigated. Comparisons conducted by theoretical calculation method among two cases, that is, an integrated solar combined cycle system (ISCCS) and a combined cycle gas turbine system (CCGTS) show that ISCCS provides the best solution with the highest efficiency of heat to electricity among them. The results reflected by theoretical calculation also reveal that ISCCS is beneficial to energy saving and emission reduction. Due to the great advantages of ISCC, comprehensive analysis on the basic conditions for building ISCC power plants is analyzed in detail.  相似文献   

16.
王茹静 《四川环境》2014,(1):119-123
大多数内陆核电厂将采用大型自然通风冷却塔作为其二次循环冷却方式,本文基于美国核管会推荐的SACTI程序,给出了该模型的基本原理和框架结构,并以江西彭泽核电厂为例,采用该程序预测分析了该核电厂大型自然通风冷却塔所造成的雾羽和太阳辐射损失的影响。并进一步研究了不同环境风速、相对湿度条件下对冷却塔造成的太阳辐射损失的影响。SACTI模型可以根据厂址逐时气象观测数据,较好地计算可见雾羽的长度、抬升高度和太阳辐射损失,其结果可以作为冷却塔环境影响评价的依据。  相似文献   

17.
The solar radiation data are of high importance to the solar energy systems. Conventional methods to obtain the solar radiation data are from weather stations, solar radiation models, commercial software databases, and field measurements. In the present study, a new daily global solar radiation model is proposed, by combining the quadratic function of sunshine fraction and sine function of the day of the year. The solar radiation model calculated data are then compared with China Meteorological Data Sharing System (CMDSS) data, TRNSYS data, and field-measured data in Northwest China climate. It is found that the newly proposed solar radiation model has better performance than the other nine solar radiation models in the literature. The solar radiation model calculated data fit well with the CMDSS annually average data. The TRNSYS data are a bit larger than the CMDSS annually average data in summer half year and a little smaller than those in winter half year. The solar radiation model and the CMDSS annually average data have the best correlation, whereas the TRNSYS data and the field-measured data have the worst correlation. The solar radiation model calculated data have the best correlation with the other three data sources.  相似文献   

18.
The solar energy received by a flat plate collector is calculated for various tracking modes: fixed, inclination depending on the season or the month; variable inclination with fixed azimuth, variable azimuth with fixed inclination and double tracking. At first, we take into account only the sun position and then, we use validated radiation models for estimating the ground solar radiation. Using a tracker is questionable particularly if the additional costs are taken into account. A good solution to increase the available solar energy is to change seasonally the inclination, that is, 4 times per year.  相似文献   

19.
Solar radiation is a major sustainable and clean energy resource, and use of solar radiation is expected to increase. The utilization efficiency of solar energy varies with the relative proportions of the direct and diffuse components that compose total solar radiation and with the slope and aspect of the irradiated surface. The purpose of this paper is to develop a simple method for estimating diffuse and direct solar radiation at sites with observation of only total solar radiation. An existing model for estimating diffuse radiation, i.e., a linear relationship between the diffuse fraction (the ratio of diffuse radiation to total solar radiation) and the clearness index (the ratio of total solar radiation to extraterrestrial radiation), is applied to 7 sites across the continental United States with observations of diffuse and total radiation. The linear model shows good monthly performance. The model parameters (slope and interception) show a strong seasonal pattern that exhibits small variation across the 7 sites; therefore, the average values of the two monthly parameters may be used for estimating diffuse radiation for other locations with observations of total radiation.  相似文献   

20.
The heat-pipe solar water heating (HP-SWH) system and the heat-pipe photovoltaic/thermal (HP-PV/T) system are two practical solar systems, both of which use heat pipes to transfer heat. By selecting appropriate working fluid of the heat-pipes, these systems can be used in the cold region without being frozen. However, performances of these two solar systems are different because the HP-PV/T system can simultaneously provide electricity and heat, whereas the HP-SWH system provides heat only. In order to understand these two systems, this work presents a mathematical model for each system to study their one-day and annual performances. One-day simulation results showed that the HP-SWH system obtained more thermal energy and total energy than the HP-PV/T system while the HP-PV/T system achieved higher exergy efficiency than the HP-SWH system. Annual simulation results indicated that the HP-SWH system can heat the water to the available temperature (45°C) solely by solar energy for more than 121 days per year in typical climate regions of China, Hong Kong, Lhasa, and Beijing, while the HP-PV/T system can only work for not more than 102 days. The HP-PV/T system, however, can provide an additional electricity output of 73.019 kWh/m2, 129.472 kWh/m2, and 90.309 kWh/m2 per unit collector area in the three regions, respectively.  相似文献   