首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 33 毫秒
1.
Five methods for aluminium fractionation used in different laboratories in Norway and Finland were compared using six control, 75 soil water and 10 lake water samples. Different fractionation principles [cation exchange, formation of the Pyrocatechol Violet (PCV) or quinolin-8-ol (oxine) complex], types of cation exchanger [Amberlite (Na/H) or Bond Elut (H)], reaction time (from 2.3 s), flow systems (flow injection analysis or segmented flow) and determination principles (molecular absorption spectrometry or ICP-AES) were tested. Determination of the 'labile' fraction was strongly dependent on the method used and the largest differences were observed between the ICP-AES method with cation exchange (Bond Elut H form) and the 'quickly reacting' method (oxine, 2.3 s). Different flow systems, both using cation exchange and determination of the PCV complex but with different reaction times and an extra acidification step, resulted in large differences in the 'reactive' and 'non-labile' fractions determined. However, the determination of the labile fraction gave similar results with both these methods. The two different types of cation exchanger used (with and without pH buffering and with different counter ions) in the ICP-AES methods resulted in differences, mainly because of a smaller 'non-labile' fraction in the non-buffered system. The two flow injection systems (oxine and PCV complexation) showed common trends, which may be connected with the short reaction times used. Comparison with theoretical equilibrium calculations using the model ALCHEMI suggested that the best correlation for the determination of the 'labile' fraction were obtained with the ICP-AES method with an Amberlite column.  相似文献   

2.
A simple, sensitive, and accurate UV spectrophotometric method has been developed for the determination of nickel in synthetic mixture and water samples. The method is based on the complexation reaction of nickel ion with cefixime, thus leading to the formation of Ni–cefixime complex in ethanol-distilled water medium at room temperature. The complex showed the maximum absorption wavelength at 332 nm. Beer’s law is obeyed in the working concentration range of 0.447–4.019 μg?mL?1 with apparent molar absorptivity of 7.314?×?103?L?mol?1?cm?1 and Sandell’s sensitivity of 0.008 μg/cm2/0.001 absorbance unit. The limits of detection and quantitation for the proposed method are 0.016 and 0.054 μg?mL?1, respectively. The factors such as cefixime concentration and solvent affecting the complexation reaction were carefully studied and optimized. The method is validated as per the International Conference on Harmonisation guideline. The method is successfully applied to the determination of Ni(II) in synthetic mixture and wadi water samples collected from Al Rustaq. The same water samples are also analyzed by atomic absorption spectrophotometry. Both methods determined the amount of Ni(II) in water sample and found to be approximately the same.  相似文献   

3.
A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.  相似文献   

4.
研究了不同分析方法、去浊度手段和预处理方式对地表水总磷测定的影响。结果表明:钼酸铵分光光度法在跨界水体联合监测中较连续流动分析法、氯化亚锡还原光度法、孔雀绿-磷钼杂多酸分光光度法更为适用;在水样没有色度的情况下,采用浊度-色度补偿法和离心法都能有效消除浊度干扰,相对误差±10%;预处理方式的不同是导致各监测单位测定结果可比性差的最关键因素。  相似文献   

5.
A new, simple, sensitive, and selective spectrophotometric method for the determination of copper in water and soil samples has been demonstrated. The method is based on the reaction of Cu(I) with neocuproine (2,9-dimethyl-1, 10-phenanothroline) and extracted with N-phenyl benzimidoylthiourea in chloroform. The value of molar absorptivity of the complex in the term of Cu(I) is 1.45 × 105 L mol???1 cm???1 at λ max 460 nm in chloroform. The detection limit of copper in water and soil is 2 ng mL???1 and 4 ng g???1, respectively. The method is free from the interference of the ions commonly found to be associated with the copper determination in water and soil samples. The application of the proposed method has been successfully tested for the determination of copper in different types of water and soil samples.  相似文献   

6.
This study describes the determination of trace levels of copper by slotted quartz tube atomic absorption spectrometry after dispersive liquid-liquid microextraction. A ligand synthesized from the reaction of salicylaldehyde and 1-naphthylamine was used to form coordinate copper complex prior to extraction. All parameters that influence the output of complex formation, extraction, and instrumental measurement were optimized to enhance the absorbance signal of copper. Under the optimum conditions, about 104-fold enhancement in sensitivity was recorded over the conventional flame atomic absorption spectrometer, corresponding to a 0.51 ng/mL detection limit. The percent relative standard deviation calculated for the lowest concentration (4.8%) indicated high precision for the experimental procedure. Accuracy and applicability of the optimum method were determined by performing spiked recovery tests on urine, lake water, and mineral water samples. Satisfactory recovery results were obtained between 82.2 and 106.3% at four different concentrations. Matrix matching method was also performed to increase the accuracy of quantification, and the percent recovery calculated for 175 ng/mL was 105.14%.  相似文献   

7.
A new electrochemical adsorptive stripping voltammetry method was developed for the determination of trace amounts of copper in food and water samples. The study of electrochemical behavior of Cu ion indicated that Cu(II) and Schiff base formed a complex in H3BO4–NaOH buffer solution (pH?=?7.25). An accumulation potential of ?100 mV (vs Ag/AgCl) was applied while the solution was stirred for 60 s. The response curve was recorded by scanning the potential, and the peak current of ?0.31 V (vs Ag/AgCl) was recorded. The peak current and concentration of copper accorded with linear relationship in the range of 0.04–120 ng mL?1. The relative standard deviation (for 12 ng mL?1 of copper) was 1.73 %, and the detection limit was 0.007 ng mL?1. The possible interference of some common ions was studied. The proposed method was applied to the determination of copper in water, rice, wheat, tea, milk, and tomato with satisfactory results.  相似文献   

8.
合成了新试剂4-(H-酸偶氮)1-苯基-3-甲基吡唑酮(HPMP),研究了其和铜的显色反应。在pH=7的NH4Ac缓冲介质中,CTMAB存在下,HPMP与Cu(Ⅱ)生成2∶1紫色络合物,λmax=580nm,ε=5.68×104L·mol-1·cm-1。铜含量在0~0.6mg/L内符合比耳定律。方法用于水样和生物样品中铜的测定,结果令人满意。  相似文献   

9.
N,N-dibutyl-N1-benzoylthiourea (DBBT) impregnated onto a polymeric matrix, Amberlite XAD-16 was prepared. The separation and enrichment of Ag(I) from solution was investigated. Effective extraction conditions were optimized in column methods prior to determination by atomic absorption spectrometry. The optimum pH range for quantitative adsorption is 2-5. Quantitative recovery of Ag was achieved by stripping with 1 mol L(-1) thiourea in 1 mol L(-1) HCl. The sorption capacity of resin is 0.115 mmol Ag+ g(-1) resin. The relative standard deviation and detection limit was 3.1% for 1 microg Ag+ mL(-1) solution and 0.11 microg L(-1), respectively. The method was used for the determination of silver in geological water samples.  相似文献   

10.
气相分子吸收光谱法测定成分复杂氨氮实际样品时,干扰因素造成测定结果不准确,而现有的标准方法和文献对干扰物质的研究不全面,制约了仪器的应用。该文系统地开展干扰因素的研究,提出干扰因素的消除方法,用加标回收率验证消除的有效性。结果表明,亚硫酸盐、硫化物等还原性物质对测定产生负干扰;石油烃、N,N-二甲基甲酰胺(DMF)等挥发性有机物、有机胺类以及亚硝酸盐对测定产生正干扰。根据不同干扰类型,通过加入适量酸性重铬酸钾溶液、在酸性条件下加热煮沸、预蒸馏等方法可消除干扰,消除干扰后加标回收率为84%~120%。生活污水、石化企业废水等6种典型水样消除干扰后,气相分子吸收光谱法和纳氏试剂分光光度法测定氨氮有较好的可比性,干扰消除方式有效。  相似文献   

11.
A new method for the determination of iron, cobalt, nickel, copper, zinc and manganese in drinking water by the reversed-phase high-performance liquid chromatography (RP-HPLC) with 2-(2-quinolinylazo)-5-diethylaminophenol (QADEAP) as precolumn derivatizing reagent was studied in this paper. The iron, cobalt, nickel, copper, zinc, and manganese ions react with QADEAP to form color chelates in the presence of cetyl trimethylammonium bromide (CTMAB) and acetic acid-sodium acetic buffer solution medium of pH 4.0. These chelates were enriched by solid-phase extraction with a Waters Nova-Pak C18 cartridge and eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The enrichment factor of 100 was achieved. Then the chelates were separated on a Waters Nova-Pak C18 column (3.9 x 150 mm, 5 microm) by gradient elution with methanol (containing 0.2% of acetic acid and 0.1% of CTMAB) and 0.05 mol L(-1) acetic acid-sodium acetic buffer solution (containing 0.1% of CTMAB) (pH 4.0) as mobile phase at a flow rate of 0.5 ml min(-1), and monitored with a photodiode array detector from 450 approximately 700 nm. The detection limits (S/N = 3) of iron, cobalt, nickel, copper, zinc and manganese are 0.8, 1.1, 0.9, 1.1, 1.5 and 2.0 ng L(-1), respectively, in the original sample. This method can be applied to determination at the microg L(-1) level of iron, cobalt, nickel, copper, zinc and manganese in drinking water with good results.  相似文献   

12.
This study reports a very selective, easy, and precise method for rapid separation of trace amounts of copper in aqueous samples using octadecyl silica-bonded phase membrane disks modified by 2,2'-[ethane-1,2-diylbis(thio)]dianiline (EDTD) combined with flame atomic absorption spectrometric determination. In addition, the synthesis and spectral characterization of EDTD have been described in detail. All the affecting experimental variables such as pH, amount of modifier, eluent type, sample and eluent flow rate, interfering ions, and disk capacity were also investigated. The target analyte (trace copper) was quantitatively retained at pH?=?4 and eluted with 6.0 mL of 0.5 M HNO3 at flow rates of 40 and 10 mL min?1 for analyte passage and elution steps, respectively, through the disks modified with 17.0 mg of EDTD. The proposed method also allows an enrichment factor of about 500 and has a detection limit of 0.005 ng mL?1. The method has been successfully applied for isolation and determination of copper in different water samples, peppers, and standard alloys.  相似文献   

13.
Changes in chemical speciation of copper and the capacity of concrete pavement to retain copper in runoff water from external buildings have been investigated at urban field conditions, and in parallel laboratory experiments simulating outdoor scenarios. The research study showed the concrete surface to form a copper rich surface layer (≈50 μm thick) upon exposure, and a high capacity to significantly reduce the bioavailable fraction of released copper (20–95%). The retention capacity of copper varied between 5 and 20% during single runoff events in the laboratory, and between 10 and 40% of the total copper release during single natural runoff events. The capacity to retain and reduce the bioavailable fraction of non-retained copper increased with increasing wetness of the concrete surfaces, increasing pH of the runoff water and decreasing flow rates. Bioassay testing with bacterial and yeast bioreporters showed the bioavailable fraction of non-retained copper to be significantly lower than the total copper concentration in the runoff water, between 22 and 40% for bacteria and between 8 and 31% for yeast. The application of generated data to simulate a fictive outdoor scenario, suggests a significant reduction of bioavailable and total copper to background values during environmental entry as a result of dilution, and the interaction with solid surfaces, organic matter and complexing agents already in the drainage system.  相似文献   

14.
A simple and sensitive method was developed for determination of trace copper by direct precipitation preconcentration and detection with Flame Atomic Absorption Spectrometry (FAAS). The reagent 2-[2'-(6-methyl-benzothiazolylazo)]-4-aminophenol (Me-BTAP) was used as precipitating agent. The experimental conditions for the quantitative precipitation of copper, such as pH, amount of reagents, temperature and the effect of diverse ions on the precipitation have been investigated. It was found that copper is quantitatively extracted (> or =95%) and the method provides a sensitivity enhancement of 40-fold for a 10 ml sample volume with a detection limit of 0.5 microg l(-1). The proposed method was successfully applied for the determination of trace copper in water, urine and biological samples.  相似文献   

15.
土壤和沉积物中多氯联苯单体测定的净化方法研究   总被引:1,自引:0,他引:1  
对浓硫酸净化、铜粉脱硫、氟罗里硅土柱、硅胶柱、石墨碳柱等净化方法在土壤和沉积物多氮联苯单体测定中的应用进行了研究.浓硫酸对多氯联苯单体的净化回收率达92.4%~109%;氟罗里硅土柱用正己烷/丙酮混合溶液淋洗,净化洗脱液体积为8 mL~10 mL时,回收率达85.7% ~ 108%;硅胶柱用正己烷淋洗,净化洗脱液体积为...  相似文献   

16.
Riparian wetlands provide critical functions for the improvement of surface water quality and storage of nutrients. Correspondingly, investigation of the adsorption characteristic and capacity of nutrients onto its sediments is benefit for utilizing and protecting the ecosystem services provided by riparian areas. The Langmuir and Freundlich isotherms and pseudo-second-order kinetic model were applied by using both linear least-squares and trial-and-error non-linear regression methods based on the batch experiments data. The results indicated that the transformations of non-linear isotherms to linear forms would affect the determination process significantly, but the non-linear regression method could prevent such errors. Non-linear Langmuir and Freundlich isotherms both fitted well with the phosphorus adsorption process (r 2?>?0.94). Moreover, the influences of temperature and ionic strength on the adsorption of phosphorus onto natural riparian wetland sediments were also studied. Higher temperatures were suitable for phosphorus uptake from aqueous solution using the present riparian wetland sediments. The adsorption capacity increased with the enhancement of ionic strength in agreement with the formation of inner-sphere complexes. The quick adsorption of phosphorus by the sediments mainly occurred within 10 min. The adsorption kinetic was well-fitted by pseudo-second-order kinetic model (r 2?>?0.99). The scanning electron microscopy (SEM) and Fourier transformation infrared (FT-IR) spectra analyses before and after phosphorus adsorption revealed the main adsorption mechanisms in the present system.  相似文献   

17.
The effects of physicochemical conditions, such as pH, water hardness, flow rates and natural organic substances on the sensitivity of Ceriodaphnia dubia to the toxic effects of copper were investigated using static bioassay cups and specially designed flow-through bioassay chambers. We found that C.dubia was very sensitive to pH changes and the total copper LC50 values of C. dubia neonates increased by 15-fold as the pH increased from pH 7 to 10. It was also observed that the LC50 values increased sharply upon increasing the water hardness value to 2.4 meq. In addition, increasing flow rates from zeroto 50 mL hr-1 also increased its sensitivity to copper, which was possibly due to hydrodynamic stress.The presence of natural organic substances (humic acid and dissolved organic matter) and suspended particles decreased thetoxic effect of copper. This significant decrease in the toxicity of copper in the presence of natural organic materialscan be explained by a reduction in the free ion concentration due to complexation. Furthermore, we observed that the kinetics of copper interactions with natural organic materials are a significant factor in the toxic effect of copper and that the acute LC50 values increased with increasing reaction time betweensolubilized copper and water-borne organics.  相似文献   

18.
N-ethyl-3-carbazolecarboxaldehyde-3-thio- semicarbazone (ECCT) as an new analytical reagent used for the development of a highly sensitive extractive spectrophotometric method for the determination of copper(II). The ECCT forms a greenish-yellow colored 1:1 (M:L) complex with copper(II) at pH 3.0, which is well extracted into n-butanol and shows maximum absorbance at 380nm. The color of the complex is stable for more than forty eight hours. The system obey Beer's law in the range 0.4–3.6 with 2.243 × 104lmol−1cm−1, 2.83 × 10-3μgcm−2 molar absorptivity and Sandell's sensitivity respectively. The regression coefficient is 0.412 with 0.99 correlation coefficient. The precision and accuracy of the method was checked by finding the relative standard deviation (0.422%). This developed method has been successfully employed for the determination of copper(II) in environmental and pharmaceutical samples. The method is evaluated by analyzing samples from the bureau of analyzed samples (BCS 233, 266, 216/1, 207 and 179) and by inter comparison of experimental values using AAS.  相似文献   

19.
Personal monitoring methods for the determination of hourly integrated concentrations of NO2 and SO2 in ambient air have been developed. Triethanolamine (TEA)-impregnated C18 Sep-Pak cartridges were used to collect NO2 and SO2 simultaneously. After sampling, NO2 and SO2 as their nitrite, nitrate, sulfite and sulfate analogues were stripped from the cartridges with a solution of 5% methanol in distilled, deionized water (DDW) and then determined by ion chromatography. Laboratory tests were conducted to evaluate the sampling rate, collection and recovery efficiencies, breakthrough volumes, absorption capacity, interference and sample stability on the cartridge during storage. NO2 and SO2 detection limits of 0.3 and 0.4 ppb respectively for 1 h samples were obtained. Recoveries for both NO2 and SO2 exceeded 85%.  相似文献   

20.
水中汞监测存在的问题与解决办法   总被引:4,自引:0,他引:4  
利用中日合作 (JICA)项目资金 ,对测定地表水中汞存在的主要问题 ,如水样的保存和处理 ,水样的消解 ,测汞的冷原子吸收法和原子荧光法等进行了研究。通过对 33个环境监测站的样品考核 ,发现测定结果与标准值相比 ,偏高的数据达 75 %以上。提出了用 1%H2 SO4 和 0 1%K2 Cr2 O7保存水样最好 ;高锰酸钾 -过硫酸钾消解法适用于消解含有机物、悬浮物和组成复杂的废水样 ,高锰酸钾 -硫酸消解法适用于消解被有机物轻度污染的废水 ,溴酸钾 -溴化钾消解法适用于消解地表水和含较少有机物的生活污水及工业废水。研究表明 :尤以硫酸 -高锰酸钾 -过硫酸钾消解体系消解地表水和废水效果良好。对冷原子吸收法和原子荧光法中影响汞测定的因素 ,如空白值高、干扰物的消除、载气种类和流量、反应瓶体积和气液比以及反应时间等提出了详尽的解决方法  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号