首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The conceptual design and evaluation of a fine particle sizing and counting instrument are introduced in this paper. A corresponding laboratory prototype was developed by coupling aerodynamic particle focusing with corona charging techniques that could detect particle sizes down to 25 nm in diameter. Comparison between the prototype and a condensation particle counter (CPC) using identical monodisperse particles showed that the measurements agreed well for the particle sizes in the range of 60–300 nm.  相似文献   

2.
3.
This paper presents an experimental investigation of the effects of impaction substrate designs and material in reducing particle bounce and reentrainment. Particle collection without coating by using combinations of different impaction substrate designs and surface materials was conducted using a personal particle sampler (PPS) developed by the University of Southern California. The PPS operates at flow rate of 4 l min-1 with a 50% cutpoint of approximately 0.9 μm in aerodynamic diameter. The laboratory results showed that the PPS collection efficiency for particles larger than 50% cutpoint is strikingly low (e.g., less than 50%) when an uncoated open cavity made of aluminum was used as an impaction substrate. The collection efficiency gradually increased when Teflon tape, Nuclepore, and glass fiber filters were used as impaction surfaces, respectively. Conical or partially enclosed cavity substrate designs increased collection efficiency of particles of 9 μm up to 80–90%. A conical cavity with glass fiber filter used as impaction surface was identified as the optimum configuration, resulting in a collection efficiency of 92% at Stokes numbers as high as 15.4 (corresponding to 9 μm in aerodynamic diameter). Particle losses were low (less than 10%) and relatively independent of particle size in any design with glass fiber filter. Losses seemed to increase slightly with particle size in all other configurations. Finally, outdoor PM1 concentrations obtained with the PPS (in its optimum configuration) and a modified micro-orifice uniform deposit impactor (MOUDI) with coated impaction stages were in excellent agreement. The mean ratio of the PPS-to-MOUDI concentration was 1.13(±0.17) with a correlation coefficient R2=0.95. Results from this investigation can be readily applied to design particle bounce-free impaction substrates without the use of coating. This is a very important feature of impactors, especially when chemical analysis of the collected particulate matter is desirable.  相似文献   

4.
With a specially designed generator, producing an aerosol of concentration, chemical composition, and size distribution similar to incinerator aerosols, a scrubber was tested in the laboratory by sampling before and after the collector. Using an Andersen Sampler as a 7 stage cascade impactor the efficiency for 7 different size classes was determined. This technique provides a rapid and simple method for evaluating the performance of a collector as a function of particle size. The multistage impaction classifies the particles according to their aerodynamic behavior. Gravimetric analysis of each stage eliminates the need for tedious counting and sizing.  相似文献   

5.
The coagulation sink and its role in new particle formation are investigated based on data obtained during the PRIDE-PRD2004 campaign at Xinken of Pearl River Delta, China. Analysis of size distributions and mode contributions of the coagulation sink show that the observed higher load of accumulation mode particles impose a significant effect on the coagulation sink and result in higher coagulation sinks at Xinken despite of the lower total particle number compared with other areas. Hence it is concluded that the higher coagulation sink may depress the occurrence frequency of new particle formation events. The strategies targeting at controlling accumulation mode particles may have influences on the frequency of new particle formation events at this area. The factors affecting the coagulation sink are evaluated. The relatively lower ambient relative humidities may weaken the coagulation sink and facilitate the occurrence of new particle formation events during noontime, while the surmise of nucleation and growth involving organic matter may imply an actually higher coagulation sink than expected. These factors have a significant influence on the ultimate fate of the newly formed nuclei and new particle formation. A comparison of event and non-event days indicates that the coagulation sink is not the only decisive factor affecting new particle formation, other factors including the precursor vapors and photochemical activity are none the less important either. Competition of coagulation sink and high source rate leads to the occurrence of new particle formation events at Xinken.  相似文献   

6.
The U.S. Environmental Protection Agency (EPA) published the Regional Haze Rule (RHR) in 1999. The RHR default goal is to reduce haze linearly from the baseline period of 2000 through 2004 to natural background in 2064. EPA-recommended method for estimating baseline and natural haze uses the Interagency Monitoring of Protected Visual Environments (IMPROVE) light extinction formula. The IMPROVE formula predicts light extinction from measured aerosol chemical concentrations and estimates of the relative humidity multiplier. On average, the IMPROVE formula overpredicts 6156 nephelometer days (24-hr average measured particle light scattering, bsp) of data by 25%. A new IMPROVED method that reconstructs light extinction using a concentration power law model overpredicts these nephelometer days of data by just 2%. Ignoring the 20% lowest light scattering days, this new IMPROVED formula has a 3% underprediction bias over the 4925 highest nephelometer days with light scattering > or =8 inverse megameters. For comparison, the IMPROVE formula has a 12% overprediction bias for the same days. The IMPROVE formula overprediction averages 77%, 27%, 17%, 9%, and -5% broken down by quintile from lowest to highest nephelometer measured light scattering days. The new IMPROVED formula average overprediction is 21%, -5%, -5%, -2%, and 0%. So, agreement between measured and predicted light scattering improves by modifying the current IMPROVE light extinction formula.  相似文献   

7.
An environmentally friendly and inexpensive substitute to the widely used poly(vinyl alcohol) (PVA) has been developed from soy proteins for textile warp sizing. Textile processing is the major source of industrial water pollution across the world, and sizing and desizing operations account for nearly 30 % of the water consumed in a textile plant. PVA is one of the most common sizing agents used for synthetic fibers and their blends due to PVA’s easy water solubility and ability to provide desired sizing performance. However, PVA does not degrade and is a major contributor to pollution in textile effluent treatment plants. Although considerable efforts have been made to replace PVA with biodegradable sizing materials, the performance properties provided by PVA on synthetic fibers and their blends have been unmatched so far. Soy proteins are inexpensive, biodegradable, and have been widely studied for potential use in food packaging, as resins and adhesives. In this research, the potential of using soy proteins as textile sizing agents to replace PVA was studied. Polyester and polyester/cotton rovings, yarns, and fabrics sized with soy protein showed a considerably better improvement in strength and abrasion resistance compared to commercially available PVA-based size. Soy protein size had a 5-day biochemical oxygen demand /chemical oxygen demand ratio of 0.57 compared to 0.01 for PVA indicating that soy protein sizes were easily biodegradable in activated sludge. The total and ammonia nitrogen released from the proteins also did not adversely impact the biodegradability. Good sizing performance and easy biodegradability demonstrate that soy protein-based sizes have potential to replace PVA-based sizes leading to substantial benefits to the textile industry and the environment.  相似文献   

8.
CuO nanoparticles (CuO-NP) were synthesized in a hydrogen diffusion flame. Particle size and morphology were characterized using scanning mobility particle sizing, Brunauer-Emmett-Teller analysis, dynamic light scattering, and transmission electron microscopy. The solubility of CuO-NP varied with both pH and presence of other ions. CuO-NP and comparable doses of soluble Cu were applied to duckweeds, Landoltia punctata. Growth was inhibited 50% by either 0.6 mg L−1 soluble copper or by 1.0 mg L−1 CuO-NP that released only 0.16 mg L−1 soluble Cu into growth medium. A significant decrease of chlorophyll was observed in plants stressed by 1.0 mg L−1 CuO-NP, but not in the comparable 0.2 mg L−1 soluble Cu treatment. The Cu content of fronds exposed to CuO-NP is four times higher than in fronds exposed to an equivalent dose of soluble copper, and this is enough to explain the inhibitory effects on growth and chlorophyll content.  相似文献   

9.
以尿素和钛酸丁酯为原料,通过溶胶-凝胶法低温下制备了高可见光催化活性的氮掺杂TiO2(NDT)光催化剂,采用XRD、TEM、BET和UV-Vis DRS等测试手段对其进行了表征,并在自制光催化反应器中降解甲基橙评价了样品的光催化活性。结果表明,当氮与钛的摩尔比为0.5∶1时,350℃焙烧的样品(NDT350)具有最佳的可见光光谱吸收和光催化活性,该催化剂为锐钛矿晶相,平均粒径为21 nm,比表面积为89.13 m2/g。可见光辐照下,NDT350降解甲基橙的表观反应速率常数为1.381×10-2min-1,是商业P25催化剂的16.85倍。NDT350优良的可见光催化活性与其大的比表面积和强烈的可见光光谱吸收有关。  相似文献   

10.
The chemical and optical properties of particle emissions from onroad vehicles were investigated at the Allegheny Tunnel on the Pennsylvania Turnpike during July 1981. The optical results are in agreement with earlier data: (1) in terms of light extinction per km driven, diesel particle emissions are at least an order of magnitude more important than particle emissions from spark-ignition vehicles; (2) for diesel particle emissions, light absorption is about twice as efficient as light scattering. Chemical analyses showed that: (1) 24% of the vehicle aerosol was extractable material, (2) 75% of the total mass was carbon, (3) 55% of the total mass was unextractable (elemental) carbon, and (4) the stoichiometry of the extractable fraction of the diesel particle emissions was CnHt.7nN0.05n , i.e., the extractable material was composed predominantly of alkanes. The results of the chemical analyses allow the calculation of the massspecific light absorption coefficient for the elemental carbon component of the diesel particle emissions, i.e., 10.9 ± 1.8 m2/g (500 nm).  相似文献   

11.
Abstract

Gas-phase dispersion in granular biofilter materials with a wide range of particle sizes was investigated using atmospheric air and nitrogen as tracer gases. Two types of materials were used: (1) light extended clay aggregates (LECA), consisting of highly porous particles, and (2) gravel, consisting of solid particles. LECA is a commercial material that is used for insulation, as a soil conditioner, and as a carrier material in biofilters for air cleaning. These two materials were selected to have approximately the same particle shape. Column gas transport experiments were conducted for both materials using different mean particle diameters, different particle size ranges, and different gas flow velocities. Measured breakthrough curves were modeled using the advection-dispersion equation modified for mass transfer between mobile and immobile gas phases. The results showed that gas dispersivity increased with increasing mean particle diameter for LECA but was independent of mean particle diameter for gravel. Gas dispersivity also increased with increasing particle size range for both media. Dispersivities in LECA were generally higher than for gravel. The mobile gas content in both materials increased with increasing gas flow velocity but it did not show any strong dependency on mean particle diameter or particle size range. The relative fraction of mobile gas compared with total porosity was highest for gravel and lowest for LECA likely because of its high internal porosity.  相似文献   

12.
The occurrence of particle associated PAH and other mutagenic PAC was determined in 1996 in the street air of Copenhagen. In addition, particle extracts were tested for mutagenicity. The measurements were compared with previous measurements in 1992/1993. The levels had decreased in this period. The decrease was caused by an implementation of light diesel fuels for buses and the exchange of older petrol-driven passenger cars with catalystequipped new ones. About 65% of the reduction was caused by the application of the light diesel fuels. Under special conditions, chemical processes in the atmosphere produced many more mutagens than the direct emissions. The concentrations of S-PAC and N-PAC were 10 times lower than those of PAH, while the levels of oxy-PAH were in the same order of magnitude as those of PAH. Benzanthrone, an oxy-PAH, is proposed to be formed in the atmosphere in addition to direct emissions. Benzo(a)pyrene, often applied as an air quality criteria indicator, was photochemically degraded in the atmosphere. A strong increase in the mutagenic activities was observed to coincide with a depletion of benzo(a)pyrene.  相似文献   

13.
14.
Recent improvements in integrated and continuous PM2.5 mass and chemical measurements from the Supersite program and related studies in the past decade are summarized. Analytical capabilities of the measurement methods, including accuracy, precision, interferences, minimum detectable levels, comparability, and data completeness are documented. Upstream denuders followed by filter packs in integrated samplers allow an estimation of sampling artifacts. Efforts are needed to: (1) address positive and negative artifacts for organic carbon (OC), and (2) develop carbon standards to better separate organic versus elemental carbon (EC) under different temperature settings and analysis atmospheres. Advances in thermal desorption followed by gas chromatography/ mass spectrometry (GC/MS) provide organic speciation of approximately 130 nonpolar compounds (e.g., n-alkanes, alkenes, hopanes, steranes, and polycyclic aromatic hydrocarbons [PAHs]) using small portions of filters from existing integrated samples. Speciation of water-soluble OC (WSOC) using ion chromatography (IC)-based instruments can replace labor-intensive solvent extraction for many compounds used as source markers. Thermal gas-based continuous nitrate and sulfate measurements underestimate filter ions by 10-50% and require calibration against on-site filter-based measurements. IC-based instruments provide multiple ions and report comparable (+/-10%) results to filter-based measurements. Maintaining a greater than 80% data capture rate in continuous instruments is labor intensive and requires experienced operators. Several instruments quantify black carbon (BC) by optical or photoacoustic methods, or EC by thermal methods. A few instruments provide real-time OC, EC, and organic speciation. BC and EC concentrations from continuous instruments are highly correlated but the concentrations differ by a factor of two or more. Site- and season-specific mass absorption efficiencies are needed to convert light absorption to BC. Particle mass spectrometers, although semiquantitative, provide much information on particle size and composition related to formation, growth, and characteristics over short averaging times. Efforts are made to quantify mass by collocating with other particle sizing instruments. Common parameters should be identified and consistent approaches are needed to establish comparability among measurements.  相似文献   

15.
Bae PH  Hwang YJ  Jo HJ  Kim HJ  Lee Y  Park YK  Kim JG  Jung J 《Chemosphere》2006,63(6):1041-1047
Plasma treatment was evaluated as an alternative clean desizing technology in this work. As indicated by weight loss, O2 plasma treatment efficiently removed sizing agents such as polyvintyl alcohol (PVA), polyacrylic acid esters and their mixture (MIX) on polyethylene terephthalate (PET) fabrics. SEM pictures of the plasma treated samples directly proved the disappearance of the sizing agents. XPS analysis showed apparent changes in chemical composition and functional groups of the PET surface after O2 plasma treatment. Carbon content decreased due to the removal of sizing agents while oxygen content increased. O2 plasma treatment also increased hydrophilic functional groups of sizing agents, which is confirmed by C1s and O1s deconvolution analyses. After O2 plasma treatment, the PET fabric was subjected to conventional desizing process at different temperatures. Except for the PET fabric sized with PVA, plasma-treated fabrics showed more efficient desizing results when compared with untreated fabrics. Furthermore, the desizing effluent from the treated fabric gave lower TOC, COD and BOD values.  相似文献   

16.
A particulate sampling train has been constructed which satisfies the conflicting requirements of isokinetic sample extraction and constant flow rate through an inertial sizing device. Its design allows a variable fraction of the filtered emission gas to be added to the sample upstream of the inertial sizing device in order to maintain a preselected flow rate through this device while the gas flow rate into the sampling nozzle is adjusted to remain isokinetic with the local duct velocity. The prototype emission gas recycle (EGR) train was constructed by relatively simple modifications of a commercially available Method 5 sampling system, and much of the sampling technique is identical with Method 5 protocol. The train was tested by comparison of parallel runs in the EPA/SRI wind tunnel using redispersed fly ash. In one series of runs performed without inertial sizing devices, the EGR train and a colocated non- EGR train sampled 3-point traverses. The differences of the average mass concentrations measured by the two trains was 3.3 percent, with a standard deviation of 4.7 percent. In the next series of runs, identical cyclone inertial sizing devices were added to each train. The difference of the average mass concentration for these runs was 1.2 percent, with a standard deviation of 5.7 percent.  相似文献   

17.
Particulate mass concentration measurements have been made on environmental tobacco smoke (ETS) for the purpose of assessing the relative accuracy of several measurement procedures. ETS over a range of concentrations was generated in an environmental chamber by three methods. Mass concentration was measured by a gravimetric/spectrophotometric collection procedure, piezoelectric particle mass monitors, two nephelometry-based mass monitors, and a particle counting and sizing system. Two-hour average mass concentrations were determined by each method for concentrations ranging from very low levels up to those achieved by smoking one entire cigarette in the chamber. Statistical comparisons were made among procedures employing the gravimetric filter measurement as the basis for comparison. One nephelometry-based procedure gave significantly higher and the other significantly lower values than the filter determination. In one case, a correction for the difference between the particle mass density of the calibrating aerosol and that of ETS brought the nephelometry-based procedure into reasonable agreement with the filter measurement, while for the other, the correction did not resolve the discrepancy between methods. Statistically significant differences between the responses of two supposedly identical piezoelectric mass monitors were found, as was some slight dependence of the nephelometry- based procedures on method of ETS generation. In summary, the results indicate that significant errors can be expected if the instruments studied are used “off the shelf,” even for ETS generated under controlled laboratory conditions. Caution should be employed in field measurements where numerous sources and types of particulate matter can be encountered.  相似文献   

18.
Abstract

Field experiments were conducted in corn plots during 1988 that were artificially Infested with stalkborers, Papianema nebris (Guenee'). Two atomizers, a flatfan and a flood nozzle chosen for different droplet size distributions were used to apply two insecticides, chlorpyrifos and cyfluthrin at two application rates. Nozzles, insecticides, rates, and associated interactions were evaluated for control of stalkborer in the field. Laboratory studies involved application of insecticides to soil and glass via a spray track for bioassay at field application rates. Image analysis of percent area travelled on water sensitive paper by stalkborers was compared to droplet percent area covered to obtain percent area contacted per insect. Droplet size distributions for each nozzle were obtained using an Aerometrics particle sizing instrument. Significant differences in stalkborer control were attributed to percent area covered by smaller droplets measured by image analysis.  相似文献   

19.
Understanding of aerosol dispersion characteristics has many scientific and engineering applications. It is recognized that Eulerian or Lagrangian approach has its own merits and limitations. A new Eulerian model has been developed and it adopts a simplified drift–flux methodology in which external forces can be incorporated straightforwardly. A new near-wall treatment is applied to take into account the anisotropic turbulence for the modified Lagrangian model. In the present work, we present and compare both Eulerian and Lagrangian models to simulate particle dispersion in a small chamber. Results reveal that the standard kε Lagrangian model over-predicts particle deposition compared to the present turbulence-corrected Lagrangian approach. Prediction by the Eulerian model agrees well with the modified Lagrangian model.  相似文献   

20.
Detection of combustion formed nanoparticles   总被引:1,自引:0,他引:1  
UV–visible extinction and scattering and two extra situ sampling techniques: atomic force microscopy (AFM) and differential mobility analysis (DMA) are used to follow the evolution of the particles formed in flames. These particle sizing techniques were chosen because of their sensitivity to detect inception particles, which have diameters, d<5 nm, too small to be observed with typical particle measurement instrumentation. The size of the particles determined by AFM and DMA compares well with the size determined by in situ optical measurements, indicating that the interpretation of the UV–visible optical signal is quite good, and strongly showing the presence of d=2–4 nm particles. UV–visible extinction measurements are also used to determine the concentration of d=2–4 nm particles at the exhausts of practical combustion systems. A numerical model, able to reproduce the experimentally observed low coagulation rate of nanoparticles with respect to soot particles, is used to investigate the operating conditions in the combustion chamber and exhaust system for which 2–4 nm particles survive the exhaust or grow to larger sizes. Combustion generated nanoparticles are suspected to affect human and environmental health because of their affinity for water, small size, low rate of coagulation, and large surface area/weight ratio. The ability to isolate nanoparticles from soot particles in hydrosols collected from combustion may be useful for future analysis by a variety of techniques and toxicological assays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号