首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 140 毫秒
1.
MUCT-MBR工艺反硝化除磷脱氮研究   总被引:3,自引:2,他引:1  
自行设计的双反应器MUCT-MBR简化了MUCT工艺,将反应池由5个简化到2个,减小了工艺占地面积,并且采用膜过滤取代二沉池出水,操作简单,出水安全可靠.针对MUCT-MBR工艺脱氮除磷性能,尤其是反硝化除磷功能进行研究.结果表明,当进水C/N/P比在33.3/5/1~25/5.5/1范围内,整个实验过程中COD、 TN和TP平均去除率分别达到89.3%、 75.4%、 79.2%;且膜出水不受污泥沉降性的影响.缺氧段的反硝化吸磷是MUCT-MBR工艺除磷的关键,系统运行至第58 d,系统中反硝化除磷菌(DPAOs)所占比例达84.2%,反硝化除磷占系统总磷去除的67.07%.  相似文献   

2.
SRT对UCT-MBR反硝化除磷性能与膜污染行为的影响   总被引:2,自引:0,他引:2  
采用脱氮除磷膜生物反应器(UCT-MBR)工艺处理冀南地区城市污水,考察了SRT对UCT-MBR工艺反硝化除磷性能与膜污染行为的影响.结果表明:较短(15d)与较长(40d)SRT均不利于反硝化聚磷菌(DPAOs)的富集;SRT控制在25d时系统的反硝化除磷性能得到最大程度强化,反硝化聚磷菌(DPAOs)占聚磷菌(PAOs)的数量比例及缺氧除磷率达到最大值,分别稳定在50.9%和88%,并且此时系统总磷(TP)、总氮(TN)去除率也达到最大值91.7%、73.6%,出水浓度分别稳定在0.48, 13.3mg/L左右;SRT对系统COD、氨氮(NH4+-N)的去除效能影响不大,COD、NH4+-N平均去除率分别为89.8%、99.7%,出水浓度分别稳定在30.8, 0.15mg/L;随着SRT的延长,膜池混合液固体(MLSS)浓度升高,分子量大于100kDa、小于1kDa的溶解性微生物代谢产物(SMP)浓度和胞外聚合物(EPS)比污泥浓度升高及污泥粒径(PSD)减小,是导致膜池污泥可滤性变差的主要原因,从而致使系统膜渗透性加速降低、持续运行周期缩短,而红外光谱(FT-IR)分析表明SRT对膜污染物质的组成无显著影响,光谱折射率与SMP、EPS含量呈现一致性.  相似文献   

3.
污泥龄对A/A/O工艺反硝化除磷的影响   总被引:12,自引:0,他引:12  
徐伟锋  陈银广  张芳  顾国维 《环境科学》2007,28(8):1693-1696
以实际生活污水培养驯化污泥的小试规模A/A/O工艺为研究对象,进行了污泥龄(SRT)为8、10、12和15 d时对反硝化除磷的影响研究.结果表明,随着污泥龄的延长,反硝化除磷对系统除磷所起的作用越大,反硝化聚磷菌缺氧利用单位PHAs的反硝化数量和吸磷量也迅速增加,聚磷菌好氧利用单位PHAs的吸磷量并没有受到影响,以SRT为12 d时反硝化除磷和系统脱氮除磷效果为最好.结果还表明,去除单位氮所需COD数量随污泥龄的延长呈减少趋势,而去除单位磷所需COD数量呈增大趋势.对于我国典型的城市污水而言,SRT为12 d和15 d时去除单位氮和磷所需的外碳源数量较8 d时要低,从而使反硝化除磷作用可真正地达到节省碳源和能源的目的.  相似文献   

4.
选用4组同规格SBR反应器,在A/O/A模式下以水解酸化液为进水,调整厌/缺氧时间分别为50min/170min、90min/130min、130min/90min、180min/40min,探讨颗粒污泥在不同厌/缺氧时间下脱氮除磷特性.结果表明,厌氧时间从50min延长至90min时,污泥内碳源储存量和释磷量增加,同步硝化反硝化(SND)效率提高至62.65%,TN、TP去除率分别从81.1%、 82.2%上升92.9%、98.5%.当厌氧时间从90min升至180min时,释磷量反而下降,厌氧内源性条件刺激胞外聚合物(EPS)增加造成聚羟基烷酸(PHA)合成下降,TP去除率降至88.1%;同时缺氧时间从130min降至40min,系统残留的NOX-较多,造成TN去除率降低至84%.机理分析表明系统中TN在好氧段由反硝化聚磷菌(DPAOs)和反硝化聚糖菌(DGAOs)利用PHA以SND方式消耗,并在缺氧段由DGAOs内源反硝化进一步去除,TP由PAOs和DPAOs去除,由批次实验估算得DPAOs占比在R2中最高,达41%,4组反应器运行期间颗粒均未发生解体,以水解酸化液为基质培养的颗粒结构完整、稳定性强.结果表明,厌/缺氧时间的适当延长有利于加强内碳源的贮存与转化,强化厌氧释磷、SND和后置内源反硝化效果,实现同步硝化内源反硝化和除磷高效稳定运行.  相似文献   

5.
利用城市实际污水考察了ρ(MLSS)在2 400、3 350、4 300和5 250 mg/L 4种工况下SBR反应器(厌氧/好氧/缺氧/再好氧/沉淀/排水/预缺氧运行模式)的脱氮除磷效果,并分析了反应器单个周期内有机物、氮和磷的转化过程及污泥产量. 结果表明:ρ(MLSS)由2 400 mg/L升至5 250 mg/L时,系统TN去除率由52.5%升至66.6%;后续缺氧及预缺氧工序的脱氮比例(该工序TN去除量占系统TN总去除量的比例)由12.7%增至23.1%;ρ(MLSS)为4 300 mg/L时系统TP去除率(75.6%)达到最大. 后续缺氧及预缺氧工序中,ρ(MLSS)与内源反硝化速率呈正相关(R2=0.703 7);提高ρ(MLSS)可使PAOs(聚磷菌)在下一个周期内获得更多的碳源,使厌氧释磷量由1.62 mg/L升至9.10 mg/L,但PAOs吸磷动力会减弱,对除磷不利. 在后置反硝化、污泥衰减、能量解偶联等减量机制共同作用下,ρ(MLSS)为4 300 mg/L时系统污泥减量可提高24.4%. 从脱氮除磷及污泥减量效果综合考虑,ρ(MLSS)是双重后置反硝化工艺重要的控制参数,在该研究条件下控制在4 300 mg/L最优.   相似文献   

6.
采用改良A2/O-BAF双污泥系统处理低C/N比生活污水,为提高碳源利用率,研究了两段进水(预缺氧段和缺氧段)对反硝化除磷脱氮的影响,同时根据COD的物料衡算公式,分析评价了不同进水比下,碳源的利用情况.结果表明当分段进水比为7:3时,平均进水COD、NH4+-N、TN、TP浓度分别为174.99、58.19、59.10、5.15 mg·L-1,出水COD、NH4+-N、TN、TP浓度分别为29.48、4.07、14.10、0.44 mg·L-1,去除率分别为82.12%、92.76%、75.45%、91.20%;系统中反硝化聚磷菌占聚磷菌的比例(DPAOs/PAOs)为98.81%,此时系统反硝化除磷脱氮最佳,同时碳源的有效利用率达85.77%,平衡百分比为92.33%.通过优化分段进水,碳源被有效利用,提高了同步脱氮除磷效率,为改良A2/O-BAF双污泥系统处理低C/N比污水提供理论依据.  相似文献   

7.
为探究自行设计的A~3/O-MBR工艺脱氮除磷性能,以模拟生活污水为处理对象,重点研究了在内循环回流比(γ)为100%,硝化液回流比(α)分别为100%、200%、300%条件下系统反硝化除磷特性。结果表明:缺氧II区是工艺反硝化除磷的关键,系统具有优良的同步脱氮除磷效果,ρ(COD)出水均低于50 mg/L。当回流比为200%时,系统对TN、TP去除效果最好,平均去除率分别为75.46%和88.94%,出水平均ρ(TN)、ρ(TP)分别为14.97 mg/L和0.48 mg/L。通过静态释/吸磷试验测定不同硝化液回流比条件下反硝化聚磷菌占总聚磷菌的比例及污泥含磷量,当回流比为200%时,反硝化聚磷菌所占比例最高达95.47%,该回流比条件下缺氧II区污泥含磷量最高为23.07 mg/L,最大吸磷量为0.2136 g/d。  相似文献   

8.
以实际低C/N生活污水为研究对象,依次分别采用A2O工艺和A2O+BCO(生物接触氧化)工艺考察系统的脱氮除磷性能.试验在进水负荷和运行参数基本维持不变的情况下运行134d.结果表明,相对于A2O系统,A2O+BCO系统由于采用双污泥工艺,硝化菌和聚磷菌(PAOs)污泥龄分离,同时反硝化除磷"一碳两用",碳源利用率更高,TN和TP去除率分别提高了18%和28%.其次FISH试验表明,在稳定运行的A2O+BCO工艺中,PAOs比例为22%,远远超过A2O中7%的比例,从微生物角度证明了脱氮除磷效果好的原因.  相似文献   

9.
以生活污水作为处理对象,研究了双污泥短程硝化-反硝化除磷工艺A2/N-SBR长期反硝化除磷脱氮的性能,考察了典型周期系统运行效果,并探讨短程反硝化聚磷菌代谢机制。结果表明:A2/N-SBR工艺长期稳定运行有机物去除及脱氮除磷性能良好;典型周期内NO-2-N和TP出水浓度分别为0.53 mg/L和1.14 mg/L,TP去除率达88.8%;厌氧释磷阶段COD和胞内糖原浓度分别减少107.21 mg/L和76.81 mg/L,内碳源PHB含量增加150.88 mg/L,厌氧末期TP浓度是初始TP浓度的2.6倍,缺氧吸磷阶段TP和NO-2-N去除率分别为94%和96%。A2/N-SBR工艺脱氮除磷效果显著且稳定性强,短程反硝化聚磷菌吸磷反应的电子供体PHB的合成来自外碳源和糖原。  相似文献   

10.
温度对生物强化除磷工艺反硝化除磷效果的影响   总被引:8,自引:1,他引:7  
以处理城市污水的中试规模生物强化除磷A2/O活性污泥工艺系统为研究对象,考察了温度对系统COD去除和脱氮除磷效果的影响,特别是温度对活性污泥反硝化除磷性能的影响.结果表明,当温度从(30.9±0.8)℃降低到(9.1±0.6)℃时,A2/O系统的脱氮除磷效果显著下降,系统对TN和TP的污泥去除负荷明显下降.通过污泥反硝化除磷活性实验发现,随着温度的降低,系统中活性污泥的最大厌氧释磷速率、最大好氧吸磷速率和最大缺氧吸磷速率都降低.活性污泥中反硝化除磷菌(DPB)占聚磷菌(PAOs)总量的比例随温度降低稍有下降,但平均值仍维持在47.5%左右.用阿伦尼乌斯公式对实验结果进行拟合,得到系统中活性污泥聚磷菌厌氧释磷反应活化能Ea1为148.0 kJ· mol-1,聚磷菌好氧吸磷反应活化能Ea2为228.8 kJ·mol-1,发生在缺氧条件下反硝化除磷菌的吸磷反应活化能Ea3为315.8 kJ·mol-1.对不同温度下污泥絮体粒径分析结果表明,随温度降低,粒径分布更加集中,系统中活性污泥絮体颗粒平均粒径减小,不利于污泥絮体内部反硝化除磷缺氧微环境的形成.  相似文献   

11.
A bench-scale anaerobic/anoxic/aerobic process-biological aerated filter (A^2/O-BAF) combined system was carded out to treat wastewater with lower C/N and C/P ratios. The A^2/O process was operated in a short aerobic sludge retention time (SRT) for organic pollutants and phosphorus removal, and denitrification. The subsequent BAF process was mainly used for nitrification. The BAF effluent was partially returned to anoxic zone of the A^2/O process to provide electron acceptors for denitrification and anoxic P uptake. This unique system formed an environment for reproducing the denitdfying phosphate-accumulating organisms (DPAOs). The ratio of DPAOs to phosphorus accumulating organisms (PAOs) could be maintained at 28% by optimizing the organic loads in the anaerobic zone and the nitrate loads into the anoxic zone in the A^2/O process. The aerobic phosphorus over-uptake and discharge of excess activated sludge was the main mechanism of phosphorus removal in the combined system. The aerobic SRT of the A^2/O process should meet the demands for the development of aerobic PAOs and the restraint on the nitrifiers growth, and the contact time in the aerobic zone of the A^2/O process should be longer than 30 min, which ensured efficient phosphorus removal in the combined system. The adequate BAF effluent return rates should be controlled with 1--4 mg/L nitrate nitrogen in the anoxic zone effluent of A^2/O process to achieve the optimal nitrogen and phosphorus removal efficiencies.  相似文献   

12.
温度及反硝化聚磷对SBMBBR脱氮除磷的影响   总被引:7,自引:2,他引:5  
吴广华  张耀斌  全燮  赵雅芝 《环境科学》2007,28(11):2484-2487
实验在维持进水COD、PO3-4-P和NH+4-N浓度分别为450 mg/L 、10 mg/L和40 mg/L左右的条件下,考察了较低温度(14℃±1℃)和较高温度(24℃±1℃)对SBMBBR(序批式移动床生物膜反应器)除磷脱氮效果的影响.结果表明,14℃±1℃和24℃±1℃下,PAOs(聚磷菌)的释磷量分别为54 .7 mg/L、19 .7 mg/L;除磷率分别为98 .3%、83 .4%;脱氮率分别为87 .8%、98 .4%.较低温度有利于PAOs的富集,但不利于硝化的进行;较高温度有利于硝化反硝化的进行,但PAOs不再是污泥系统的优势菌种.同时在经过较长时间(3个月)厌氧/好氧运行的污泥系统中进行了厌氧/缺氧反硝化除磷实验,该系统内反硝化聚磷除磷效果较好,反硝化吸磷占总吸磷量的80%左右.  相似文献   

13.
为了解同步硝化内源反硝化除磷(SNEDPR)系统处理低C/N(<3)污水的脱氮除磷特性,采用厌氧/低氧(溶解氧0.5~1.0mg/L)运行的SBR反应器,以低碳城市污水为处理对象,考察了C/N对SNEDPR启动、脱氮除磷性能优化与菌群结构变化的影响.结果表明:进水C/N由4.3提高至5.15时,系统脱氮除磷性能均逐渐增强,系统总氮(TN)和PO43--P去除率最高达89.3%和90.6%;降低进水C/N <3后,系统脱氮、除磷性能均呈现先降低后逐渐升高的趋势,但低C/N对PAOs(聚磷菌)除磷性能的影响高于其对反硝化聚糖菌(DGAOs)内源反硝化脱氮性能的影响,表现为TN和PO43--P去除率分别先降低至21.4%和3.4%后逐渐升高至92.9%和94.1%.系统稳定运行阶段,单位COD平均释磷量和SNED率达437.1mgP/gCOD和89.1%,出水NH4+-N、NOx--N和PO43--P浓度平均为0,4.4,0.2mg/L.经136d的运行,系统内PAOs,GAOs,AOB(氨氧化菌)和NOB(亚硝酸盐氧化菌)分别占全菌的(16±3)%,(8±3)%,(7±3)%和(3±1)%,其保证了系统除磷、硝化和反硝化脱氮性能.此外,系统好氧段存在同步短程硝化内源反硝化,是实现低C/N(<3)污水高效脱氮除磷的原因.  相似文献   

14.
进水C/N对富集聚磷菌的SNDPR系统脱氮除磷的影响   总被引:1,自引:0,他引:1  
为了解富集聚磷菌(PAOs)的同步硝化反硝化除磷(SNDPR)系统的脱氮除磷特性,采用延时厌氧(180min)/低氧(溶解氧0.5~1.0mg/L)运行的SBR反应器,以实际生活污水为处理对象, 通过投加固态乙酸钠调节进水C/N值(约为11,8,4,3),考察其对系统脱氮除磷特性及同步硝化反硝化(SND)脱氮率的影响.结果表明:C/N对系统的除磷性能没有影响,出水PO43--P浓度均稳定在0.3mg/L左右,这是由于系统内聚磷菌(PAOs)含量高,且在低氧段可同时发生好氧吸磷与反硝化吸磷.随着C/N的增大,出水NH4+-N浓度升高,C/N下降时,出水NO3--N浓度升高.此外,随着C/N的减小,厌氧段反硝化所消耗的COD占进水COD的比例增大,SND可利用的内碳源-PHAs储存量减少,但PHV的利用率增加;当C/N为4~8时,SND现象最明显,SND脱氮率达50.8%,而其它C/N条件下,SND脱氮率都有相应程度的减弱.C/N为8时,系统出水综合指标最好,TN去除率高达80.8%.  相似文献   

15.
内循环对A2/O-曝气生物滤池工艺脱氮除磷特性影响   总被引:8,自引:6,他引:2  
在原水温度为15℃和C/N为4.9的条件下,以实际生活污水为研究对象,重点考察了内回流比为100%、200%、300%和400%时小试规模A2/O-曝气生物滤池工艺脱氮除磷特性.结果表明,该生化系统可实现有机物、氮和磷的同步深度去除.在总HRT为8.0 h、SRT为15 d、污泥回流比为100%和MLSS为4.0 g·...  相似文献   

16.
为促进反硝化除磷与厌氧氨氧化工艺的耦合,实现污水氮、磷的同步高效去除,构建序批式反应器(Sequencing batch reactor,SBR),优化了反硝化除磷工艺实现亚硝酸盐积累的工艺参数.SBR在厌氧-缺氧-微好氧运行条件下,缺氧段投加模拟硝酸盐工业废水逐步实现了反硝化除磷过程的亚硝酸盐积累.结果表明,经过142d的培养驯化,在进水C/P比为55时,缺氧段引入NO3--N浓度为23mg/L时,亚硝酸盐积累率为51.01%,NO3--N→NO2--N转化率为40.22%,硝酸盐去除率为72.14%,PO43--P去除率最高达88.17%.出水COD浓度低于25mg/L,COD去除率维持在90%以上.微生物群落结构分析表明,拟杆菌门(Bacteroidetes)、变形菌门(Proteobacteria)、绿弯菌门(Chloroflexi)、酸杆菌门(Acidobacteria)为系统内优势菌门.通过参数优化实现了聚磷菌的驯化,Candidatus Accumulibacter为代表的反硝化聚磷菌丰度增加(累积丰度由1.49%增加到5.08%),以Candidatus Competibacter为代表的反硝化聚糖菌丰度增加更为明显(累积丰度由1.02%增加到15.49%),聚磷菌与聚糖菌的共同作用有利于实现除磷过程的亚硝酸盐累积.  相似文献   

17.
A~2/O-曝气生物滤池工艺处理低C/N比生活污水脱氮除磷   总被引:8,自引:0,他引:8  
以低C/N比实际生活污水为研究对象,重点考查了A2/O-曝气生物滤池生化系统的脱氮除磷特性.同时,考虑到A2/O工艺的主要功能是除磷及反硝化,而曝气生物滤池则以硝化为目的.因此,通过缩短A2/O的泥龄,可将硝化过程从A2/O中分离出去,让曝气生物滤池完成硝化,实现硝化菌和聚磷菌的分离,并解决了硝化菌和聚磷菌泥龄之间的矛盾.试验结果表明,该生化系统可实现有机物、氮和磷的同步去除.在平均C/N比为4.2,内回流比R为250%的条件下,平均进水COD、TN、TP分别为239.9、57.3和5.1mg·L-1,平均最终出水COD、TN、TP分别为34.1、13.3和0.1mg·L-1,去除率分别为85.8%、76.9%和98.3%.曝气生物滤池对氨氮几乎保持了100%的去除率.序批试验表明,反硝化聚磷菌占聚磷菌的比例为40.5%.  相似文献   

18.
COD/TP比及NO_2~--N/TP对短程反硝化聚磷的影响   总被引:1,自引:0,他引:1  
污水中COD/TP比和NO2--N/TP比对A/A/OSBR反硝化聚磷工艺运行有重要的影响。实验结果表明:随着COD/TP比值的增加,厌氧释磷增加、厌氧释磷速率提高。但当COD/TP比值为28.5时,过剩的碳源进入缺氧段,反硝化菌利用外碳源消耗,抑制了缺氧吸磷过程;当COD/TP比值为21时,合成的PHB不足,缺氧吸磷效率下降,而且长期在较低COD/TP比条件下运行,激发了聚糖菌与聚磷菌的竞争,聚磷菌处于竞争的劣势,反硝化聚磷能力最终消失;当COD/PO43--P为25时,短程反硝化聚磷效果最佳。NO2--N/TP比与COD/TP的比值相关联,在COD/TP=25的条件下,合适的NO2--N/TP比为3。当NO2--N/PO43--P为5时,SBR上一周期剩余的NO2-会影响厌氧释磷过程。当NO2--N/TP为1.8时,NO2-不足,会使反硝化聚磷过程不完全。  相似文献   

19.
好氧颗粒污泥处理制糖工业废水厌氧出水的除磷特性研究   总被引:2,自引:1,他引:1  
制糖工业废水经厌氧生物处理后,COD大幅下降,但是出水中N、P含量仍然较高,严重破坏水体生态平衡.利用好氧颗粒污泥对制糖工业废水的厌氧出水进行脱氮除磷处理,讨论了其除磷过程.经复合底物(乙酸盐、丙酸盐、丁酸盐)培养的好氧颗粒污泥直径1.7 mm,SVI为38.43 mL.g-1,TP去除率达90.9%,出水磷含量仅为1.3 mg.L-1,单位COD释磷率为0.571,厌氧条件下磷的释放速率达到5.73 mg.(g.h)-1,好氧颗粒污泥表现出较好的沉淀性能和较高的除磷活性.由于底物中丙酸盐、丁酸盐含量增加,使得聚磷菌在反硝化过程中NO3--N的利用率增加,即消耗单位质量的NO3--N可以吸收更多的磷.好氧颗粒污泥及其胞外聚合物中P元素的含量与其中Mg、Ca、Fe元素的含量表现出很高的相关性,胞外聚合物对P的吸附使得体系除磷能力进一步增强.通过对污泥反硝化除磷的研究发现,反硝化聚磷菌占总聚磷菌的61.9%,其吸磷量与消耗硝酸盐的比值[m(P)/m(NO3--N)]为1.14.  相似文献   