首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Photocatalytic degradation of organic wastes with nanosized titanium dioxide particles has been studied for a long time in order to offer an appropriate method for wastewater treatment, but its practical application is greatly limited by the slow process. In this work, an electrochemically assisted TiO2 photocatalytic system was set-up by combining a TiO2 photocatalytic cell with a three-electrode potentiostatic unit. The composite system revealed high photocatalytic activity towards organic wastes mineralization. After continuous treatment for 0.5 h, the maximum absorption of rhodamine 6G (R-6G) was reduced by more than 90%; chemical oxygen demand (COD) and biochemical oxygen demand (BOD5) of textile dye wastewater (TDW) were decreased by 93.9 and 88.7%, respectively. The biodegradability of TDW was also improved because the COD/BOD5 ratio decreased from 2.1 to 1.2. All these results indicated that the composite system could be used for effective organic wastes mineralization or as a feasible detoxification and color removal pretreatment stage for biological post treatment.  相似文献   

2.
萃取预处理苯胺基乙腈生产废水试验研究   总被引:2,自引:0,他引:2  
在苯胺基乙腈生产过程中会产生含苯胺、苯胺基乙腈、氰化物等高浓度高毒性高氨氮有机废水,可生化性较差。本试验以甲苯为萃取剂,保持原水的pH值不变,相比为0.33,经三级逆流萃取处理后,苯胺、总氰化物、氨氮和COD的萃取率可分别达到约91%、93%、42%和52%,BOD/COD由0.23提高到0.27,提高了废水的可生化性,甲苯可采用酸洗再生加蒸馏再生联合的处理方式。  相似文献   

3.
This study aims to investigate the treatment of paper mill effluents using electrocoagulation. Removal of lignin, phenol, chemical oxygen demand (COD) and biological oxygen demand (BOD) from paper mill effluents was investigated at various current intensities by using different electrodes (Al and Fe) and at various electrolysis times (1.0, 2.5, 5.0 and 7.5min). It was observed that the experiments carried out at 12V, an electrolysis time of 2min and a current intensity of 77.13mA were sufficient for the removal of these pollutants with each electrode. The removal capacities of the process using an Al electrode were 80% of lignin, 98% of phenol, 70% of BOD, and 75% of COD after 7.5min. Using an Fe electrode the removal capacities were 92%, 93%, 80% and 55%, respectively. In addition, it was found that removal of lignin, phenol, BOD and COD increased with increasing current intensity. In the experiments carried out at different current intensities, higher removal can be explained through a decrease in intra-resistance of solution and consequently an increase at the transfer speed of organic species to electrodes. It was also found that Al electrode performs higher efficiency than Fe electrode except for COD removal. However, the time required for removal of BOD was more than that of COD. The results suggest that electrocoagulation could be considered as an effective alternative to paper mill effluents treatment.  相似文献   

4.
采用将脱硫废液与炼油废水按比例混合之后对其进行处理的方法,通过批式试验,考查混合废液的BOD5/COD指标及其COD、NH3-N、S2-的去除率。筛选合适的混合液配比,分别对500︰1和800︰1的混合废液进行了模型试验,分析了COD去除效果。结果表明:800︰1的混合废液在10d之后,出水COD为134mg/L,达到了《污水综合排放标准》(GB8978—1996)二级标准要求。最终确定炼油废水与脱硫废液混合的合适比例应不低于800︰1。  相似文献   

5.
Domestic wastewater contains a considerable amount of pathogenic organisms besides non-biodegradable organics. The conventional technologies followed for the treatment of domestic wastewater are less efficient in removing pathogenic organisms despite substantial removal of dissolved organics. The focal theme of the present investigation was to use a chemo-autotrophic activated carbon oxidation (CAACO) system, an immobilized cell reactor using chemoautotrophs (Bacillus sp.) for the treatment of domestic wastewater. The oxidation of organics and Escherichia coli in wastewater is controlled by the parameters space time, O(2)/COD, bed height and cod loading. The scheme comprised of anaerobic treatment, sand filtration and CAACO treatment removed BOD. COD, Total organic carbon (TOC), dissolved protein, total Kjeldhal nitrogen (TKN) and bacterial count (most probable number (MPN)) by 81%, 92%, 84%, 94%, 93% and 99.9997%, respectively. The low concentration of E. coli in the CAACO-treated wastewater was completely eliminated through UV irradiation in 3 min at 254 nm.  相似文献   

6.
精制棉蒸煮清洗废水(黑液)色度高,成分复杂,属于难处理高浓度有机废水。采用“物化-生化”工艺对其进行处理,BOD、COD、色度、SS去除率分别为95.42%、96.58%、98.25%、70.00%,工程运行稳定,处理费用约为1.93元/m^3。  相似文献   

7.
微生物菌剂在酿酒废水处理中的应用研究   总被引:6,自引:1,他引:5  
采用厌氧-好氧工艺,结合微生物菌剂对酿酒废水进行了处理研究。进水CODCr浓度可达到8,456.3-22,442.0mg/L,BOD55,040.0-9.557.1mg/L,pH3-4,可不调pH,采用微生物菌剂接种可启动厌氧反应器,COD有机负荷最高达到10.2gCOD/Ld,COD去除率稳定在91-95%,BOD去除率90-94%,出水pH6.6-7.1,出水CODCr在2,000mg/L以下,BOD5800mg/L以下。厌氧污泥可全部颗粒化。好氧处理系统中接种微生物菌剂,曝气10-12小时,可保证出水中CODCr在230mg/L以下,甚至直接达到国家一级排放标准。微生物菌剂的应用是取得该处理效果的关键。  相似文献   

8.
IABR-IBAF工艺处理猪场稳定塘废水的实验研究   总被引:1,自引:0,他引:1  
难降解有机物含量高且碳氮比失调是造成养猪场稳定塘废水难于处理的主要原因。本文采用基于固定化微生物技术的厌氧折流板(IABR)与曝气生物滤池(IBAF)组合工艺处理稳定塘废水,对比了IABR-IABF组合工艺与单一IBAF工艺的处理效果,研究了碱度和碳源对硝化反硝化过程的影响。组合工艺平均进水COD1532.6mg/L,平均出水为332.7mg/L,去除率为78%,NH3-N平均进水538.6mg/L,平均出水为12.3mg/L,去除率97.7%。以新鲜废水做反硝化阶段的碳源时TN去除率93%,可有效解决脱氮过程中的碳源成本问题。  相似文献   

9.
Treatment of chemical industrial wastewater from building and construction chemicals factory and plastic shoes manufacturing factory was investigated. The two factories discharge their wastewater into the public sewerage network. The results showed the wastewater discharged from the building and construction chemicals factory was highly contaminated with organic compounds. The average values of chemical oxygen demand (COD) and biochemical oxygen demand (BOD) were 2912 and 150 mgO2/l. Phenol concentration up to 0.3 mg/l was detected. Chemical treatment using lime aided with ferric chloride proved to be effective and produced an effluent characteristics in compliance with Egyptian permissible limits. With respect to the other factory, industrial wastewater was mixed with domestic wastewater in order to lower the organic load. The COD, BOD values after mixing reached 5239 and 2615 mgO2/l. The average concentration of phenol was 0.5 mg/l. Biological treatment using activated sludge or rotating biological contactor (RBC) proved to be an effective treatment system in terms of producing an effluent characteristic within the permissible limits set by the law. Therefore, the characteristics of chemical industrial wastewater determine which treatment system to utilize. Based on laboratory results engineering design of each treatment system was developed and cost estimate prepared.  相似文献   

10.
Anaerobic/aerobic treatment of meat processing wastewater   总被引:2,自引:0,他引:2  
The meat processing industry is believed to produce highly polluted wastewater. Analysis of such wastewater indicated that the waste was highly contaminated with organic compounds as indicated by COD (1544mgO2l–1), BOD (646mgO2l–1), and TSS (1155 mgl–1). Moreover, oil and grease concentrations reached 144mgl–1 treatment of raw wastewater using Upflow Anaerobic Sludge Blanket (UASB) followed by Rotating Biological Contactors (RBC) was studied. Efficiency of the UASB for the removal of CODtotal, BODtotal, TSS, and oil and grease was 56%, 56%, 85%, and 58%, respectively. The quality of the UASB effluent barely complies with the regulatory standards for discharging wastewater into the sewerage network. UASB effluent was subjected for further treatment using a RBC unit to improve the quality of the treated effluent for reuse in irrigation purposes. Residual COD, BOD, TSS, and oil and grease, following RBC, was 132mgO2l–1, 40mgO2l–1, 44mgl–1, and 10mgl–1 respectively. The overall efficiency of the treatment units provided good quality effluent. The overall percentage removal of COD, BOD, TSS, and oil and grease was 91.5%, 94%, 96%, and 91%, respectively. Based on the quality of the treated effluent and guidelines recommended for wastewater reuse, it may be concluded that a slight to moderate restricted irrigation is applicable to reuse the treated effluent in the green belt around the factory. Disinfection should be applied to ensure the safety of such a process.  相似文献   

11.
This study focuses on a lab-scale rotating biological contactor (RBC) treating vegetable oil wastewater with high BOD and COD. The fabricated RBC was checked for efficiency in degrading polluted wastewater under different operating conditions. The maximum removal efficiencies for BOD and COD were 95.75% and 89%, respectively. This high removal percentage was obtained with 30% submergence of 10 discs rotating at 8 rpm. For the first time, bio-kinetic models were applied to the experimental results for vegetable oil wastewater. The best fit was obtained with the modified Stover-Kincannon and Grau model. The saturation constant (Ks) values were 1.872 and 3.024 g/L/d for BOD and COD, respectively, for the modified Stover-Kincannon and Grau model. For the Grau second-order model, the saturation constant was 1.416 and 3.744 g/L/d for BOD and COD, respectively. The predicted effluent BOD and COD values of the modified Stover–Kincannon model fitted almost exactly with the experimental values. This clearly predicts that this model can be best used to predict effluent BOD and COD concentration in a Rotating Biological contactor treating vegetable oil wastewater. The kinetic parameters determined in this study can be used to improve the design and operation of continuous mode RBC systems.  相似文献   

12.
针对炼化企业循环排污水中有机污染物浓度不能满足脱盐处理工艺进水水质要求的问题,开展了臭氧氧化-活性炭吸附工艺去除循环排污水中有机污染物的研究。通过对两种处理工艺进行不同组合的实验结果得知:当反应时间控制在最佳值,臭氧氧化和活性炭吸附单独处理循环排污水时,COD去除率分别约为27%和20%,处理效率偏低;当两种工艺组合后,在臭氧浓度为12 mg/L、氧化时间20 min、吸附时间为10 min时,COD去除率则达到52%,组合工艺协同作用效果明显。  相似文献   

13.
A reliable model for any wastewater treatment plant is essential in order to provide a tool for predicting its performance and to form a basis for controlling the operation of the process. This would minimize the operation costs and assess the stability of environmental balance. This process is complex and attains a high degree of nonlinearity due to the presence of bio-organic constituents that are difficult to model using mechanistic approaches. Predicting the plant operational parameters using conventional experimental techniques is also a time consuming step and is an obstacle in the way of efficient control of such processes. In this work, an artificial neural network (ANN) black-box modeling approach was used to acquire the knowledge base of a real wastewater plant and then used as a process model. The study signifies that the ANNs are capable of capturing the plant operation characteristics with a good degree of accuracy. A computer model is developed that incorporates the trained ANN plant model. The developed program is implemented and validated using plant-scale data obtained from a local wastewater treatment plant, namely the Doha West wastewater treatment plant (WWTP). It is used as a valuable performance assessment tool for plant operators and decision makers. The ANN model provided accurate predictions of the effluent stream, in terms of biological oxygen demand (BOD), chemical oxygen demand (COD) and total suspended solids (TSS) when using COD as an input in the crude supply stream. It can be said that the ANN predictions based on three crude supply inputs together, namely BOD, COD and TSS, resulted in better ANN predictions when using only one crude supply input. Graphical user interface representation of the ANN for the Doha West WWTP data is performed and presented.  相似文献   

14.
宋在兰 《四川环境》2000,19(2):53-55,57
从COD与BOD5的构成及降解动力学出发是新兴的以CODNB/COD为一常数进行研究,得到了BOD5与COD的相关模式。应用五粮液废水的实测数据和数理统计方法对模式进行检验,证明其具有实用性,从而可从COD值快速预报BOD值,此模式适用于城市污水和有机废水。  相似文献   

15.
Combined chemical and biological oxidation of penicillin formulation effluent   总被引:12,自引:0,他引:12  
Antibiotic formulation effluent is well known for its important contribution to environmental pollution due to its fluctuating and recalcitrant nature. In the present study, the chemical treatability of penicillin formulation effluent (average filtered COD(o)=830 mg/l; average soluble COD(o)=615 mg/l; pH(o)=6.9) bearing the active substances penicillin Amoxicillin Trihydrate (C(16)H(19)N(3)O(5)S.3H(2)O) and the beta-lactamase inhibitor Potassium Clavulanate (C(8)H(8)KNO(5)) has been investigated. For this purpose, the penicillin formulation effluent was subjected to ozonation (applied ozone dose=2500 mg/(lxh)) at varying pH (2.5-12.0) and O(3)+H(2)O(2) (perozonation) at different initial H(2)O(2) concentrations (=2-40 mM) and pH 10.5. According to the experimental results, the overall Chemical Oxygen Demand (COD) removal efficiency varied between 10 and 56% for ozonation and 30% (no H(2)O(2)) and 83% (20 mM H(2)O(2)) for the O(3)+H(2)O(2) process. The addition of H(2)O(2) improved the COD removal rates considerably even at the lowest studied H(2)O(2) concentration. An optimum H(2)O(2) concentration of 20 mM existed at which the highest COD removal efficiency and abatement kinetics were obtained. The ozone absorption rate ranged between 53% (ozonation) and 68% (perozonation). An ozone input of 800 mg/l in 20 min was sufficient to achieve the highest BOD(5)/COD (biodegradability) ratio (=0.45) and BOD(5) value (109 mg/l) for the pre-treated penicillin formulation effluent. After the establishment of optimum ozonation and perozonation conditions, mixtures of synthetic domestic wastewater+raw, ozonated and perozonated penicillin formulation effluent were subjected to biological activated sludge treatment at a food-to-microorganisms (F/M) ratio of 0.23 mg COD/(mg MLSSxd), using a consortium of acclimated microorganisms. COD removal efficiencies of the activated sludge process were 71, 81 and 72% for pharmaceutical wastewater containing synthetic domestic wastewater mixed with either raw, ozonated or perozonated formulation effluent, respectively. The ultimate COD value obtained after 24-h biotreatment of the synthetic domestic wastewater+pre-ozonated formulation effluent mixture was around 100 mg/l instead of 180 mg/l which was the final COD obtained for the wastewater mixture containing raw formulation effluent, indicating that pre-ozonation at least partially removed the non-biodegradable COD fraction of the formulation effluent.  相似文献   

16.
中原油田产生的钻井污水的化学需氧量(COD)、矿化度、色度、悬浮物及含油量均比较高,直接外排将会对周边生态环境造成污染,与采油污水混合处理又将导致处理后的水质达不到标准,因而采用将钻井污水处理后再与采油污水混合的方法,这种混合污水进入采油污水处理系统的试验结果表明,处理后的钻井污水与采油污水配伍性良好,净化水无结垢倾向,处理后的净化水与杀菌剂、缓蚀剂相容性良好,其主要指标均达到部颁注水水质标准。  相似文献   

17.
采用莱特生物强化技术(LTBR—Littoral BioReactor),对兰州石化公司化工园区高浓度有机废水进行了中试试验,进行了正常运行的常规标定、水量冲击标定、浓度冲击标定。结果表明:采用LTBR生物处理工艺,使用特效微生物和营养基质,可以在高COD、高含盐等不利条件下正常进行有机物降解,达到了必须将废水中的COD降至2000mg/L以下的试验要求,为处理高浓度有机化工废水的工程应用开辟了新思路。  相似文献   

18.
The remediation of biodiesel wastewater was carried out using chemical and electrochemical techniques. Initially the fatty acid methyl esters (FAME or biodiesel) and free fatty acids (FFA) were chemically removed from the wastewater using three types of mineral acids, H(2)SO(4), HNO(3) and HCl, at different pH values within the range of 1.0-8.0. Optimally, approximately 24.3 ml/l of FAME/FFA were removed from the wastewater when using H(2)SO(4) to set a final pH of 2.5 for 7 min. All pollutant levels were markedly reduced during this step. That is, approximately 38.94%, 76.32% and 99.36% of COD, BOD5 and oil & grease were respectively removed. The acidic aqueous phase left after the removal of the FAME/FFA phase was then treated by chemical- and electro-coagulation processes. The results demonstrated that both investigated treatment processes were effective for treating wastewater from a biodiesel production plant. The chemical coagulation provided a lower operating cost (1.11 USD/m(3)) compared with the electro-coagulation process (1.78 USD/m(3)). However, the latter process provided a better quality of wastewater compared with the former process, with the exception of the BOD levels.  相似文献   

19.
Treatment of low-strength soluble wastewater (COD approximately 500 mg/L) was studied using an eight chambered anaerobic baffled reactor (ABR). At pseudo steady-state (PSS), the average total and soluble COD values (COD(T) and COD(S)) at 8h hydraulic retention time (HRT) were found to be around 50 and 40 mg/L, respectively, while at 10h HRT average COD(T) and COD(S) values were of the order of 47 and 37 mg/L, respectively. COD and BOD (3 day, 27 degrees C) removal averaged more than 90%. Effluent conformed to Indian standards laid down for BOD (less than 30 mg/L). Reactor effluent characteristics exhibited very low values of standard deviation indicating excellent reactor stability at PSS in terms of effluent characteristics. Based on mass balance calculations, more than 60% of raw wastewater COD was estimated to be recovered as CH(4) in the gas phase. Compartment-wise profiles indicated that most of the BOD and COD got reduced in the initial compartments only. Sudden drop in pH (7.8-6.7) and formation of volatile fatty acids (VFA) (53-85 mg/L) were observed in the first compartment due to acidogenesis and acetogenesis. The pH increased and VFA concentration decreased longitudinally down the reactor. Residence time distribution (RTD) studies revealed that the flow pattern in the ABR was neither completely plug-flow nor perfectly mixed. Observations from scanning electron micrographs (SEM) suggest that distinct phase separation takes place in an ABR.  相似文献   

20.
混凝沉降-生物膜法处理制革废水   总被引:8,自引:0,他引:8  
郑新萍 《环境技术》2004,22(4):18-19,22
采用混凝沉降-生物膜法处理蓝湿牛皮制革废水。工程实践证明:该法对废水COD和BOD的去除率可达94%以上,且对废水的脱色效果良好,是一种合理有效的处理皮革废水工艺路线。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏