首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the framework of new European directives in the field of ambient air quality assessment specific requirements for measurement methods for benzene will be defined and have to be met in the future. In a residential area in the vicinity of a cokery a comprehensive monitoring programme for BTX compounds (benzene, toluene, xylenes) was carried out with diffusive samplers. Measurement results from 20 sites show a distinct spatial distribution of benzene concentrations which is caused by the emissions of the plant. Comparisons with two pumped measurement methods reveal excellent agreement in the case of benzene. An assessment of measurement uncertainty for the diffusive method is presented in terms of standard deviations from parallel measurements (precision) and by comparison with a reference method according to national and international standards. Data quality objectives required by an upcoming European directive for benzene can be met by diffusive sampling.  相似文献   

2.
Analytical results obtained by thermal desorption GC/MS for 24 h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive sampling tubes and one passivated canister. A total of eight multiple-component sampling events took place at fixed positions inside and outside three private homes. Subsequently, a known amount of sample air was transferred from the canister to an adsorbent tube for analysis by thermal desorption GC/MS. Results for the 11 most prevalent compounds--Freon 11, 1,3-butadiene, benzene, toluene, tetrachloroethene, ethylbenzene, m,p-xylene, o-xylene, 4-ethyltoluene, 1,3,5-trimethylbenzene, and p-dichlorobenzene--show that the ratio of average study values (diffusive sampling to active sampling) is 0.92 with 0.70 and 1.14 extreme ratios. Absolute percent difference for duplicate samples using diffusive sampling was <10% for the four most prevalent compounds. Agreement between the two sampling approaches indicates that the prediction of approximately constant diffusive sampling rates based on previous laboratory studies is valid under the field conditions.  相似文献   

3.
Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of the children, and the median concentrations were 21.7, 20.9, 10.1, and 21.5 μg m(-3), respectively. This study shows that the diffusive samplers developed were suitable for children to carry and were capable of measuring the children's daily chemical exposure.  相似文献   

4.
This study presents an evaluation of the extent of differences between measurements performed by O(3) and NO(2) diffusive samplers and by the reference methods for diffusive samplers commercially available. The tests were performed in an exposure chamber under extreme conditions of controlling factors and under field conditions. For NO(2), the results of the laboratory experiments showed that most of the diffusive samplers were affected by extreme exposure conditions. The agreement between the samplers and the reference method was better for the field tests than for the laboratory ones. The estimate of the uptake rate for the exposure conditions using a model equation improved the agreement between the diffusive samplers and the reference methods. The agreement between O(3) measured by the diffusive samplers and by the reference method was satisfactory for 1-week exposure. For 8-hour exposures, the diffusive samplers with high uptake rates quantified better the O(3) concentration than the samplers with low uptake rates. As for NO(2), the results of the O(3) field tests were in better agreement with the reference method than the ones of the laboratory tests. The field tests showed that the majority of diffusive samplers fulfils the 25% uncertainty requirement of the NO(2) European Directive and the 30% uncertainty requirement of the O(3) European Directive for 1-week exposure.  相似文献   

5.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

6.
Results from a five month monitoring campaign of BTX (benzene, toluene and the sum of ethyl benzene, o-xylene, m-xylene and p-xylene), performed at Monterotondo, a little town 23 km NE of Rome, and correlation of the measured concentrations with meteorological and natural radioactivity data are presented and discussed. This campaign allowed us to extrapolate a pattern of the annual distribution of benzene in the town. A map, showing the average distribution of pollutants, is presented, as a useful tool to manage an appropriate policy of air pollution. A contemporary indoor-outdoor investigation has been performed at five homes and two classrooms of Monterotondo and at thirteen homes and thirteen classrooms in the outskirts of Rome. Non-smoking people and low polluted sites were chosen for this campaign, in order to highlight if commonly used domestic materials could act as internal sources. Data, obtained by employing long-term diffusive samplers, are compared with a parallel experiment showing the day-night indoor-outdoor trend. The obtained results, confirmed through statistical analysis of data, let us conclude that there is evidence of internal sources at homes whilst, in the schools, depletion phenomena prevail, probably due to the walls adsorption.  相似文献   

7.
The Building Research Establishment (BRE) has been using diffusive samplers for the study of VOCs in indoor and outdoor air since 1989. The Perkin Elmer type sampler packed with Tenax TA adsorbent is used for the diffusive sampling of C6-C16 organic compounds. This method was applied in a major study of relationships between the environment and child health carried out during 1990-1993 in the Avon area of the UK. The present paper reports results of an investigation into the repeatability of the sampler in outdoor air and measurements of 6 aromatic hydrocarbons inside and outside a home over a 5 year period and inside and outside an office building over a 12 month period. Both the home and the office were located in Hertfordshire, England. Concentrations of VOCs recorded are similar to those found in the Avon area. Higher concentrations of each of the six compounds were recorded inside the home than outside, whilst greater amounts of benzene and toluene were found inside the office than outside. Seasonal variations in concentrations are observed and measurements recorded outdoors are similar to those recorded by other workers.  相似文献   

8.
Tube type samplers with two different adsorbents, Chromosorb 106 and Tenax TA, were evaluated by laboratory experiments and field tests for simultaneous diffusive sampling of alpha-pinene, beta-pinene and delta 3-carene and subsequent thermal desorption-gas chromatographic analysis. No statistically significant effects of exposure time, concentrations of monoterpenes or relative humidity were found for samplers with Chromosorb 106 when running a factorial design, with the exception of the adsorption of delta 3-carene, for which some weak effects were noted. Samplers with Tenax TA were affected by the sampling time as well as the concentration for all terpenes, with a strong interaction effect between these two factors. The terpenes showed good storage stability on both adsorbents. No effect of back-diffusion was noted when using Chromosorb 106, while Tenax TA showed some back-diffusion effects. The uptake rates, in ml min-1, for the terpenes on Chromosorb 106 were 0.36 for alpha-pinene, 0.36 for beta-pinene and 0.40 for delta 3-carene. The corresponding average values on Tenax TA were 0.30 for alpha-pinene, 0.32 for beta-pinene and 0.38 for delta 3-carene. The field validation proved that diffusive sampling on Chromosorb 106 agreed well with pumped sampling on charcoal for stationary samples, while the personal samples indicated a discrepancy of 25% between Chromosorb 106 and charcoal samples. Tenax TA generally gave lower results than Chromosorb 106 in all field samples. Samplers packed with Chromosorb 106 could be used to monitor terpene levels in workplaces such as sawmills. The major advantages with this method are the sampling procedure, which is simple to perform compared to other techniques, the easily automated analysis procedure and the possibility to reuse the samplers.  相似文献   

9.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   

10.
A study of the equivalence to the reference methods of the Radiello samplers for ozone (O(3)) and benzene as well as the membrane-closed Palmes tube (MCPT) for nitrogen dioxide (NO(2)) is presented. These samplers benefit from new model equations capable of estimating their uptake rate. For O(3), the aim here was to demonstrate the equivalence for the reference period of 8 h and 120 microg m(-3), the target value of the 3rd European Daughter Directive. For benzene, the demonstration of equivalence to the annual limit value of 5 microg m(-3) of the 2nd European Daughter Directive was examined. In the case of NO(2), the equivalence to the annual limit value of the 1st European Daughter Directive (40 microg m(-3)) was considered. Results show that the radial sampler for O(3) fails to meet the Data Quality Objective (DQO) for continuous monitoring. However, with an expanded uncertainty of less than 30%, the O(3) diffusive sampler fulfils the DQO for indicative measurements. For benzene, the Radiello sampler exposed for 7 days gave satisfying results showing the ability of the sampler to meet the DQO of the reference method. Nevertheless, the field tests should be complemented by measurements for a wider range of benzene concentrations. In the case of NO(2), all the results of the laboratory and field experiments respected the requirements necessary for the demonstration of equivalence. Overall, these findings thus show that the Radiello sampler and the MCPT are equivalent to the reference methods only for assessment of benzene and NO(2), respectively.  相似文献   

11.
Within the Sino-Italian environmental protection cooperation framework established in 2002, a comprehensive air quality monitoring network has been developed in urban Suzhou, a medium-sized Chinese city, in compliance with European standards (Directive 96/62/EC). This paper is among the first attempts to present a systematic and scientific analysis of benzene, toluene, and xylenes (BTX) pollution in China. It presents our analysis of BTX space-related and time-related measurement results. Background BTX concentrations were investigated by passive sampler Analyst® in 2003. We depicted the spatial distribution of average BTX concentrations collected from three 15-day campaigns on isoconcentration maps. This is the first time such detailed BTX concentration maps have been developed in China in a city scale. Continuous measurement of BTX by automatic gas chromatography was carried out at two fixed monitoring stations, one in an urban residential zone and one in a heavy traffic zone, from April to December 2005. The results show similar seasonal trends at both sites, the similarities reaching their greatest level in December and their lowest level in August. The average daily profile of BTX shows greater fluctuation in spring and winter with clear morning and evening peaks. Daily average benzene, toluene, and m,p-xylenes concentrations for the study period were 2.64, 11.52, and 3.52 μg m???3, respectively. The benzene/toluene ratio we found was lower in Suzhou than those published in studies of other worldwide cities, which indicates serious levels of toluene pollution from local stationary sources. The similarities in seasonal trend and spatial distribution in these manual and automatic measurement results were compared with each other, though the concentration values differed.  相似文献   

12.
Healthcare settings present a challenging environment for assessing low-level concentrations of specific volatile organic compounds (VOCs) in the presence of high background concentrations of alcohol from the use of hand sanitizers and surface disinfectants. The purposes of this laboratory-based project were to develop and validate a sampling and analysis methodology for quantifying low-level VOC concentrations as well as high-level alcohol concentrations found together in healthcare settings. Sampling was conducted using evacuated canisters lined with fused silica. Gas chromatography/mass spectrometry analysis was performed using preconcentration (for ppb levels) and loop injection (for ppm levels). For a select list of 14 VOCs, bias, precision, and accuracy of both the preconcentration and loop injection methods were evaluated, as was analyte stability in evacuated canisters over 30 days. Using the preconcentration (ppb-level) method, all validation criteria were met for 13 of the 14 target analytes-ethanol, acetone, methylene chloride, hexane, chloroform, benzene, methyl methacrylate, toluene, ethylbenzene, m,p-xylene, o-xylene, alpha-pinene, and limonene. Using the loop injection (ppm-level) method, all validation criteria were met for each analyte. At ppm levels, alpha-pinene and limonene remained stable over 21 days, while the rest of the analytes were stable for 30 days. All analytes remained stable over 30 days at ppb levels. This sampling and analysis approach is a viable (i.e., accurate and stable) methodology that will enable development of VOC profiles for mixed exposures experienced by healthcare workers.  相似文献   

13.
Measurements of fortnightly average concentrations of NO, NO2, SO2, H2S, NH3, and volatile organic compounds (VOCs) (aromatics = benzene, toluene, o-xylene, m + p-xylene, ethyl benzene; non-aromatics = nonane and octane) were carried out in the period from 26/10/05 to 24/11/05 at 20 points in the southern part of Kuwait as part of a baseline environmental impact assessment study requested by Kuwait National Petroleum Company. Two waves of triplicate diffusive passive samplers were used. A high volume air sampler was used to measure PM10 too. During the sampling period, the wind was observed to be mainly from the west and northwest with an average of 4.28 m/s. The consistency of the results allowed the production of spatial distribution maps of the pollutants measured and consequently the comparison between levels of air pollution at different locations. A comparison between the measured concentrations and the applicable air quality standards promulgated by Kuwait Environment Public Authority (KEPA) showed that those compounds had low concentrations compared to both industrial and residential KEPA standards. For other compounds which are not covered by KEPA standards, the results were compared with relevant limits of US Environment Protect Agency (USEPA) and US Department of Labor, Occupational Safety and Health Administration. The comparison showed that the measured compounds had low concentrations compared to the existing standards and, accordingly, no violation of air quality standards is reported.  相似文献   

14.
差分光谱法连续监测空气中SO2、NO2、苯、甲苯方法探讨   总被引:1,自引:0,他引:1  
差分光谱法(简称DOAS)已广泛用于空气中SO2、NO2、苯、甲苯监测.通过对差分光谱法监测结果与其他传统仪器进行时比,发现用DOAS监测SO2、NO2与点式仪器有较好的一致性,但用DOAS系统监测苯、甲苯与气相色谱法有机物连续监测结果差异较大,相关性较差,运行有一定的局限性.另外,本文对DOAS的最佳运行条件进行了探讨,发现影响光强的氙灯老化和气候条件对DOAS系统运行有较大影响.  相似文献   

15.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

16.
This study investigated the biomarker responses of the earthworm, Eudrilus eugeniae, exposed to sublethal concentrations of benzene, toluene and xylene (BTX) for a time span of 28 days. Lipid peroxidation (LPO) and histopathological alterations were examined. Toxicological evaluations of BTX were carried out against E. eugeniae. On the basis of the 96-h LC50 value, xylene (1.212 mg/kg) was found to be the most toxic followed by toluene (1.335 mg/kg) and benzene (1.896 mg/kg) was the least toxic. The exposure of earthworms to sublethal concentrations (1/10th and 1/100th of 96 h LC50) of BTX premixed with the substrate (loamy and humus soil) induced pathological changes in the clitella such as severe lesion, necrosis and dark brown pigments. The result of the lipid peroxidation assay showed a significant increase in oxidative damage with LPO values ranging from 2.58–7.8 nM/g in exposed animals when compared to 0.07 nM/g in the control group. The findings from this study suggest the use of LPO and histopathology as useful biomarkers of exposure for early detection of petroleum related stress in terrestrial ecosystems  相似文献   

17.
Diffusive samplers were used to measure the vertical concentrations of benzene, toluene, n-hexane, cyclohexane, ethylbenzene and o-, m- and p-xylenes on both sides of two NS-oriented street canyons in Murcia (Spain) during a 5-day period. Non-dimensional relationships of concentration and height were calculated in order to study the behaviour of their concentration vertical profiles. The results show that the vertical profiles of benzene, toluene, n-hexane and cyclohexane concentrations were similar in both streets and on both sides of each street. Some differences were found in vertical profiles between streets and sides for ethylbenzene and xylenes, probably due to their higher affinity for adsorption into building materials. The similarities found for the first set of VOCs suggest that the dynamics of the dispersion was the same for both streets and was mainly influenced by microscale thermal effects. Finally, the concentration measurements of benzene, toluene, n-hexane, cyclohexane, and ethylbenzene were adjusted to expressions in the form c?=?c 0(h/h 0) A , and a regression coefficient R 2?=?0.962 (p?=?0.0000) was obtained. The decreasing concentration of these compounds with height should be taken into account when assessing population exposure to these pollutants.  相似文献   

18.
A method based on headspace (HS) sampling coupling with portable gas chromatography (GC) with photo ionization detector (PID) was developed for rapid determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) in soils. Optimal conditions for HS gas sampling procedure were determined, and the influence of soil organic matter on the recovery of BTEX from soil was investigated using five representative Chinese soils. The results showed that the HS-portable-GC-PID method could be effectively operated at ambient temperature, and the addition of 15 ml of saturated NaCl solution in a 40-ml sampling vial and 60 s of shaking time for sample solution were optimum for the HS gas sampling procedure. The recoveries of each BTEX in soils ranged from 87.2 to 105.1 %, with relative standard deviations varying from 5.3 to 7.8 %. Good linearity was obtained for all BTEX compounds, and the detection limits were in the 0.1 to 0.8 μg kg?1 range. Soil organic matter was identified as one of the principal elements that affect the HS gas sampling of BTEX in soils. The HS-portable-GC-PID method was successfully applied for field determination of benzene and toluene in soils of a former chemical plant in Jilin City, northeast China. Considering its satisfactory repeatability and reproducibility and particular suitability to be operated in ambient environment, HS sampling coupling with portable GC-PID is, therefore, recommended to be a suitable screening tool for rapid on-site determination of BTEX in soils.  相似文献   

19.
Diffusive samplers for monitoring of air quality are user-friendly devices that can normally be operated by the user himself. Hence these samplers are suitable for self-assessment. Practical and work organisational aspects of self-assessment of chemical exposure were studied in different occupational settings. It was found that the diffusive sampler used in these studies, the Perkin-Elmer tube in combination with thermal desorption, worked well for the purpose and could be correctly handled by the individuals using it. The results from self-assessments agreed well with expert measurements carried out by an occupational hygienist. However, in order to obtain a sustainable system of self-assessment strong organizational support is needed.  相似文献   

20.
Long-term phenol, cresols and BTEX monitoring in urban air   总被引:1,自引:0,他引:1  
This paper reports the results of a long-term monitoring of benzene, toluene, ethylbenzene, xylenes (BTEX), phenol and cresols in the air of Padua during a wide period of the year 2007 using two radial passive samplers (Radiello system) equipped with BTEX- and phenol-specific cartridges. Two sites were monitored, one in the industrial area and one close to the town centre. Relevant pollution episodes have been observed during both the winter and summer periods. Benzene, together with toluene, ethylbenzene and xylenes showed their maximum concentrations during the winter season, but the secondary pollutant phenol was higher than benzene for a large period of the year when the meteorological conditions blocked the pollutants in the lower layers of the atmosphere and solar radiation increased the benzene photo-oxidation process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号