首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 36 毫秒
1.
The aim of this work is to establish baseline levels of pharmaceuticals in three wastewater treatment plant (WWTP) streams in the greater Dublin region to assess the removal efficiency of the selected WWTPs and to investigate the existence of any seasonal variability. Twenty compounds including several classes of antibiotics, acidic and basic pharmaceuticals, and prescribed medications were selected for investigation using a combination of membrane filtration, solid phase extraction (SPE) cleanup, and liquid chromatography–electrospray ionization tandem mass spectrometry. Fourteen of the selected compounds were found in the samples. Increased effluent concentrations, compared to influent concentrations, for a number of compounds (carbamazepine, clotrimazole, propranolol, nimesulide, furosemide, mefenamic acid, diclofenac, metoprolol, and gemfibrozil) were observed. The detected concentrations were generally below toxicity levels and based on current knowledge are unlikely to pose any threat to aquatic species. Mefenamic acid concentrations detected in both Leixlip and Swords effluents may potentially exert ecotoxicological effects with maximum risk quotients (i.e., ratio of predicted exposure concentration to predicted no effect concentration) of 4.04 and 1.33, respectively.  相似文献   

2.
Royal Commission Environmental Control Department (RC-ECD) at Yanbu industrial city in Kingdom of Saudi Arabia has established a well-defined monitoring program to control the pollution from industrial effluents. The quality of effluent from each facility is monitored round the clock. Different strategic measures have been taken by the RC-ECD to implement the zero discharge policy of RC. Industries are required to pre-treat the effluent to conform pretreatment standards before discharging to central biological treatment plant. Industries are not allowed to discharge any treated or untreated effluent in open channels. After treatment, reclaimed water must have to comply with direct discharge standards before discharge to the sea. Data of industrial wastewater collected from five major industries and central industrial wastewater treatment plant (IWTP) is summarized in this report. During 5-year period, 3,705 samples were collected and analyzed for 43,436 parameters. There were 1,377 violations from pretreatment standards from all the industries. Overall violation percentage was 3.17%. Maximum violations were recorded from one of the petrochemical plants. The results show no significant pollution due to heavy metals. Almost all heavy metals were within RC pretreatment standards. High COD and TOC indicates that major pollution was due to hydrocarbons. Typical compounds identified by GC-MS were branched alkanes, branched alkenes, aliphatic ketones, substituted thiophenes, substituted phenols, aromatics and aromatic alcohols. Quality of treated water was also in compliance with RC direct discharge standards. In order to achieve the zero discharge goal, further studies and measures are in progress.  相似文献   

3.
The present study investigated the occurrence of 29 selected micropollutants such as endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care products (PPCPs) in surface waters and wastewaters in Seoul (South Korea) during both dry and wet weather conditions. The study area was selected based on the lack of available information regarding the suspected contamination of rivers/creeks by EDCs and PPCPs in the Seoul region and the presence of a wastewater treatment plant (WWTP), which serves approximately 4.1 million inhabitants and has a design capacity of 1,297?×?103 m3/day. Many target compounds (83 %) were detected in samples collected from wastewater treatment influent/effluent, creek water, and combined sewer overflow (CSO). The total EDC/PPCP concentrations were as follows: WWTP influent (69,903 ng/L)?>?WWTP effluent (50,175 ng/L) >3 creek samples (16,035–44,446 ng/L) during dry weather, and WWTP influent (53,795 ng/L)?>?WWTP bypass (38,653 ng/L) >5 creek samples (15,260–29,113 ng/L) >2 CSO samples (11,109–11,498 ng/L) during wet weather. EDCs and PPCPs were found to be present at high daily loads (65.1 and 69.8 kg/day during dry and wet weather, respectively) in the WWTP effluent. Compound removal by the WWTP varied significantly by compound: caffeine, diclofenac, ibuprofen, naproxen, and propylparaben (>90 %), and acesulfame, DEET, iohexol, iopromide, and iopamidol (<5 %). These findings and literature information support the hypothesis that the efficiency of removal of EDCs and PPCPs is strongly dependent on both removal mechanism (e.g., biodegradation, adsorption to sludge, and oxidation by chlorine) and compound physicochemical properties (e.g., pK a and hydrophobicity).  相似文献   

4.
An analytical procedure for the simultaneous determination of six selected endocrine disrupter compounds (EDCs: diltiazem, progesterone, benzyl butyl phthalate (BBP), estrone, carbamazepine (Cbz), acetaminophen) was developed by liquid chromatography electrospray ionization tandem mass spectrometry (HPLC-ES-MS/MS). All of the parameters for HPLC and ES-MS/MS systems including mobile phase composition, flow rate, and sample injection volume were optimized to obtain not only the best separation of species interested but also low detection limits. Reverse phase chromatography coupled to ES-MS/MS was used for the separation and detection of EDCs. Formic acid (0.10% ) and 5.0 mM ammonium formate were selected as mobile phase composition in gradient elution. Detection limits for diltiazem, progesterone, BBP, estrone, Cbz, and acetaminophen were found to be 0.13, 0.12, 0.04, 0.13, 0.12, and 0.05 ng/mL, respectively. Influent and effluents from three different wastewater treatment plants located in Ankara, i.e., rotating flat-sheet membrane unit, pilot type flat-sheet membrane unit located at METU Campus and samples from Ankara central wastewater treatment plant were analyzed for their EDCs contents under the optimum conditions.  相似文献   

5.
Gaseous volatiles from wastewater samples taken from a local sewage treatment plant were air-stripped and trapped onto Tenax GC. These volatiles were then thermally desorbed and subsequently analyzed using a gas chromatograph coupled to a mass spectrometer (GC-MS). The results show that saturated aliphatic and aromatic hydrocarbons were the most dominant compounds found in the sewage gaseous volatiles. Other compounds found were chlorinated hydrocarbons, organic acids, sulfides and phenols. A wide variety of gaseous volatiles were found in the raw wastewater, the primary clarifier effluent, the pre-aeration wastewater and the sludge samples. A comparison of the gas chromatograms for the pre- and post-aeration wastewater shows that many odorous gaseous volatiles were removed during the aeration process in the treatment plant.  相似文献   

6.
A rugged and specific method based on tandem solid-phase extraction and liquid chromatography-tandem mass spectrometry for the determination of anti-infectives in raw sewage and wastewater plant effluents was developed. Analyte recoveries from spiked effluents ranged from 68 to 104%. Two specific selected reaction monitoring transitions and their peak area ratios were used to avoid false positives and confirm the presence of the targeted substances. Detection limits allowed low nanogram per litre detection (0.3-22 ng L(-1)). The method was successfully applied to real samples from the Montréal wastewater treatment plant. All the studied anti-infectives were found in the wastewater samples in concentrations ranging from 39 to 276 ng L(-1). Mean flows of anti-infectives were estimated from effluent concentrations and it was found that large amounts (>118 g day(-1) up to 830 g day(-1)) are discharged in the receiving waters of the St Lawrence River.  相似文献   

7.
The presence of the anesthetic lidocaine (LDC), the analgesic tramadol (TRA), the antidepressant venlafaxine (VEN) and the metabolites O-desmethyltramadol (ODT) and O-desmethylvenlafaxine (ODV) was investigated in wastewater treatment plant (WWTP) effluents, in surface waters and in groundwater. The analytes were detected in all effluent samples and in only 64% of the surface water samples. The mean concentrations of the analytes in effluent samples from WWTPs with wastewater from only households and hospitals were 107 (LDC), 757 (TRA), 122 (ODT), 160 (VEN) and 637 ng L(-1) (ODV), while the mean concentrations in effluents from WWTPs treating additionally wastewater from pharmaceutical industries as indirect dischargers were for some pharmaceuticals clearly higher. WWTP effluents were identified as important sources of the analyzed pharmaceuticals and their metabolites in surface waters. The concentrations of the compounds found in surface waters ranged from 相似文献   

8.
The occurrence of twenty pharmaceutical compounds was quantitatively determined in effluents from two major Oslo city hospitals, Rikshospitalet and Ullev?l, along with influent, sludge and final effluent from the city's VEAS wastewater treatment works (WTW). Composite hospital effluents were collected over a twelve week period and were showed to contain paracetamol, metoprolol, diclofenac, ibuprofen, 17beta-Estradiol, estriol, estrone, oxytetracycline, tetracycline, doxycycline, chlorotetracycline, demeclocycline, trimethoprim, ciprofloxacin, sulfamethoxazole, cyclophosphamide and ifosfamide. Three pharmaceuticals were not detected above the limit of detection; cefuroxime, 17alpha-ethinylestradiol and meclocycline. Composite influent, sludge and effluent samples were collected from VEAS WTW over a seven week period. The influent into VEAS WTW contained all of the same selected substances detected in the hospital effluents, except for oxytetracycline, chlorotetracycline, demeclocycline, cyclophosphamide and ifosfamide. The percentage of pharmaceuticals entering the works from the hospitals was <10% for all of the selected compounds. VEAS sludge samples contained a different profile of substances reflecting their physico-chemical properties. Hydrophobic antibiotics, such as oxytetracycline, tetracycline and ciprofloxacin, were detected in all of the collected sludge samples. Their absence in the collected influent samples suggests that they enter the works bound to effluent particles, with the dissolved fraction observed in the hospital effluents partitioning onto particulate matter within the sewerage network. The final effluent from VEAS WTW contained reduced concentrations of many pharmaceuticals, including paracetamol, ibuprofen and sulfamethoxazole. For other compounds, such as metoprolol, diclofenac and trimethoprim, there were often higher concentrations in the effluent than the influent. These effluent concentrations represent median inputs varying from low g day(-1) (e.g. paracetamol and ibuprofen) to nearly 200 g day(-1) (e.g. metoprolol and trimethoprim) into Oslofjord. A simple risk assessment showed that the antibiotic ciprofloxacin may at times pose an acute risk to the Oslofjord aquatic environment.  相似文献   

9.
Stable nitrogen isotope ratios are routinely used to trace the dispersion and assimilation of wastewater-derived N in receiving environments, but few isotope studies have investigated wastewater treatment plants and ponds themselves. An improved understanding of N isotope compositions in effluent will help assess treatment plant processes and performance and will help trace sources of excess nutrients in receiving environments. Here, we assess N budgets and treatment processes in seven wastewater treatment plants and wastewater stabilisation ponds in northern Australia based on concentrations and isotope ratios of N in effluent. We show that δ15N values in effluent are linked to treatment type, effectiveness of conversion of ammonia and levels of gaseous N emissions. These relationships suggest that N isotope monitoring of wastewater treatment plants and ponds can provide an integrated assessment of treatment performance and gaseous N emissions on a pond- or plant-wide scale that is not readily available through other methods. Our findings further imply that monitoring N isotope ratios in receiving environments cannot be assumed to be universally effective as their sensitivity to uptake of wastewater-derived N will vary with the characteristics of individual treatment systems. Paradoxically, N isotope monitoring is less effective where treatment systems are functioning poorly and where monitoring needs are the greatest.  相似文献   

10.
In order to evaluate the chromium (Cr) contamination due to the discharge of waste waters from the tannery of Jijel in the Mouttas river (Algeria), samples of water, sediment and vegetation (Agropyrum repens) were collected during a 6 month period in four stations located upstream (control) and downstream of the tannery. The total chromium was measured by atomic absorption spectrophotometry. Metal inputs were clearly related to effluent discharges from the tannery into the river. Although only traces of chromium were found in water samples upstream of the tannery, very high concentrations (up to 860 times higher) were detected downstream. The contamination was not limited to water of Mouttas River because a same difference in chromium concentrations was also found in sediments and plants Agropyrum repens that were sampled upstream and downstream of the tannery. This work showed that the treatment process used in the wastewater treatment plant of the tannery of Jijel is not able to remove the chromium detected in their influents. The occurrence and chromium levels detected in the aquatic environment represent a major problem concerning drinking water resources and environmental protection of water bodies.  相似文献   

11.
Tris(chloro-isopropyl)phosphate (TCPP) was identified by GC-MS by comparing mass spectra and retention times to original standards. The concentrations in wastewater of a sewage treatment plant's influent and effluent were analysed (520 ng l(-1) and 380 ng l(-1), respectively (mean values). The concentrations of TCPP in the wastewater inflow exhibited a high variability. The elimination of this compound in the sewage treatment plant also exhibits a high variability but is low. Additionally the concentrations in sewage sludge of the same plant were determined (mean value 5100 ng g(-1) dry weight; 1700 ng g(-1) wet weight, respectively). For a comparison sludge samples from twenty other plants were analysed. In these samples concentrations ranging from 1000-20000 ng g(-1)(dry weight) were determined. Thus sorption to sludge does occur to some extent.  相似文献   

12.
Endocrine-disrupting compounds (EDCs) are exogenous substances that cause adverse health effects in an intact organism, or its progeny, subsequent to the changes in endocrine function. Recent studies have shown that wastewater treatment plant effluents play an important role in the release of EDCs into aquatic environments. Therefore, in this study, influent and effluent samples from three different wastewater treatment plants (WWTPs) in Istanbul were analysed for the presence of the principal EDCs. These chemicals include steroids and synthetic organic chemicals. Thus, the occurrence and fate of EDCs of great health concern were monitored at three WWTPs in Istanbul. Furthermore, these WWTPs are employing different treatment processes. Therefore, the EDC removal performances of different treatment regimes were also evaluated. Phytosterol was the most abundant EDC in the influent samples. Second group of compounds at high influent levels were alkyl phenols. Pesticide levels of all three WWTP influent samples were low. Pasakoy Advanced WWTP is more effective at eliminating EDCs. Kadikoy Primary WWTP exhibits the lowest EDC elimination efficiencies. To the best of our knowledge, this work comprises the first detailed report on the occurrence and behaviour of both natural and synthetic EDCs in WWTPs of Istanbul and Turkey. The steroid estrogen levels of this study are higher than the previously documented values, except the levels given for Gaobeidian WWTP in Beijing, China. This is attributed to higher population densities of Beijing and Istanbul and as well as to lower individual water consumption rates in the two cities.  相似文献   

13.
As wastewater reclamation and reuse becomes more widespread, risks of exposure to treated wastewater increase. Moreover, an unlimited number of pollutants can be identified in wastewater. Therefore, comprehensive toxicity assessment of treated wastewater is imperative. The objective of this study was to perform a comprehensive toxicity assessment of wastewater treatment systems using stress response bioassays. This powerful tool can comprehensively assess the toxicity of contaminants. In this study, samples from conventional activated sludge treatment, membrane bioreactors (MBRs) with different pore sizes and sludge retention times (SRTs), rapid sand filtration, coagulation, nano-filtration (NF) and reverse osmosis (RO) were investigated. The results of stress response bioassays confirmed that the secondary effluent showed higher stress response than influent indicating that biological treatment generates toxic compounds. The results obtained from molecular weight fractionation of water samples demonstrated that organic matter with a higher molecular weight fraction (>0.1 μm) causes toxicity in secondary effluent. Furthermore, supernatant from MBR reactors showed toxicity regardless of SRT. On the other hand, stress response was not detected in MBR permeates except for an MBR equipped with a larger pore size membrane (0.4 μm) and with a short SRT (12 days). While rapid sand filtration could not remove the toxic compounds found in secondary effluent, coagulation tests, operated at an appropriate pH, were effective for reducing stress response in the secondary effluent. Experimental findings also showed that stress response was not detected in cases of NF and RO permeate subsequent to MBR treatment.  相似文献   

14.
Fate Modelling of DEHP in Roskilde Fjord, Denmark   总被引:1,自引:0,他引:1  
The fate of di(2-ethylhexyl)phthalate (DEHP) is modeled in Roskilde fjord, Denmark. The fjord is situated near Roskilde, which comprises 80,000 PE, various industries, a central wastewater treatment plant, and adjacent agricultural fields. Roskilde fjord is thus a suitable recipient for studying the transport and fate of DEHP, which is used in a variety of different industries and consumer products. Wastewater from households and industries is led to the local wastewater treatment plant, which leads the effluent to the fjord. The sludge is partly stored and partly amended on an adjacent field. The model applied in the present study is a simple box model coupling water and sediment compartments of the fjord with wastewater treatment plant effluent, streams leading to the fjord, and atmospheric deposition. The fjord model comprises first-order degradation, adsorption, sedimentation, vertical diffusion in the sediment, dispersive mixing in the water, and water exchange with the surrounding sea. Experimental measurements of DEHP were made in the fjord water and sediment, in the wastewater treatment plant inlet and effluent, and in streams and atmospheric deposition. The experimental data are used to calibrate the model. The model results show that freshwater from streams is the predominant DEHP source to the fjord, followed by atmospheric deposition and effluents from wastewater treatment plants. Sedimentation is the predominant removal mechanism followed by water exchange with the sea and degradation.  相似文献   

15.
The occurrence of the metabolites of five human pharmaceuticals was investigated in treated wastewater, surface waters and sediments. Metabolites of carbamazepine (carbamazepine epoxide), diclofenac (4'- and 5-hydroxy diclofenac) and atorvastatin (o- and p-hydroxy atorvastatin) were typically detected in flow proportional 24 h composite samples of wastewater effluent collected from the Norwegian cities of Oslo and Troms? at higher concentrations than the parent pharmaceutical. The concentrations determined in discharged effluent were as high as 3700 ng L(-1) for 5-hydroxy diclofenac. The overall mean concentration of metabolites being typically higher in the primary treated effluent from the city of Troms? compared to the tertiary treatment performed on the Oslo effluent. Metabolites of carbamazepine (carbamazepine-10,11-epoxide), metoprolol (α-hydroxy metoprolol) and simvastatin (hydroxy simvastatin) were detected in surface water samples collected from Oslofjord at concentrations of up to 108 ng L(-1), whilst α-hydroxy metoprolol and simvastatin hydroxy carboxylic acid were also detected in sediments at low ng L(-1) concentrations. These screening data show that the metabolites of selected pharmaceuticals are being discharged into the Norwegian coastal environment and that certain metabolites occur in marine surface waters and sediments.  相似文献   

16.
The lack of information and the need for knowledge on the organic pollutants within the area of KwaZulu-Natal together with the global problem of water supply have prompted our investigation into the analyses of eight polychlorinated biphenyl (PCB) congeners in the Msunduzi River of KwaZulu-Natal, South Africa. Soil, sediment, and water samples were collected at ten different sites along the river during winter and spring seasons. Soil and sediment samples were extracted using ultra sonication with dichloromethane while water samples were liquid-liquid extracted using dichloromethane. All sample extracts were cleaned-up using a multi-layer silica gel column and analyzed with gas chromatography-mass spectrometry. Quality assurance measures were also determined. The percentage recoveries for water were 53–128 for all the PCBs analyzed, while sediment recoveries ranged between 69 and 105%. The highest total concentrations of the PCBs in sediment were 214.21–610.45 ng/g dw at the Du Toit sampling site and 30.86–444.43 ng/g dw basis at the wastewater treatment inlet for winter and spring, respectively. Soil PCB concentrations were 76.53–397.75 ng/g dw at the Msunduzi Town sampling site and 20.84–443.49 ng/g (dry weight) at the Du Toit sampling site for winter and spring, respectively. In addition, high PCB concentrations were found in effluent of the wastewater treatment inlet compared to other sampling sites, which ranged between 0.68–22.37 and 2.53–35.69 ng/mL for winter and spring seasons, respectively. In all the sampling sites selected for this study, Du Toit afforded the highest PCB concentration levels and the lowest was after chlorination at the Darvill wastewater treatment plant. The results presented are new and it is the first study of organic pollutants such as PCBs that has been carried out on this river.  相似文献   

17.
The present paper reports a detailed study that is based on the monitoring of naproxen, ibuprofen, and diclofenac in Mbokodweni River and wastewater treatment plants (WWTPs) located around the city of Durban in KwaZulu-Natal Province of South Africa. Target compounds were extracted from water samples using a multi-template molecularly imprinted solid-phase extraction prior to separation and quantification on a high-performance liquid chromatography equipped with photo diode array detector. The analytical method yielded the detection limits of 0.15, 1.00, and 0.63 μg/L for naproxen, ibuprofen, and diclofenac, respectively. Solid-phase extraction method was evaluated for its performance using deionized water samples that were spiked with 5 and 50 μg/L of target compounds. Recoveries were greater than 80% for all target compounds with RSD values in the range of 4.1 to 10%. Target compounds were detected in most wastewater and river water samples with ibuprofen being the most frequently detected pharmaceutical. Maximum concentrations detected in river water for naproxen, ibuprofen, and diclofenac were 6.84, 19.2, and 9.69 μg/L, respectively. The concentrations of target compounds found in effluent and river water samples compared well with some studies. The analytical method employed in this work is fast, selective, sensitive, and affordable; therefore, it can be used routinely to evaluate the occurrence of acidic pharmaceuticals in South African water resources.  相似文献   

18.
We analyzed water samples from the confluence of three municipal sewage treatment effluent streams, surface water, and whole carp (Cyprinus carpio) for synthetic musks for a period of 7-12 months. The lipid content of each fish was determined and compared with the concentration of musks in the whole fish tissue. Enhanced methods were used for water sampling and musk extraction. The data presented here provide insight as to the relationship between concentrations of synthetic musks in the municipal effluent and associated biota. This study confirmed the presence of polycyclic and nitro musk compounds in sewage effluent, Lake Mead water, and carp. The concentrations were found to be considerably lower than previous studies conducted in other countries. This study also provides data for polycyclic and nitro musk compounds, as well as some of the nitro musk metabolites in sewage treatment plant effluent, lake water, and carp.  相似文献   

19.
Bioassay using cultured human cell lines was applied to an effluent of a wastewater treatment plant (WWTP) in Sapporo to assess their toxicity, and in order to investigate the fate of toxicity in the WWTP, bioassay of the water samples from several points in WWTP (influent, effluent, return flow from thickener, from dewatering process and from incineration process) was performed. We also applied bioassay to the mixture of the activated sludge from the investigated plant and artificial sewage. These results showed that the toxicity of the effluent was more intensive than the influent, and organic matter released from activated sludge bacteria during their decay process contributed to the increase of toxicity in the effluent.  相似文献   

20.
This study is planned to perform a sanitary survey of the largest sewage treatment plant in Riyadh, KSA, fortnightly for 6 months to examine its effluent quality as an example for the growing dependence on reuse of treated municipal wastewater in agricultural irrigation purposes to cope with increasing water shortage. The biological and physico-chemical parameters of 12 wastewater samples from the plant were examined using standard methods. The physico-chemical analysis indicated that the surveyed municipal wastewater treatment plant contained some of the studied parameters, such as turbidity, total suspended solids, biochemical oxygen demand, chemical oxygen demand and residual chlorine above the maximum permissible wastewater limits set by the Saudi Standards. However, heavy metal concentrations in all samples were lower than the recommended standards. Total and faecal coliform counts were above the permissible limits indicating poor sanitation level. Fifty percent of all wastewater samples were contaminated with faecal coliforms but, surprisingly, Escherichia coli were only detected in 8.3 % of the samples. Regular monitoring and enhancement of microbial and physico-chemical parameters of the wastewater quality served by different wastewater treatment plants for reuse in agricultural irrigation is recommended to preserve the environment and public health.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号