首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   0篇
综合类   4篇
基础理论   4篇
污染及防治   6篇
评价与监测   1篇
社会与环境   2篇
  2018年   1篇
  2016年   1篇
  2015年   2篇
  2014年   6篇
  2013年   1篇
  2012年   2篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2003年   1篇
排序方式: 共有17条查询结果,搜索用时 15 毫秒
1.
This study characterized and discussed particulate ambient air particulate concentrations and seasonal variations for PM18, PM10, PM2.5, and PM1 during June 2013–July 2013 at this traffic sampling site. In addition, this study also characterized the ambient air particulates size distributions by using MOUDI-100S4 sampler to collect 1-day the ambient suspended particles (PM18, PM10, PM2.5, and PM1) at this sampling site. In addition, the study also showed that the main pollutants contributions were from traffic and residual areas. As for the pollutants seasonal concentrations variations, the results indicated that the average particle concentrations orders were all displayed as daytime?>?nighttime for PM18, PM10, PM2.5 and PM1 at this characteristic sampling site. The results further indicated that the mean highest of metal concentrations in this study indicated that the average metal concentration were all displayed as Mn?>?Cr?>?Ni?>?Pb?>?Cd for PM18, PM10, PM2.5 and PM1 on daytime and nighttime at this characteristic sampling site.  相似文献   
2.
魔芋葡甘聚糖在污水处理中的应用   总被引:4,自引:0,他引:4  
该文就魔芋葡甘聚糖的发展研究状况作了概述,并探讨其与蛋白质共混胶应用于水处理的可能性。  相似文献   
3.
Environmental Geochemistry and Health - The concentrations of particulates and metallic elements that were bound to total suspended particulates in ambient air at Long Cyuan Elementary School...  相似文献   
4.
This study characterized the dry deposition flux and dry deposition velocity (Vd) of metallic elements attached on particulate matter. Specifically, large particles (>10 μm), coarse particles (10 μm~2.5 μm), and fine particles (<2.5 μm) were studied at the Gong Ming Junior High School (Taichung Airport) and Taichung Harbor sampling sites in central Taiwan. Ambient air samples were collected to determine total suspended particulate matter (TSP), dry deposition plate (DDP), Vd, coarse particulate matter (PM2.5–10) and fine particulate matter (PM2.5), and metallic elements concentrations at the Airport and Taichung Harbor sites between June 17, 2013, and November 14, 2013. The results revealed that the average TSP, DDP, Vd, PM2.5–10, and PM2.5 particulate at the Airport were 54.55 (μg/m3), 902.25 (μg/m2-min), 17.11 (m/sec), 0.003 (μg/m3), and 0.010 (μg/m3), respectively; while these values at Taichung Harbor were 63.66 (μg/m3), 539.69 (μg/m2-min), 9.94 (m/sec), 0.003 (μg/m3), and 0.014 (μg/m3), respectively. In addition, the results showed that the average Cu and Pb concentrations were higher than Cr, Ni, and Cd for both the airport and harbor sampling sites. Furthermore, Cr, N, Cu, Cd, and Pb had the highest average concentrations versus those reported for other study areas, with one exception: The results obtained in Kacanik, Kosovo, during 2005. The average metallic elements concentrations order was Cu > Pb > Cr > Ni > Cd.  相似文献   
5.
Chen YC  Tsai PJ  Mou JL  Kuo YC  Wang SM  Young LH  Wang YF 《Chemosphere》2012,88(11):1324-1331
In this study, the cost-benefit analysis technique was developed and incorporated into the Taguchi experimental design to determine the optimal operation combination for the purpose of providing a technique solution for controlling both emissions of PCDD/Fs and PAHs, and increasing both the sinter productivity (SP) and sinter strength (SS) simultaneously. Four operating parameters, including the water content, suction pressure, bed height, and type of hearth layer, were selected and all experimental campaigns were conducted on a pilot-scale sinter pot to simulate various sintering operating conditions of a real-scale sinter plant. The resultant optimal combination could reduce the total carcinogenic emissions arising from both emissions of PCDD/Fs and PAHs by 49.8%, and increase the sinter benefit associated with the increase in both SP and SS by 10.1%, as in comparison with the operation condition currently used in the real plant. The ANOVA results indicate that the suction pressure was the most dominant parameter in determining the optimal operation combination. The above result was theoretically plausible since the higher suction pressure provided more oxygen contents leading to the decrease in both PCDD/F and PAH emissions. But it should be noted that the results obtained from the present study were based on pilot scale experiments, conducting confirmation tests in a real scale plant are still necessary in the future.  相似文献   
6.
The objective of this exposure assessment was to reconstruct cumulative historical exposures for workers who have been exposed to multiple chemicals and chemical groups to better understand a cluster of brain cancers within a research and development lab. Chemicals of interest, including acrylates, bis-chloromethyl ether (BCME), chloromethyl methyl ether (CMME), isothiazolones and nitrosoamines, were selected on the basis of the plausibility of penetrating the blood-brain barrier and the uniqueness of the chemical's biological activity.In a complicated exposure setting such as a chemical R&D facility, multiple exposure estimation methods were needed. First, similarly exposure groups (SEGs) were created for these materials based on department group, time period of the department's existence and function associated with job titles. A probabilistic framework for assessing exposures was developed using Bayesian analysis of historical monitoring data, mathematical exposure modeling and professional judgments of current and former industrial hygienists at the facility were used to reconstruct the exposure history for acrylates, BCME and CMME for each SEG over the time period of interest. Since sufficient measurement data for isothiazolones and nitrosoamines were not available, the exposure histories for each SEG for these chemicals were estimated. This was done using objective formaldehyde levels and subjective employee interviews. The interviews assessed workplace determinants of exposure as distinct surrogates for estimating inhalation and dermal exposures. The exposure assessments by these methods were compared against each other to estimate the potential for exposure misclassification. A job exposure matrix (JEM) was constructed that contained the exposures obtained from above multiple approaches for each of these chemical groups for each SEG for each year of interest. The combination of methods used in this work is a unique and potentially helpful framework that can be used in analogous workplace settings involving multiple exposures with incomplete objective measurement information.  相似文献   
7.

Background, aim, and scope  

This study developed an integrated approach to identify pollutant sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) of workers based on their blood contents.  相似文献   
8.

The main purpose of this study was to monitor ambient air particles and particulate-bound mercury Hg(p) in total suspended particulate (TSP) concentrations and dry deposition at the Hung Kuang (Traffic), Taichung airport and Westing Park sampling sites during the daytime and nighttime, from 2011 to 2012. In addition, the calculated/measured dry deposition flux ratios of ambient air particles and particulate-bound mercury Hg(p) were also studied with Baklanov & Sorensen and the Williams models. For a particle size of 10 μm, the Baklanov & Sorensen model yielded better predictions of dry deposition of ambient air particulates and particulate-bound mercury Hg(p) at the Hung Kuang (Traffic), Taichung airport and Westing Park sampling site during the daytime and nighttime sampling periods. However, for particulates with sizes 20–23 μm, the results obtained in the study reveal that the Williams model provided better prediction results for ambient air particulates and particulate-bound mercury Hg(p) at all sampling sites in this study.

  相似文献   
9.
This investigation studied the concentrations of ambient air total gaseous mercury (TGM) during the rainy periods at the Hung-Kuang traffic sampling site in central Taiwan from May 26 to June 16, 2014. The results were compared with those of a previous study for ambient air TGM during non-rainy daytime and nighttime periods at the Hung-Kuang traffic sampling site, which was conducted during March 21 to July 20, 2012. The observed mean concentration of ambient air TGM was 1.16 ng/m3 during the rainy periods at the Hung-Kuang traffic sampling site. The mean ambient air TGM concentrations were higher in the non-rainy sampling period in daytime than in the rainy sampling period from this study. The mean ratio of non-rainy sampling period in daytime to that of rainy sampling period for ambient air TGM were 3.15. Furthermore, the mean ambient air TGM concentrations were higher in the non-rainy sampling period in nighttime in than in the rainy sampling period for this study. The mean rations for non-rainy sampling period in nighttime to that of the rainy sampling period for ambient air TGM were 2.70. The results obtained in this study also revealed that the ambient air TGM concentrations during the rainy period had the lowest concentrations when compared with the other sampling sites in other world regions.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号