首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   70篇
  免费   7篇
  国内免费   20篇
安全科学   13篇
废物处理   5篇
环保管理   2篇
综合类   28篇
基础理论   10篇
污染及防治   20篇
评价与监测   6篇
社会与环境   1篇
灾害及防治   12篇
  2023年   1篇
  2022年   2篇
  2021年   7篇
  2020年   2篇
  2019年   3篇
  2018年   3篇
  2017年   5篇
  2016年   3篇
  2015年   2篇
  2014年   3篇
  2013年   17篇
  2012年   13篇
  2011年   8篇
  2010年   4篇
  2009年   4篇
  2008年   3篇
  2007年   1篇
  2006年   3篇
  2005年   2篇
  2004年   3篇
  2003年   2篇
  2002年   1篇
  2001年   3篇
  1995年   1篇
  1991年   1篇
排序方式: 共有97条查询结果,搜索用时 953 毫秒
1.
Fault detection (FD) and diagnosis in industrial processes is essential to ensure process safety and maintain product quality. Partial least squares (PLS) has been used successfully in process monitoring because it can effectively deal with highly correlated process variables. However, the conventional PLS-based detection metrics, such as the Hotelling's T2 and the Q statistics are ill suited to detect small faults because they only use information from the most recent observations. Other univariate statistical monitoring methods, such as the exponentially weighted moving average (EWMA) control scheme, has shown better abilities to detect small faults. However, EWMA can only be used to monitor single variables. Therefore, the main objective of this paper is to combine the advantages of the univariate EWMA and PLS methods to enhance their performances and widen their applicability in practice. The performance of the proposed PLS-based EWMA FD method was compared with that of the conventional PLS FD method through two simulated examples, one using synthetic data and the other using simulated distillation column data. The simulation results clearly show the effectiveness of the proposed method over the conventional PLS, especially in the presence of faults with small magnitudes.  相似文献   
2.
分子印迹技术在环境科学领域中的应用   总被引:7,自引:0,他引:7  
分子印迹技术(MIT)是一门新兴的边缘科学技术,它的产生与发展为环境科学打开了又一视角。介绍了MIT的产生与发展及基本原理,综述了MIT在环境科学领域中的应用,主要包括MIT在固相萃取、膜分离、色谱分析、传感器及分子印迹聚合物作为催化剂在环境修复中的应用。  相似文献   
3.
主要介绍了GPS技术的最新发展、应用及原理,结合成熟的GPS技术,设计了一套对飞行目标的位置自动跟踪系统。该系统以C51系列单片机为数据处理核心器件,前接GPS接收机,将GPS的测量信息进行分析处理,产生控制信号,输出给后续的伺服机构,驱动伺服机构完成自动跟踪。本系统可以在森林防火指挥系统中,完成火灾监测、人员、物资调配等工作,使火灾造成的损失降低到最小。  相似文献   
4.
为了揭示土壤剖面中含氧非烃污染物的迁移特征,以及TOC和淋滤水量等因素对迁移作用的影响,选择了部分典型的含氧非烃开展了纵向迁移的土柱淋滤实验,对原土及添加污染物的土柱淋滤实验后样品中含氧非烃的含量及组成进行了对比分析.结果表明,土柱淋滤实验后,土柱表层添加的含氧非烃主要残留在土柱表层0~5 cm范围内,但相比所添加的化合物的量均有不同程度的降低,土柱深部(>10 cm)土壤中含氧非烃含量仍然很低,甚至低于原土中的,在TOC较高的土柱中,这种现象尤为突出.说明土柱淋滤实验过程中,不同剖面含氧非烃均存在向下迁移的现象,且以水溶方式迁移为主.不同含氧非烃单体含量均有随深度增加而降低的趋势,表明其在土壤剖面淋滤过程中均具有一定的迁移性,但不同性质的含氧非烃单体在表层土中残留量及组成差别较大,说明不同化合物迁移能力存在差别,其中,胆甾醇、β-谷甾醇、正构十六烷酸和邻苯二甲酸二丁酯迁移性较强.土壤TOC和淋滤水量对含氧非烃在土壤剖面的迁移作用都有不同程度的影响,淋滤水量相同时,TOC含量越高,土壤中有机质越丰富,越容易富集含氧非烃;TOC相同时,淋滤水量越大,含氧非烃迁移量越大,迁移的深度越大,尤其在TOC含量较低时更明显.  相似文献   
5.
为研究震损RC柱采用FRP(Fiber Reinforced Polymer,FRP)加固修复后的抗震性能,本文基于OpenSees仿真平台,根据震后RC柱的表观损伤状态提出FRP加固震损RC柱的有限元模型建立方法。对FRP加固震损RC柱进行5120种工况的Pushover分析,采用三折线荷载-位移骨架曲线,研究损伤状态对骨架曲线特征点参数的影响规律,并通过数据回归分析提出FRP加固震损RC柱的骨架曲线计算模型。分析结果表明:损伤会降低FRP加固RC柱的承载力及刚度,且降低程度随损伤指数的增大而增加,两者近似成抛物线关系;在DS-5损伤状态下,相比于FRP加固完好RC柱,FRP加固震损RC柱的屈服承载力P y、峰值承载力P c、弹性刚度K 1、弹塑性刚度K 2及下降段刚度K 3的均值下降17.9%、14.5%、41.8%、43.1%和19.9%;损伤对FRP加固RC柱弹性刚度和弹塑性刚度的降低程度明显高于屈服承载力和峰值承载力;文中提出的FRP加固震损RC柱骨架曲线计算模型具有较高精度。  相似文献   
6.
周魁  杨明  马晶  孙倩 《环境工程学报》2012,6(4):1220-1224
以微米级聚苯乙烯微球为种球,活性艳橙K-7R为模板分子,甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸酯为交联剂,采用单步溶胀聚合法在水相中制得了分子印迹聚合物微球(MIPs),并用平衡吸附实验研究了其吸附性能。通过Scatchard分析,结果表明,MIPs在识别K-7R过程中存在两类结合位点,高亲和力结合位点的平衡离解常数Kd1=14.855μmol/L,最大结合量Qmax1=1.282μmol/g;低亲和力结合位点的平衡离解常数Kd2=70.939μmol/L,最大结合量Qmax2=3.930μmol/g。该MIPs对K-7R有较高的亲和性和选择性。  相似文献   
7.
A molecularly imprinted polymer (MIP) for atrazine was synthesized by non-covalent method. The binding capacity of MIP was 1.00 mg g? 1 polymer. The selectivity and recovery were investigated with various pesticides which are mostly, found in the environment, for both similar and different chemical structure of atrazine. The competitive recognition between atrazine and structurally similar compounds was evaluated and it was found that the system provided highest recovery and selectivity for atrazine while low recovery and selectivity were obtained for the other compounds. The highest recovery was obtained from MIP compared with non-imprinted polymer (NIP), a commercial C18 and a granular activated carbon (GAC) sorbent. The method provided high recoveries ranged from 94 to 99% at two spiked levels with relative standard deviations less than 2%. The lower detection limit of the method was 80 ng L? 1. This method was successfully applied for analysis of environmental water samples.  相似文献   
8.
• Selective molecularly imprinted polymer (MIP) binding gel was prepared. • MIP-DGT showed excellent uptake performance for antibiotics. • In situ measurement of antibiotics in wastewaters via MIP-DGT was developed. • The MIP-DGT method was robust, reliable, and highly sensitive. Urban wastewater is one of main sources for the introduction of antibiotics into the environment. Monitoring the concentrations of antibiotics in wastewater is necessary for estimating the amount of antibiotics discharged into the environment through urban wastewater treatment systems. In this study, we report a novel diffusive gradient in thin films (DGT) method based on molecularly imprinted polymers (MIPs) for in situ measurement of two typical antibiotics, fluoroquinolones (FQs) and sulfonamides (SAs) in urban wastewater. MIPs show specific adsorption toward their templates and their structural analogs, resulting in the selective uptake of the two target antibiotics during MIP-DGT deployment. The uptake performance of the MIP-DGTs was evaluated in the laboratory and was relatively independent of solution pH (4.0–9.0), ionic strength (1–750 mmol/L), and dissolved organic matter (DOM, 0–20 mg/L). MIP-DGT samplers were tested in the effluent of an urban wastewater treatment plant for field trials, where three SA (sulfamethoxazole, sulfapyridine, and trimethoprim) and one FQ (ofloxacin) antibiotics were detected, with concentrations ranging from 25.50 to 117.58 ng/L, which are consistent with the results measured by grab sampling. The total removal efficiency of the antibiotics was 80.1% by the treatment plant. This study demonstrates that MIP-DGT is an effective tool for in situ monitoring of trace antibiotics in complex urban wastewaters.  相似文献   
9.
Perfluorooctane sulfonate (PFOS), as a potential persistent organic pollutant, has been widely detected in water environments, and has become a great concern in recent years. PFOS is very stable and difficult to decompose using conventional techniques. Sorption may be an attractive method to remove it from water. In this study, the molecularly imprinted polymer (MIP) adsorbents were prepared through the polymerization of 4-vinylpyridine under different preparation conditions in order to remove perfluorooctane sulfonate (PFOS) from water. The MIP adsorbents using perfluorooctanoic acid (PFOA) as the template had good imprinting effects and could selectively remove PFOS from aqueous solution. The sorption behaviors including sorption kinetics, isotherms, and effect of pH, salt, and competitive anions were investigated. Experimental results showed that the sorption of PFOS on the MIP adsorbents was very fast, pH-dependent, and highly selective. The achieved fast sorption equilibrium within 1 h was attributed to the surface sorption on the fine adsorbents. The sorption isotherms showed that the sorption selectivity of PFOS on the MIP adsorbents decreased at high PFOS concentrations, which may be due to the double-layer sorption and the formation of PFOS micelles on the sorbent surface. The sorption of PFOS on the MIP adsorbents was mainly dominated by the electrostatic interaction between the protonated vinylpyridine on the adsorbent surface and the anionic PFOS. The prepared MIP adsorbents can potentially be applied in water and wastewater treatment for selective removal of PFOS.  相似文献   
10.
贾琳瑜  周勇  胡洋  程旭东 《火灾科学》2014,23(3):155-161
在开敞空间条件下利用油池火模拟不同的火灾场景,对火源燃烧阶段和燃烧结束后钢管混凝土柱的温度变化进行研究。测量了燃料质量变化和钢管混凝土柱的温度分布等参数,分析不同火灾场景下钢管混凝土柱轴向、横截面的温度变化,并以实验工况HS3为例进行深入分析,同时分析了火源的燃烧时间、热释放速率对钢管混凝土柱温度场分布的影响。研究结果表明,钢管混凝土柱纵向温度分布与横向温度分布一样都存在明显的温度梯度,其表面钢管温度变化受火场热释放速率影响较大,而内部混凝土的温度变化则主要受火场持续时间的影响。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号