首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 234 毫秒
1.
通过对常见的几种检测管法的比较,筛选出灵敏度较高的亚硝基铁氰化钠法;同时筛选出载体为60—80目的素陶瓷,指示剂浓度为20%。玻璃管内径为2.0—2.3mm,采气速度为0.3(L/min),采样体积为12L,以此条件进行实验.结果表明,检测管变色长度对应SO2浓度的相关性很好;变异系数均小于110%,检测的重现性较好。检测管的测定值与理论值的平均相对误差为5.09%(<±15%),最大相对误差为7.13%(<±25%),准确度较高.测定结果可靠;与化学法比较,两者无显著性差异;浓度小于0.15mg/m3的H2S及浓度小于0.01mg/m3的NO2对SO2检测管无干扰.  相似文献   

2.
应用活性氧铝—百里香酚酞吸附CO2线性比长法研制出低浓度CO2检测管。测定范围0.05~0.90%;灵敏度为0.05%;检测管变色长度与CO2浓度的相关系数γ=0.9981,精密度与准确度符合国家标准83GB7220~7280。其可靠性与经典的何氏气体分析器比较,结果基本一致。低浓度的SO2、H2S和NH3对测定无明显干扰,现场监测应用效果可靠,值得推广应用。  相似文献   

3.
氨气检测管的研制   总被引:4,自引:0,他引:4  
经过条件优化试验,研制出氨气检测管,检测管显色长度与氨气浓度呈线性相关,对氨气标气7次测定的变异系数为11.9%,平均相对误差为7.2%,小于15%,一次测定最大相对误差为22%,小于25%,符合国家标准GB730-87的要求,与化学法比较,2种方法测试结果无显著性差异,检测管检测范围为70-500mg/m^3,有机胺产生正干扰,酸性气产生负干扰,检测管寿命为1a。  相似文献   

4.
用抑制型离子色谱法探讨了SeO3(2)和SeO4(2-)等七种阴离子的洗脱行为,讨论了共存阴离子的干扰及其消除,建立了测定水中seO3(2-)和SeO4(2-)等阴离子的方法.SeO3(2-)和SeO4(2-)的检测限分别为40μg/L和50μg/L.  相似文献   

5.
发生氢气分离离子色谱法间接测定水中硫化物   总被引:1,自引:0,他引:1  
利用KBH4在酸性条件下分解产生的氢气为载气分离水中硫化物,用NaOH—H2O2溶液吸收H2S,并将其氧化为SO2-4,用离子色谱法测定SO2-4。方法用于各种水样中硫化物的测定,相对标准偏差为1.58%,回收率在90.5%到98.2%之间。方法适用于水中硫化物的测定  相似文献   

6.
经过条件优化试验,研制出氯气检测管。检测管显色长度与氯气浓度呈线性相关,对氯气标气7次测定的变异系数为13.8%,平均相对误差为5.2%,小于15%;一次测定最大相对误差为20%,小于25%,符合国家标准GB7230-87的要求。与化学法比较,2种方法测试结果无显著性差异。干扰物有溴和氯化氢气体以及高浓度二氧化氮。检测管寿命为1a。  相似文献   

7.
应用气相色谱(GC)Ni63电子捕获检测器(ECD),在6201红色担体为基体,涂10%OV-101固定液的玻璃柱上,以甲苯作吸收液,对大气环境中微量二硫化碳能够进行定量检测,其最低检出浓度可达6×10-6mg/ml(进液体样品1μl);方法精密度为3.4%,SO2、H2S气体物质不干扰测定。经现场实际环境样品测试,此方法能够适用于大气环境中微量CS2的分析工作,为大气环境监测微量CS2的分析建立了一个比较合适的方法。  相似文献   

8.
异相平衡流动注射分光光度法测定水中痕量SO^2—4   总被引:2,自引:0,他引:2  
根据异相平衡的原理,确立了用流动注射分光光度法测定水样中痕量SO^2-4的新方法。利用Ba(Ⅱ)与偶氮氯磷Ⅲ的二元络合显色反应及BaSO4=Ba^2++SO^2-4进入微溶化合物BaSO4反应柱前后吸光值的改变,从而求得SO^2-浓度。表观摩尔吸光系数ε=2.3*10^4L.mol^-1.cm^-1,SO^2-4检的线性范围为0-40mg/L,检测限为0.80mg/L,相对标准偏差为1.2%,试  相似文献   

9.
底质中汞的快速消解方法王国朝,王鲁海,周春华,刘新凤(新疆乌鲁木齐市环境科研监测站,839000)底质中汞的消解方法有湿法和于法两种。文献[1.2]介绍的湿法有:H2SO4-KMnO4电热板加热和水浴加热法;H2SO4-HNO3-KMnO4电热板加热...  相似文献   

10.
IC色谱仪电位法测定S^2—的运用与研究   总被引:2,自引:0,他引:2  
介绍了应用YIC-8型离子色谱仪电化学检测器测定标准样品及废水样中S^2-的含量,同时与化学法进行比较,肯定了电位法的准确性、可靠性。  相似文献   

11.
硫化氢检测管的研制   总被引:5,自引:0,他引:5  
经过条件优化试验,研制出硫化氢检测管,其显色长度与硫化氢浓度呈线性相关,对硫化氢标气7次测定的变异系为14.6%,平均相对误差为2%,小于15%,一次测定最大相对误差为18.8%,小于25%,符合国家标准(GB7230-87)的要求,与化学法比较,2种方法测试结果无显著性差异。  相似文献   

12.
无火焰原子吸收法测定可溶性硫化物的基本原理是使水中硫化物与硝酸银反应,生成硫化银沉淀,沉淀过滤后用原子吸收分光光度计测定剩余银含量,间接测定硫化物含量。本文通过对无火焰原子吸收法测定银含量过程中的各种条件试验,并加以分析研究。实验表明此方法具有测定灵敏度高,背景值测定具有优越性等特点,完全满足污水中硫化物监测的需要。  相似文献   

13.
Febros river water was sampled weekly, during 35 successive weeks, and analyzed for microbiological (total coliforms, faecal coliforms, faecal streptococci and enterococci) and chemical-physical (ammonia and temperature) parameters. All microbiological parameters were highly correlated with each other and with ammonia, suggesting that the simultaneous determination of all variables currently in use in the evaluation of the microbiological quality of waters is probably redundant, and could be simplified, and that ammonia should be tested as a sentinel parameter of the microbiological pollution load of Febros river. From the strains isolated from positive tubes of the faecal coliforms test (multiple tube fermentation technique) and retested in this assay, Escherichia coli, Klebsiella oxytoca and Klebsiella pneumoniae subsp. pneumoniae strains were positive, indicating that the faecal coliforms test is not totally specific for Escherichia coli, and can detect other bacteria. Considering that these Klebsiella spp. are not necessarily of faecal origin, it was concluded that the faecal coliforms test can overestimate true faecal pollution. From the strains isolated from positive tubes of the faecal coliforms procedure, only Escherichia coli strains were clearly positive in the β-D-glucuronidase test. All other species were negative or very weakly positive, suggesting that the assay of the β-D-glucuronidase activity is less prone to false positives than the faecal coliforms test in the quantification of Escherichia coli in environmental waters.  相似文献   

14.
阐述了应用发光细菌检测有色水样毒性时,水样色度会引起附加发光抑制的原因,提出应用同心双层检测玻管,可以对有色水样色度引起的附加发光抑制加以修正.通过比较单层管和双层管测定标准曲线间的差异、设置阴性对照和阳性对照评价该方法的可靠性,以及用该方法检测有色水样活性黑KN-B溶液的急性毒性实验,结果表明,用同心双层检测玻管可以有效修正由水样色度引起的附加发光抑制.  相似文献   

15.
为了克服分光光度法反应时间难以控制引起的方法精密度、准确度不高的弱点,采用流动注射技术与分光光度法相结合的方法,用微机化流动注射分析仪准确控制时间,优化了实验条件,建立了测定痕量硫化物的流动注射分光光度方法。分析速度每小时80次,擎一质量浓度在0.02~0.8mg/L与吸光度A具有良好的线性关系。方法直接测定海水和鱼塘水中的硫化物获得满意的结果,回收率分别为100.28%和97.13%。  相似文献   

16.
热脱附/气相色谱法测定空气中含硫化合物   总被引:1,自引:0,他引:1       下载免费PDF全文
以固体CO2为冷却试剂,使空气中含硫化合物有效富集在-70℃条件下TANEX复合吸附管内,样品管在热脱附装置中120℃下解吸后,采用气相色谱脉冲式火焰光度检测器测定硫化氢、甲硫醇、二甲二硫和甲硫醚,优化了试验条件。4种含硫化合物检出限为0.1ng—0.5ng,标准管测定的RSD为12.7%—16.3%,实际气样加标回收率为78.3%—87.7%。  相似文献   

17.
介绍了直接吸收显色法分析水质硫化物中,气体分离管在实际操作中存在的缺点和氢氧化钾溶液替换气体分离管的优点,并通过实验来论证替换的可行性。  相似文献   

18.
固相萃取光度法测定食品中挥发酚的研究   总被引:3,自引:0,他引:3  
研究了用Waters Sep-Park-C18固相萃小柱固相萃取测定食品中挥发酚的方法,用自动水蒸汽蒸馏仪蒸馏分离出食品中的挥发酚,然后用4-氨基安替比林显色,显色产物可用Waters Sep-Park-C18固相萃小柱萃取,用乙醇洗脱后用分光光度法测定,该方法污染小,操作简便,便于样品批量处理,用于食品样品中挥发酚的测定,结果令人满意。  相似文献   

19.
粪大肠菌群快速测定——纸片法的应用   总被引:1,自引:0,他引:1  
采集苏州具有代表性的地表水水体22个点位的样品,进行粪大肠菌群的测定方法比较,结果表明,《粪大肠菌群快速测定--纸片法》适于测定受粪便污染程度较轻的湖泊水体.但是,该方法的培养时间对阳性管率有明显影响,认为16 h~18 h是比较理想的培养时间.  相似文献   